首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
为了进一步探索经颅磁刺激工作机理并改进或研制出新的经颅磁刺激激励源.本文从经颅磁刺激的原理推导出了磁场、感应电流及激励源原理电路电流的表达式,利用大脑-线圈和大脑-线圈-铁芯两种经颅磁刺激模型分析影响因素与头模型各组织的磁场和感应电流分布.对比分析表明电流的性质,线圈半径,线圈激励特性与铁芯对感应电流分布与电磁场分布有着本质的影响.对经颅磁刺激参数及结构要件的研究与分析可用于指导刺激线圈参数及激励源电路参数的设置,以及探索新的激励源制作.  相似文献   

2.
传统的电缆方程只能用于描述纵向电场中外周神经的兴奋,无法描述外周神经在横向电场作用下的兴奋,其于两阶段过程模型,提出一种改进的电缆方程,可以描述外周神经在横向电场中的兴奋,其结果和Struijk的离体实验数据相吻合。此改进的电缆方程可用于描述任意电场中外周神经的兴奋。  相似文献   

3.
We have applied static (SMF) or alternating magnetic fields (AMF) to snail (Helix aspersa) single-unit neurons, in the range of those applied in magnetic stimulation (MS)/transcranial magnetic stimulation (TMS). From the experiments we have performed during the past 10 years, we have collected a blind selection of neurons and their responses to either SMF or AMF. Blind selection means that we do not know the nature of neurons. We do not know whether they are sensitive, motor, secretory, pacemaker, or inter-neurons. We have seen that the behavior of single-unit neurons under SMF/AMF exposure (SMF range: 3 mT–0.7 T; AMF range: 1–15 mT) fits well with the electrophysiologic activity described for mammals and human whole brain under MS/TMS (pulsed magnetic field range: 0.3 mT–2.4 T). The neuron experiments shown here have been aleatorily selected from a collection of about 200 neurons studied. Our results could explain some of the effects described induced in mammal neurons under MS/TMS for clinical purposes.  相似文献   

4.
Transcranial magnetic stimulation: a primer   总被引:4,自引:0,他引:4  
Hallett M 《Neuron》2007,55(2):187-199
Transcranial magnetic stimulation (TMS) is a technique for noninvasive stimulation of the human brain. Stimulation is produced by generating a brief, high-intensity magnetic field by passing a brief electric current through a magnetic coil. The field can excite or inhibit a small area of brain below the coil. All parts of the brain just beneath the skull can be influenced, but most studies have been of the motor cortex where a focal muscle twitch can be produced, called the motor-evoked potential. The technique can be used to map brain function and explore the excitability of different regions. Brief interference has allowed mapping of many sensory, motor, and cognitive functions. TMS has some clinical utility, and, because it can influence brain function if delivered repetitively, it is being developed for various therapeutic purposes.  相似文献   

5.
Transcranial magnetic stimulation (TMS) is a technique whereby parts of the cerebral cortex and underlying white matter can be excited by a brief electrical current induced by a similarly brief, rapidly fluctuating magnetic field which is itself produced by rapidly discharging a current through an insulated coil held against the scalp. When combined with magnetic resonance structural and functional images of the subject's brain, the stimulation can be directed at specific cortical areas. Over a period of only 15 years, TMS has revealed hitherto unsuspected aspects of brain function, such as the role of distant parts of the brain in recovery from stroke, and has helped to resolve several previously intractable disputes, such as the neuronal basis of conscious awareness. This article describes and discusses the origins and nature of TMS, its applications and limitations, and its especial usefulness in conjunction with other techniques of evaluating or imaging brain activity.  相似文献   

