首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
Some epidemiological studies indicate an association between extremely low frequency electromagnetic field (ELF-EMF) exposure and cancer risks. These studies have mainly taken residential and occupational exposure into consideration. Outdoor environments are often considered as low level areas, but in this paper we show that this is not true in a city environment. We have mapped the ELF magnetic flux densities along certain stretches of sidewalk in central G?teborg City, Sweden. About 50% of the investigated street length shows flux densities of the same order of magnitude (0.2 microT and above) as those associated with increased risks of cancer in epidemiological studies. We conclude that the outdoor exposures in a city environment also should be considered in exposure assessments and risk evaluations. These elevated flux densities are probably due to stray currents. We also found strong magnetic flux densities (> 1.0 microT) close to ordinary distribution pillars, power substations, shoplifting alarms, and other electrical devices.  相似文献   

2.
This study investigates the individual magnetic field exposures at 16 2/3 and 50 Hz of 1952 people, selected from the Bavarian population. Personal flux density meters ("Field Watcher FW2A") were worn by the participants for 24 h. Every second, the flux density was recorded for both frequencies and for the three spatial axes (dynamic range per axis: several nT up to 100 microT at 50 Hz, 150 microT at 16 2/3 Hz). For 50 Hz fields, the mean of the 1,952 individual means was 0.101 microT and that of the individual medians was 0.047 microT. High level exposures occurred mainly during working hours. Only 2.4% of the subjects showed individual medians higher than 0.2 microT. About 53% of all volunteers were working on the day of recording. Levels for craftsmen (n = 148; mean individual mean: 0.166 microT) were generally higher than those for office workers (n = 624; mean individual mean: 0.107 microT). Flux densities exceeding 100 microT at 50 Hz were measured in 31 persons. The total time with such extreme exposures amounts to nearly 21 min, less than 0.001% of the total time for all measurements (5.3 years). To our knowledge, this is the first exposure study where 16 2/3 Hz magnetic fields (caused by electrified railways) have additionally been monitored over 24 h. For persons living next to railway lines, the mean individual mean (0.156 microT) and mean individual median (0.102 microT) were calculated. Over all, the mean exposures are only 0.1% of the magnetic flux density limit for 50 Hz (100 microT) and about 0.05% of the limit (300 microT) for 16 2/3 Hz recommended by the International Commission on Non-Ionizing Radiation Protection.  相似文献   

3.
We present the results of a study of the extremely low frequency (ELF) magnetic fields in urban environments of the Extremadura region (Spain). The study included a spectral analysis, an analysis of the temporal variation, and spot measurements in the streets of four cities. The spectral analysis showed that the main source of magnetic field exposure was that corresponding to the principal power frequency (50 Hz) and its third harmonic. The magnetic flux density measured at one point over 24 h presented rapid fluctuations in short time periods. Smoothing the time series eliminated these fluctuations, showing a temporal evolution associated with the differing levels of power consumption over the course of the day. The values of the spot measurements taken in the streets were all below the ICNIRP reference level, although 30% surpassed 0.2 microT, the value that some epidemiological studies take as the threshold above which there exist risks of effects that could be harmful to health. The values found for the magnetic flux density in these urban settings were generally greater than values reported in the literature for residential areas, and similar to, although in some cases less than those in workplace environments.  相似文献   

4.
Transformer stations in apartment buildings may offer a possibility to conduct epidemiological studies that involve high exposure to extremely low frequency magnetic fields (MF), avoid selection bias and minimize confounding factors. To validate exposure assessment based on transformer stations, measurements were performed in thirty buildings in three Finnish cities. In each building, spot measurements in all rooms and a 24-h recording in a bedroom were performed in one apartment above a transformer station (AAT), in one first floor (FF) reference apartment, and one reference apartment on upper floors (UF). The apartment mean of spot measurements was 0.62 microT in the AATs, 0.21 microT in the FF and 0.11 microT in the UF reference apartments The 24-h apartment mean (estimated from the spot measurements and the bedroom 24-h recording) was 0.2 microT or higher in 29 (97%) AATs, in 7 (25%) FF and in 3 (10 %) UF reference apartments. The corresponding numbers for the 0.4 microT cut-off point were 19 (63%), 4 (14%), and 1 (3.3%). The higher MF level in the FF reference apartments indicates that they should not be considered "unexposed" in epidemiological studies. If such apartments are excluded, a transformer station under the floor predicts 24-h apartment mean MF with a sensitivity of 0.41 (or 0.58) and a specificity of 0.997 (or 0.97), depending on the MF cut-off point (0.2 or 0.4 microT). The results indicate that apartments can be reliably classified as high and low MF field categories based on the known location of transformer stations.  相似文献   

