首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 748 毫秒
1.
In this work, we conceive and demonstrate the magneto-electric double Fano resonances of a hetero-cavity composed of Si disk and Au split ring, where Si disk can provide additional magnetic responses besides electric responses. The interference between electric and magnetic responses in proposed hetero-cavity gives rise to magneto-electric double Fano resonances with magnetic and electric near-field enhancements. Dipole radiative enhancement is used to analyze magnetic and electric responses of hetero-cavity and the spectral features of hetero-cavity can be used to quantitatively characterize by coupled oscillator model. And the spectral tunability of magneto-electric double Fano resonances is investigated, highlighting a potential for applications in low-loss sensing and nanophotonic devices.  相似文献   

2.
While the differentiation factors have been widely used to differentiate mesenchymal stem cells (MSCs) into various cell types, they can cause harm at the same time. Therefore, it is beneficial to propose methods to differentiate MSCs without factors. Herein, magnetoelectric (ME) nanofibers were synthesized as the scaffold for the growth of MSCs and their differentiation into neural cells without factors. This nanocomposite takes the advantage of the synergies of the magnetostrictive filler, CoFe2O 4 nanoparticles (CFO), and piezoelectric polymer, polyvinylidene difluoride (PVDF). Graphene oxide nanosheets were decorated with CFO nanoparticles for a proper dispersion in the polymer through a hydrothermal process. After that, the piezoelectric PVDF polymer, which contained the magnetic nanoparticles, underwent the electrospun process to form ME nanofibers, the ME property of which has the potential to be used in areas such as tissue engineering, biosensors, and actuators.  相似文献   

3.
Internet of Things (IoT) is driving the development of new generation of sensors, communication components, and power sources. Ideally, IoT sensors and communication components are expected to be powered by sustainable energy source freely available in the environment. Here, a breakthrough in this direction is provided by demonstrating high output power energy harvesting from very low amplitude stray magnetic fields, which exist everywhere, through magnetoelectric (ME) coupled magneto‐mechano‐electric (MME) energy conversion. ME coupled MME harvester comprised of multiple layers of amorphous magnetostrictive material, piezoelectric macrofiber composite, and magnetic tip mass, interacts with an external magnetic field to generate electrical energy. Comprehensive experimental investigation and a theoretical model reveal that both the magnetic torque generated through magnetic loading and amplification of magneto‐mechanical vibration by ME coupling contributes toward the generation of high electrical power from the stray magnetic field around power cables of common home appliances. The generated electrical power from the harvester is sufficient for operating microsensors (gyro, temperature, and humidity sensing) and wireless data transmission systems. These results will facilitate the deployment of IoT devices in emerging intelligent infrastructures.  相似文献   

4.
Electric fields, which are ubiquitous in the context of neurons, are induced either by external electromagnetic fields or by endogenous electric activities. Clinical evidences point out that magnetic stimulation can induce an electric field that modulates rhythmic activity of special brain tissue, which are associated with most brain functions, including normal and pathological physiological mechanisms. Recently, the studies about the relationship between clinical treatment for psychiatric disorders and magnetic stimulation have been investigated extensively. However, further development of these techniques is limited due to the lack of understanding of the underlying mechanisms supporting the interaction between the electric field induced by magnetic stimulus and brain tissue. In this paper, the effects of steady DC electric field induced by magnetic stimulation on the coherence of an interneuronal network are investigated. Different behaviors have been observed in the network with different topologies (i.e., random and small-world network, modular network). It is found that the coherence displays a peak or a plateau when the induced electric field varies between the parameter range we defined. The coherence of the neuronal systems depends extensively on the network structure and parameters. All these parameters play a key role in determining the range for the induced electric field to synchronize network activities. The presented results could have important implications for the scientific theoretical studies regarding the effects of magnetic stimulation on human brain.  相似文献   

