首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeThe high incidence of defective ultrasound transducers in clinical practice has been shown in several studies. Recently, a novel method using only stored images for automatic detection of defective transducers was presented. The method makes it possible to remotely monitor many transducers at the same time and send a notification when a defective transducer is found. The purpose of the present study was to evaluate the novel method and assess how well it performs when compared to an established method as reference.MethodsTo evaluate the novel method, in-air images were collected from 81 transducers in radiologic departments in nine hospitals. Two observers assessed the in-air images and marked the defects. Receiver operating characteristic (ROC)- and alternative free response receiver operating characteristic (AFROC)-curves and their figures of merit (FOM) were calculated for the novel method, using marked defects in the in-air images as reference truth.ResultsThe area under the ROC curve was 0.88 (SD 0.06), and the AFROC FOM was 0.71 (SE 0.07).ConclusionThe result shows that the novel method has a good agreement with the in-air method for detecting defects in ultrasound systems. This indicates that the novel method could be a complement to the normal quality control for early, and automatic detection of defects.  相似文献   

2.
The aim of this study was to determine the diagnostic accuracy of swept‐source optical coherent tomography (SS‐OCT) in detecting and estimating the depth of proximal caries in posterior teeth in vivo. SS‐OCT images and bitewing radiographs were obtained from 86 proximal surfaces of 53 patients. Six examiners scored the locations according to a caries lesion depth scale (0–4) using SS‐OCT and the radiographs. The results were compared with clinical observations obtained after the treatment. SS‐OCT could detect the presence of proximal caries in tomograms that were synthesized based on the backscatter signal obtained from the proximal carious lesion through occlusal enamel. SS‐OCT showed significantly higher sensitivity and larger area under the receiver operating characteristic curve than radiographs for the detection of cavitated enamel lesions and dentin caries (Student's t ‐test, p < 0.05). SS‐OCT appears to be a more reliable and accurate method than bitewing radiographs for the detection and estimation of the depth of proximal lesions in the clinical environment. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

3.
The amount of sclerotic root dentine increases with age, proceeding from the apex towards the crown. There are obvious optical changes in the tissue, which becomes translucent (dentine is normally opaque). Therefore, the sclerosis of root dentine could be a reliable indicator of age in anthropological studies of human remains. We studied the histological aspects of sclerotic dentine in longitudinal thin sections (70-140 microns) of undecalcified premolars, cut in the bucco-lingual plane. To quantify the sclerosis and to construct a reference standard, we sectioned 85 premolars from subjects of known age (70 from odontological extractions and 15 from a university collection). Another 10 teeth from medieval subjects were studied to assess the applicability of the method to ancient skeletal collections. The technique consists of embedding the tooth in a polyester resin (cold method), sectioning it with a diamond blade microtome. Qualitative analysis was performed with polarized light microscopy and measurements were made with a quote 2D x,y viewer and on digital images. The sclerotic root dentine was quantified with both linear and surface area parameters in order to assess the correlation with age. The quality of the sections was sufficient for the clear discernment and quantification of the sclerotic dentine. Indeed, the technique allowed us to obtain good results with a considerable saving of time and money compared with other dental histological techniques. The best correlation with age was obtained from the surface area parameter, particularly after exclusion of the cementum and pulp chamber. To produce comparable data from similar studies, we advise the use of cold resins, as used here, and digital computerized analyzers because of their accuracy, precision and quickness. The qualitative analysis of the ancient teeth indications that this dental aging techniques can be applied to both recent and ancient dental tissues.  相似文献   

4.
An analysis of plain radiographs, digital subtraction arthrography, and radionuclide arthrography was performed in 25 revision hip arthroplasties to evaluate the efficacy and usefulness of these methods in the diagnosis of loosening. The findings by each method were compared with intraoperative assessment of the status of components and expressed in terms of sensitivity, specificity, and predictive accuracy. Overall accuracy for the acetabular component by plain radiographs was 80%; by digital subtraction arthrography, 88%; by radionuclide arthrography, 68%. Overall accuracy for the femoral component by plain radiographs was 92%; by digital subtraction arthrography, 84%; radionuclide arthrography, 76%. We consider subtraction arthrography and radionuclide arthrography to be adjuvant diagnostic tools which may be indicated in individual cases of suspected implant loosening of total hip arthroplasty. The routine use of these two methods is not warranted when compared to plain radiographs.  相似文献   

