首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Blood damage and thrombosis are major complications that are commonly seen in patients with implanted mechanical heart valves. For this in vitro study, we isolated the closing phase of a bileaflet mechanical heart valve to study near valve fluid velocities and stresses. By manipulating the valve housing, we gained optical access to a previously inaccessible region of the flow. Laser Doppler velocimetry and particle image velocimetry were used to characterize the flow regime and help to identify the key design characteristics responsible for high shear and rotational flow. Impact of the closing mechanical leaflet with its rigid housing produced the highest fluid stresses observed during the cardiac cycle. Mean velocities as high as 2.4 m/s were observed at the initial valve impact. The velocities measured at the leaflet tip resulted in sustained shear rates in the range of 1500-3500 s(-1), with peak values on the order of 11,000-23,000 s(-1). Using velocity maps, we identified regurgitation zones near the valve tip and through the central orifice of the valve. Entrained flow from the transvalvular jets and flow shed off the leaflet tip during closure combined to generate a dominant vortex posterior to both leaflets after each valve closing cycle. The strength of the peripheral vortex peaked within 2 ms of the initial impact of the leaflet with the housing and rapidly dissipated thereafter, whereas the vortex near the central orifice continued to grow during the rebound phase of the valve. Rebound of the leaflets played a secondary role in sustaining closure-induced vortices.  相似文献   

2.
Two different aortic prostheses can be used for performing the Bentall procedure: a standard straight graft and the Valsalva graft that better reproduces the aortic root anatomy. The aim of the present work is to study the effect of the graft geometry on the blood flow when a bileaflet mechanical heart valve is used, as well as to evaluate the stress concentration near the suture line where the coronary arteries are connected to graft. An accurate three-dimensional numerical method is proposed, based on the immersed boundary technique. The method accounts for the interactions between the flow and the motion of the rigid leaflets and of the deformable aortic root, under physiological pulsatile conditions. The results show that the graft geometry only slightly influences the leaflets dynamics, while using the Valsalva graft the stress level near the coronary-root anastomoses is about half that obtained using the standard straight graft.  相似文献   

3.
The performance of the heart after a mitral valve replacement operation greatly depends on the flow character downstream of the valve. The design and implanting orientation of valves may considerably affect the flow development. A study of the hemodynamics of two orientations, anatomical and anti-anatomical, of the St. Jude Medical (SJM) bileaflet valve are presented and compared with those of the SJM Biocor porcine valve, which served also to represent the natural valve. We document the velocity field in a flexible, transparent (LV) using time-resolved digital particle image velocimetry (TRDPIV). Vortex formation and vortex interaction are two important physical phenomena that dominate the filling and emptying of the ventricle. For the three configurations, the following effects were examined: mitral valve inlet jet asymmetry, survival of vortical structures upstream of the aortic valve, vortex-induced velocities and redirection of theflow in abidance of the Biot-Savart law, domain segmentation, resonant times of vortical structures, and regions of stagnantflow. The presence of three distinct flow patterns, for the three configurations, was identified by the location of vortical structures and level of coherence corresponding to a significant variation in the turbulence level distribution inside the LV. The adverse effect of these observations could potentially compromise the efficiency of the LV and result in flow patterns that deviate from those in the natural heart.  相似文献   

4.
Time-accurate, fully 3D numerical simulations and particle image velocity laboratory experiments are carried out for flow through a fully open bileaflet mechanical heart valve under steady (nonpulsatile) inflow conditions. Flows at two different Reynolds numbers, one in the laminar regime and the other turbulent (near-peak systole flow rate), are investigated. A direct numerical simulation is carried out for the laminar flow case while the turbulent flow is investigated with two different unsteady statistical turbulence modeling approaches, unsteady Reynolds-averaged Navier-Stokes (URANS) and detached-eddy simulation (DES) approach. For both the laminar and turbulent cases the computed mean velocity profiles are in good overall agreement with the measurements. For the turbulent simulations, however, the comparisons with the measurements demonstrate clearly the superiority of the DES approach and underscore its potential as a powerful modeling tool of cardiovascular flows at physiological conditions. The study reveals numerous previously unknown features of the flow.  相似文献   

