首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Rapid identification of microorganisms in urine is essential for patients with urinary tract infections (UTIs). Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been proposed as a method for the direct identification of urinary pathogens. Our purpose was to compare centrifugation-based MALDI-TOF MS and short-term culture combined with MALDI-TOF MS for the direct identification of pathogens in urine specimens. We collected 965 urine specimens from patients with suspected UTIs, 211/965 isolates were identified as positive by conventional urine culture. Compared with the conventional method, the results of centrifugation-based MALDI-TOF MS were consistent in 159/211 cases (75.4%), of which 135/159 (84.9%) had scores ≥ 2.00; 182/211 cases (86.3%) were detected using short-term culture combined with MALDI-TOF MS, of which 153/182 (84.1%) had scores ≥ 2.00. There were no apparent differences among the three methods (p = 0.135). MALDI-TOF MS appears to accelerate the microbial identification speed in urine and saves at least 24 to 48 hours compared with the routine urine culture. Centrifugation-based MALDI-TOF MS is characterized by faster identification speed; however, it is substantially affected by the number of bacterial colonies. In contrast, short-term culture combined with MALDI-TOF MS has a higher detection rate but a relatively slow identification speed. Combining these characteristics, the two methods may be effective and reliable alternatives to traditional urine culture.  相似文献   

2.
AIMS: Compactdry SCD, a new quantitative, ready-to-use and self-diffusible dry medium sheet urine culture system, was compared with conventional methods to evaluate the results of quantitative urine cultures. METHODS & RESULTS: Compactdry SCD was tested on 25 urine specimens, and results compared with those of traditional culture methods. The results from Compactdry SCD analysis correlated well with those from the standard plate count (SPC) method. In fact, the correlation was stronger than that dipslide systems and SPC. Even low-count bacteriuria (< 103 cfu ml(-1) and mixed bacteriuria were detected by Compactdry SCD. CONCLUSIONS: The Compactdry SCD system provides results comparable to those obtained by SPC: simple interpretation, ease of use, long-term storage and good sensitivity. SIGNIFICANCE AND IMPACT OF THE STUDY: This is the first report suggesting that the Compactdry SCD system has many advantages over traditional quantitative urine culture methods and that it is both appropriate and practical for clinical use.  相似文献   

3.
Urinary tract infections (UTIs) are one of the most common bacterial infections and are predominantly caused by uropathogenic Escherichia coli (UPEC). E. coli strains belonging to 14 serogroups, including O1, O2, O4, O6, O7, O8, O15, O16, O18, O21, O22, O25, O75 and O83, are the most frequently detected UPEC strains in a diverse range of clinical urine specimens. In the current study, the O-antigen gene clusters of E. coli serogroups O1, O2, O18 and O75 were characterized. A multiplex PCR method based on O-antigen-specific genes was developed for the simultaneous detection of all 14 E. coli serogroups. The multiplex PCR method was shown to be highly specific and reproducible when tested against 186 E. coli and Shigella O-serogroup reference strains, 47 E. coli clinical isolates and 10 strains of other bacterial species. The sensitivity of the multiplex PCR method was analyzed and shown to detect O-antigen-specific genes in samples containing 25 ng of genomic DNA or in mock urine specimens containing 40 colony-forming units (CFUs) per ml. Five urine specimens from hospital were examined using this multiplex PCR method, and the result for one sample was verified by the conventional serotyping methods. The multiplex PCR method developed herein can be used for the detection of relevant E. coli strains from clinical and/or environmental samples, and it is particularly useful for epidemiologic analysis of urine specimens from patients with UTIs.  相似文献   

4.
This study presents a novel approach to aid in diagnosis of urinary tract infections (UTIs). A real-time PCR assay was used to screen for culture-positive urinary specimens and to identify the causative uropathogen. Semi-quantitative breakpoints were used to screen for significant bacteriuria (presence of ≥105 CFU/ml of uropathogens) or low-level bacteriuria (containing between 103 and 104 CFU/ml of uropathogens). The 16S rDNA-based assay could identify the most prevalent uropathogens using probes for Escherichia coli, Pseudomonas species, Pseudomonas aeruginosa, Staphylococcus species, Staphylococcus aureus, Enterococcus species and Streptococcus species. 330 urinary specimens were analysed and results were compared with conventional urine culture. Using a PCR Ct value of 25 as semi-quantitative breakpoint for significant bacteriuria resulted in a sensitivity and specificity of 97% and 80%, respectively. In 78% of the samples with monomicrobial infections the assay contained probes to detect the bacteria present in the urine specimens and 99% of these uropathogens was correctly identified. Concluding, this proof-of-concept approach demonstrates that the assay can distinguish bacteriuria from no bacteriuria as well as detect the involved uropathogen within 4 hours after sampling, allowing adequate therapy decisions within the same day as well as drastically reduce consequent urine culturing.  相似文献   