5.
We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 microT rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m rms and the induced electric field was 1.9 V/m rms. The temperature was maintained at 36.5 +/- 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 microT rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 microT rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.  相似文献   

6.
The aim of the work was verification of the hypothesis that weak power frequency (50 Hz) magnetic fields (MF) affected the number of free oxygen radicals in living biological cells and that these changes could be qualitatively explained by the radical pair mechanism. The experiments were performed on rat lymphocytes. One-hour exposure to 50 Hz MF at 20, 40, or 200 microT flux densities was performed inside a pair of Helmholtz coils with axis along or crosswise to the Earth's static MF. Iron ions (FeCl2) were used as a stimulator of the oxidation processes. Oxygen radicals were measured by fluorimetry using a DCF-DA fluorescent probe. Only in the lymphocytes exposed at 40 microT MF directed along the Earth's static MF there was a decrease of fluorescence in relation to non-exposed samples. Our observation seems to confirm the hypothesis that low level power frequency MF affects oxidative processes which occur in living biological cells and that this effect can be explained by the radical pair mechanism.  相似文献   

7.
This study was undertaken to investigate whether power frequency magnetic fields can affect the kinetics of cell cycle progression in exposed human cells. To achieve this, cultures of normal human fibroblasts were synchronised in the G(0) phase of the cell cycle and exposed to 50 Hz magnetic fields at a range of flux densities. Progression through the cycle was monitored by examining the timing of entry into S phase, as characterised by the onset of DNA synthesis. Simultaneous positive controls were exposed to human recombinant fibroblast growth factor to demonstrate that the system was responsive to external stimuli. Exposure to magnetic fields at 20 and 200 microT induced a small but significant increase in the length of the G(1) phase of the cell cycle. However, exposure at higher flux densities of 2 and 20 mT had no significant effect. These results are discussed in relation to weak magnetic field effects on free radical concentration.  相似文献   

8.
Seeds of hornwort (Cryptotaenia japonica Hassk) were exposed to sinusoidally time-varying extremely low frequency (ELF) magnetic fields (AC fields) in combination with the local geomagnetic field (DC field). Exposure lasted 24 h/day for 16 days. Three directions of the AC magnetic fields were considered; the vertical (magnetic flux density B ACV, the directions parallel B ACparallel), and perpendicular B ACperpendicular to the direction of total geomagnetic field (magnetic flux density BG) in the geomagnetic plane (GP). Controls consisted of seeds exposed to zero AC magnetic fields in combination with the DC magnetic field. The B ACV in combination with BG effectively promoted the germination of hornwort seeds when applied at 750 microT (RMS) at 7 Hz or 500 microT (RMS) at 14 Hz from among the cases of individual frequencies f = 3.5, 7.0, 10.5, 14.0 Hz at 500 and 750 microT. The B ACparallel promoted the germination of hornwort seeds more effectively than the B ACperpendicular in combination with BG when 500 and 750 microT at 7 Hz were applied.  相似文献   

9.
In this paper, the magnetic flux density (MFD) distribution in a neonatal intensive care unit is described and MFD values inside a few open infant warming systems and incubators are reported. Typical measured values of the magnetic flux density at power frequency (50 Hz) in the "general environment" (the rooms of the unit) were lower than 0.2 microT, while higher MFD values were detected close to medical equipment and inside the open infant warming systems. In both cases, the magnetic flux density quickly decreases with increasing distance, so that measured values are reduced to "background" (i.e., general environment) levels 20-30 cm away from the sources. The total harmonic content over the 100-800 Hz frequency range was also evaluated. In the general environment, measured values in this band were negligible, while this was not the case close to medical equipment. Field levels inside the open and closed incubators depend on the position of the electronic control system, of the heating power generator and its winding conductor, and of the 220 V main plug. The magnetic flux density was also monitored for a prolonged period of time in a few types of open infant warming systems and incubators under standard intensive care unit operation with premature newborn present.  相似文献   

10.
A number of studies have shown that power frequency magnetic fields may affect spatial memory functions in rodents. An experiment was performed using a spontaneous object recognition task to investigate if nonspatial working memory was similarly affected. Memory changes in adult, male C57BL/6J mice were assessed by measuring the relative time within which the animals explored familiar or novel stimulus objects. Between initial testing and retesting, the animals were exposed for 45 min to a 50 Hz magnetic field at either 7.5 microT, 75 microT or 0.75 mT. Other animals were sham-exposed with ambient fields of less than 50 nT. No significant field-dependent effects on the performance of the task were observed at any flux density (for all measures, P > 0.05). These data provide no evidence to suggest that nonspatial working memory was affected in mice by acute exposure to an intense 50 Hz magnetic field.  相似文献   