5.
Despite pressing needs, there are currently no FDA approved prosthetic valves available for use in the pediatric population. This study is performed for predictive assessment of blood damage in bileaflet mechanical heart valves (BMHVs) with pediatric sizing and flow conditions. A model of an adult-sized 23 mm St. Jude Medical (SJM) Regent valve is selected for use in simulations, which is scaled in size for a 5-year old child and 6-month old infant. A previously validated lattice-Boltzmann method (LBM) is used to simulate pulsatile flow with thousands of suspended platelets for cases of adult, child, and infant BMHV flows. Adult BMHV flows demonstrate more disorganized small-scale flow features, but pediatric flows are associated with higher fluid shear stresses. Platelet damage in the pediatric cases is higher than in adult flow, highlighting thrombus complication dangers of pediatric BMHV flows. This does not necessarily suggest clinically important differences in thromboembolic potential. Highly damaged platelets in pediatric flows are primarily found far downstream of the valve, as there is less flow recirculation in pediatric flows. In addition, damage levels are well below expected thresholds for platelet activation. The extent of differences here documented between the pediatric and adult cases is of concern, demanding particular attention when pediatric valves are designed and manufactured. However, the differences between the pediatric and adult cases are not such that development of pediatric sized valves is untenable. This study may push for eventual approval of prosthetic valves resized for the pediatric population. Further studies will be necessary to determine the validity and potential thrombotic and clinical implications of these findings.  相似文献   

6.
7.
We have recently demonstrated that the mitral valve anterior leaflet (MVAL) exhibited minimal hysteresis, no strain rate sensitivity, stress relaxation but not creep (Grashow et al., 2006, Ann Biomed Eng., 34(2), pp. 315-325; Grashow et al., 2006, Ann Biomed. Eng., 34(10), pp. 1509-1518). However, the underlying structural basis for this unique quasi-elastic mechanical behavior is presently unknown. As collagen is the major structural component of the MVAL, we investigated the relation between collagen fibril kinematics (rotation and stretch) and tissue-level mechanical properties in the MVAL under biaxial loading using small angle X-ray scattering. A novel device was developed and utilized to perform simultaneous measurements of tissue level forces and strain under a planar biaxial loading state. Collagen fibril D-period strain (epsilonD) and the fibrillar angular distribution were measured under equibiaxial tension, creep, and stress relaxation to a peak tension of 90 N/m. Results indicated that, under equibiaxial tension, collagen fibril straining did not initiate until the end of the nonlinear region of the tissue-level stress-strain curve. At higher tissue tension levels, epsilonD increased linearly with increasing tension. Changes in the angular distribution of the collagen fibrils mainly occurred in the tissue toe region. Using epsilonD, the tangent modulus of collagen fibrils was estimated to be 95.5+/-25.5 MPa, which was approximately 27 times higher than the tissue tensile tangent modulus of 3.58+/-1.83 MPa. In creep tests performed at 90 N/m equibiaxial tension for 60 min, both tissue strain and epsilonD remained constant with no observable changes over the test length. In contrast, in stress relaxation tests performed for 90 min epsilonD was found to rapidly decrease in the first 10 min followed by a slower decay rate for the remainder of the test. Using a single exponential model, the time constant for the reduction in collagen fibril strain was 8.3 min, which was smaller than the tissue-level stress relaxation time constants of 22.0 and 16.9 min in the circumferential and radial directions, respectively. Moreover, there was no change in the fibril angular distribution under both creep and stress relaxation over the test period. Our results suggest that (1) the MVAL collagen fibrils do not exhibit intrinsic viscoelastic behavior, (2) tissue relaxation results from the removal of stress from the fibrils, possibly by a slipping mechanism modulated by noncollagenous components (e.g. proteoglycans), and (3) the lack of creep but the occurrence of stress relaxation suggests a "load-locking" behavior under maintained loading conditions. These unique mechanical characteristics are likely necessary for normal valvular function.  相似文献   

