首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
High background fluorescence and unspecific staining hampered the epifluorescence enumeration of bacteria in 45% of the tested soil and sediment samples with 4′,6-diamidino-2-phenylindole (DAPI) and polycarbonate membrane filters. These problems of the determination of total cell counts can be circumvented by using green fluorescent high-affinity nucleic acid dyes and aluminum oxide membrane filters. Due to the bright staining of cells, we recommend SYBR Green II as dye.  相似文献   

2.
Use of the MIDI-FAME technique to characterize groundwater communities   总被引:3,自引:0,他引:3  
Fatty acid methyl ester (FAME) profiles were identified directly from groundwater microbial communities concentrated on and extracted with polycarbonate filters. The sensitivity of this direct extraction method was determined using pure cultures of Acinetobacter junii, Pseudomonas putida and Stenotrophomonas maltophilia. A minimum concentration of 107 cells filter-1 was required to identify the predominant fatty acids from each culture. However, at least 3.7 x 109 cells filter-1 were required to obtain fatty acid profiles that matched the signature profiles for pure cultures in a commercial database. While several saturated fatty acids (i.e. 14 : 0, 16 : 0, 18 : 0) were extracted from the polycarbonate filters, they were readily subtracted from microbial fatty acid profiles and did not interfere with the characterization of pure cultures or environmental samples. For the environmental samples, 3 l of groundwater from the Savannah River Site, Aiken, SC, (USA) contained sufficient biomass for direct extraction. A comparative analysis of FAME groundwater profiles demonstrated a qualitative difference among communities sampled from spatially discrete locations, while a groundwater well that was sampled at two time points showed strong similarities over time. Concentration of microbial biomass on polycarbonate filters coupled with the MIDI-FAME extraction of both biomass and filter was a useful technique to characterize microbial communities from groundwater.  相似文献   

3.
The redox dye 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) was employed for direct epifluorescent microscopic enumeration of respiring bacteria in environmental samples. Oxidized CTC is nearly colorless and is nonfluorescent; however, the compound is readily reduced via electron transport activity to fluorescent, insoluble CTC-formazan, which accumulates intracellularly. Bacteria containing CTC-formazan were visualized by epifluorescence microscopy in wet-mount preparations, on polycarbonate membrane filter surfaces, or in biofilms associated with optically opaque surfaces. Counterstaining of CTC-treated samples with the DNA-specific fluorochrome 4',6-diamidino-2-phenylindole allowed enumeration of active and total bacterial subpopulations within the same preparation. Municipal wastewater, groundwater, and seawater samples supplied with exogenous nutrients yielded CTC counts that were generally lower than total 4',6-diamidino-2-phenylindole counts but typically equal to or greater than standard heterotrophic (aerobic) plate counts. In unsupplemented water samples, CTC counts were typically lower than those obtained with the heterotrophic plate count method. Reduction of CTC by planktonic or biofilm-associated bacteria was suppressed by formaldehyde, presumably because of inhibition of electron transport activity and other metabolic processes. Because of their bright red fluorescence (emission maximum, 602 nm), actively respiring bacteria were readily distinguishable from abiotic particles and other background substances, which typically fluoresced at shorter wavelengths. The use of CTC greatly facilitated microscopic detection and enumeration of metabolically active (i.e., respiring) bacteria in environmental samples.  相似文献   

4.
With the direct epifluorescent filter technique (DEFT), differentiation of bacteria was achieved by a modified Gram-staining procedure using acridine orange as the counterstain. The method enumerated viable Gram-negative and all Gram-positive bacteria. Counts of clumps of orange fluorescent cells (Gram-negative DEFT count) correlated well with colony counts of Gram-negative bacteria in samples of raw milk ( r = 0·94). The use of stainless steel membrane filter supports and the addition of citrate-NaOH buffer (0·1 M, pH 3·0) during filtration enabled 10 ml samples of milk to be filtered, thereby increasing the sensitivity of the DEFT five-fold. The relationship between colony and DEFT counts with 10 ml samples was better ( r = 0·90) than that using standard 2 ml samples ( r = 0·88). Alternatively, these modifications in procedure allowed the preincubation time for 2 ml milk samples to be reduced from 10 to 2 min. Sonication was successful in dispersing bacterial clumps in both pure cultures and in raw milk samples to yield a bacterial count by DEFT which should give a better indication of the hygienic status and keeping quality of a product, than counts of colony forming units.  相似文献   