11.
The possibility that weak, ac and dc magnetic fields in combination may affect binding equilibria of calcium-ions (Ca2+) was investigated with two metallochromic dyes as calcium-binding molecules: murexide and arsenazo III. Calcium-dye equilibria were followed by measuring solution absorbances with a fiber-optic spectrophotometer. A Ca(2+)-arsenazo solution was also used indirectly to monitor the binding of Ca2+ to calmodulin. Parallel, ac and dc magnetic fields were applied to each preparation. The ac magnetic field was held constant during each of a series of experiments at a frequency in the range between 50 and 120 Hz (sine wave) or at 50 pps (square wave) and at an rms flux density in the range between 65 and 156 microT. The dc magnetic field was then varied from 0 to 299 microT at 1.3 microT increments. The magnetic fields did not measurably affect equilibria in the binding of metallochromic dyes or calmodulin to Ca2+.  相似文献   

12.
Recent epidemiological studies suggest a link between transport magnetic fields (MF) and certain adverse health effects. We performed measurements in workplaces of engineers on Russian DC and Swiss AC powered (16.67 Hz) electric trains using a computer based waveform capture system with a 200 Hz sampling rate. MF in DC and AC trains show complex combinations of static and varying components. The most probable levels of quasistatic MF (0.001-0.03 Hz) were in the range 40 microT. Maximum levels of 120 microT were found in DC powered locomotives. These levels are much higher than the geomagnetic field at the site of measurements. MF encountered both in DC and AC powered rail systems showed irregular temporal variability in frequency composition and amplitude characteristics across the whole frequency range studied (0-50 Hz); however, more than 90% of the magnetic field power was concentrated in frequencies 相似文献   

13.
Belova NA  Lednev VV 《Biofizika》2001,46(1):118-121
It was found that the rate of gravitropic bending in apical segments excised from 4-day-old etiolated seedlings of flax Linum bienne is strongly and nonlinearly dependent on the value of the magnetic flux density of a static magnetic field, BDC, in the range from 0 to 350 microT. The gravitropic bending is stimulated at 0 < or = BDC < or = 2 microT and 200 < or = BDC < or = 350 microT but is inhibited at 100 < or = BDC < or = 170 microT relative to control samples being in the magnetic field of the Earth equal to 46.5 microT.  相似文献   

14.
A small, lightweight meter has been developed for magnetic-field measurements, particularly those needed for exposure-assessment purposes. This meter, known as the AMEX-3D, continuously measures all three axes of magnetic-flux density and electronically combines the data into a single estimate of cumulative exposure to the root-mean-square (rms) resultant flux density. The AMEX-3D weighs about 120 g, measures 2.7 cm x 5.1 cm x 10.2 cm, and is battery powered. Two panel-mounted jacks are provided for measuring battery voltage and for reading cumulative exposure data from the unit. The instrument has, within 3 dB, a flat response to magnetic flux densities at all frequencies in its 30-1,000 Hz bandwidth. A detailed analysis of error sources in the AMEX-3D leads to an estimate of +/- 20% as the accuracy of the instrument over its dynamic range, which extends from 0.02 to 15 microT. The AMEX-3D was tested in the field by asking electric-utility distribution linemen to wear AMEX-3D and EMDEX meters simultaneously while working. Agreement between the two measures of exposure was excellent.  相似文献   

15.
A current peak has been observed and measured in ionic electrolytic current of a glutamic acid aqueous solution, placed in a static magnetic field of flux density of 40 microT, with a superimposed low-frequency alternating magnetic field of flux density of 40 nT. The peak occurs at the frequency of the cyclotronic resonance of the molecular mass of a single charged glutamic acid ion, placed in a magnetic flux density equal to that of the static field. The amplitude of the current peak is about 30% of the background electrolytic current. Qualitative considerations and a listing of unsolved problems related to the phenomenology are given. The result is the first contribution to the study we have undertaken on the effects of low-frequency alternating electromagnetic fields on the ionic current of amino acid aqueous solutions which are the basic structural units of the proteins.  相似文献   