5.
In this paper, a method for the sensitive and reproducible analysis of lignocaine and its four principal metabolites, monoethylxylidide (MEGX), glycylxylidide (GX), 3-hydroxylignocaine (3-HO-LIG), 4-hydroxylignocaine (4-HO-LIG) in equine urine and plasma samples is presented. The method uses liquid chromatography coupled to tandem mass spectrometry operating in electrospray ionisation positive ion mode (+ESI) via multiple reaction monitoring (MRM). Sample preparation involved solid-phase extraction using a mixed-mode phase. The internal standard adopted was lignocaine-d10. Lignocaine and its metabolites were successfully resolved using an octadecylsilica reversed-phase column using a gradient mobile phase of acetonitrile and 0.1% (v/v) aqueous formic acid at a flow rate of 300 μL/min. Target analytes and the internal standard were determined by using the following transitions; lignocaine, 235.2 > 86.1; 3-HO-LIG and 4-HO-LIG, 251.2 > 86.1; MEGX, 207.1 > 58.1; GX, 179.1 > 122.1; and lignocaine-d10, 245.2 > 96.1. Calibration curves were generated over the range 1–100 ng/mL for plasma samples and 1–1000 ng/mL for urine samples. The method was validated for instrument linearity, repeatability and detection limit (IDL), method linearity, repeatability, detection limit (MDL), quantitation limit (LOQ) and recovery. The method was successfully used to analyse both plasma and urine samples following a subcutaneous administration of lignocaine to a thoroughbred horse.  相似文献   

6.
Li J  Jiang J  Leung FC 《Gene》2012,494(1):57-64
Next generation 454 pyrosequencing technology for whole bacterial genome sequencing involves a deep sequencing strategy with at least 15-20 × in depth proposed by official protocols but usually done with over 20 × in practices. In this study, we carried out a comprehensive evaluation of quality of the de novo assemblies based on realistic pyrosequencing simulated data from 1480 prokaryote genomes and 7 runs of machine-generated data. Our results demonstrated that for most of the prokaryote genomes, 6-10 × sequencing in qualified runs with 400 bp reads could produce high quality draft assembly (> 98% genome coverage, < 100 contigs with N50 size > 100 kb, single base accuracy > 99.99, indel error rate < 0.01%, false gene loss/duplication rate < 0.5%). Our study proves the power of low depth pyrosequencing strategy, which provides a cost-effective way for sequencing whole prokaryote genomes in a short time and enables further studies in microbial population diversity and comparative genomics.  相似文献   

7.
According to World Health Organization statistics of 2011, infectious diseases remain in the top five causes of mortality worldwide. However, despite sophisticated research tools for microbial detection, rapid and accurate molecular diagnostics for identification of infection in humans have not been extensively adopted. Time-consuming culture-based methods remain to the forefront of clinical microbial detection. The 16S rRNA gene, a molecular marker for identification of bacterial species, is ubiquitous to members of this domain and, thanks to ever-expanding databases of sequence information, a useful tool for bacterial identification. In this study, we assembled an extensive repository of clinical isolates (n = 617), representing 30 medically important pathogenic species and originally identified using traditional culture-based or non-16S molecular methods. This strain repository was used to systematically evaluate the ability of 16S rRNA for species level identification. To enable the most accurate species level classification based on the paucity of sequence data accumulated in public databases, we built a Naïve Bayes classifier representing a diverse set of high-quality sequences from medically important bacterial organisms. We show that for species identification, a model-based approach is superior to an alignment based method. Overall, between 16S gene based and clinical identities, our study shows a genus-level concordance rate of 96% and a species-level concordance rate of 87.5%. We point to multiple cases of probable clinical misidentification with traditional culture based identification across a wide range of gram-negative rods and gram-positive cocci as well as common gram-negative cocci.  相似文献   

