1.
Glucosamine is an amino monosaccharide reagent. It is difficult to assay using typical reversed-phase column due to the early elution, by optimizing the chromatographic conditions, especially the analytical column and the mobile phase composition, an improved analytical method was developed and validated, which offers rapid, sensitive and specific determination of glucosamine in human plasma. Following protein precipitation, the analyte and internal standard (valibose) were separated using an isocratic mobile phase on an Inertsil CN-3 column and detected by mass spectrometry in the multiple reaction monitoring mode using the respective precursor to product ion combinations of m/z 180/72 for glucosamine and m/z 252/198 for valibose. The chromatographic time was just 4.2 min for each sample, which made it possible to analyze more than 120 human plasma samples per day. The method exhibited a linear dynamic range of 4.00-4000 ng/mL for glucosamine in human plasma. The lower limit of quantification (LLOQ) was 4.00 ng/mL with a relative standard deviation of less than 10.9%. Acceptable precision and accuracy were obtained for the plasma concentrations over the standard curve range. By monitoring the two different MRM transitions, it was proved that no endogenous glucosamine was found in human plasma. The validated method has been successfully used to analyze human plasma samples for application in a bioequivalence study.  相似文献   

2.
A sensitive and specific HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma has been developed and validated. Plasma samples were analyzed after a simple, one-step protein precipitation clean-up with trichloroacetic acid using a polymer-based amino high-performance liquid chromatography (HPLC) column and a water/acetonitrile mobile phase elution gradient, with d-[1-(13)C]glucosamine as the internal standard. Detection was performed by mass spectrometry, using an electrospray source and employing multiple reaction monitoring to separately monitor glucosamine and the internal standard. The limit of quantification of the method was 10ng/ml of glucosamine and the calibration curve showed a good linearity up to 1000ng/ml. The precision (R.S.D.) and the accuracy (bias) of the method at the limit of quantification were 13.8 and 4.0%, respectively, and the mean recovery of glucosamine at three concentration levels was 101.6+/-5.7%. The method was applied for the determination of glucosamine concentrations in human plasma samples collected from untreated healthy volunteers and, in a separate bioavailability study, to evaluate plasma glucosamine pharmacokinetics profiles after oral administration of crystalline glucosamine sulfate.  相似文献   

3.
A simple, rapid, selective and specific high-performance liquid chromatography (HPLC) method with fluorescence detection was developed for determination of glucosamine sulfate in human plasma and application to a bioequivalence in healthy volunteers. Precipitation of plasma was accomplished with acetonitrile to separate interfering endogenous products from the compound of interest. After vortex mixing and centrifugation, the supernatant was transferred and derivatized with 9-fluorenylmethoxycarbonyl chloride-acetonitrile solution in borate buffer (pH=8.0) at 30 degrees C for 30 min. The chromatographic separation was performed on a Diamonsil C18 column (150.0 mmx4.6 mm, 5 microm) with a mobile phase gradient consisting of water and acetonitrile at a flow rate of 1 mL/min. The method was linear in the range of 0.1-10.0 microg/mL with a correlation coefficient (r) of 0.9996. The limit of detection was 15 ng/mL. Inter- and intra-day precisions were 相似文献   

4.
A two‐dimensional HPLC method based on the direct injection of biological samples has been developed and validated for the determination of lansoprazole enantiomers in human plasma. The lansoprazole enantiomers were extracted from the biological matrix using an octyl restricted access media bovine serum albumin column (C8 RAM BSA) and the enantioseparation was performed on an amylose tris(3,5‐dimethoxyphenylcarbamate) chiral column using acetonitrile:water (35:65 v/v) and UV detection at 285 nm. Analysis time was 25 min with no time spent on sample preparation. The method was applied to the analysis of the plasma samples obtained from nine Brazilian volunteers who received a 30 mg oral dose of racemic lansoprazole and was able to quantify the enantiomers of lansoprazole in the clinical samples analyzed. Chirality 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

5.
目的:选择一种能准确测定天可力氨糖胶囊中氨基葡萄糖硫酸钾含量的方法。方法:参照GB/T 20365-2006硫酸软骨素和盐酸氨基葡萄糖含量的方法进行液相色谱法测定以及利用盐酸氨基葡萄糖Fdson—Morgan反应后在525 nm左右波长处有吸收峰,测定其吸收值与标准品比较进行比色定量。结果:液相色谱法测定时胶囊中的其它中药成分干扰很大,数据偏差太大;而比色法测定时,氨基葡萄糖盐酸盐含量在175μg/mL浓度范围内,呈良好线性关系:Y(μg/mL)=0.196X-O.004,R=0.997,平均回收率102.09%。结论:该比色法测定方法灵敏、准确、简便,可供天可力氨糖胶囊中氨基葡萄糖硫酸钾含量测定。  相似文献   