6.
Transcranial magnetic stimulation (TMS) is increasingly being used to demonstrate the causal links between brain and behavior in humans. Further, extensive clinical trials are being conducted to investigate the therapeutic role of TMS in disorders such as depression. Because TMS causes strong peripheral effects such as auditory clicks and muscle twitches, experimental artifacts such as subject bias and placebo effect are clear concerns. Several sham TMS methods have been developed, but none of the techniques allows one to intermix real and sham TMS on a trial-by-trial basis in a double-blind manner. We have developed an attachment that allows fast, automated switching between Standard TMS and two types of control TMS (Sham and Reverse) without movement of the coil or reconfiguration of the setup. We validate the setup by performing mathematical modeling, search-coil and physiological measurements. To see if the stimulus conditions can be blinded, we conduct perceptual discrimination and sensory perception studies. We verify that the physical properties of the stimulus are appropriate, and that successive stimuli do not contaminate each other. We find that the threshold for motor activation is significantly higher for Reversed than for Standard stimulation, and that Sham stimulation entirely fails to activate muscle potentials. Subjects and experimenters perform poorly at discriminating between Sham and Standard TMS with a figure-of-eight coil, and between Reverse and Standard TMS with a circular coil. Our results raise the possibility of utilizing this technique for a wide range of applications.  相似文献   

7.
Transcranial magnetic stimulation (TMS) is a non-invasive form of brain stimulation that makes use of the magnetic field generated when an electric current passes through a magnetic coil placed over the scalp. It can be applied as a single stimulus at a time, in pairs of stimuli, or repetitively in trains of stimuli (repetitive TMS, rTMS). RTMS can induce changes in brain activity, whose after-effects reflect the processes of long-term potentiation and long-term depression, as certain protocols, namely those using low frequencies (≤1 Hz) seem to suppress cortical excitability, while those using high frequencies (>1 Hz) seem to enhance it. It is a technique with very few and mostly mild side-effects, whose effects can persist for long time periods, and as such, it has been studied as a potential treatment option in a multitude of neurodegenerative diseases, including those affecting movement. Although rTMS has received approval as a treatment strategy of only a few aspects in movement disorders in the latest guidelines, its further use seems to also be promising in their context. In this review, we gathered the available literature on the therapeutic application of rTMS in movement disorders, namely Parkinson’s disease, Amyotrophic Lateral Sclerosis, Huntington’s disease, Dystonia, Tic disorders and Essential Tremor.  相似文献   

8.
为了研究对经颅磁刺激激励线圈聚焦性能的优化,利用混合优化算法与CST软件的外部通信接口,建立优化的激励线圈模型。依据多信道线圈阵列方法,利用磁场叠加原理,对影响磁场分布的线圈可调参数进行分析,结合混合优化算法对可调参数进行优化。结果对比显示,经优化的线圈阵列有良好的磁聚焦性,其刺激强度与聚焦程度都有了不同程度提高。可用于改善TMS系统聚焦性能,实验有助于进一步探索全面优化激励线圈的空间结构。  相似文献   

9.
Electric fields, which are ubiquitous in the context of neurons, are induced either by external electromagnetic fields or by endogenous electric activities. Clinical evidences point out that magnetic stimulation can induce an electric field that modulates rhythmic activity of special brain tissue, which are associated with most brain functions, including normal and pathological physiological mechanisms. Recently, the studies about the relationship between clinical treatment for psychiatric disorders and magnetic stimulation have been investigated extensively. However, further development of these techniques is limited due to the lack of understanding of the underlying mechanisms supporting the interaction between the electric field induced by magnetic stimulus and brain tissue. In this paper, the effects of steady DC electric field induced by magnetic stimulation on the coherence of an interneuronal network are investigated. Different behaviors have been observed in the network with different topologies (i.e., random and small-world network, modular network). It is found that the coherence displays a peak or a plateau when the induced electric field varies between the parameter range we defined. The coherence of the neuronal systems depends extensively on the network structure and parameters. All these parameters play a key role in determining the range for the induced electric field to synchronize network activities. The presented results could have important implications for the scientific theoretical studies regarding the effects of magnetic stimulation on human brain.  相似文献   