5.
Transcranial magnetic stimulation (TMS) is a stimulation method in which a magnetic coil generates a magnetic field in an area of interest in the brain. This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain. Although TMS has been used for several decades, the biophysical basis underlying the stimulation of neurons in the central nervous system (CNS) is still unknown. To address this problem we developed a numerical scheme enabling us to combine realistic magnetic stimulation (MS) with compartmental modeling of neurons with arbitrary morphology. The induced electric field for each location in space was combined with standard compartmental modeling software to calculate the membrane current generated by the electromagnetic field for each segment of the neuron. In agreement with previous studies, the simulations suggested that peripheral axons were excited by the spatial gradients of the induced electric field. In both peripheral and central neurons, MS amplitude required for action potential generation was inversely proportional to the square of the diameter of the stimulated compartment. Due to the importance of the fiber's diameter, magnetic stimulation of CNS neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. Passive dendrites affect this process primarily as current sinks, not sources. The simulations predict that neurons with low current threshold are more susceptible to magnetic stimulation. Moreover, they suggest that MS does not directly trigger dendritic regenerative mechanisms. These insights into the mechanism of MS may be relevant for the design of multi-intensity TMS protocols, may facilitate the construction of magnetic stimulators, and may aid the interpretation of results of TMS of the CNS.  相似文献   

6.
Experimental data on calcium-ion release in chicken brain tissue suggest that biological effects of electric and magnetic fields (EMFs) are concentrated near certain “active combinations” of DC magnetic field strength and “effective” AC magnetic field frequencies. We hypothesize that active AC/DC combinations may exist and suggest that epidemiologic data, coupled with DC magnetic field measurements, may be used to identify critical exposure conditions. An empirical model is used to calculate these multiple active combinations at any given DC magnetic field strength and to define a rating system that incorporates the proximity of AC magnetic field frequencies generated by electric power lines to the new, computed effective frequencies. Such an exposure score may be useful in investigating correlations of EMF exposure with disease incidence. For 60 Hz and 50 Hz, the highest EMF exposure scores occurred at DC field strengths of 506 mG and 422 mG, respectively. The exposure score contains a factor which may be adjusted to reflect the importance of harmonics of the AC magnetic field as well as of the fundamental frequency. Using this factor, we consider two important special cases consistent with chick brain data: 1) we consider active pairs associated with all detectable harmonics (up to 660 Hz) without regard to relative intensity of the harmonics, and 2) we use the relative intensities of the AC field frequencies to adjust their contribution to the exposure score. © 1993 Wiley-Liss. Inc.  相似文献   

7.
Deep Brain Stimulation (DBS) is increasingly used to treat a variety of brain diseases by sending electrical impulses to deep brain nuclei through long, electrically conductive leads. Magnetic resonance imaging (MRI) of patients pre- and post-implantation is desirable to target and position the implant, to evaluate possible side-effects and to examine DBS patients who have other health conditions. Although MRI is the preferred modality for pre-operative planning, MRI post-implantation is limited due to the risk of high local power deposition, and therefore tissue heating, at the tip of the lead. The localized power deposition arises from currents induced in the leads caused by coupling with the radiofrequency (RF) transmission field during imaging. In the present work, parallel RF transmission (pTx) is used to tailor the RF electric field to suppress coupling effects. Electromagnetic simulations were performed for three pTx coil configurations with 2, 4, and 8-elements, respectively. Optimal input voltages to minimize coupling, while maintaining RF magnetic field homogeneity, were determined for all configurations using a Nelder-Mead optimization algorithm. Resulting electric and magnetic fields were compared to that of a 16-rung birdcage coil. Experimental validation was performed with a custom-built 4-element pTx coil. In simulation, 95-99% reduction of the electric field at the tip of the lead was observed between the various pTx coil configurations and the birdcage coil. Maximal reduction in E-field was obtained with the 8-element pTx coil. Magnetic field homogeneity was comparable to the birdcage coil for the 4- and 8-element pTx configurations. In experiment, a temperature increase of 2±0.15°C was observed at the tip of the wire using the birdcage coil, whereas negligible increase (0.2±0.15°C) was observed with the optimized pTx system. Although further research is required, these initial results suggest that the concept of optimizing pTx to reduce DBS heating effects holds considerable promise.  相似文献   

8.
We prove that, at the frequencies generally proposed for extracranial stimulation of the brain, it is not possible, using any superposition of external current sources, to produce a three-dimensional local maximum of the electric field strength inside the brain. The maximum always occurs on a boundary where the conductivity jumps in value. Nevertheless, it may be possible to achieve greater two-dimensional focusing and shaping of the electric field than is currently available. Towards this goal we have used the reciprocity theorem to present a uniform treatment of the electric field inside a conducting medium produced by a variety of sources: an external magnetic dipole (current loop), an external electric dipole (linear antenna), and surface and depth electrodes. This formulation makes use of the lead fields from magneto- and electroencephalography. For the special case of a system with spherically symmetric conductivity, we derive a simple analytic formula for the electric field due to an external magnetic dipole. This formula is independent of the conductivity profile and therefore embraces spherical models with any number of shells. This explains the "insensitivity" to the skull's conductivity that has been described in numerical studies. We also present analytic formulas for the electric field due to an electric dipole, and also surface and depth electrodes, for the case of a sphere of constant conductivity.  相似文献   