6.
Glucosamine is used for alleviating pain in osteoarthritis. Clinical trials have reported that glucosamine has equivocal efficacy. Glucosamine is also used in cell cultures to stimulate hexosamine flux and protein O-glycosylation, but at many-fold greater concentrations than those in human plasma following oral dosing. Lean Zucker rats were dosed orally for 6 weeks with glucosamine hydrochloride at doses (0–600 mg/kg/day) that produced peak serum concentrations of <1–35 μM, spanning the human exposure range. Relative expression of both TGFβ1 and CTGF mRNA were significantly increased up to 2.3-fold in liver, kidney and articular cartilage when evaluated 4 h after final dose. Apparent threshold serum glucosamine (Cmax) concentration required to increase TGFβ1 expression in cartilage was 10–20 μM. These increases were associated with significant increases in UDP-N-acetylglucosamine concentrations suggesting increased hexosamine flux. Both TGFβ1 and CTGF are mediators of chondrocyte proliferation and cartilage repair. Study demonstrates that oral glucosamine doses that produce clinically relevant serum glucosamine concentrations can induce tissue TGFβ1 and CTGF expression in vivo and provides a mechanistic rationale for reported beneficial effects of glucosamine therapy. Induction of renal TGFβ1 and CTGF mRNA suggests that potential sclerotic side-effects may occur following consumption of potent glucosamine preparations.  相似文献   

7.
A simple, sensitive and selective spectrofluorimetric method has been developed for the determination of tobramycin (TOB) in human serum and pharmaceutical preparations. The method is based on the reaction between the primary amino group of TOB and fluorescamine in borate buffer, pH 8.5, to give a highly fluorescent derivative which is measured at 469 nm after excitation at 388 nm. The fluorescence intensity was directly proportional to the concentration over the range 300–1500 ng/mL, with a limit of detection of 65 ng/mL and limit of quantitation of 215 ng/mL. All variables were investigated to optimize the reaction conditions. The method was validated according to International Conference on Harmonization guidelines in terms of specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. Good recoveries were obtained ranging from 97.4 to 100.64%, indicating that no interference was observed from concomitants usually present in pharmaceutical dosage forms. The method was successfully, applied for the analysis of the drug substance in its pharmaceutical preparations and spiked serum samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and sensitive flow injection chemiluminescence method has been developed for the determination of ferulic acid (FA) based on the significant enhancement effect of FA on the CL signal of the N‐bromobutanimide (NBS)–eosin–CrCl3 system in alkaline solution. Under optimum conditions, the enhanced CL intensity is linearly related to the concentration of FA in its pharmaceutical preparations and human plasma samples. The corresponding linear regression equations were established over the 4.0 × 10–10–1.0 × 10–7 g/mL for FA tablets and 2.0 × 10–10–1.0 × 10–7 g/mL for plasma samples. The limit of detection for FA tablets and limit of quantification for plasma samples were 2.8 × 10–10 g/mL (3 σ) and 3.04 × 10–10 g/mL (10 σ), respectively. A complete analysis could be performed within 40 s, including washing and sampling, giving a throughput of ≈90/h. The proposed method was successfully applied to the determination of FA in pharmaceutical preparations and human plasma samples with satisfactory results. The recoveries of pharmaceutical preparations and human plasma samples at three different concentrations were 97.8–102.6% and 96.7–104.0%, respectively. Furthermore, the possible mechanism of CL reactions was also discussed briefly. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Sensitive and selective methods based on high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection were developed for the determination of vitamin D(3) in human serum. Derivatization of vitamin D(3) and its stable isotope labeled internal standard provided highly sensitive quantification and selective detection from endogenous compounds. Samples were prepared using the in-tube liquid-liquid extraction (LLE), 96-well plate LLE, and in-tip solid phase micro-extraction (SPME) in 96-well format. In all methods, the MS/MS detection was performed using Applied Biosystems-Sciex API 3000 tandem mass spectrometers interfaced with a heated nebulizer probe and operated in the positive ionization mode. Both tube and plate LLE methods achieved a lower limit of quantitation (LLOQ) of 0.5 ng/mL when 1.0 and 0.4 mL of human serum was processed, respectively, and were validated in the concentration range of 0.5-25 ng/mL; while for the in-tip SPME method, LLOQ was 5 ng/mL with only 0.1 mL of human serum required. Comparisons were made among three different methods, including precision and accuracy, sample throughput, recovery and matrix effects.  相似文献   