10.
Transcranial magnetic stimulation (TMS) allows non-invasive manipulation of brain activity during active task performance. Because every TMS pulse is accompanied by non-neural effects such as a clicking sound and somato-sensation on the head, control conditions are required to ensure that changes in task behavior are indeed due to the induced neural effects. However, the non-neural effects of TMS in the context of a given task performance are largely unknown and, consequently, it is unclear what constitutes a valid control condition. We explored the non-neural effects of TMS on visual target detection. Participants received single pulse sham TMS to each hemisphere at different time points prior to target appearance during a visual target detection task. It was hypothesized that the clicking sound of a sham TMS pulse differentially affects performance depending on the location of the coil and the timing of the pulse.Our results show that, first, sham TMS caused a facilitation of reaction times when preceding the target stimulus by 150, 200, and 250 ms, whereas earlier and later time windows were not effective. Second, positioning the TMS coil ipsilateral instead of contralateral relative to the target stimulus improved reaction times. Third, infrequent noTMS trials that were interleaved with sham TMS trials had oddball-like properties resulting in increased reaction times during noTMS. The clicking sound produced by sham TMS influences task performance in multiple ways. These non-neural effects of TMS need to be controlled for in TMS research and the present findings provide an empirical basis for deciding what constitutes a valid control condition.  相似文献   

11.
Rotem A  Moses E 《Biophysical journal》2008,94(12):5065-5078
Transcranial magnetic stimulation is a remarkable tool for neuroscience research, with a multitude of diagnostic and therapeutic applications. Surprisingly, application of the same magnetic stimulation directly to neurons that are dissected from the brain and grown in vitro was not reported to activate them to date. Here we report that central nervous system neurons patterned on large enough one-dimensional rings can be magnetically stimulated in vitro. In contrast, two-dimensional cultures with comparable size do not respond to excitation. This happens because the one-dimensional pattern enforces an ordering of the axons along the ring, which is designed to follow the lines of the magnetically induced electric field. A small group of sensitive (i.e., initiating) neurons respond even when the network is disconnected, and are presumed to excite the entire network when it is connected. This implies that morphological and electrophysiological properties of single neurons are crucial for magnetic stimulation. We conjecture that the existence of a select group of neurons with higher sensitivity may occur in the brain in vivo as well, with consequences for transcranial magnetic stimulation.  相似文献   

12.
The objective of this study was to assess changes in corticospinal excitability and spinal output following noninvasive transpinal and transcortical stimulation in humans. The size of the motor evoked potentials (MEPs), induced by transcranial magnetic stimulation (TMS) and recorded from the right plantar flexor and extensor muscles, was assessed following transcutaneous electric stimulation of the spine (tsESS) over the thoracolumbar region at conditioning-test (C-T) intervals that ranged from negative 50 to positive 50 ms. The size of the transpinal evoked potentials (TEPs), induced by tsESS and recorded from the right and left plantar flexor and extensor muscles, was assessed following TMS over the left primary motor cortex at 0.7 and at 1.1× MEP resting threshold at C-T intervals that ranged from negative 50 to positive 50 ms. The recruitment curves of MEPs and TEPs had a similar shape, and statistically significant differences between the sigmoid function parameters of MEPs and TEPs were not found. Anodal tsESS resulted in early MEP depression followed by long-latency MEP facilitation of both ankle plantar flexors and extensors. TEPs of ankle plantar flexors and extensors were increased regardless TMS intensity level. Subthreshold and suprathreshold TMS induced short-latency TEP facilitation that was larger in the TEPs ipsilateral to TMS. Noninvasive transpinal stimulation affected ipsilateral and contralateral actions of corticospinal neurons, while corticocortical and corticospinal descending volleys increased TEPs in both limbs. Transpinal and transcortical stimulation is a noninvasive neuromodulation method that alters corticospinal excitability and increases motor output of multiple spinal segments in humans.  相似文献   

13.
We investigated the effects of pulsed magnetic stimulation on tumor development processes and immune functions in mice. A circular coil (inner diameter = 15 mm, outer diameter = 75 mm) was used in the experiments. Stimulus conditions were pulse width = 238 micros, peak magnetic field = 0.25 T (at the center of the coil), frequency = 25 pulses/s, 1,000 pulses/sample/day and magnetically induced eddy currents in mice = 0.79-1.54 A/m(2). In an animal study, B16-BL6 melanoma model mice were exposed to the pulsed magnetic stimulation for 16 days from the day of injection of cancer cells. A tumor growth study revealed a significant tumor weight decrease in the stimulated group (54% of the sham group). In a cellular study, B16-BL6 cells were also exposed to the magnetic field (1,000 pulses/sample, and eddy currents at the bottom of the dish = 2.36-2.90 A/m(2)); however, the magnetically induced eddy currents had no effect on cell viabilities. Cytokine production in mouse spleens was measured to analyze the immunomodulatory effect after the pulsed magnetic stimulation. tumor necrosis factor (TNF-alpha) production in mouse spleens was significantly activated after the exposure of the stimulus condition described above. These results showed the first evidence of the anti-tumor effect and immunomodulatory effects brought about by the application of repetitive magnetic stimulation and also suggested the possible relationship between anti-tumor effects and the increase of TNF-alpha levels caused by pulsed magnetic stimulation.  相似文献   