5.
IntroductionPerforming a CT acquisition along with a 18F-Fluoride PET study increases the effective dose delivered to the patient. We evaluated its value in the diagnosis of bone metastases.Material and methodsThree observers retrospectively analyzed 18F-Fluoride PET images (non-attenuation corrected) without CT and attenuation corrected images fused with CT in 50 patients with a cancer. The skeleton was divided into 17 areas. A score of malignancy from 1 to 5 was attributed to each area. An area-based analysis was done as well as a patient-based analysis. For the latter, the score of the area with the highest score was given to each patient. Clinical follow-up of at least 6 months, pathology or other imaging procedures served as gold standard.ResultsFor the three observers, the areas under the ROC curve of the area-based analysis were respectively 0.79, 0.97 and 0.70 without CT and 0.98, 0.98 and 0.96 with CT. The differences were significant (P < 0.05) for observers 1 and 3. The areas under the ROC curve of the patient-based analysis were respectively 0.86, 0.96 and 0.85 without CT and 0.97, 0.98 and 0.99 with CT and there was a significant difference for observer 3.ConclusionPerforming a CT acquisition along with an 18F-Fluoride PET study increases the homogeneity of the results obtained by different observers.  相似文献   

6.
Computed tomography allows cross-sectional imaging of anthropological as well as clinical subjects. Recently, technical innovations have made three-dimensional reconstruction of these images feasible. We performed two-dimensional and three-dimensional computed tomography of a Late Period Egyptian mummy to reexamine findings seen on previous radiographic studies and to evaluate the usefulness of these techniques in paleopathology. Two-dimensional images provided excellent anatomic detail. There was graphic depiction of the mummification process that corroborated information previously obtained from Egyptological studies. Three-dimensional reconstruction provided images of facial features as if the mummy had been unwrapped. Three-dimensional computed tomography is a useful method of nondestructively evaluating paleopathological remains, and it may yield information not obtainable by any other means.  相似文献   

7.
The accuracy of digital Roentgen stereophotogrammetric analysis (RSA) was compared to the accuracy of a manually operated RSA system. For this purpose, we used radiographs of a phantom and radiographs of patients. The radiographs of the patients consisted of double examinations of 12 patients that had a tibial osteotomy and of double examinations of 12 patients that received a total hip prosthesis. First, the radiographs were measured manually with an accurate measurement table. Subsequently, the images were digitized by a film scanner at 150 DPI and 300 DPI resolutions and analyzed with the RSA-CMS software. In the phantom experiment, the manually operated system produced significantly better results than the digital system, although the maximum difference between the median values of the manually operated system and the digital system was as low as 0.013 mm for translations and 0.033° for rotations. In the radiographs of the patients, the manually operated system and the digital system produced equally accurate results: no significant differences in translations and rotations were found. We conclude that digital RSA is an accurate, fast, and user friendly alternative for manually operated RSA. Currently, digital RSA systems are being used in a growing number of clinical RSA-studies.  相似文献   

8.
An experiment is described which compares the performance of a neural network to human performance on a visual task which consists of detecting a target in a background image of correlated noise. A three-layer, feed-forward, multi-layer perceptron is trained to indicate the presence or absence of a target in images also presented to human observers. The basis for the comparison between the network and the human observers is the receiver operating characteristic (ROC) curve. Network performance is comparable to human performance for this particular task.  相似文献   

9.
PurposeTo investigate whether a newly-developed single-energy metal artifact reduction (SEMAR) algorithm applied to images acquired on a 320-MDCT volume scanner reduces image artifacts from dental metal.MethodsWe inserted the lower right teeth covered with a dental metal alloy and crown in a skull phantom and performed single-volume scanning on a second-generation 320-MDCT scanner. A 12-mm diameter spherical lesion was placed either close to or far from the dental metal. The tube voltage and current were 120 kVp and 80 or 155 mA, respectively. Images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR), with or without SEMAR. We calculated the signal-to-artifact ratios (SAR) to quantify the visibility of the lesion. Two radiologists inspected 96 images (48 with lesion and 48 without) for the presence or absence of the lesion using a 5-point ordinal scale (1 = definitely absent to 5 = definitely present).ResultsOn images reconstructed with FPB and IR with SEMAR, streak artifacts from the dental metal were reduced substantially compared to images without SEMAR. At 155 mA with the lesion near the dental metal, the SARs were better on FBP and IR images (FBP: 1.7 and 0.5 with and without SEMAR, respectively; IR: 1.6 and 0.9 with and without SEMAR, respectively). The observer visual scores improved with SEMAR (FBP: 4.2 and 3.2 with and without SEMAR, respectively; IR: 4.2 and 3.0).ConclusionThe SEMAR algorithm reduces dental metal artifacts and improves lesion detectability and image quality in patients with oral cavity lesions.  相似文献   

