首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.  相似文献   

2.
A sensitive and selective liquid chromatographic method coupled with mass spectrometry (LC-MS) was developed for the quantification of phloroglucinol in human plasma. Resorcinol was used as internal standard, with plasma samples extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase. The reconstituted samples were injected into a C(18) XTerra MS column (2.1 x 100 mm) with 3.5-microm particle size. The analytical column lasted for at least 500 injections. The mobile phase was 15% acetonitrile (pH 3.0), with flow-rate at 200 microl/min. The mass spectrometer was operated in negative ion mode with selective ion monitoring (SIM). Phloroglucinol was detected without severe interferences from plasma matrix when used negative ion mode. Phloroglucinol produced a parent molecule ([M-H](-)) at m/z 125 in negative ion mode. Detection of phloroglucinol in human plasma was accurate and precise, with quantification limit at 5 ng/ml. This method has been successfully applied to a study of phloroglucinol in human specimens.  相似文献   

3.
Carboplatin is a platinum analogue that is used in a number of chemotherapeutic regimens for solid tumors, such as lung and ovarian carcinomas. Most often characterization of carboplatin's pharmacokinetic properties is based on measurement of platinum, rather than intact carboplatin. We have developed a sensitive LC-MS method for the determination of intact carboplatin in plasma ultrafiltrate and in tumor tissue. Carboplatin was extracted from rat plasma ultrafiltrate and tumor samples using solid-phase extraction cartridges and analyzed using reversed-phase chromatography with positive electrospray ionization followed by mass spectrometric detection. Using 50 microliter of plasma ultrafiltrate or 140 microliter of tumor homogenate supernatant, the extraction afforded a recovery of 58.7 and 45.8% for plasma and tumor, respectively. The mobile phase was 5% acetonitrile in 0.5% acetic acid at 0.2 ml/min that yielded a retention time of carboplatin of 2.2 min. The method has been validated at carboplatin plasma ultrafiltrate concentrations from 0.07 to 2.5 microgram/ml, and from 0.03 to 1.3 microgram/ml in tumor homogenates. The main advantages of this method compared with earlier methods are the ability to measure intact carboplatin in a sensitive and specific manner.  相似文献   

4.
Flutamide is a potent antiandrogen used for the treatment of prostatic cancer. Flutamide undergoes extensive first-pass metabolism to the pharmacologically active metabolite 2-hydroxyflutamide. A simple, sensitive, precise, accurate and specific HPLC method, using carbamazepine as the internal standard, for the determination of 2-hydroxyflutamide in human plasma was developed and validated. After addition of the internal standard, the analytes were isolated from human plasma by liquid–liquid extraction. The method was linear in the 25 to 1000 ng/ml concentration range (r>0.999). Recovery for 2-hydroxyflutamide was greater than 91.4% and for internal standard was 93.6%. The limit of quantitation was 25 ng/ml. Inter-batch precision, expressed as the relative standard deviation (RSD), ranged from 4.3 to 7.9%, and accuracy was better than 93.9%. Analysis of 2-hydroxyflutamide concentrations in plasma samples from 16 healthy volunteers following oral administration of 250 mg of flutamide provided the following pharmacokinetic data (mean±SD): Cmax, 776±400 ng/ml; AUC0–∞, 5368±2689 ng h/ml; AUC0–t, 5005±2605 ng h/ml; Tmax, 2.6±1.6 h; elimination half-life, 5.2±2.0 h.  相似文献   

5.
A method for measuring human plasma levels of nalmefene after oral and intravenous administration is presented. The method consists of a solid-phase extraction procedure followed by HPLC analysis. A cyanopropyl column is used for the solid-phase extraction and 60% (v/v) acetonitrile in dilute sodium pentanesulfonic acid solution for elution. The concentrated and filtered eluate is injected into the HPLC system, which is equipped with an electrochemical dual-electrode detector. A phenyl column is used in this HPLC system with a mobile phase containing 30% (v/v) acetonitrile in dilute sodium pentanesulfonic acid solution. A signal-to-noise ratio of 4.5 is obtained when a 1 ng/ml spiked plasma sample is analyzed. To determine the applicability of this method for human pharmacokinetic studies, nalmefene levels in plasma were measured at time points up to 24 h following oral and intravenous administration of 30 mg of nalmefene hydrochloride to two subjects. These studies demonstrated that the proposed method is sufficiently sensitive to study the pharmacokinetic profile of nalmefene in man.  相似文献   