8.
A novel sensitive method has been developed for the detection of adenosine (AD) in human urine by using enhanced resonance light scattering (RLS). This method is based on the specific recognition and signal amplification of adenosine aptamer (Apt) coupled with gold nanoparticles (GNPs) via G-quartet-induced nanoparticle assembly, which was fabricated by triggering a structure switching of the 3′ terminus G-rich sequence and aptamer duplex. RLS signal linearly correlated with the concentration of adenosine over the range of 6-115 nM. The limit of detection (LOD) for adenosine is 1.8 nM with relative standard deviations (RSD) of 2.90-4.80% (n = 6). The present method has been successfully applied to determination of adenosine in real human urine, and the obtained results were in good agreement with those obtained by the HPLC method. Our investigation shows that the combination of the excellent selectivity of aptamer with the high sensitivity of the RLS technique could provide a promising potential for aptamer-based small molecule detection, and be beneficial in extending the application of RLS.  相似文献   

9.
A highly sensitive and convenient method to detect malondialdehyde (MDA) in specimens of plasma and urine was developed using high-performance liquid chromatography combining chemiluminescence detection. MDA was separated through a reverse-phase C18 column at a flow rate of 0.8 ml min−1. It was then detected by a chemiluminescence detector. Variables that affected chemiluminescence reaction, including mobile phase, flow rate, chemiluminescence reagent, parameters of the photomultiplier tube, and temperature, were studied. This assay was linear from 0.50 to 50 μmol L−1, with limits of detection and quantification of 0.08 and 0.30 μmol L−1, respectively. The recoveries were in the range of 92.2 to 98.5%, and the intra- and interday reproducibilities were obtained with relative standard deviations of less than 4% and less than 6%, respectively. MDA in plasma and urine was stable for 12 h at 4 °C. MDA levels were 2.74, 3.19, and 3.20 μmol L−1 for plasma and 1.25, 2.04, and 1.58 μmol L−1 for urine, respectively. The proposed method is simple, rapid, and sensitive with low cost. Taken together, this method can be suitable for detecting MDA in tissue and feed specimens.  相似文献   

10.
The Limulus in vitro endotoxin assay was evaluated as a possible method for the prompt detection of significant gram-negative bacteriuria in children. This assay is capable of detecting endotoxin associated with intact cell walls of viable gram-negative bacteria as well as free endotoxin. Quantitative results are obtained following a 1-h incubation of Limulus lysate and 10-fold dilutions of otherwise untreated urine. A standard curve of Limulus activity and viable cell counts of Escherichia coli and Klebsiella pneumoniae in urine demonstrated that a positive Limulus reaction at a dilution of 1:100 or 1:1,000 indicated a colony count of at least 100,000 bacteria/ml. A positive Limulus reaction only from undiluted urine or at a dilution of 1:10 indicated less than 100,000 cells/ml. These experimental observations were confirmed by comparing the Limulus test with quantitative plate counts on 209 urine specimens from a mixed pediatric population. These results indicate that the Limulus assay is a simple, accurate method for rapid presumptive detection of gram-negative bacteriuria in patients where an immediate diagnosis is needed. This test would also seem promising for screening large patient populations for bacteriuria or for monitoring the effectiveness of treatment of urinary tract infections.  相似文献   

11.
感染性疾病的病原学诊断仍以微生物的分离培养作为“金标准”,但能培养成功的仅为少数。绕过分离培养环节,以微生物rRNA/rDNA基因作为种属鉴别序列,设计通用引物(universal primer,up),用PCR扩增标本中微生物的16SrRNA或16S~23SrRNA序列,通过毛细管电泳(CE)进行单链构象多态性(SSCP)和限制性片段长度多态性(RFLP)分析,筛选基因的点突变以达到快速鉴定微生物(到属和种)。用PCR—CE—SSCP和PCR—CE—RFLP分析系统检测了呼吸道、消化道、女性生殖道标本中感染的病原菌;用PCR-CE-SSCP系统检测了男性泌尿道溶脲脲原体两个生物群。建立PCR—CE—RFLP分析系统,用非培养法鉴定技术检测脓汁、肠道和泌尿生殖道标本,检测并鉴定了临床标本中的多种病原菌;对人体肠道菌群进行定性和定量分析,用该法可协助腹泻的病原学诊断;检测生殖道常见的致病菌;用PCR—CE—SSCP系统建立了检测溶脲脲原体两个生物群的方法。微生物的非培养鉴定技术比传统方法缩短20h,为临床感染症的诊断提供快速、准确的依据。结果可见,利用16S~23SrRNA间区基因PCR—CE—RFLP和PCR—CE—SSCP系统可以达到对临床常见病原菌的快速种属鉴定,比传统的细菌培养法具有快速、准确、灵敏的优点,可用于临床感染症的病原学诊断。微生物的非培养鉴定技术将替代培养法而成为病原学诊断新的金标准。  相似文献   