8.
Clinical studies using transcranial Doppler ultrasonography in patients with mechanical heart valves (MHV) have detected gaseous emboli. The relationship of gaseous emboli release and cavitation on MHV has been a subject of debate in the literature. To study the influence of cavitation and gas content on the formation and growth of stable gas bubbles, a mock circulatory loop, which employed a Medtronic-Hall pyrolytic carbon disk valve in the mitral position, was used. A high-speed video camera allowed observation of cavitation and gas bubble release on the inflow valve surfaces as a function of cavitation intensity and carbon dioxide (CO2) concentration, while an ultrasonic monitoring system scanned the aortic outflow tract to quantify gas bubble production by calculating the gray scale levels of the images. In the absence of cavitation, no stable gas bubbles were formed. When gas bubbles were formed, they were first seen a few milliseconds after and in the vicinity of cavitation collapse. The volume of the gas bubbles detected in the aortic track increased with both increased CO2 and increased cavitation intensity. No correlation was observed between O2 concentration and bubble volume. We conclude that cavitation is an essential precursor to stable gas bubble formation, and CO2, the most soluble blood gas, is the major component of stable gas bubbles.  相似文献   

9.
10.
11.
The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional model geometry of a straight conduit with sudden expansion distal the valves, including the valve housing and detailed hinge geometry. An aortic flow waveform (60 beats/min, cardiac output 4 l/min) was applied at the inlet. The FSI formulation utilized a fully implicit coupling procedure using a separate solver for the fluid problem (FLUENT) and for the structural problem. Valve leaflet excursion and pressure differences were calculated, as well as shear stress on the leaflets and accumulated shear stress on particles released during both forward and backward flow phases through the open and closed valve, respectively. In contrast to the SJM, the ATS valve opened to less than maximal opening angle. Nevertheless, maximal and mean pressure gradients and velocity patterns through the valve orifices were comparable. Platelet stress accumulation during forward flow indicated that no platelets experienced a stress accumulation higher than 35 dyne x s/cm2, the threshold for platelet activation (Hellums criterion). However, during the regurgitation flow phase, 0.81% of the platelets in the SJM valve experienced a stress accumulation higher than 35 dyne x s/cm2, compared with 0.63% for the ATS valve. The numerical results indicate that the designs of the ATS and SJM valves, which differ mostly in their hinge mechanism, lead to different potential for platelet activation, especially during the regurgitation phase. This numerical methodology can be used to assess the effects of design parameters on the flow induced thrombogenic potential of blood recirculating devices.  相似文献   

12.
The characterization of the bileaflet mechanical heart valves (BMHVs) hinge microflow fields is a crucial step in heart valve engineering. Earlier in vitro studies of BMHV hinge flow at the aorta position in idealized straight pipes have shown that the aortic sinus shapes and sizes may have a direct impact on hinge microflow fields. In this paper, we used a numerical study to look at how different aortic sinus shapes, the downstream aortic arch geometry, and the location of the hinge recess can influence the flow fields in the hinge regions. Two geometric models for sinus were investigated: a simplified axisymmetric sinus and an idealized three-sinus aortic root model, with two different downstream geometries: a straight pipe and a simplified curved aortic arch. The flow fields of a 29-mm St Jude Medical BMHV with its four hinges were investigated. The simulations were performed throughout the entire cardiac cycle. At peak systole, recirculating flows were observed in curved downsteam aortic arch unlike in straight downstream pipe. Highly complex three-dimensional leakage flow through the hinge gap was observed in the simulation results during early diastole with the highest velocity at 4.7 m/s, whose intensity decreased toward late diastole. Also, elevated wall shear stresses were observed in the ventricular regions of the hinge recess with the highest recorded at 1.65 kPa. Different flow patterns were observed between the hinge regions in straight pipe and curved aortic arch models. We compared the four hinge regions at peak systole in an aortic arch downstream model and found that each individual hinge did not vary much in terms of the leakage flow rate through the valves.  相似文献   