9.
脑深部电刺激已成为许多神经和精神疾病的有效治疗方法。然而,侵入性的电极植入会带来手术并发症的风险,并且刺激靶区在植入后很难改变。经颅磁刺激和经颅电刺激等非侵入性刺激方法为调节大脑功能提供了新的途径。但是,尚未证明这些非侵入性脑刺激方法可以直接调节脑深部神经元活动而不影响皮层神经元。因此,这些方法主要用于调节大脑表层脑区的神经活动。时域相干(temporal interference,TI)刺激是通过两个高频电场相互作用,产生低频包络调节神经活动的一种非侵入式脑深部电刺激的新方法,该方法有望解决无创脑深部刺激的需求。本文首先介绍TI刺激的概念以及安全性,然后阐述TI刺激现有研究中的电场分析方法,并讨论电场分析相关的生理模型建模方法和仿真平台以及TI刺激诱发场分布的研究进展与在动物和人体中的应用进展。最后,本文展望了TI刺激技术未来发展方向,以期为无创脑深部刺激研究提供新的研究思路。  相似文献   

10.
The goal of the research reported here is to narrow the range of uncertainty about peripheral nerve stimulation (PNS) thresholds associated with whole body magnetic field exposures at 50/60 Hz. This involved combining PNS thresholds measured in human subjects exposed to pulsed magnetic gradient fields with calculations of electric fields induced in detailed anatomical models of the body by that same exposure system. PNS thresholds at power frequencies (50/60 Hz) can be predicted from these data due to the wide range of pulse durations (70 mus to 1 ms), the length of the pulse trains (several tens of ms), and the exposure of a large part of the body to the magnetic field. These data together with the calculations of the rheobase electric field exceeded in 1% (E(1%)) of two anatomical body models, lead to a median PNS detection threshold of 47.9 +/- 4.4 mT for a uniform 60 Hz magnetic field exposure coronal to the body. The threshold for the most sensitive 1% of the population is about 27.8 mT. These values are lower than PNS thresholds produced by magnetic fields with sagittal and vertical orientations or nonuniform exposures.  相似文献   

11.

In this theoretical study, optical properties of a thin slab including graphite nanoparticles doped in a host medium such as silica and silicon have been investigated. A constant magnetic field is used for controlling Fresnel coefficients of the slab. Depending on the direction of the normal vector of the basal plane of the graphite structure with respect to the electric field of the incident electromagnetic wave (perpendicular or parallel), optical behavior of graphite is different. Electric permittivity of an individual magnetized graphite nanoparticle is calculated by a semi-empirical Drude-like model for both kinds of the normal vector of the basal plane orientation. By means of well-known Maxwell-Garnett theory, effective permittivity of the magnetized nanocomposite slab is obtained. It is shown that at the mid-IR frequency range, exerting a magnetic field of few hundred Tesla can lead to the substantial variations of Fresnel coefficients. Effect of the magnetic field on the optical properties of the slab is more evident when the population of the graphite nanoparticles with the parallel orientation of the basal plane is increased.

  相似文献   

12.
Transcranial magnetic stimulation: a primer   总被引:4,自引:0,他引:4  
Hallett M 《Neuron》2007,55(2):187-199
Transcranial magnetic stimulation (TMS) is a technique for noninvasive stimulation of the human brain. Stimulation is produced by generating a brief, high-intensity magnetic field by passing a brief electric current through a magnetic coil. The field can excite or inhibit a small area of brain below the coil. All parts of the brain just beneath the skull can be influenced, but most studies have been of the motor cortex where a focal muscle twitch can be produced, called the motor-evoked potential. The technique can be used to map brain function and explore the excitability of different regions. Brief interference has allowed mapping of many sensory, motor, and cognitive functions. TMS has some clinical utility, and, because it can influence brain function if delivered repetitively, it is being developed for various therapeutic purposes.  相似文献   

