首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
20-Hydroxy-arachidonic acid (20-HETE) was determined in urine by an isotope dilution assay using gas chromatography/mass spectrometry (GC/MS). After addition of 18O2-internal standard, 20-HETE was extracted from urine with hexane either directly or after treatment with glucuronidase. 20-HETE was derivatized to the pentafluorobenzylester and the sample was applied to thin layer chromatography with iso-octane/iso-propanol 9:1 (v/v) as the developing solvent. The corresponding zone was extracted and 20-HETE was hydrogenated. After derivatization to the trimethylsilylether, 20-HETE was determined by GC/MS using the [M-pentafluorobenzyl]- -ion in the negative ion chemical ionization mode. Excretion rates of free and glucuronide conjugated 20-HETE was determined in healthy children and in children with hyperprostaglandin-E-syndrome/antenatal Bartter syndrome (HPS/aBS) with or without indomethacin treatment. Compared to the controls, the HPS/aBS children showed higher excretion rates of 20-HETE, which were suppressed to normal values under indomethacin medication. Free and glucuronide conjugated 20-HETE do not correlate with PGE2 excluding any participation in HPS/aBS.  相似文献   

3.
A quantitative method for determination of nitroglycerin in human plasma was developed. Nitroglycerin and the internal standard (butane-1,2,4-triyl trinitrate) were extracted from plasma with pentane. The extracts were analysed by gas chromatography mass spectrometry using fused silica capillary columns and electron capture negative ion chemical ionization. The quantitation limit of the method was about 50 pg ml-1. Linear calibration curves were obtained in the range of 50-1600 pg ml-1. Precision at the level of 100 pg ml-1 was 4%.  相似文献   

4.
Dexamethasone (DXM) is a synthetic glucocorticoid that is authorized for therapeutic use in veterinary medicine. The European Community (EC) fixed a maximum residue limit (MRL) at 2ng/g for liver, 0.75ng/g for muscle and kidney tissues, and 0.3ng/ml for milk, while its use as growth-promoter is completely banned. The purpose of this study was to develop and validate a simple and reliable method to determine DXM residues in bovine milk. Milk proteins were removed by the addition of concentrated trichloroacetic acid and paper filtration. Solid-phase extraction clean-up on a C18 reversed phase column was performed to obtain an extract suitable for liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Chromatographic separation of DXM and the internal standard desoximetasone, was achieved on a PLRP-S polymeric reversed phase column, using a mixture of 0.1% (v/v) acetic acid in water (mobile phase A) and acetonitrile (mobile phase B) as the mobile phases. They were identified using the MS/MS detection technique, and were subsequently quantified. The method has been validated according to the requirements of the EC at 0.15, 0.30 and 0.60ng/ml (being half the MRL, the MRL and double the MRL levels fixed by the EC). Calibration graphs were prepared in the 0.15-5ng/ml range and good linearity was achieved (r>or=0.99 and goodness of fit 相似文献   

5.
A quantitative method for the determination of allopregnanolone (5alpha,3alpha-THP) and related neurosteroids in CSF and plasma was established using gas chromatography/electron capture negative chemical ionization mass spectrometry (GC/ECNCI/MS). Neurosteroids were converted to carboxymethoxime, pentafluorobenzyl and trimethylsilyl derivatives and detected as intense (M-181)(-) fragment ions generated under the negative ion chemical ionization process. The response curves constructed using d(4)-dihydrotestosterone (DHT) and d(4)-5alpha,3alpha-THP as internal standards showed linearity in the concentration range of 10-1000 pg/ml. The variation of response ratios determined against internal standards over a 2-month period was less than 10%. Instrumental detection limits for most neurosteroids were in the low picogram range with the exception of progesterone and dihydroprogesterone (DHP) which were detected with approximately 10 times less sensitivity in comparison to other steroids. In conjunction with solid-phase extraction, this method allowed the quantification of at least four neurosteroids, including androsterone, testosterone, 5alpha,3alpha-THP, and pregnenolone in 1-2 ml of human cerebrospinal fluid (CSF). While the level of 5alpha, 3alpha-THP in human CSF was comparable to that in the human plasma, other steroid levels were significantly lower. Although individual CSF and plasma samples showed widely varying neurosteroid levels, species specificity appeared to exist. The levels of 5alpha, 3alpha-THP and pregnenolone in human CSF were higher than those of monkey CSF where these steroids were often not detected with our current detection limit. In comparison to human plasma, rat plasma samples contained considerably lower levels of androsterone and pregnenolone. Among THP stereoisomers, 5beta,3alpha-THP and 5alpha, 3beta-THP were observed only in human plasma, while 5beta,3beta-THP was detected only in rat plasma.  相似文献   