6.
A simple, rapid and reliable method was developed for the quantification of oxymatrine (OMT) and its metabolite matrine (MT) in beagle dog plasma using a liquid-liquid extraction procedure followed by liquid chromatography-electrospray ionization mass spectrometric (LC-ESI-MS) analysis. Extend-C18 column (2.1 mm i.d. x 50 mm, 5 microm) with a C18 guard column (2.1 mm i.d. x 12.5 mm) was used as the analytical column. Linear detection responses were obtained for OMT concentration ranging from 5 to 4000 ng/ml and for MT concentration ranging from 5 to 2000 ng/ml. The precision and accuracy data, based on intra- and inter-day variations over 5 days, were lower than 5%. The limit of quantitation for OMT and MT were 2 and 1 ng/ml, respectively, and their recoveries were greater than 90%. Pharmacokinetic data of OMT and its active metabolite MT obtained with this method following a single oral dose of 300 mg OMT capsules to six beagle dogs was also reported for the first time.  相似文献   

7.
24S-Hydroxycholesterol (24S-OH-Chol) and 27-hydroxycholesterol (27-OH-Chol) are oxidized derivatives of cholesterol and of potential diagnostic interest because their circulating levels may reflect the cholesterol metabolism of the brain and macrophages, respectively. We developed a sensitive and specific HPLC-MS method for the quantification of 24S-OH-Chol and 27-OH-Chol in human plasma. In contrast to currently available procedures based on gas chromatography-mass spectrometry, this methodology offers the advantage that no time-consuming derivatization is needed. After saponification, solid-phase extraction, and HPLC separation under reversed-phase column conditions, detection by MS was performed using atmospheric pressure chemical ionization and selected ion monitoring mode. The standard curves were linear throughout the calibration range for both oxysterols. Within-day and between-day coefficients of variation were less than 9%, and the recoveries ranged between 98% and 103%. The quantification limits were 40 and 25 microg/l for 24S-OH-Chol and 27-OH-Chol, respectively. Mean values for both oxysterols were determined in plasma from 22 healthy volunteers. The sensitive and selective HPLC-MS method described here combined with the appropriate workup procedure allow the quantification of 24S-OH-Chol and 27-OH-Chol in plasma samples, for example in clinical studies to elaborate the clinical usefulness of these two oxysterols.  相似文献   

8.
A high-performance liquid chromatographic method is described for the determination of free captopril in human plasma. (NAC) was used as an internal standard. Plasma samples were immediately derivatized with N-(1-pyrenyl)maleimide (NPM) and stabilized with 11 M HCl. The drug of interest was isolated using a liquid-liquid extraction with ethyl acetate and separation was obtained using a reversed-phase column under isocratic conditions with fluorescence detection. The sample volume was 150 μl plasma. The intra- and inter-day accuracy and precision, determined as relative error and coefficient of variation respectively, were lessthan 10%. The lower limit of quantitation, based on standards with acceptable coefficients of variation, was 25 ng/ml. No endogenous compounds were found to interfere. The linearity was assessed in the range of 25–600 ng/ml. This method has been demonstrated to be suitable for pharmacokinetic studies in humans.  相似文献   

9.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of rimantadine in rat plasma. Rimantadine was extracted by protein precipitation with methanol, and the chromatographic separation was performed on a C(18) column. The total analytical run time was relatively short (4.6 min), and the limit of assay quantification (LLOQ) was 2 ng/mL using 50 microL of rat plasma. Rimantadine and the internal standard (amantadine) were monitored in selected ion monitoring (SIM) mode at m/z 180.2 and 152.1, respectively. The standard curve was linear over a concentration range from 2 to 750 ng/mL, and the correlation coefficients were greater than 0.999. The mean intra- and inter-day assay accuracy ranged from 100.1-105.0% to 100.3-104.0%, respectively, and the mean intra- and inter-day precision was between 1.3-2.3% and 1.8-3.0%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in rats after oral administration of rimantadine hydrochloride at the dose of 20 mg/kg.  相似文献   