13.
Cavitation is known to cause blood element damage and may introduce gaseous emboli into the cerebral circulation, increasing the patient's risk of stroke. Discovering methods to reduce the intensity of cavitation induced by mechanical heart valves (MHVs) has long been an area of interest. A novel approach for analyzing MHV cavitation is presented. A wavelet denoising method is explored because currently used analytical techniques fail to suitably unmask the cavitation signal from other valve closing sounds and noise detected with a hydrophone. Wavelet functions are used to denoise the cavitation signal during MHV closure and rebound. The wavelet technique is applied to the signal produced by closure of a 29-mm Medtronic-Hall MHV in degassed water with a gas content of 5 ppm. Valve closing dynamics are investigated under loading conditions of 500, 2500, and 4500 mm Hg/s. The results display a marked improvement in the quantity and quality of information that can be extracted from acoustic cavitation signals using the wavelet technique compared to conventional analytical techniques. Time and frequency data indicate the likelihood and characteristics of cavitation formation under specified conditions. Using this wavelet technique we observe an improved signal-to-noise ratio, an enhanced time-dependent aspect, and the potential to minimize valve closing sounds, which disguise individual cavitation events. The overall goal of this work is to eventually link specific valves with characteristic waveforms or distinct types of cavitation, thus promoting improved valve designs.  相似文献   

14.
15.
Parametric study of the low frequency oscillations occasionally observed in certain types of disc type prosthetic heart valves (PHV) are carried out using a finite element technique. The analysis is performed to determine the frequencies of the dynamic fluttering with the help of the 'ANSYS' computer program. The results show that the frequencies of the dynamic fluttering for both the circular occluders and the semi-circular occluders are at least two orders of magnitude higher than that observed in vivo. It is thus concluded that the clinically observed leaflet oscillations should not be a dynamic flutter phenomenon. Rather, the vortex shedding has been assumed to be the cause of these oscillations.  相似文献   

16.
17.
Polymer trileaflet valves offer natural hemodynamics with the potential for better durability than commercially available tissue valves. Strength and durability of polymer-based valves may be increased through fiber reinforcement. A finite element analysis of the mechanics of a statically loaded polymer trileaflet aortic heart valve has been conducted. A parametric analysis was performed to determine the effects of fiber orientation and volume density in a single and double ply model. A maximum stress value of 1.02MPa was obtained in the non-reinforced model for a transvalvular load (downstream-upstream) of 120mmHg. The maximum stress on the downstream side of the leaflet was approximately twice the maximum stress on the upstream side, and always occurred on the interface with the valve stent. The single ply model reduced the stress on the polymer matrix, with the maximum reduction of at least 64% occurring when the fiber orientation was such that the fibers ran perpendicular to the stent edge. The double ply model further reduced the stress on the polymer matrix, with the maximum reduction of greater than 86% now occurring when the fibers are oriented most perpendicular to one another.  相似文献   