10.
Congenital heart defects are known to be associated with facial dysmorphism and other congenital anomalies. Oculo-facio-cardio-dental (OFCD) syndrome is one such rare multiple congenital anomaly syndrome inherited as an X-linked dominant condition characterized by congenital cataracts, multiple minor facial dysmorphic features, congenital heart defects and dental anomalies. It is unrecognized by many medical and dental professionals. Only 21 cases have been reported so far. This syndrome is often misrecognized as rubella embryopathy because of association of congenital cataract with cardiac anomalies. It is usually the orthodontists who diagnose the syndrome based on typical findings on dental panoramic radiographs. But we suspected our patient to be having OFCD syndrome based on typical facial dysmorphism, ocular and cardiac defects, and finally it was confirmed after noticing typical dental radiographic findings.  相似文献   

11.
Arrest in long bone growth and the subsequent resumption of growth may be visible as radiopaque transverse lines in radiographs (Harris lines, HL; Harris, HA. 1933. Bone growth in health and disease. London: Oxford University Press). The assessment of individual age at occurrence of such lines, as part of paleopathological skeletal studies, is time-consuming and shows large intra- and interobserver variability. Thus, a standardized, automated detection algorithm would help to increase the validity of such paleopathological research. We present an image analysis application facilitating automatic detection of HL. On the basis of established age calculation methods, the individual age-at-formation can be automatically assessed with the tool presented. Additional user input to confirm the automatic result is possible via an intuitive graphical user interface. Automated detection of HL from digital radiographs of a sample of late Medieval Swiss tibiae was compared to the consensus of manual assessment by two blinded expert observers. The intra- and interobserver variability was high. The quality of the observer result improved when standardized detection criteria were defined and applied. The newly developed algorithm detected two-thirds of the HL that were identified as consensus lines between the observers. It was, however, necessary to validate the last one-third by manual editing. The lack of a large test series must be noted. The application is freely available for further testing by any interested researcher.  相似文献   

12.
There is disagreement as to whether clinical methods of caries diagnosis will produce reliable results in skeletal material, and studies vary greatly in the extent to which such methods are employed. The purpose of this study is, therefore, to evaluate the interobserver reliability of visual, tactile, and radiographic methods of scoring dental caries in ancient populations. Thirty-three individuals from a Mogollon skeletal sample were scored on three occasions by pairs of examiners. The first exam employed visual criteria alone. In the second exam, visual methods were supplemented with the dental explorer. For the third exam, mesial and distal surfaces were scored from “intraoral” radiographs. Examiners worked independently, but did calibrate on material from clinical populations prior to the second and third exams. Exams were conducted on a “blind” basis, and analysis was delayed until all exams were completed. Caries scores were expressed as a percentage of total surfaces present per individual. Repeat-measures ANOVA and intraclass correlation coefficients (ICC) were used to estimate interobserver reliabilities. For visual scores, ICC = 0.97, and there is no significant difference between examiners (P = 0.897). For visual plus explorer scores, ICC drops to 0.90, and there is a significant difference between examiners (P = 0.003). For the radiographs, ICC = 0.86, and there is no significant difference between observers (P = 0.117). These results suggest that clinical methods are less reliable in skeletal populations. Probable sources of error include postmortem dehydration of carious dentin, confusing radiolucencies engendered by worn or fractured enamel, and inadequate radiologic standards for root caries. These problems can be avoided through reliance on visual criteria.  相似文献   

13.
Increases in the distance from the cemento-enamel junction to the alveolar crest (CEJ-AC) have often been attributed to senile atrophy of the bone or to the effects of periodontitis, without reference to the condition of the alveolar crest. This study investigated the relationship between CEJ-AC distance, tooth wear, gender, site of the CEJ-AC measurements, and age in 161 pre-white-contact Australian aboriginal skulls. Individual teeth were included in the study when there was no evidence of dehiscence, periodontitis, or abscess cavity formation in the supporting alveolar bone. The CEJ-AC distances increased as the severity of attrition increased; in male skulls, CEJ-AC distances were greater than in female skulls for all categories of tooth wear. In general, CEJ-AC distances measured on the mesial aspects of teeth were greater than those recorded distally; lingual distances generally exceeded buccal recordings. The best explanation of these findings and similar reports in the anthropological literature is that continuous tooth eruption occurred without the concomitant coronal movement of alveolar bone. This conclusion has significant ramifications for anthropological, epidemiological, and clinical studies which use the CEJ and AC as reference points when measuring periodontal attachment loss (periodontitis).  相似文献   