14.
We suggest an experimental comparison of two directions for applying the time-varying magnetic fields which have been found to speed spontaneous regeneration of injured peripheral nerves and in attempts to repair spinal cord injuries. Time-varying magnetic fields induce currents in a plane perpendicular to the magnetic field direction. The lower conductivity of the spinal cord's sheath (dura matter) or of the myelin sheath of peripheral nerves would seem to confine the induced electric fields and currents to the spinal cord or nerve itself. The proposed comparison could allow choosing between two possible modes of action of the fields: (1) Magnetically-induced electric fields or currents may be encouraging ion flow or otherwise helping enzyme, channel or other interactions at the cell membrane, as is thought to be the case in field stimulation of healing in bone. This mechanism should be independent of field direction. (2) Work in developing organisms and with fields applied to nerve cells in vitro has shown that neurite growth is guided parallel to both endogenous and external electric fields. This mechanism would be effective when induced electric fields are parallel, but not when they are perpendicular to the nerve. Any experimental test should seek to produce as close as possible to the same induced current intensity with both field directions. Possible confounding factors, as well as breakdowns in the assumptions of the simple model presented here, would have to be considered. This proposal was motivated by a recent report in which the authors listed a changed field direction as one of several possible reasons for an unsuccessful experiment.  相似文献   

15.
Calculations are presented of the induced electric fields and current densities in the cartilage of the knee produced by a coil applicator developed for applying pulsed magnetic fields to osteoarthritic knees. This applicator produces a sawtooth-like magnetic field waveform composed of a series of 260-micros pulses with a peak to peak magnitude of approximately 0.12 mT in the cartilage region. The simulations were performed using a recently developed 3 dimensional finite difference frequency domain technique for solving Maxwell's equations with an equivalent circuit model. The tissue model was obtained from the anatomically segmented human body model of Gandhi. The temporal peak electric field magnitude was found to be -153 mV/m, averaged within the medial cartilage of the knee for the typical dB/dt excitation levels of this coil. The technique can be extended to analyze other excitation waveforms and applicator designs.  相似文献   

16.
Experimental autoimmune encephalomyelitis (EAE) reproduces a multiple sclerosis (MS)-like experimental model. The main objective was to evaluate the effect of extremely low-frequency electromagnetic fields (EL-EMF) application, like a paradigm of transcranial magnetic stimulation (TMS) in the development of EAE. Rats were injected with a single dose of 150?μg of myelin oligodendrocyte glycoprotein (MOG, fragment 35–55) to produce experimental MS. To assess the effect of TMS application in EAE, the rats were treated with TMS (60?Hz and 0.7?mT) for 2?h in the morning, once a day, 5 days a week, during 3 weeks. TMS was applied to the head. The effect of TMS on EAE was evaluated as motor symptoms and, oxidative and cell damage. The data showed that MOG induced motor symptoms as tail paralysis and limb paresis/paralysis, oxidative stress and cell death similar to MS when compared with control animals. Importantly, TMS application attenuated motor symptoms, oxidative and cell damage, whereas it increased antioxidant system. Our findings suggest that: (i) MOG reproduces an experimental model of MS characterised by oxidative and cell damage; and (ii) TMS application decreases oxidative stress and cell death induced by MOG.  相似文献   