5.
An oligodeoxynucleotide probe (GSB-532) specific for green sulfur bacteria was developed. Highly stringent hybridization conditions were established using whole cells of Chlorobium limicola DSM249 immobilized on glass slides. At a formamide concentration of 10%, the optimum specificity was reached at 47 °C. When a conventional fixation procedure was used, a conspicuous autofluorescence developed within the cells. This autofluorescence was due to the liberation of bacteriochlorophyll by the detergent Triton X-100 and a subsequent conversion to bacteriopheophytin and related compounds. The signal-to-noise ratio could be increased by a final dehydration of the samples with methanol. Finally, the method was adapted to the hybridization of natural samples collected on polycarbonate membrane filters. In situ hybridization of pure cultures, various enrichments, and natural samples from the chemocline of a freshwater lake confirmed that probe GSB-532 hybridized exclusively to cells of green sulfur bacteria. Our protocol allows the highly specific detection of green sulfur bacteria in water samples and a rapid screening of natural bacterial communities. Employing probe GSB-532, the phylogenetic affiliation of the epibionts in “Chlorochromatium aggregatum” and “Pelochromatium roseum” could be demonstrated for the first time. Received: 26 October 1998 / Accepted: 7 January 1999  相似文献   

6.
The redox dye 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) was employed for direct epifluorescent microscopic enumeration of respiring bacteria in environmental samples. Oxidized CTC is nearly colorless and is nonfluorescent; however, the compound is readily reduced via electron transport activity to fluorescent, insoluble CTC-formazan, which accumulates intracellularly. Bacteria containing CTC-formazan were visualized by epifluorescence microscopy in wet-mount preparations, on polycarbonate membrane filter surfaces, or in biofilms associated with optically opaque surfaces. Counterstaining of CTC-treated samples with the DNA-specific fluorochrome 4',6-diamidino-2-phenylindole allowed enumeration of active and total bacterial subpopulations within the same preparation. Municipal wastewater, groundwater, and seawater samples supplied with exogenous nutrients yielded CTC counts that were generally lower than total 4',6-diamidino-2-phenylindole counts but typically equal to or greater than standard heterotrophic (aerobic) plate counts. In unsupplemented water samples, CTC counts were typically lower than those obtained with the heterotrophic plate count method. Reduction of CTC by planktonic or biofilm-associated bacteria was suppressed by formaldehyde, presumably because of inhibition of electron transport activity and other metabolic processes. Because of their bright red fluorescence (emission maximum, 602 nm), actively respiring bacteria were readily distinguishable from abiotic particles and other background substances, which typically fluoresced at shorter wavelengths. The use of CTC greatly facilitated microscopic detection and enumeration of metabolically active (i.e., respiring) bacteria in environmental samples.  相似文献   

7.
Flow cytometry and Fluorescence In Situ Hybridization are common methods of identifying and quantifying bacterial cells. The combination of cytometric rapidity and multi-parametric accuracy with the phylogenetic specificity of oligonucleotide FISH probes has been regarded as a powerful and emerging tool in aquatic microbiology. In the present work, tests were carried out on E. coli pure culture and marine bacteria using an in-solution hybridization protocol revealing high efficiency hybridization signal for the first one and a lower for the second one. Other experiments were conducted on natural samples following the established CARD-FISH protocol on filter performed in a closed system, with the aim of improving cell detachment and detection. The hybridized cells were then subsequently re-suspended from the membrane filters by means of an optimized detachment procedure. The cytometric enumeration of hybridized marine bacteria reached 85.7% ± 18.1% of total events. The quality of the cytograms suggests that the procedures described may be applicable to the cytometric quantification of phylogenetic groups within natural microbial communities.  相似文献   

8.
Understanding the role of bacteria in microbial food webs is intimately connected to the methods applied in the direct enumeration of bacteria. We have examined over 220 papers describing studies in which fluorochrome staining followed by epifluorescent microscopic direct counts was used to estimate total bacterial abundances. In this review, we summarize patterns in the use of 3,6-bis[dimethylamino]acridinium chloride (acridine orange) and 4',6-diamidino-2-phenylindole (DAPI), the two stains most frequently used in bacterial enumeration. The staining of samples with these fluorochromes, followed by filtration and direct counting of bacterial cells on filter surfaces, has become routine over the past 10 years. We examine trends in features of the standard direct count methods, such as sample preservation and preparation techniques, membrane filter types used, applied stain concentrations, duration of staining, and counting strategies, in relation to the types of samples being examined. The high variability in bacterial counts observed within similar sample types may be partially accounted for by differences in methods. Synthesizing review findings, we include a recommended method for the direct enumeration of bacteria in environmental samples.  相似文献   

