首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and specific high-performance liquid chromatographic–tandem mass spectrometric (HPLC–MS–MS) method was developed for the determination of 3-hydroxypropylmercapturic acid (3-HPMA) in human urine. Samples were extracted using ENV+ cartridges and then injected onto a C8 Superspher Select B column with acetonitrile and formic acid as eluent (5:95, v/v). N-Acetylcysteine was used as internal standard for HPLC–MS–MS. Linearity was given in the tested range of 50–5000 ng/ml urine. The limit of quantification was 50 ng/ml. Precision, as C.V., in the tested range of 50–5000 ng/ml was 1.47–6.04%. Accuracy ranged from 87 to 114%. 3-HPMA was stable in human urine at 37°C for 24 h. The method was able to quantify 3-HPMA in urine of non-smokers and smokers.  相似文献   

2.
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modern integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23s. The isotope-labeled D(6)-bupropion and D(6)-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections.  相似文献   

3.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

4.
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.  相似文献   

5.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

6.
In vitro drug interaction data can be used in guiding clinical interaction studies, or, the design of new candidates. To make such a claim, it must be assured that the in vitro data obtained is confident. To meet this need, a rapid liquid chromatography-tandem mass spectrometry (LC/MS/MS) method has been validated and employed for routine screening of new chemical entities for inhibition of six major human cytochrome P450 (CYP) isoforms using cDNA-expressed CYPs. Probe substrates were used near the Michaelis-Menten constant (K(m)) concentration values for CYP1A2 (phenacetin), CYP2C9 (tolbutamide), CYP2C19 (S-mephenytoin), CYP2D6 (dextromethorphan) and CYP3A4 (midazolam and dextromethorphan). The major metabolites of CYP-specific probe substrates were quantified. The LC/MS/MS method was found to be accurate and precise within the linear range of 1.0-2000 ng/ml for each analyte in enzyme incubation mixture. The lower limit of quantification (LLOQ) was 1.0 ng/ml. The limit of detection (LOD) for the tested analytes was 0.48 ng/ml or better based on signal-to-noise ratio >3. The inhibition potential of the six CYP isoforms has been evaluated using their known selective inhibitors. The 50% inhibitory concentrations (IC(50) values) measured by this method demonstrated high precision and are consistent with the literature values.  相似文献   

7.
A high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) procedure for the simultaneous determination of diazepam from avizafone, atropine and pralidoxime in human plasma is described. Sample pretreatment consisted of protein precipitation from 100microl of plasma using acetonitrile containing the internal standard (diazepam D5). Chromatographic separation was performed on a X-Terra MS C8 column (100mmx2.1mm, i.d. 3.5microm), with a quick stepwise gradient using a formate buffer (pH 3, 2mM) and acetonitrile at a flow rate of 0.2ml/min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges of 1-500ng/ml for diazepam, 0.25-50ng/ml for atropine and 5-1000ng/ml for pralidoxime. The coefficients of variation were always <15% for both intra-day and inter-day precision for each analyte. Mean accuracies were also within +/-15%. This method has been successfully applied to a pharmacokinetic study of the three compounds after intramuscular injection of an avizafone-atropine-pralidoxime combination, in healthy subjects.  相似文献   

8.
Analysis of wines, grape juices and cranberry juices forAlternaria toxins   总被引:1,自引:0,他引:1  
Sixty six samples of red and white wine from Ontario (VQA), British Columbia (VQA), Québec (“vins artisanaux”), imported wines (from Italy, South America and USA) and Canadian and US grape and cranberry juices were analysed for theAlternaria mycotoxins alternariol (AOH) and alternariol monomethyl ether (AME). After cleanup on aminopropyl SPE columns, AOH and AME were initially determined by reversed phase LC with UV detection. Positive sample extracts were re-analysed by LC-tandem negative ion electrospray mass spectrometry (MS/MS) in multiple reaction mode. Overall mean method recoveries measured by LC-UV were 93% for AOH and 81% for AME. Limits of detection in wine (and juice) by LC-UV for AOH were 0.8 (0.4) ng/ml and for AME were 0.5 (0.4) ng/ml; they were below 0.01 ng/ml by LC-MS/MS. As determined by LC-MS/MS, AOH was found in 13/17 Canadian red wines at levels of 0.03 to 5.02 ng/ml and in 7/7 imported red wines at 0.27–19.4 ng/ml, usually accompanied by lower concentrations of AME. Red grape juices (5 positive/10 samples) contained only sub ng/ml levels of AOH or AME except for one sample (39 ng AME/ml). White wines (3/23 samples), white grape juices (0/4 samples) and cranberry juices (1/5 samples) contained little AOH/AME (≤1.5 ng/ml). Presented at the World Mycotoxin Forum, Noordwijk, The Netherlands, November 10–11, 2005  相似文献   