6.
In an isotope dilution assay, prostaglandin (PG) E2, 6-keto-PGF, thromboxane (Tx) B2 and their metabolites PGE-M (11α-hydroxy-9,15-dioxo-2,3,4,5,20-pentanor-19-carboxyprostanoic acid), 2,3-dinor-6-keto-PGF, 2,3-dinor-TxB2 and 11-dehydro-TxB2 were determined in urine by gas chromatography—triple stage quadrupole mass spectrometry (GC—MS—MS). After addition of deuterated internal standards, the prostaglandins were derivatized to their methoximes and extracted with ethyl acetate—hexane. The sample was further derivatized to the pentafluorobenzylesters and purified by thin-layer chromatography (TLC). Three zones were scraped from the TLC plate. The prostanoid derivatives were converted to their trimethylsilyl ethers and the products were quantified by GC—MS—MS. In each run, two or three prostanoids were determined.  相似文献   

7.
A comparison of the sensitive analytical methods of radioimmunoassay (RIA) and immunoaffinity chromatography (IAC) combined with gas chromatography—negative ion chemical ionisation mass spectrometry for the specific and reliable screening of dexamethasone in equine post-race urine is presented. Results from analyses of samples collected from a mare during 144 hours post administration of 26 mg of dexamethasone sodium phosphate are described.  相似文献   

8.
Because of the recognized inaccuracy and unreliability of currently available methods for the quantification of histamine in biological fluids, a method for quantification of urinary histamine by stable isotope dilution assay with negative ion chemical ionization mass spectrometry has been developed. Following the addition of [2H4]histamine to 1 ml of urine, histamine is extracted into butanol, back-extracted into HCl, derivatized to the pentafluorobenzyl derivative (CH2C6F5)3-histamine, extracted into methylene chloride, and then quantified with negative ion chemical ionization mass spectrometry by selected ion monitoring of the ratio of ions mz430434. Twenty samples can be assayed in 2 days. Precision of the assay is ±2.7% and the accuracy is 97.6%. Lower limits of sensitivity are approximately 100–500 fg injected on-column. This assay provides a very sensitive, accurate, and efficient method for the quantification of histamine in human urine.  相似文献   

9.
A gas chromatographic-negative ion chemical ionization mass spectrometric (GC-NCI-MS) method for the determination of flumazenil in plasma is described. The GC of flumazenil (Mr 303) is considered to be difficult as it is readily adsorbed in the GC column. Therefore, preconditioning the GC column with reconstituted extract from plasma and Silyl-8 was required to cover the active sites on the column. Monitoring the maximum mass peak (m/z 275) of the flumazenil resulted in a tenfold enhancement of sensitivity and signal-to-noise ratio (concentration = 1 ng/ml). Isotopically labeled flumazenil-d3 (Mr 306, m/z 278) was used as the internal standard. The detection limit for flumazenil was found to be 0.1 ng/ml with an injection volume of 2 μl. The signal-to-noise ratio was about 10. The routine quantification limit was set at 2 ng/ml for dog plasma and 1 ng/ml for human plasma. The sample volumes in both instances were 1 ml.  相似文献   

10.
A rapid and sensitive headspace gas chromatographic and mass spectrometric (GC–MS) method was developed for the determination of acrolein in human urine. A 0.5-ml urine sample in a glass vial containing propionaldehyde as an internal standard was heated at 80°C for 5 min. A 0.1-ml volume of headspace vapor was injected into a GC–MS instrument. Acrolein and propionaldehyde were coeluted at 3.1 min using a DB-1 capillary column, and well separated by selective ion monitoring (SIM) mode using ions m/z 56.05 and m/z 58.05. The interassay and intraassay coefficient of variation were 0.99% and 3.3%. The calibration curve demonstrated a good linearity throughout concentrations ranging from 1 to 1000 nM. However, due to a wide variation of acrolein evaporation rates from human urine, a calibration curve must be established for each urine specimen using a standard addition method and detection limit varied from 1 to 5 nM. The total analysis time for two samples from one urine specimen required about 15 min. Therefore, this method is convenient for the urgent monitoring of urinary acrolein in patients to whom alkylating agents are administered.  相似文献   