9.
Stability of microbial cultures during sampling and storage is a vital issue in various fields of medicine, biotechnology, food science, and forensics. We have developed a unique bacterial preservation process involving a non-toxic, water-soluble acacia gum polymer that eliminates the need for refrigerated storage of samples.The main goal of this study is to characterize the efficacy of acacia gum polymer for preservation of pathogenic bacteria (Bacillus anthracis and methicillin-resistant Staphylococcus aureus—MRSA) on different materials, used for swabbing and filtration: cotton, wool, polyester, rayon, charcoal cloth, and Whatman paper.Acacia gum polymer used for preservation of two pathogens has been shown to significantly protect bacteria during dehydration and storage in all tested samples at the range of temperatures (5-45 °C for MRSA and 40-90 °C for B. anthracis). Our results showed higher recovery as well as higher viability during the storage of both bacteria in all materials with acacia gum. Addition of acacia gum polymer to swabbing materials or filters will increase efficacy of sample collection and identification of pathogenic bacteria from locations such as hospitals or the environment. Proposed approach can also be used for long-term storage of culture collections, since acacia gum contributes to viability and stability of bacterial cultures.  相似文献   

10.
Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0 × 103 (3.48 log) counts mL− 1. We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with ≥ 3.48 or < 3.48 log total bacterial counts mL− 1 were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for Legionella control at bathing facilities, especially those where the effectiveness of chlorine is reduced by the presence of Fe2+, Mn2+, NH4+, skin debris, and/or biofilms in the water.  相似文献   

11.
Ethidium monoazide bromide (EMA) treatment of pure culture and environmental waters at low concentrations (1.0–7.5 μg/ml) indicated effective enumeration of viable and viable but nonculturable Escherichia coli in pure cultures, creek waters, and secondary activated sludge effluent samples by quantitative polymerase chain reaction (qPCR) amplification of the uidA and fliC gene targets at turbidity values <10 NTU. However, EMA treatment was not effective in primary clarifier and secondary trickling filter effluents where turbidities were ≥10 NTU. In viable pure cultures, rapidly dividing and senescent cells were most affected by increasing EMA concentrations. Amplification of heat-killed pure bacterial cultures decreased 4 to 6 logs depending on EMA concentration and culture age. The greatest difference was observed in 5-h cultures using 7.5 μg/ml EMA. Turbidity (≥100 NTU) in environmental samples inhibited EMA effectiveness on viability discrimination. Enumeration of E. coli in certain wastewaters using EMA-qPCR was similar to culture suggesting that EMA treatment could be incorporated into qPCR assays for the quantification of viable bacteria increasing assay time no more than 30 min. Our results indicate that EMA can be used in routine qPCR assays, but optimum conditions for exposure must be identified for each sample type due to sample matrix effects such as turbidity.  相似文献   

12.
The use of fluorescence in situ hybridization (FISH) to identify and enumerate soil bacteria has long been hampered by the autofluorescence of soil particles masking the bacterial signals and because the need of counting hundreds of bacteria in order to achieve statistically reliable data is time consuming. Recently, it was demonstrated that Nycodenz facilitates FISH in soil by concentrating bacteria on membrane filters and avoiding autofluorescent soil particles. We present a routine protocol for FISH in soil including the use of Nycodenz. The protocol allows fast and easy enumeration of hundreds of bacteria. We propose the use of silicon grease coated slides to treat in parallel seven samples per hybridization. Further, we developed a semi-automated approach for the enumeration of bacteria by implementing macros concatenating all steps of the image analyzes in the Image J software. Using Nycodenz, software-assisted bacterial counts statistically matched eye-counts of the same images and it was possible to count 880 DAPI stained bacteria per ten images. Fifty-five percent of these bacteria were co-labelled with the FISH probe specific for the Domain Bacteria, in accordance with recent FISH studies of bacterial populations in bulk soil. With a soil slurry protocol used for comparison, soil particles impaired automatic counts of the bacteria and FISH analysis, and only 88 DAPI stained bacteria per ten images could be counted by eye. With the Nycodenz protocol, 5 mM Na(2)EDTA used as an extractant increased the number of bacteria observed by 49%. In contrast, Tween 20 (1% or 5%) had no significant effect and increased the variability between the samples. Overall, the proposed procedure allows to process a high number of samples and to achieve a time efficient FISH characterization of soil bacterial communities.  相似文献   