17.
The calcium dependent plasticity (CaDP) approach to the modeling of synaptic weight change is applied using a neural field approach to realistic repetitive transcranial magnetic stimulation (rTMS) protocols. A spatially-symmetric nonlinear neural field model consisting of populations of excitatory and inhibitory neurons is used. The plasticity between excitatory cell populations is then evaluated using a CaDP approach that incorporates metaplasticity. The direction and size of the plasticity (potentiation or depression) depends on both the amplitude of stimulation and duration of the protocol. The breaks in the inhibitory theta-burst stimulation protocol are crucial to ensuring that the stimulation bursts are potentiating in nature. Tuning the parameters of a spike-timing dependent plasticity (STDP) window with a Monte Carlo approach to maximize agreement between STDP predictions and the CaDP results reproduces a realistically-shaped window with two regions of depression in agreement with the existing literature. Developing understanding of how TMS interacts with cells at a network level may be important for future investigation.  相似文献   

18.
BACKGROUND: Regions in human frontal cortex may have modulatory top-down influences on retinotopic visual cortex, but to date neuroimaging methods have only been able to provide indirect evidence for such functional interactions between remote but interconnected brain regions. Here we combined transcranial magnetic stimulation (TMS) with concurrent functional magnetic resonance imaging (fMRI), plus psychophysics, to show that stimulation of the right human frontal eye-field (FEF) produced a characteristic topographic pattern of activity changes in retinotopic visual areas V1-V4, with functional consequences for visual perception. RESULTS: FEF TMS led to activity increases for retinotopic representations of the peripheral visual field, but to activity decreases for the central field, in areas V1-V4. These frontal influences on visual cortex occurred in a top-down manner, independently of visual input. TMS of a control site (vertex) did not elicit such visual modulations, and saccades, blinks, or pupil dilation could not account for our results. Finally, the effects of FEF TMS on activity in retinotopic visual cortex led to a behavioral prediction that we confirmed psychophysically by showing that TMS of the frontal site (again compared with vertex) enhanced perceived contrast for peripheral relative to central visual stimuli. CONCLUSIONS: Our results provide causal evidence that circuits originating in the human FEF can modulate activity in retinotopic visual cortex, in a manner that differentiates the central and peripheral visual field, with functional consequences for perception. More generally, our study illustrates how the new approach of concurrent TMS-fMRI can now reveal causal interactions between remote but interconnected areas of the human brain.  相似文献   

19.
Several studies demonstrated in experimental models and in humans synaptic plasticity impairment in some neurodegenerative and neuropsychiatric diseases such as Parkinson's disease, Alzheimer's disease, Huntington's disease, and schizophrenia. Recently new neurophysiological tools, such as repetitive transcranial magnetic stimulation and transcranial direct current stimulation, have been introduced in experimental and clinical settings for studying physiology of the brain and modulating cortical activity. These techniques use noninvasive transcranial electrical or magnetic stimulation to modulate neurons activity in the human brain. Cortical stimulation might enhance or inhibit the activity of cortico?Csubcortical networks, depending on stimulus frequency and intensity, current polarity, and other stimulation parameters such as the configuration of the induced electric field and stimulation protocols. On this basis, in the last two decades, these techniques have rapidly become valuable tools to investigate physiology of the human brain and have been applied to treat drug-resistant neurological and psychiatric diseases. Here we describe these techniques and discuss the mechanisms that may explain these effects.  相似文献   

20.
A system is described that is capable of producing extremely low frequency (ELF) magnetic fields for relatively short-term exposure of cultured mammalian cells. The system utilizes a ferromagnetic core to contain and direct the magnetic field of a 1,000 turn solenoidal coil and can produce a range of flux densities and induced electric fields much higher than those produced by Helmholtz coils. The system can generate magnetic fields from the microtesla (μT) range up to 0.14 T with induced electric field strengths on the order of 1.0 V/m. The induced electric field can be accurately varied by changing the sample chamber configuration without changing the exposure magnetic field. This gives the system the ability to separate the bioeffects of magnetic and induced electric fields. In the frequency range of 4–100 Hz and magnetic flux density range of 0.005–0.14 T, the maximum total harmonic distortion of the induced electric field is typically less than 1.0%. The temperature of the samples is held constant to within 0.4°C by constant perfusion of warmed culture medium through the sample chamber. © 1993 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号