13.
Extracellular electric fields existing throughout the living brain affect the neural coding and information processing via ephaptic transmission, independent of synapses. A two-compartment whole field effect model (WFEM) of pyramidal neurons embedded within a resistive array which simulates the extracellular medium i.e. ephapse is developed to study the effects of electric field on neuronal behaviors. We derive the two linearized filed effect models (LFEM-1 and LFEM-2) from WFEM at the stable resting state. Through matching these simplified models to the subthreshold membrane response in experiments of the resting pyramidal cells exposed to applied electric fields, we not only verify our proposed model’s validity but also found the key parameters which dominate subthreshold frequency response characteristic. Moreover, we find and give its underlying biophysical mechanism that the unsymmetrical properties of active ion channels results in the very different low-frequency response of somatic and dendritic compartments. Following, WFEM is used to investigate both direct-current (DC) and alternating-current field effect on the neural firing patterns by bifurcation analyses. We present that DC electric field could modulate neuronal excitability, with the positive field improving the excitability, the modest negative field suppressing the excitability, but interestingly, the larger negative field re-exciting the neuron back into spiking behavior. The neuron exposed to the sinusoidal electric field exhibits abundant firing patterns sensitive to the input frequency and intensity. In addition, the electrical properties of ephapse can modulate the efficacy of field effect. Our simulated results are qualitatively in line with the relevant experimental results and can explain some experimental phenomena. Furthermore, they are helpful to provide the predictions which can be tested in future experiments.  相似文献   

14.
Liposomes are one of the most promising biomaterial carriers to deliver DNA,(1) proteins, drugs and medicine in human bodies. However, artificially formed liposomes have to satisfy some crucial functions such as: (i) to efficiently carry drugs to targeted systems, (ii) to be biologically stable until they are removed from human body, (iii) to be biodegradable, and (iv) to be sufficiently small in size for effective drug delivery. Here, we report an efficient and novel method to simultaneously manufacture and incorporate super-paramagnetic iron-oxide nanoparticles (efficient target finder in the presence of external magnetic field) into the liposome's interior and its bilayer. In this technique, we use electric field to control the formation of liposomes and the incorporation of iron oxide nanoparticles. Our preparation procedure does not require any chemical or ultrasound treatments. Apart from that, we also provide further experimental investigations on the role of electric fields on the formation of liposomes using XPS(2) and the magnetic-optical microscope.  相似文献   

15.
We have studied the linear electric field effect in pulsed EPR of the "EPR-detectable copper" signal of beef heart cytochrome c oxidase and have compared our results with those for a variety of square planar and tetrahedral Cu(II) model compounds and with Cu(II) proteins containing either type 1 or type 2 copper. The electric field induced g shifts (linear electric field effect) for cytochrome oxidase are comparable in magnitude to those for simple Cu(II) complexes and for some copper proteins containing type 2 sites. The shifts are smaller than those for tetrahedral copper complexes and for type 1 copper sites. However, the magnetic field dependence of the linear electric field effect does not resemble that observed for any Cu(II) complex studied nor for type 1 copper. These findings cannot be reconciled with the tetrahedral Cu(II) model proposed by Greenaway, Chan, and Vincow ((1977) Biochim. Biophys. Acta 490, 62-78, 1977) to explain the unusual EPR spectrum of cytochrome oxidase.  相似文献   

16.
Our previous experiments indicated an age- and sex-dependent functional lateralization of a high-affinity choline uptake system in hippocampi of Wistar rats. The system is connected with acetylcholine synthesis and also plays a role in spatial navigation. The current study demonstrates that a single in vivo exposure of 7- or 14-day-old males to a static magnetic field of 0.14 T for 60–120 min evokes asymmetric alterations in the activity of carriers in adulthood. Namely, the negative field (antiparallel orientation with a vertical component of the geomagnetic field) mediated a more marked decrease in the right hippocampus. The positive field (parallel orientation) was ineffective. Moreover, differences between the carriers from the right and the left hippocampi were observed on synaptosomes pretreated with superparamagnetic nanoparticles and exposed for 30 min in vitro. The positive field enhanced more markedly the activity of carriers from the right hippocampus, the negative that from the left hippocampus, on the contrary. Our results demonstrate functionally teratogenic risks of the alterations in the orientation of the strong static magnetic field for postnatal brain development and suggest functional specialization of both hippocampi in rats. Choline carriers could be involved as secondary receptors in magnetoreception through direct effects of geomagnetic field on intracellular magnetite crystals and nanoparticles applied in vivo should be a useful tool to evaluate magnetoreception in future research.  相似文献   