13.
E L Lim  D A Caron    E F Delong 《Applied microbiology》1996,62(4):1416-1423
A fluorescent in situ hybridization method that uses rRNA-targeted oligonucleotide probes for counting protists in cultures and environmental water samples is described. Filtration, hybridization, and enumeration of fixed cells with biotinylated eukaryote-specific probes and fluorescein isothiocyanate-conjugated avidin were performed directly on 0.4-microns-pore-size polycarbonate filters of Transwell cell culture inserts (Costar Corp., Cambridge, Mass.). Counts of various species of cultured protists by this probe hybridization method were not significantly different from counts obtained by the 4',6-diamidino-2-phenylindole (DAPI) and acridine orange (AO) staining methods. However, counts of total nanoplankton (TNAN) based on probe hybridizations in several field samples and in samples collected from a mesocosm experiment were frequently higher than TNAN counts obtained by staining with DAPI or AO. On the basis of these results, 25 to 70% of the TNAN determined with probes were not detectable by DAPI or AO staining. The underestimation of TNAN abundances in samples stained with DAPI or AO was attributed to the existence of small nanoplanktonic cells which could be detected with probes but not DAPI or AO and the difficulty associated with distinguishing DAPI- or AO-stained protists attached to or embedded in aggregates. We conclude from samples examined in this study that enumeration of TNAN with oligonucleotide probes provides estimates of natural TNAN abundances that are at least as high as (and in some cases higher than) counts obtained with commonly employed fluorochrome stains. The quantitative in situ hybridization method we have described here enables the direct enumeration of free-living protists in water samples with oligonucleotide probes. When combined with species-specific probes, this method will enable quantitative studies of the abundance and distribution of specific protistan taxa.  相似文献   

14.
The growth patterns of macrocolonies of 59 different pure cultures were studied on eight selective solid media. A method of growing microcolonies on the surface of polycarbonate membrane filters, placed on the selective agar media, followed by staining and examination by epifluorescent microscopy was developed. The patterns of growth of the pure cultures as microcolonies were studied on the eight selective media. Only four media proved to be reliable for this purpose and the relationship between the microcolony count and plate count was studied on these media together with nutrient agar. Microcolony counts using three of these media (enriched lauryl sulphate aniline blue, pseudomonas selective agar (C-F-C) and Baird-Parker medium) were capable of giving reliable estimates of coliforms (r = 0·89), pseudomonads (r = 0·93) and staphylococci (r = 0·92) after incubation at 30°C for 3 or 6 h (staphylococci) at contamination levels of above 103 bacteria/g in a variety of foods. The results are available within a working day and should allow the more efficient management of food supplies.  相似文献   

15.
With the direct epifluorescent filter technique (DEFT), differentiation of bacteria was achieved by a modified Gram-staining procedure using acridine orange as the counterstain. The method enumerated viable Gram-negative and all Gram-positive bacteria. Counts of clumps of orange fluorescent cells (Gram-negative DEFT count) correlated well with colony counts of Gram-negative bacteria in samples of raw milk (r = 0.94). The use of stainless steel membrane filter supports and the addition of citrate-NaOH buffer (0.1 M, pH 3.0) during filtration enabled 10 ml samples of milk to be filtered, thereby increasing the sensitivity of the DEFT five-fold. The relationship between colony and DEFT counts with 10 ml samples was better (r = 0.90) than that using standard 2 ml samples (r = 0.88). Alternatively, these modifications in procedure allowed the preincubation time for 2 ml milk samples to be reduced from 10 to 2 min. Sonication was successful in dispersing bacterial clumps in both pure cultures and in raw milk samples to yield a bacterial count by DEFT which should give a better indication of the hygienic status and keeping quality of a product, than counts of colony forming units.  相似文献   