10.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method for the determination of drug enantiomers in serum was developed. The method involves direct injection of serum samples on to an ovomucoid-bonded column, which is prepared by bonding of ovomucoid proteins to an aminopropyl-silica gel by the N,N′-disuccinimidyl carbonate activation method and separation of drug enantiomers on the column using a mixture of phosphate buffer and an organic solvent. High recoveries of serum proteins were obtained using eluent pH values of 3, 4, 6 and 7 at phosphate buffer concentrations above 50 mM, whereas the recovery was ca. 70% at an eluent pH of 5. The recovery of each enantiomer of basic and acidic drugs from serum was almost 100%.  相似文献   

12.
A simple HPLC method has been developed that allows the sensitive determination of rifabutin (RBT) in human serum using on-line concentration and column switching. After pretreatment of the serum with acetonitrile and centrifugation, the samples were applied to a concentration column (CC) (Zorbax CN). Washing with phosphate buffer-methanol removed most of the contaminating substances. Via a six-port valve the CC was switched to the analytical mode. RBT was separated on a Chromspher RP 8 column (acetonitrile-phosphate buffer pH 7.4/sodium chloride) and determined photometrically at 278 nm. The lower limit of quantification for 200 μl serum precipitated with 200 μl acetonitrile and after injection of 2×150 μl was 33 μg/l and linearity was observed up to 27 mg/l. Different modes of sample application (single, repeated, and different injection volume portions), as well as washing time, cycle time and different CC materials were investigated.  相似文献   

13.
A simple and sensitive HPLC method for the determination of gatifloxacin concentrations in human serum and urine was developed and validated. Serum proteins were removed by ultrafiltration through a filtering device after adding a displacing agent. Urine samples were diluted with mobile phase prior to injection. Separation was achieved with a C18 reverse-phase column and gatifloxacin concentrations were determined using ultraviolet detection. The quantitation limits of the assay were 100 ng/ml in serum and 1.0 microg/ml in urine. The assay method was successfully applied to a pharmacokinetic study of gatifloxacin in healthy volunteers.  相似文献   

14.
In High Performance Liquid Chromatographic (HPLC) determination of chemicals with acidic functions, different labeling agents are used to improve sensitivity of the assay. 9-Fluorenylmethyl chloroformate (FMOC-Cl), on the other hand, is a suitable labeling agent, which reacts with both primary and secondary amines and less readily with hydroxyl groups in alkaline conditions. However, the reagent has not been applied in labeling of chemicals with acidic function yet. In this study which is the first report on application of FMOC-Cl in derivatization and analysis of a drug with acidic function, valproic acid (VPA), one of a series of fatty carboxylic acids with anticonvulsant activity, was derivatized using the reagent and quantified in serum samples by HPLC with fluorescence detection. In addition, to document the reaction between the labeling agent and carboxylic acid moiety of the drug, we developed a liquid chromatography-tandem MS/MS (LC-MS/MS) method. Following liquid-liquid extraction, derivatization of the drug and an internal standard was achieved in alkaline medium. The elute was monitored by a fluorescence detector with respective excitation and emission wavelengths of 265 and 315 nm. The present method is more sensitive comparing with other published HPLC procedures for analysis of VPA. The assay is sensitive enough to measure drug levels obtained in human single dose studies with a limit of quantification of 0.01 μg/mL. Also the method is linear over the concentrations range of 0.01-32 μg/mL of VPA in human serum using 100 μL serum sample and 5 μL injection. The coefficient variation values of both inter and intra day analysis were less than 12% and the percentage error was less than 4%. The method performance was studied and the validated procedure applied in a randomized cross-over bioequivalence study of two different VPA preparations in 24 healthy volunteers.  相似文献   