10.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of ginsenoside Rd in dog plasma was developed and validated after solid-phase extraction (SPE).Chromatographic separation was achieved on a reversed-phase Cromosil C(18) column with the mobile phase of acetonitrile-ammonium chloride (500 micromol/L) and step gradient elution resulted in a total run time of about 5.5 min. The analytes were detected by using an electrospray negative ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.500 microg/mL) (r=0.9998). Lower limit of quantification (LLOQ) was 5 ng/mL by using 500 microL plasma sample. Average recoveries ranged from 70.71 to 75.89% in plasma at the concentrations of 0.010, 0.100 and 2.500 microg/mL. Intra- and inter-day relative standard deviations were 8.49-11.71 and 5.71-16.48%, respectively. This method was successfully applied to the pharmacokinetic studies on dogs. The absolute bioavailability of Rd in dogs was 0.26%.  相似文献   

11.
A sensitive and selective liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification and quantification of helicid in rat plasma. The method was based on simple liquid-liquid extraction (LLE). A Kromasil C18 column (150mmx2.00mm, 3.5microm) was used as the analytical column, while a mixture of acetonitrile and 500microM ammonium chloride was used as the mobile phase. MS detection was performed using a single quadrupole mass spectrometer in a negative selected ion monitoring (SIM) mode. The deprotonated molecules [M+Cl](-) at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard, I.S.), respectively. The lower limit of quantification of helicid was 1ng/ml. The method was linear in the concentration range of 1-1000ng/ml. The intra-day and inter-day precisions (R.S.D.%) were within 10.0% for the analyte. Helicid proved to be stable during all sample storage, preparation and analytical periods. The method was successfully applied to a pharmacokinetic study in rats after intragastric administration of helicid with a dose of 50mg/kg. Only 50microl of rat plasma at each sampling time was needed for analysis. The proposed method enables unambiguous identification and quantification for the preliminary pharmacokinetic studies of helicid.  相似文献   

12.
Several modifications of GC-MS and HPLC methods for plasma level DHPG have been described. The effects of storage temperature and stabilizing agents on DHPG stability have been studied. The stabilizing agent has been found to play a more important role than low-temperature storage in preventing DHPG from decomposition during sample storage. A specific and sensitive GC-MS method (electron impact) has been established using stable isotope-labeled DHPG as an internal standard. HPLC has been improved by modifying the conditions, resulting in a good separation of DHPG and internal standard from solvent front and other early eluting compounds. Comparison of the GC-MS and HPLC procedures demonstrates a strong correlation between these two methods.  相似文献   

13.
A new high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assay for cediranib, a tyrosine kinase inhibitor for VEGFRs, was developed and validated, for the determination of plasma and brain levels of cediranib in small specimen volumes. Tyrphostin (AG1478) was used as internal standard. Mouse plasma and brain homogenate samples were prepared using liquid-liquid extraction. The assay was validated for a 2.5-2500 ng/mL concentration range for plasma, and for 1-2000 ng/mL range for brain homogenate. For these calibration ranges, within-assay variabilities were 1.1-14.3% for plasma and 1.5-9.4% for brain homogenate; between-assay variabilities were 2.4-9.2% for plasma, and 4.9-10.2% for brain homogenate. Overall accuracy ranged from 101.5 to 107.0% for plasma and 96.5 to 100.2% for brain homogenate, for all target concentrations. The developed assay has been successfully applied for a brain distribution study in mice at an oral dose of 5 mg/kg.  相似文献   

14.
A simple high-performance liquid chromatographic method was developed to study the pharmacokinetics of dicentrine in rat plasma after 10 mg/kg intravenous administration. After addition of an internal standard (coumarin), plasma was deproteinized by acetonitrile for sample clean-up. The drugs were separated on a reversed-phase Nucleosil C18 column (250 × 4 mm I.D., particle size 5 μm) and detected by photodiode-array detection at a wavelength of 308 nm. Acetonitrile-water (35:65, v/v, pH 2.5–2.8, adjusted with orthophosphoric acid) was used as the mobile phase. A biphasic phenomenon with a rapid distribution followed by a slower elimination phase was observed from the plasma concentration-time curve.  相似文献   

15.
A sensitive, specific, and reproducible high-performance liquid chromatography (HPLC) method with fluorescence detection was developed for determination of lefucoxib in rat plasma, urine, and feces. The method involved liquid-liquid extraction using methyl tert-butyl ether, and celecoxib was used as the internal standard. The chromatographic separation was performed on a Kromasil C18 column (250.0 mm x 4.6 mm, 5.0 microm) with a mobile phase gradient consisting of water and methanol at a flow rate of 1 ml min(-1). The assay was linear in the range of 5.0-1000.0 ng ml(-1) with a correlation coefficient (r) of 0.9994. The limit of quantification was 5.0 ng ml(-1). Inter- and intra-assay precisions were 相似文献   