16.
AIMS: To use BioBall cultures as a precise reference standard to evaluate methods for enumeration of Escherichia coli and other coliform bacteria in water samples. METHODS AND RESULTS: Eight methods were evaluated including membrane filtration, standard plate count (pour and spread plate methods), defined substrate technology methods (Colilert and Colisure), the most probable number method and the Petrifilm disposable plate method. Escherichia coli and Enterobacter aerogenes BioBall cultures containing 30 organisms each were used. All tests were performed using 10 replicates. The mean recovery of both bacteria varied with the different methods employed. CONCLUSIONS: The best and most consistent results were obtained with Petrifilm and the pour plate method. Other methods either yielded a low recovery or showed significantly high variability between replicates. SIGNIFICANCE AND IMPACT OF THE STUDY: The BioBall is a very suitable quality control tool for evaluating the efficiency of methods for bacterial enumeration in water samples.  相似文献   

17.
18.
Tests of two leading brands of membrane filters used for enumerating fecal coliform bacteria showed that Gelman GN-6 filters recovered statistically more colonies of bacteria than did Millipore HAWG 047SO filters from pure cultures incubated at either 35 C (the optimal growth temperature) or 44.5 C (the standard temperature for the fecal coliform test). Standard membrane filter procedures with M-FC broth base were used to enumerate the organisms. Densities of colonies incubated on Gelman filters at 44.5 C averaged 2.3 times greater than those on Millipore filters. Plate counts of the bacteria at both temperatures indicated that incubation at 44.5 C did not inhibit propagation of fecal coliform bacteria. For the pour plates, M-FC broth base plus 1.5% agar was used. This modified medium compared favorably to plate count agar for enumerating Escherichia coli. At 35 and 44.5 C, colony counts on Gelman filters agreed closely with plate counts prepared concurrently, but Millipore counts were consistently lower than plate counts, especially at 44.5 C. Comparative analyses of river water for fecal coliform bacteria by the membrane filter technique gave results comparable to those for the pure cultures.  相似文献   

19.
Experiments were conducted to (i) compare most-probable-number (MPN) procedures with roll tube procedures for enumeration of forage anaerobic bacteria and (ii) evaluate the efficacy of using ethylene oxide to sterilize wet herbage. Alfalfa, corn, and alfalfa-orchardgrass silages and alfalfa and orchardgrass herbages were analyzed for total anaerobic bacteria (medium pH, 6.8) and acid-tolerant anaerobic bacteria (medium pH, 4.5) by both roll tube and MPN procedures. No difference was found between the roll tube and MPN procedures for total bacteria; however, higher counts were obtained for acid-tolerant bacteria when the MPN procedure was used. Although MPN procedures require less time to obtain an estimate of bacterial numbers, isolation and identification of the microbial population is not possible. Alfalfa herbage was treated with ethylene oxide for 12, 24, or 36 h, incubated for 7 days at 37°C with or without addition of a bacterial inoculant, and analyzed for total bacteria by MPN procedures. Microbial growth after inoculation of ethylene oxide-treated herbage indicated that there was insufficient residual ethylene oxide to inhibit subsequent microbial growth. The results also indicated that 24 h was required to adequately sterilize fresh herbage. Thus, ethylene oxide can be used to sterilize wet herbage for use as a substrate for pure cultures of silage bacteria.  相似文献   

20.
The aim of this study was to investigate the impact on numbers of using different media for the enumeration of Escherichia coli subjected to stress, and to evaluate the use of different resuscitation methods on bacterial numbers. E. coli was subjected to heat stress by exposure to 55 degrees C for 1h or to light-induced oxidative stress by exposure to artificial light for up to 8h in the presence of methylene blue. In both cases, the bacterial counts on selective media were below the limits of detection whereas on non-selective media colonies were still produced. After resuscitation in non-selective media, using a multi-well MPN resuscitation method or resuscitation on membrane filters, the bacterial counts on selective media matched those on non-selective media. Heat and light stress can affect the ability of E. coli to grow on selective media essential for the enumeration as indicator bacteria. A resuscitation method is essential for the recovery of these stressed bacteria in order to avoid underestimation of indicator bacteria numbers in water. There was no difference in resuscitation efficiency using the membrane filter and multi-well MPN methods. This study emphasises the need to use a resuscitation method if the numbers of indicator bacteria in water samples are not to be underestimated. False-negative results in the analysis of drinking water or natural bathing waters could have profound health effects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号