11.
A method is described for the determination of residues of the antibiotic chloramphenicol in biological samples. The method is based on gas chromatography/negative ion chemical ionization mass spectrometry and uses (37Cl2)chloramphenicol as internal standard. Selective ion monitoring of four analyte-specific ions enables the determination of chloramphenicol levels in urine of 3 micrograms l-1 with a coefficient of variation of 8%. The limit of detection of the method is 0.1 p.p.b. for urine, muscle and egg.  相似文献   

12.
A method for assay of urinary 6-hydroxymelatonin, the major metabolite of the pineal hormone melatonin is described. After addition of an internal standard of deuterated 6-hydroxymelatonin sulfate, human urine was hydrolyzed enzymatically and free 6-hydroxymelatonin extracted, reacted to form a stable t-butyldimethylsilylpentafluoropropionyl derivative which was separated on silica gel column chromatography, and quantified using electron capture negative-ion chemical ionization mass spectrometry. Intrassay variability over an 18-h period was 5.4% [53.8 ng/3 ml urine ± 2.94 (SD)] and interassay variability over a 2-week period was 2.1% [51.8 ng/3 ml urine ± 1.08 (SD)].  相似文献   

13.
A highly sensitive and specific quantitative assay for the determination of albuterol in human plasma, based on selected ion monitoring gas chromatography chemical ionization mass spectrometry, has been developed. The [MH]+ ions from the tri-TMS derivatives of albuterol (m/z 456) and the internal standard (2H3)albuterol (m/z 459), were assayed simultaneously by selected ion monitoring. The lower limit of quantitation is 0.25 ng ml-1 and the average assay precision (CV) for albuterol concentrations ranging from 0.25 ng ml-1 to 25 ng ml-1 is approximately 4%. This method is currently being employed for the routine quantitation of albuterol in plasma following the administration of doses therapeutically effective to man.  相似文献   

14.
A sensitive and selective gas chromatographic mass spectrometric method for the determination of midazolam and its biologically active metabolite, 1-hydroxymidazolam, in rabbit plasma has been developed and validated. Sample preparation includes mixed-mode solid-phase extraction and derivatization with silylating reagents. Midazolam-d4 was used as an internal standard for the determination of parent drug and its active metabolite. The instrumentation consisted of a capillary column gas chromatography and a single quadrupole mass spectrometer with a negative chemical ionization. The method was found to be valid in terms of selectivity, linearity, precision, accuracy, and recovery over the concentration range of 2-200 ng/ml and 1-100 ng/ml for midazolam and 1-hydroxymidazolam, respectively. For both analytes, the lower limit of quantification was 2 ng/ml. Midazolam was stable in stock solutions stored three months at -20°C and in human plasma stored for three months at -80°C. In addition, no degradation of midazolam was found after three freeze-thaw cycles, in short-term stability at room temperature for 24h, or in post-preparative stability in the autosampler. The validity of the method was further tested by performing a pharmacokinetic study of sublingual administration of midazolam in rabbits. The method will be used in studies related to a formulation development of novel midazolam formulations for use in paediatric anaesthesia.  相似文献   

15.
A gas chromatography mass spectrometric method using negative chemical ionisation was developed for the determination of stable isotopes of selenium for evaluation of selenium absorption and retention from foods in humans. The method involves an acid digestion to convert all selenium into selenite, which subsequently reacts with 4-nitro-o-phenylene-diamine to form a volatile piazselenole. The piazselenole, after extraction into an organic solvent, was analysed for its isotopic selenium composition by gas chromatography mass spectrometry. Negative chemical ionisation is reported for the first time for the determination of selenium stable isotopes and its analytical characteristics were compared to those of electron impact mass spectrometric ionisation, classically used for the determination of selenium. The negative chemical ionisation technique allowed accurate determination of total selenium by isotope dilution and of selenium isotope ratios in biological samples. The repeatability for total selenium and for stable isotope ratios was good (R.S.D.≤10%) within the range of 50 to 250 ng selenium. The detection limit for the investigated selenium isotopes was approximately 1 pg (signal to noise ratio at 3). The applicability of the developed stable isotope methodology was demonstrated by the determination of the selenium absorption and retention from foods in a pilot study using one human adult.  相似文献   