16.
A simple, sensitive and selective liquid chromatography coupled with electrospray ionization mass spectrometry (LC/ESI/MS) method for the determination of simvastatin (I) has been developed. After extraction by ethyl acetate, using lovastatin (II) as internal standard, solutes are separated on a C(18) column with a mobile phase consisting of methanol-water (9:1). Detection is performed on an atmospheric pressure ionization single quadruple mass spectrometer equipped with an ESI interface and operates in positive ionization mode. Simvastatin quantification was realized by computing peak area ratio (I/II) of the extracts analyzed in SIM mode (m/z: 441 and m/z: 427 for I and II, respectively) and comparing them with calibration curve (r=0.9997). Accuracy and precision for the assay were determined by calculating the intra-batch and inter-batch variation at three concentrations 0.1, 5.0, 10.0 ng/ml; the intra batch relative standard deviation (RSD) was less than 10% and ranged from 1.8 to 8.5%, respectively; the inter-batch RSD was less than 20% and ranged from 4.1 to 16.5%. The limit of detection was 0.05 ng/ml.  相似文献   

17.
A method for the quantitative determination of perhexiline and its main hydroxylated metabolites in human plasma, based on liquid chromatography-mass spectrometry (LC-MS), was developed. The method used protein precipitation with acetonitrile followed by dilution with water and subsequent direct injection of the extract into the LC-MS system. Hexadiline was used as internal standard and the intra-assay coefficients of variation were 相似文献   

18.
A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been described for determination of acyclovir in human serum. Since acyclovir is a polar compound and soluble in aqueous medium and practically insoluble in most of organic solvents, its analysis in biological fluids in currently published HPLC methods, involve pre-treatment of acyclovir plasma sample including deproteinization or solid phase extraction. In present method liquid-liquid extraction of acyclovir and internal standard (vanillin) is achieved using dichloromethane-isopropyl alcohol (1:1, v/v) as an extracting solvent. Analysis was carried out on ODS column using methanol-phosphate buffer (0.05 M) containing sodium dodecyl sulfate (200 mg/L) and triethylamine (2 mL/L, v/v) as mobile phase (pH=2.3; 5:95, v/v) at flow rate of 2 ml/min. The method was shown to be selective and linear into the concentration range of 10-2560 ng/mL. Accuracy and precision of the method were also studied. The limit of quantitation was evaluated to be 10 ng/mL. This method was applied in bioequivalence study of two different acyclovir preparations after administration of 400mg in 12 healthy volunteers.  相似文献   

19.
A simple, sensitive and reliable method was developed to determine simultaneously the concentrations of thienorphine and its metabolite thienorphine glucuronide conjugate in rat plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The metabolite was identified by MS: thienorphine glucuronide conjugate. Sample preparation involved protein precipitation with methanol. Analytes were separated on Finnigan BetaBasic-18 column (150 mm x 2.1mm i.d., 5 microm) using methanol: water: formic acid (56:44:0.1, v/v/v) as mobile phase at a flow rate of 0.2 ml/min. The method had a linear calibration curve over the concentration range of 0.1-50 ng/ml for thienorphine and 2-1000 ng/ml for thienorphine glucuronide conjugate, respectively. LOQ of thienorphine and thienorphine glucuronide conjugate was 0.1 and 2 ng/ml, respectively. The intra- and inter-batch precisions were less than 12% and their recoveries were greater than 80%. Pharmacokinetic data of thienorphine and its metabolite thienorphine glucuronide conjugate obtained with this method following a single oral dose of 3mg/kg thienorphine to rats were also reported for the first time.  相似文献   

20.
A sensitive method was developed to determine fexofenadine in human plasma and urine by HPLC-electrospray mass spectrometry with MDL 026042 as internal standard. Extraction was carried out on C18 solid-phase extraction cartridges. The mobile phases used for HPLC were: (A) 12 mM ammonium acetate in water and (B) acetonitrile. Chromatographic separation was achieved on a LUNA CN column (10 cm x 2.0 mm I.D., particle size 3 microm) using a linear gradient from 40% B to 60% B in 10 min. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH+ ions, m/z 502.3 for fexofenadine and m/z 530.3 for the internal standard. The limit of quantification achieved with this method was 0.5 ng/ml in plasma and 1.0 ng in 50 microl of urine. The method described was successfully applied to the determination of fexofenadine in human plasma and urine in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号