14.
Modern micro-computed tomography techniques allow the accurate visualization of internal dental structures, and are becoming widely used within (paleo-) anthropological dental studies. There exist several types and name brands of microtomographic systems, however, which have been demonstrated to produce images that vary in resolution and signal-to-noise ratio. As a growing body of dental research using disparate microtomographic techniques is likely to continue accumulating, it is imperative that different systems are compared to ensure that results are comparable and not machine-dependent. In the present study, we compare volume, surface area, and linear measurements recorded on a sample of modern and fossil teeth using four microtomographic systems (three laboratory scanners, and the ID19 beamline of the European Synchrotron Radiation Facility). Results indicate that measurements are comparable between systems (within 3%), but that synchrotron radiation is superior to the other systems because its monochromatic X-rays prevent beam hardening and its parallel beam prevents geometric artifacts in the resultant images, making it easier to record measurements and see fine details at the enamel cervix or dentine horn tips. Although the synchrotron produces higher resolution images with less artifacts, results indicate that for gross morphological measurements (e.g., enamel cap volume, intercuspal distances), each of the scanners produces approximately the same measurements. Combining measurements of teeth from multiple microCT systems presupposes that measurements from each system are comparable; the research presented here indicates that this is the case when teeth are not severely diagenetically remineralized.  相似文献   

15.
Single energy X-ray imaging, due to its low cost and flexibility, is one of the most used and common technique to assess bone state and bone remodeling over time. Standardized X-ray images are needed to compare sets of radiographs for semi-quantitative analyses of tissue remodeling. However, useful mathematical modeling for the analysis of high level radiographic images are not easily available. In order to propose a useful evaluation tool to a wide clinical scenario, we present an innovative calibration algorithm for a semi-quantitative analysis of non-standardized digitized X-ray images. For calibration on a unique standardization scale, three time invariant regions (ROI) of radiographs were selected and analyzed. The accuracy of the normalization method for X-ray films was successfully validated by using an aluminum step wedge for routine X-ray exposures as tool to standardize serial radiographs (Pearson correlation test: R(2) = 0.96). This method was applied to investigate the progression of the new bone deposition within ceramic scaffolds used as osteoconductive substitute in large bone defects taking advantage of a large animal model. This innovative image-processing algorithm allowed the identification and semi-quantification of the bone matrix deposited within the implant. The osteo-integration at the bone-implant interface was also investigated. A progressively increasing bone tissue deposition within the porous bioceramic implant and a progressive osteo-integration was observed during the 12 months of the trial.  相似文献   

16.
Despite the increasing number of techniques for the preservation of bone ridges after dental avulsion, no precise evaluation of alveolar filling has been performed to date. The criteria of available measurement techniques (probes, retroalveolar or panoramic radiography, and lateral teleradiography) are not sufficiently reliable and precise. This study investigated the reliability of evaluation based on CT images in comparison with retroalveolar radiography (the most precise radiographic technique, providing standardised images), direct measurements, and images obtained in scanning electron microscopy. After a preliminary investigation ex vivo, a study was performed in vivo on three beagles. Mandibular premolars were extracted, and the corresponding alveoli were filled with an injectable bone substitute composed of a calcium phosphate mineral load associated with hydroxypropyl methylcellulose. Measurements performed on CT images relative to visual and automatic detection of density changes and studies of density curves provided better precision than those obtained by retroalveolar radiography.  相似文献   

17.
This paper reports the findings of a study designed to examine observer variation as a source of inaccuracy inherent in the use of computer-assisted image analysis to measure areas of stained tissue. The rat pituitary immunostained for prolactin and galanin was used as an example to estimate patterns of immunoreactivity exhibited by different cell types. Six observers, with differing experience, selected grey level threshold values on 40 fields of images of stained tissue making three repeats of each field. The 40 fields consisted of 20 serial pairs of colocalized fields, one immunostained for prolactin, the other for galanin. The 20 pairs consisted of four pairs from each of five animals. Analysis of observer variation in the selection of threshold values showed large differences in the within- and between-observer variation. Analysis of the components of variance in the estimation of the ratios of stained tissues showed that the major source of variation was the within-observer component. An additional experiment using two observers, where half of the images were compared to the original microscope images before setting threshold levels, showed that the opportunity to make a comparison did not reduce observer variation. It is suggested that any study which uses semi-automatic methods to segment regions of a digital image can benefit from an analysis of this kind so that the sources of variation can be determined to enable maximum discriminating power in future studies.  相似文献   

18.
Quantitative analysis of radiographs can be a very difficult and time-consuming task. Compounding this problem is a lack of standardization of films in a sequence of radiographs. Differences in magnification from film to film makes comparisons of parameters measured directly from the films virtually impossible. The system described in this paper allows for rapid comparison of non-standardized radiographs. In particular this system allows rapid measurements of alveolar ridge heights at 10 points on each side of a patient's face. Provisions allow for both mandibular and maximally studies, for reporting of means and standard deviations for each interval in a series, as well as for comparisons between intervals in a clinical sequence. Finally, graphic display allowing super-imposition of separate radiographs is possible, giving visual realization of clinically important changes in a patient's status.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号