15.
A new simple, accurate and sensitive sequential injection analysis chemiluminescence (CL) detection method for the determination of cefditoren pivoxil (CTP) has been developed. The developed method was based on the enhancement effect of silver nanoparticles on the CL signal arising from a luminol–potassium ferricyanide reaction in the presence of CTP. The optimum conditions relevant to the effect of luminol, potassium ferricyanide and silver nanoparticle concentrations were investigated. The proposed method showed linear relationships between relative CL intensity and the investigated drug concentration at the range 0.001–5000 ng/mL, (r = 0.9998, n = 12) with a detection limit of 0.5 pg/mL and quantification limit of 0.001 ng/mL. The relative standard deviation was 1.6%. The proposed method was employed for the determination of CTP in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. In addition, the interference of some related cephalosporins was tested. No interference was recorded. The obtained sequential injection analysis‐CL results were statistically compared with those from a reported method and did not show any significant differences. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Siyu Chen  Fang Zhao 《Luminescence》2012,27(4):279-284
A simple, rapid and precise flow‐injection–chemiluminescence (FI–CL) method is presented for the determination of tenoxicam in pharmaceutical preparations and biological samples. The method is based on the weak chemiluminescence signal arising from the reaction of cerium(IV) in a nitric acid medium with sodium hyposulphite being significantly increased by tenoxicam in the presence of sodium dodecyl benzene sulphonate. Several experimental parameters affecting the CL reaction were examined and optimized systematically. Under the optimum conditions, the CL intensity was proportional to the concentration of tenoxicam in the range 7.0 × 10–11–5.0 × 10–8 g/mL. The detection limit was 2.3 × 10–11 g/mL tenoxicam and the relative standard deviation (RSD) was 2.1% for 1.0 × 10–9 g/mL tenoxicam solution (n = 11). The proposed method was applied to the determination of tenoxicam in pharmaceutical preparations, serum and human urine, with satisfactory results. The possible mechanism of the chemiluminescence reaction is also briefly discussed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
SEC-HPLC法测定重组人生长激素注射液中苯酚含量   总被引:1,自引:0,他引:1  
采用SEC-HPLC法测定重组人生长激素注射液中苯酚的含量。色谱柱为TSK G2000SWxL(7.8×300mm,5μ),流动相为PB(pH值7.0)-异丙醇(97∶3),流速0.6 mL/min,检测波长214nm,柱温25℃。苯酚在0.10~1.00 mg/mL浓度范围内线性关系良好,r=0.99915;最低检测限为0.5 ng/mL;平均回收率101.48%,RSD=0.58%(n=9);3批重组人生长激素注射液中苯酚的含量分别为2.98、3.02和2.96 mg/mL,分别为标示量的99.33%、100.67%和98.67%。SEC-HPLC法环保、准确、快速、可靠,可用于重组人生长激素注射液中苯酚含量的测定。  相似文献   

18.
A method for the quantitative determination of perhexiline and its main hydroxylated metabolites in human plasma, based on liquid chromatography-mass spectrometry (LC-MS), was developed. The method used protein precipitation with acetonitrile followed by dilution with water and subsequent direct injection of the extract into the LC-MS system. Hexadiline was used as internal standard and the intra-assay coefficients of variation were 相似文献   

19.
A simple and reproducible high-performance liquid chromatography (HPLC) method was developed for determination of cyclosporine (CyA, also known as cyclosporin A) in human whole blood. The method entailed direct injection of the blood samples after deproteination using acetonitrile. Chromatography was carried out using an ODS column under isocratic elution with acetonitrile-5mM disodium hydrogen phosphate (75:25, v/v), pH 5.1 at 70 degrees C and a detector set at 210 nm. The mean absolute recovery of cyclosporine from blood was 97%, and the linearity was assessed in the range of 100-3000 ng/ml blood, with a correlation coefficient of greater than 0.999. The limit of quantification and detection of the present method were 100 and 50 ng/ml, respectively. This method has been used to analyze several hundred human blood samples for bioavailability studies.  相似文献   

20.
A gradient elution reversed-phase high-performance liquid chromatographic method was developed for the direct serum injection analysis of porphyrins based on the use of eluent containing an anionic surfactant (sodium dodecyl sulfate) at a concentration below the critical micelle concentration to elute the serum proteins at the column void volume. Separation and detection performances were tested with a mixture of porphyrin standards containing uro-, heptacarboxylic-, hexacarboxylic-, pentacarboxylic-, copro-, zinc proto- and mesoporphyrin in a model serum consisting of 50 mg/ml bovine serum albumin. Average limit of detection is 0.06 pmol with a 10-μl injection volume using fluorimetric excitation at the Soret band of porphyrins. The utility of this method for the direct serum injection analysis of porphyrins in human serum was evaluated by investigating serum samples from individuals suffering from iron-deficiency anemia and breast cancer.  相似文献   