9.
Zhao M  Baker SD  Yan X  Zhao Y  Wright WW  Zirkin BR  Jarow JP 《Steroids》2004,69(11-12):721-726
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra C18 (150 mm x 2.1 mm i.d., 3.5 microm) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 microl, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 2.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid.  相似文献   

10.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

11.
A simple, sensitive and reliable method was developed to determine simultaneously the concentrations of thienorphine and its metabolite thienorphine glucuronide conjugate in rat plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The metabolite was identified by MS: thienorphine glucuronide conjugate. Sample preparation involved protein precipitation with methanol. Analytes were separated on Finnigan BetaBasic-18 column (150 mm x 2.1mm i.d., 5 microm) using methanol: water: formic acid (56:44:0.1, v/v/v) as mobile phase at a flow rate of 0.2 ml/min. The method had a linear calibration curve over the concentration range of 0.1-50 ng/ml for thienorphine and 2-1000 ng/ml for thienorphine glucuronide conjugate, respectively. LOQ of thienorphine and thienorphine glucuronide conjugate was 0.1 and 2 ng/ml, respectively. The intra- and inter-batch precisions were less than 12% and their recoveries were greater than 80%. Pharmacokinetic data of thienorphine and its metabolite thienorphine glucuronide conjugate obtained with this method following a single oral dose of 3mg/kg thienorphine to rats were also reported for the first time.  相似文献   

12.
A method for the simultaneous quantitation of cerivastatin (acid) and its biotransformation products, cerivastatin lactone, M-1 (acid), M-1 lactone, M-23 (acid), M-23 lactone, M-24 (acid) and M-24 lactone, in human serum by high-performance liquid chromatography (LC) with positive ion electrospray tandem mass spectrometry (MS–MS) was developed and validated. The method involves extraction of cerivastatin and its biotransformation products from acidified human serum (0.5 ml) using methyl tert.-butyl ether. The standard curve ranges in human serum were from 0.0100 to 10.0 ng/ml for cerivastatin and cerivastatin lactone, 0.0500 to 10.0 ng/ml for M-1 (acid) and M-1 lactone, 0.100 to 10.0 ng/ml for M-23 (acid) and M-23 lactone, and 0.500 to 10.0 ng/ml for M-24 (acid) and M-24 lactone. The lactone compounds in human serum at room temperature underwent considerable conversion to the corresponding acid compounds after only 4 h. Lowering the serum pH with a pH 5.0 buffer stabilized the lactone compounds for up to 24 h at room temperature. The degree of lactonization of the acid compounds was ≤3.5% and the degree of hydrolysis of the lactone compounds was ≤6.0% during the entire assay procedure. All the eight analytes eluted within 2.0 min and the total run time was only 3.5 min.  相似文献   

13.
Hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method was validated with algal samples for verification and quantification of saxitoxin (STX), a potent neurotoxin which is listed in the Chemical Weapons Convention (CWC) in Schedule 1A. Isocratic elution, conventional bore HILIC column and high flow rate together with accurate post-column splitter provided detection of STX in 6.5 min with total analysis time of 9 min per sample. STX analogue, gonyautoxin 1 (GTX 1) was used as an internal standard. Sample preparation of freeze-dried algae included liquid extraction and centrifugal filtering with mean recovery of 99.9% at concentration level of 10 ng/ml (n=3). Retention times for STX and GTX 1 were 6.47±0.03 min and 4.44±0.01 min (n=45), respectively. Four diagnostic product ions were used for reliable verification of saxitoxin. Method was found to be precise and linear (R(2)=0.9714 and R(2)=0.9768) in concentration ranges of 5-50 ng/ml and 25-200 ng/ml, respectively. For saxitoxin, calculated LOD was 3 ng/ml and LLOQ 11 ng/ml. Validation was conducted using spiked algal matrix since this method is not only needed for verification analysis for the CWC but also for safety analysis of other environmental samples for presence of STX. Identification criteria for verification of STX with HILIC-MS/MS method are discussed.  相似文献   