16.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs.  相似文献   

17.
Serum levels of 5-fluoro-2'-deoxyuridine in cancer treated patients were measured by gas chromatography mass spectrometry under chemical ionization conditions; 1-(2-deoxy-beta-D-lyxofuranosyl)-5-fluorouracil (3'-epi-5-fluoro-2'-deoxyuridine) was used as an internal standard. The drug and internal standard were quantitatively isolated from the serum sample by a mini-column anion exchange method and the extract permethylated using potassium-tert-butoxide in dimethylsulphoxide and methyl iodide. The derivatized nucleosides were then re-extracted from the reaction mixture and analysed on a glass capillary column coated with Superox-4. The column was coupled directly to the chemical ionization source of the mass spectrometer; NH3 was used as the reagent gas. The gas chromatographic effluent was monitored at m/z 289, the [MH]+ ion of the N,O-permethyl derivatives of 5-fluoro-2'-deoxyuridine and the internal standard. Recovery of 5-fluoro-2'-deoxyuridine from serum in the 0-1 microgram ml-1 concentration range averaged 93 +/- 2% (SD); a linear detector response was observed up to 50 ng 5-fluoro-2'-deoxyuridine ml-1. At the 10 ng ml-1 level, a within-run assay precision of 10% (CV) (n = 5) was found, while a detection limit of about 1 ng 5-fluoro-2'-deoxyuridine ml-1 of serum was attained. The method was applied to the measurement of disappearance curves of 5-fluoro-2'-deoxyuridine in the serum of treated patients.  相似文献   

18.
A quantitative method is reported for the determination of imipramine in plasma samples in the low nanogram and subnanogram range. The sensitivity and precision of the technique, which involves high pressure liquid chromatography and direct probe field ionization mass spectrometry, are approximately an order of magnitude greater than are offered by gas chromatography mass spectrometry with selected ion monitoring using deuterated or other types of internal standards. [2H6]Imipramine, labeled in the ethylene bridge and in the aromatic rings, serves as the isotopic diluent. The method has been used for the determination of the comparative bioavailabilities of two different commercial preparations of imipramine. In these tests, subjects ingested a 25 mg tablet of one or the other drug preparation together with a solution containing an equivalent amount of imipramine deuterated in the ethylene bridge ([2H2]imipramine). The latter served as an internal check for intrasubject variability in absorption of the imipramine tablets. Typical results from one of the subjects are presented.  相似文献   

19.
A sensitive analytical method was developed to characterize diclofenac metabolites in small amounts of body fluids. Desalted and lyophilized urine samples were extracted with supercritical carbon dioxide directly or after acidic hydrolysis. The extracts were derivatized with N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide. The derivatives were separated by capillary gas chromatography and identified by negative chemical ionization mass spectrometry. Full mass spectra were obtained at a level of 1·10−9 g/ml. With direct extraction, the metabolites could be analysed in one step as open-chained acids and as (cyclic) oxindoles. By acidic hydrolysis the conjugates were transformed to the oxindoles. With both methods, a new main metabolite, [2-[(2,6-dichloro-4-hydroxy-3-methoxyphenyl)amino]phenyl]acetic acid, was identified. The mechanism of its formation is discussed.  相似文献   

20.
A highly sensitive and specific assay for the quantification of thromboxane B2 (TXB2)(1) in human urine is described. The method is based on the use of low-blank (1H less than or equal to 0.2%) tetradeuterated internal standard 2 (18, 18, 19, 19-2H4-thromboxane B2), whose chemical synthesis is reported. After purification and high-performance liquid chromatography (HPLC) samples are derivatized to give an open-chain derivative of thromboxane B2, the methoxime pentafluorobenzyl ester tris(trimethylsilyl) ether (TXB2-MO-PFB-TMS3), most suitable for negative ion chemical ionization mass spectrometry. In the selected ion monitoring mode limits of detection per injection for pure standards and biological samples of 10 pg and 30 pg, respectively, are established. Normal urinary excretion of 1 in humans is 37-112 ng/24 h (n = 12).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号