12.
Leptospirosis is caused by Leptospira, gram negative spirochaetes whose microbiologic identification is difficult due to their low rate of growth and metabolic activity. In Colombia leptospirosis diagnosis is achieved by serological techniques without unified criteria for what positive titers are. In this study we compared polymerase chain reaction (PCR) with microbiological culture and dark field microscopy for the diagnosis of leptospirosis. Microbiological and molecular techniques were performed on 83 samples of urine taken from bovines in the savannahs surrounding Bogotá in Colombia, with presumptive diagnosis of leptospirosis. 117 samples of urine taken from healthy bovines were used as negative controls. 83 samples were MAT positive with titers ≥ 1:50; 81 with titers ≥ 1:100; and 66 with titers ≥ 1:200. 36% of the total samples (73/200) were Leptospira positives by microbiological culture, 32% (63/200) by dark field microscopy and 37% (74/200) by PCR. Amplicons obtained by PCR were 482 base pair long which are Leptospira specific. An amplicon of 262 base pairs typical of pathogenic Leptospira was observed in 71 out of the 74 PCR positive samples. The remaining 3 samples showed a 240 base pair amplicon which is typical of saprophytic Leptospira. PCR as a Leptospira diagnosis technique was 100% sensitive and 99% specific in comparison to microbiological culture. Kappa value of 0.99 indicated an excellent concordance between these techniques. Sensitivity and specificity reported for MAT when compared to microbiological culture was 0.95 and 0.89 with a ≥ 1:50 cut off. PCR was a reliable method for the rapid and precise diagnosis of leptospirosis when compared to traditional techniques in our study. The research presented here will be helpful to improve diagnosis and control of leptospirosis in Colombia and other endemic countries.  相似文献   

13.
Analysis of catecholamines (epinephrine, norepinephrine and dopamine) in plasma and urine is used for diagnosis and treatment of catecholamine-producing tumors. Current analytical techniques for catecholamine quantification are laborious, time-consuming and technically demanding. Our aim was to develop an automated on-line solid phase extraction method coupled to high performance liquid chromatography–tandem mass spectrometry (XLC–MS/MS) for the quantification of free catecholamines in urine. Five microlitre urine equivalent was pre-purified by automated on-line solid phase extraction, using phenylboronic acid complexation. Reversed phase (pentafluorophenylpropyl column) chromatography was applied. Mass spectrometric detection was operated in multiple reaction monitoring mode using a quadrupole tandem mass spectrometer with positive electrospray ionization. Urinary reference intervals were set in 24-h urine collections of 120 healthy subjects. XLC–MS/MS was compared with liquid chromatography with electrochemical detection (HPLC–ECD). Total run-time was 14 min. Intra- and inter-assay analytical variations were <10%. Linearity was excellent (R2 > 0.99). Quantification limits were 1.47 nmol/L, 15.8 nmol/L and 11.7 nmol/L for epinephrine, norepinephrine and dopamine, respectively. XLC–MS/MS correlated well with HPLC–ECD (correlation coefficient >0.98). Reference intervals were 1–10 μmol/mol, 10–50 μmol/mol and 60–225 μmol/mol creatinine for epinephrine, norepinephrine and dopamine, respectively. Advantages of the XLC–MS/MS catecholamine method include its high analytical performance by selective PBA affinity and high specificity and sensitivity by unique MS/MS fragmentation.  相似文献   