14.
Dexamethasone (DXM) is a synthetic glucocorticoid that is authorized for therapeutic use in veterinary medicine. The European Community (EC) fixed a maximum residue limit (MRL) at 2ng/g for liver, 0.75ng/g for muscle and kidney tissues, and 0.3ng/ml for milk, while its use as growth-promoter is completely banned. The purpose of this study was to develop and validate a simple and reliable method to determine DXM residues in bovine milk. Milk proteins were removed by the addition of concentrated trichloroacetic acid and paper filtration. Solid-phase extraction clean-up on a C18 reversed phase column was performed to obtain an extract suitable for liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Chromatographic separation of DXM and the internal standard desoximetasone, was achieved on a PLRP-S polymeric reversed phase column, using a mixture of 0.1% (v/v) acetic acid in water (mobile phase A) and acetonitrile (mobile phase B) as the mobile phases. They were identified using the MS/MS detection technique, and were subsequently quantified. The method has been validated according to the requirements of the EC at 0.15, 0.30 and 0.60ng/ml (being half the MRL, the MRL and double the MRL levels fixed by the EC). Calibration graphs were prepared in the 0.15-5ng/ml range and good linearity was achieved (r>or=0.99 and goodness of fit 相似文献   

15.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

16.
A sensitive, simple and highly selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and evaluated to determine simultaneously the concentrations of pseudoephedrine and cetirizine in human plasma. The chief benefit of the present method is the minimal sample preparation, as the procedure is only one-step protein precipitation. Two drugs were separated on a C(8) column and analyzed by LC/MS/MS using positive electrospray ionisation (ESI). The method had a chromatographic run time of 12.0 min and a linear calibration curve over the concentration range of 1.0-800 ng/ml for pseudoephedrine and 1.0-400 ng/ml for cetirizine, respectively. The lower limit of quantification of the two drugs was 1.0 ng/ml, respectively. The intra- and inter-batch precisions were less than 9.7%. The method described herein has been first used to reveal the pharmacokinetic characters in healthy Chinese volunteers treated with oral administration of different dosages of cetirizine dihydrochloride and controlled-released pseudoephedrine hydrochloride compound tablet, and approached the influence of a standard meal on the extent and rate of absorption of the combination tablet.  相似文献   

17.
We developed a method for determining ebastine, a new generation of antihistamines, and its three metabolites (hydroxyebastine, carebastine and desalkylebastine) in plasma simultaneously using LC/MS/MS. Four compounds and terfenadine, an internal standard, were extracted from plasma using a mixture of diethylether and dichloromethane in the presence of 1 M HCl. After drying the organic layer, the residue was reconstituted in mobile phase (acetonitrile:5 mM ammonium acetate, 50:50, v/v) and injected onto a reversed-phase C(18) column. The isocratic mobile phase was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 470.7-->167.1, 486.7-->167.1, 500.6-->167.1, 268.4-->167.1 and 472.7-->436.0 for ebastine, hydroxyebastine, carebastine, desalkylebastine and terfenadine, respectively. The coefficient of variation of the assay precision was less than 12.5%, and the accuracy exceeded 88%. The limit of detection was 0.5 ng/ml for desalkylebastine; 0.2 ng/ml for ebastine, hydroxyebastine and carebastine, respectively. This method was used to measure the plasma concentration of ebastine and its three metabolites from healthy subjects after a single 20 mg oral dose of ebastine. This analytic method is a very simple, sensitive, and accurate to determine the pharmacokinetic profiles of ebastine including its metabolites.  相似文献   

18.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

19.
A fast and reliable liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI-MS/MS) method was developed and validated for the quantification of voriconazole in human plasma. The proposed method was validated in a linear range of 50-10,000 ng/ml, and the total run time was 1.5 min. This method was successfully used to support routine therapeutic drug monitoring of voriconazole.  相似文献   

20.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号