18.
Around 250,000 heart valve replacements are performed every year around the world. Due their higher durability, approximately 2/3 of these replacements use mechanical prosthetic heart valves (mainly bileaflet valves). Although very efficient, these valves can be subject to valve leaflet malfunctions. These malfunctions are usually the consequence of pannus ingrowth and/or thrombus formation and represent serious and potentially fatal complications. Hence, it is important to investigate the flow field downstream of a dysfunctional mechanical heart valve to better understand its impact on blood components (red blood cells, platelets and coagulation factors) and to improve the current diagnosis techniques. Therefore, the objective of this study will be to numerically and experimentally investigate the pulsatile turbulent flow downstream of a dysfunctional bileaflet mechanical heart valve in terms of velocity field, vortex formation and potential negative effect on blood components. The results show that the flow downstream of a dysfunctional valve was characterized by abnormally elevated velocities and shear stresses as well as large scale vortices. These characteristics can predispose to blood components damage. Furthermore, valve malfunction led to an underestimation of maximal transvalvular pressure gradient, using Doppler echocardiography, when compared to numerical results. This could be explained by the shifting of the maximal velocity towards the normally functioning leaflet. As a consequence, clinicians should try, when possible, to check the maximal velocity position not only at the central orifice but also through the lateral orifices. Finding the maximal velocity in the lateral orifice could be an indication of valve dysfunction.  相似文献   

19.
In this work, we examine the dynamics of fluid flow in a mechanical heart valve when the solid inertia and leaflet compliance are important. The fluid is incompressible and Newtonian, and the leaflet is an incompressible neo-Hookean material. In the case of an inertialess leaflet, we find that the maximum valve opening angle and the time that the valve remains closed increase as the shear modulus of the leaflet decreases. More importantly, the regurgitant volume decreases with decreasing shear modulus. When we examined the forces exerted on the leaflet, we found that the downward motion of the leaflet is initiated by a vertical force exerted on its right side and, later on, by a vertical force exerted on the top side of the leaflet. In the case of solid inertia, we find that the maximum valve opening angle and the regurgitant volume are larger than in the case of an inertialess leaflet. These results highlight the importance of solid compliance in the dynamics of blood flow in a mechanical heart valve. More importantly, they indicate that mechanical heart valves with compliant leaflets may have smaller regurgitant volumes and smaller shear stresses than the ones with rigid leaflets.  相似文献   

20.

Background

While adolescent idiopathic scoliosis (AIS) produces well characterized deformation in spinal form, the effect on spinal function, namely mobility, is not well known. Better understanding of scoliotic spinal mobility could yield better treatment targets and diagnoses. The purpose of this study was to characterize the spinal mobility differences due to AIS. It was hypothesized that the AIS group would exhibit reduced mobility compared to the typical adolescent (TA) group.

Methods

Eleven adolescents with right thoracic AIS, apices T6-T10, and eleven age- and gender-matched TAs moved to their maximum bent position in sagittal and coronal plane bending tasks. A Trakstar (Ascension Technologies Burlington, VT) was used to collect position data. The study was approved by the local IRB. Using MATLAB (MathWorks, Natick, MA) normalized segmental angles were calculated for upper thoracic (UT) from T1-T3, mid thoracic (MT) from T3-T6, lower thoracic (LT) from T6-T10, thoracolumbar (TL) from T10-L1, upper lumbar (UL) from L1-L3, and thoracic from T1-L1 by subtracting the standing position from the maximum bent position and dividing by number of motion units in each segment. Mann Whitney tests (α?=?0.05) were used to determine mobility differences.

Results

The findings indicated that the AIS group had comparatively increased mobility in the periapical regions of the spine. The AIS group had an increase of 1.2° in the mid thoracic region (p?=?0.01) during flexion, an increase of 1.0° in the mid thoracic region (p?=?0.01), 1.5° in the thoracolumbar region (p?=?0.02), and 0.7° in thoracic region (p?=?0.04) during left anterior-lateral flexion, an increase of 6.0° in the upper lumbar region (p?=?0.02) during right anterior-lateral flexion, and an increase of 2.2° in the upper lumbar region during left lateral bending (p?<?0.01).

Conclusions

Participants with AIS did not have reduced mobility in sagittal or coronal motion. Contrarily, the AIS group often had a greater mobility, especially in segments directly above and below the apex. This indicates the scoliotic spine is flexible and may compensate near the apex.
  相似文献   