16.
This study compares stationary home measurements with a personal exposure monitor of 60 Hz magnetic fields in a group of 18 people living near a 735 kV line and 17 people living far away from the line. Most of them were white collar workers who worked during the day. They wore a personal Positron meter for 24 h, while a similar meter was left in their home, away from any appliances. For people living away from the line, the impact of residential activities appeared rather weak when considering the average intensity of the field during the awake period (at home): 0.22 microT for personal exposure versus 0.18 microT for stationary measurements (P = 0.09). The impact of residential activities during the awake period was more detectable when using the percentage of time with exposure above 0.78 microT: median 0.4 for personal vs. 0.0 for stationary measurements (P =.01). The temporal variability of the exposure during the awake period was also significantly higher for personal exposure than for stationary measurements. For people living near the line, the intensity of the magnetic field from the line dominated the personal exposure when considering the mean of measurements and the percentage of time above a threshold. However, the temporal variability was greater for the personal exposure during the awake period. Although limited due to its small sample size, the present study seems to demonstrate the usefulness of considering different indexes of exposure when assessing residential exposure to 60 Hz magnetic fields.  相似文献   

17.
Response by coypus to catastrophic events of cold and flooding   总被引:2,自引:0,他引:2  
Population dynamics of the coypu, Myocastor coypus , were studied in central-West France. This species has recently colonized temperate regions despite physiological sensitivity to cold weather. Live-trapping over three years demonstrated that increasing population densities from summer into autumn were associated with a faster population turn-over, homogeneous dispersion, and reduced rates of weight gain. Densities fell by 71% over a cold winter in which canals froze for 20 consecutive days, and by 69% over a mild winter with a flood of 5 weeks duration. Mortality was high in the coldest weather, and 45% of those surviving had frost lesions. A scarcity of males after the cold winter (up to 1♂: 3.3♀) was matched in a nearby population at artificially low density, where dispersing males predominated after the flood. The effect of the cold winter on reproductive output was to synchronize littering in summer, at a time of rich food supply. It was concluded that a flexible response to winter conditions enabled coypus to minimize the effects of extreme events and maximize their colonizing potential.  相似文献   

18.
Passerines that overwinter in temperate climates undergo seasonal acclimatization that is characterized by metabolic adjustments that may include increased basal metabolic rate (BMR) and cold-induced summit metabolism (M(sum)) in winter relative to summer. Metabolic changes must be supported by equivalent changes in oxygen transport. While much is known about the morphology of the avian respiratory system, little is known about respiratory function under extreme cold stress. We examined seasonal variation in BMR, M(sum), and ventilation in seasonally acclimatized house sparrows from Wisconsin. BMR and M(sum) increased significantly in winter compared with summer. In winter, BMR increased 64%, and M(sum) increased 29% over summer values. The 64% increase in winter BMR is the highest recorded for birds. Metabolic expansibility (M(sum)/BMR) was 9.0 in summer and 6.9 in winter birds. The metabolic expansibility of 9.0 in summer is the highest yet recorded for birds. Ventilatory accommodation under helox cold stress was due to changes in breathing frequency (f), tidal volume, and oxygen extraction efficiency in both seasons. However, the only significant difference between summer and winter ventilation measures in helox cold stress was f. Mean f in helox cold stress for winter birds was 1.23 times summer values.  相似文献   

19.
V B Kuznetsov 《Biofizika》1999,44(3):496-502
Vegetative responses of dolphin to changes in permanent magnetic field were studied. Electrocardiograms, cutaneogalvanic reactions, and respiration were registered. These parameters were compared with the functional behavior of dolphin: motion, sharp frequent expirations, and acoustic activity. Functional responses to permanent magnetic fields of 32; 108 and 168 microT were registered in 79.2, 63.3 and 52.9% of presentations, respectively. The frequency of responses in control at a power of geomagnetic field of 48.5 microT was 32.7%. Five latent periods were observed in the response of dolphin to changes in magnetic field (72% of responses). It is shown that dolphins have a high responsiveness to changes in permanent magnetic field "magnetic sense").  相似文献   

20.
Several epidemiologic studies have suggested an association between exposure to extremely low frequency (ELF) magnetic fields (MFs) and cancer in adults and children. A possible target of MFs is the immune system. The effects of the exposure to ELF MFs on the immunological functions of human peripheral blood mononuclear cells (PBMCs) obtained from healthy male volunteers were assessed by measuring the natural killer (NK) and lymphokine activated killer (LAK) activities and the production of interferon-gamma (IFN-gamma), tumor necrosis factor-alpha (TNF-alpha), interleukin-2 (IL-2), and interleukin-10 (IL-10). The PBMCs were exposed to three different MF: linearly polarized (vertical), circularly polarized, and elliptically polarized, at 50 and 60 Hz. Magnetic flux densities were set at 500, 100, 20, and 2 microT (rms) for vertical field and at 500 microT (rms) for the rotating fields. Using cytotoxicity assay and enzyme-linked immunosorbent assay (ELISA) for cytokine production, we could not find any effects of ELF MFs on the cytotoxic activities and the cytokines production of human PBMCs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号