17.
经颅电刺激技术是一种非侵入性神经调控方法,因其具有卓越的安全性、良好的患者依从性以及高度便携性等特点,被视为一种潜在的非药物镇痛手段。然而,目前对于经颅电刺激镇痛效果的研究结果不一致且镇痛机制尚未完全阐明。本文通过系统归纳总结3种主要的经颅电刺激技术——经颅直流电刺激、经颅交流电刺激和经颅随机噪声刺激——在镇痛领域的研究进展,评估了这些技术对短时、急性和慢性疼痛的镇痛效果,并深入剖析了其潜在的镇痛机制。同时,本文系统讨论了既往研究的局限性,并对未来研究提出了一系列切实可行的建议,如借助电场模拟技术实现个性化刺激以克服不同个体头部解剖结构差异的影响、应用多位点刺激和深部脑刺激技术来拓展刺激脑区、搭建经颅电刺激技术同步神经影像平台以制定个体特异性的刺激方案并深入揭示其镇痛机制、探索与其他治疗技术的联合应用以提高疗效等。这些建议的实施将有助于解决当前研究中存在的问题,充分发挥经颅电刺激在疼痛治疗中的临床价值,最终实现患者疼痛的缓解。  相似文献   

18.
We seek to extend the recent suggestion that classical cyclotron resonance of biologically important ions is implicated in weak electromagnetic field-cell interactions. The motion of charged particles in a constant magnetic field and periodic electric field is examined under the simplifying assumption of no damping. Each of the nine terms of the relative dielectric tensor is found to have a dependence on functions that include the factor (omega 2 - omega 2B)-1, where omega B is the gyrofrequency. We also find a plasmalike decomposition of the electric field into oppositely rotating components that could conceivably act to drive oppositely charged ions in the same direction through helical membrane channels. For weak low-frequency magnetic fields, an additional feature arises, namely, periodic reinforcement of the resonance condition with intervals of the order of tens of msec for biological ions such as Li+, Na+, and K+.  相似文献   

19.
Source localization based on magnetoencephalographic and electroencephalographic data requires knowledge of the conductivity values of the head. The aim of this paper is to examine the influence of compartment conductivity changes on the neuromagnetic field and the electric scalp potential for the widely used three compartment boundary element models. Both the analysis of measurement data and the simulations with dipoles distributed in the brain produced two significant results. First, we found the electric potentials to be approximately one order of magnitude more sensitive to conductivity changes than the magnetic fields. This was valid for the field and potential topology (and hence dipole localization), and for the amplitude (and hence dipole strength). Second, changes in brain compartment conductivity yield the lowest change in the electric potentials topology (and hence dipole localization), but a very strong change in the amplitude (and hence in the dipole strength). We conclude that for the magnetic fields the influence of compartment conductivity changes is not important in terms of dipole localization and strength estimation. For the electric potentials however, both dipole localization and strength estimation are significantly influenced by the compartment conductivity.  相似文献   

20.
Magnetotactic bacteria (MTB) build magnetic nanoparticles in chain configuration to generate a permanent dipole in their cells as a tool to sense the Earth’s magnetic field for navigation toward favorable habitats. The majority of known MTB align their nanoparticles along the magnetic easy axes so that the directions of the uniaxial symmetry and of the magnetocrystalline anisotropy coincide. Desulfovibrio magneticus sp. strain RS-1 forms bullet-shaped magnetite nanoparticles aligned along their (100) magnetocrystalline hard axis, a configuration energetically unfavorable for formation of strong dipoles. We used ferromagnetic resonance spectroscopy to quantitatively determine the magnetocrystalline and uniaxial anisotropy fields of the magnetic assemblies as indicators for a cellular dipole with stable direction in strain RS-1. Experimental and simulated ferromagnetic resonance spectral data indicate that the negative effect of the configuration is balanced by the bullet-shaped morphology of the nanoparticles, which generates a pronounced uniaxial anisotropy field in each magnetosome. The quantitative comparison with anisotropy fields of Magnetospirillum gryphiswaldense, a model MTB with equidimensional magnetite particles aligned along their (111) magnetic easy axes in well-organized chain assemblies, shows that the effectiveness of the dipole is similar to that in RS-1. From a physical perspective, this could be a reason for the persistency of bullet-shaped magnetosomes during the evolutionary development of magnetotaxis in MTB.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号