14.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

15.
This paper presents the development of a simple liquid chromatography–tandem mass spectrometry (LC–MS/MS) method to determine corticosteroids in bovine urine sample matrices. This method uses a single phase extraction (SPE) for cleaning of the sample with an Oasis MAX cartridge at pH 9.0–9.5 and elution by a neutral organic solvent (acetonitrile/dichloromethane), followed by separation on a GEMINI C18 column in the gradient mode with acetate buffer (pH 4.1)/methanol. A triple quadrupole mass spectrometer equipped with a multimode ion source, set to negative atmospheric pressure chemical ionization (APCI) in the multiple reaction monitoring mode was used for detection. The main advantage of this method over other commonly used methods includes the use of SPE with a low volume cartridge for sample preparation and no ion suppression effects from matrix components of the urine samples in the LC–MS/MS analysis. This allowed a reduction the quantification limits (decision limits, CCα) for the first time to 0.1 μg/L (1 and 0.2 μg/L for triamcinolone and flumethasone, respectively). The developed method was validated in accordance with the European Union Commission Decision 2002/657 EC. The recoveries and within-laboratory reproducibility varied from 77% to 115% and 87% to 107.5%, respectively, at 2, 3, and 4 μg/L levels of corticosteroids. The relative standard deviation (RSD) of the measurements was lower than 30%. The decision limit was calculated by multiplying the signal-to-noise ratio by 3 and the obtained values were in the range of 0.1–1.0 μg/L, confirmed by the analysis of twenty blank samples, which were spiked at the desired concentrations. The detection capability was calculated by the addition of the decision limit and the standard deviation followed by multiplication by 1.64 of the within-laboratory reproducibility at 2 μg/L of corticosteroids. The method was applied to four urine samples, giving concentrations of prednisolone (PRED) residues in the range from 0.3 to 0.9 μg/L.  相似文献   

16.
17.
A novel capillary electrophoresis (CE) with chemiluminescence (CL) detection method for the determination of mitoxantrone (MTX) has been developed, which based on the CL reaction of potassium ferricyanide with luminol in sodium hydroxide medium sensitized by MTX. Under optimum analytical conditions, MTX is determined over the range of 7.0 × 10−8–1.0 × 10−6 M with a detection limit of 1.0 × 10−8 M. The relative standard deviation (RSD) was 3.7%, 2.6% and 3.0% for 7.0 × 10−8, 5.0 × 10−7 and 1.0 × 10−6 M MTX (n = 11), respectively. In laboratory-built CE–CL apparatus, the proposed method has been applied to determination of MTX in commercial drug and spiked in human urine and plasma with satisfactory results.  相似文献   

18.
Here we report a method capable of quantifying ginsenoside Rg3 in human plasma and urine. The method was validated over linear range of 2.5–1000.0 ng mL−1 for plasma and 2.0–20.0 ng mL−1 for urine using ginsenoside Rg1 as I.S. Compounds were extracted with ethyl acetate and analyzed by HPLC/MS/MS (API-4000 system equipped with ESI interface and a C18 column). The inter- and intra-day precision and accuracy of QC samples were ≤8.5% relative error and were ≤14.4% relative standard deviation for plasma; were ≤5.6% and ≤13.3% for urine. The Rg3 was stable after 24 h at room temperature, 3 freeze/thaw cycles and 131 days at −30 °C. This method has been applied to pharmacokinetic study of ginsenoside Rg3 in human.  相似文献   

19.
In this article, we describe a simple, sensitive, accurate, and repeatable method for the measurement of phenol and p-cresol (4-methylphenol) in human urine and feces. We examined a number of parameters to identify an optimal extraction protocol. Purification of sample extracts was achieved by low-temperature vacuum microdistillation. Separation was achieved in approximately 15 min by high-performance liquid chromatography (HPLC) with quantification by fluorescence at 284/310 nm. Limits of detection for phenol were 2 ng/ml for urine and 20 ng/g for feces, and those for p-cresol were 10 ng/ml for urine and 100 ng/g for feces. For comparison, approximate mean values for urine are 3 μg/ml for phenol and 30 μg/ml for p-cresol, and those for feces are 1 μg/g for phenol and 50 μg/g for p-cresol. An experienced analyst can process 60 samples each day using this method.  相似文献   

20.
We have developed a highly selective and sensitive analytical method to quantify paraquat and diquat by use of high-performance liquid chromatography-tandem mass spectrometry (HPLC–MS/MS). The sample preparation includes solid phase extraction that uses weak cation exchange cartridges. These highly charged dual quaternary amines were not retained by standard reversed phase columns, but they could be adequately separated through HPLC with a HILIC column. The detection was carried out with a triple quadrupole mass spectrometer with an electrospray ionization probe in positive ion mode in multiple reaction monitoring. Repeated analysis in human urine samples spiked with low (5 ng/ml), medium (15 ng/ml), and high (30 ng/ml) concentrations of the analytes yielded relative standard deviations of less than 9%. The extraction efficiencies ranged from 77.7% to 94.2%. The limits of detection were in the range of 1 ng/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号