首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Medical technologies are indispensable to modern medicine. However, they have become exceedingly expensive and complex and are not available to the economically disadvantaged majority of the world population in underdeveloped as well as developed parts of the world. For example, according to the World Health Organization about two thirds of the world population does not have access to medical imaging. In this paper we introduce a new medical technology paradigm centered on wireless technology and cloud computing that was designed to overcome the problems of increasing health technology costs. We demonstrate the value of the concept with an example; the design of a wireless, distributed network and central (cloud) computing enabled three-dimensional (3-D) ultrasound system. Specifically, we demonstrate the feasibility of producing a 3-D high end ultrasound scan at a central computing facility using the raw data acquired at the remote patient site with an inexpensive low end ultrasound transducer designed for 2-D, through a mobile device and wireless connection link between them. Producing high-end 3D ultrasound images with simple low-end transducers reduces the cost of imaging by orders of magnitude. It also removes the requirement of having a highly trained imaging expert at the patient site, since the need for hand-eye coordination and the ability to reconstruct a 3-D mental image from 2-D scans, which is a necessity for high quality ultrasound imaging, is eliminated. This could enable relatively untrained medical workers in developing nations to administer imaging and a more accurate diagnosis, effectively saving the lives of people.  相似文献   

2.
Three-dimensional (3-D) reconstructions, by electron microscope tomography, of selectively stained, contrast enhanced Balbiani Ring (BR) hnRNP granules reveal a complex spatial arrangement of RNA-rich domains. This particulate substructure was examined by volume rendering computer graphics. Modeling the arrangement of RNA-rich domains is made difficult by apparent structural flexibility and/or heterogeneity of composition. Formulation of a consensus 3-D arrangement of RNA-rich domains will require an expanded data base of reconstructed BR granules and the development of new image manipulation and analysis techniques. This study demonstrates the potential for ultra-structural cell biology of combining several new techniques: selective nucleic acid staining, electron spectroscopic imaging to enhance contrast, electron microscope tomography and volume rendering computer graphics.Abbreviations BR Balbiani Ring - EMT electron microscope tomography - ESI electron spectroscopic imaging - hnRNP heterogeneous nuclear ribonucleoprotein - OA-B osmium ammine-B - kb kilobases by P.B. Moens  相似文献   

3.
Physical phantom models have conventionally been used to determine the accuracy and precision of radiostereometric analysis (RSA) in various orthopaedic applications. Using a phantom model of a fracture of the distal radius it has previously been shown that RSA is a highly accurate and precise method for measuring both translation and rotation in three-dimensions (3-D). The main shortcoming of a physical phantom model is its inability to mimic complex 3-D motion. The goal of this study was to create a realistic computer model for preoperative planning of RSA studies and to test the accuracy of RSA in measuring complex movements in fractures of the distal radius using this new model. The 3-D computer model was created from a set of tomographic scans. The simulation of the radiographic imaging was performed using ray-tracing software (POV-Ray). RSA measurements were performed according to standard protocol. Using a two-part fracture model (AO/ASIF type A2), it was found that for simple movements in one axis, translations in the range of 25microm-2mm could be measured with an accuracy of +/-2microm. Rotations ranging from 16 degrees to 2 degrees could be measured with an accuracy of +/-0.015 degrees . Using a three-part fracture model the corresponding values of accuracy were found to be +/-4microm and +/-0.031 degrees for translation and rotation, respectively. For complex 3-D motion in a three-part fracture model (AO/ASIF type C1) the accuracy was +/-6microm for translation and +/-0.120 degrees for rotation. The use of 3-D computer modelling can provide a method for preoperative planning of RSA studies in complex fractures of the distal radius and in other clinical situations in which the RSA method is applicable.  相似文献   

4.
Access to structural information at the nanoscale enables fundamental insights into many complex biological systems. The development of the transmission electron microscope (TEM) has vastly increased our understanding of multiple biological systems. However, when attempting to visualize and understand the organizational and functional complexities that are typical of cells and tissues, the standard 2-D analyses that TEM affords often fall short. In recent years, high-resolution electron tomography methods, coupled with advances in specimen preparation and instrumentation and computational speed, have resulted in a revolution in the biological sciences. Electron tomography is analogous to medical computerized axial tomography (CAT-scan imaging) except at a far finer scale. It utilizes the TEM to assemble multiple projections of an object which are then combined for 3-D analyses. For biological specimens, tomography enables the highest 3-D resolution (5 nm spatial resolution) of internal structures in relatively thick slices of material (0.2-0.4 microm) without requiring the collection and alignment of large numbers of thin serial sections. Thus accurate and revealing 3-D reconstructions of complex cytoplasmic entities and architecture can be obtained. Electron tomography is now being applied to a variety of biological questions with great success. This review gives a brief introduction into cryopreservation and electron tomography relative to aspects of cytoplasmic organization in the hyphal tip of Aspergillus nidulans.  相似文献   

5.
Microscopic analysis of tumor vasculature plays an important role in understanding the progression and malignancy of colorectal carcinoma. However, due to the geometry of blood vessels and their connections, standard microtome-based histology is limited in providing the spatial information of the vascular network with a 3-dimensional (3-D) continuum. To facilitate 3-D tissue analysis, we prepared transparent human colorectal biopsies by optical clearing for in-depth confocal microscopy with CD34 immunohistochemistry. Full-depth colons were obtained from colectomies performed for colorectal carcinoma. Specimens were prepared away from (control) and at the tumor site. Taking advantage of the transparent specimens, we acquired anatomic information up to 200 μm in depth for qualitative and quantitative analyses of the vasculature. Examples are given to illustrate: (1) the association between the tumor microstructure and vasculature in space, including the perivascular cuffs of tumor outgrowth, and (2) the difference between the 2-D and 3-D quantitation of microvessels. We also demonstrate that the optically cleared mucosa can be retrieved after 3-D microscopy to perform the standard microtome-based histology (H&E staining and immunohistochemistry) for systematic integration of the two tissue imaging methods. Overall, we established a new tumor histological approach to integrate 3-D imaging, illustration, and quantitation of human colonic microvessels in normal and cancerous specimens. This approach has significant promise to work with the standard histology to better characterize the tumor microenvironment in colorectal carcinoma.  相似文献   

6.
In situ, cells of the musculoskeletal system reside within complex and often interconnected 3-D environments. Key to better understanding how 3-D tissue and cellular environments regulate musculoskeletal physiology, homeostasis, and health is the use of robust methodologies for directly visualizing cell-cell and cell-matrix architecture in situ. However, the use of standard optical imaging techniques is often of limited utility in deep imaging of intact musculoskeletal tissues due to the highly scattering nature of biological tissues. Drawing inspiration from recent developments in the deep-tissue imaging field, we describe the application of immersion based optical clearing techniques, which utilize the principle of refractive index (RI) matching between the clearing/mounting media and tissue under observation, to improve the deep, in situ imaging of musculoskeletal tissues. To date, few optical clearing techniques have been applied specifically to musculoskeletal tissues, and a systematic comparison of the clearing ability of optical clearing agents in musculoskeletal tissues has yet to be fully demonstrated. In this study we tested the ability of eight different aqueous and non-aqueous clearing agents, with RIs ranging from 1.45 to 1.56, to optically clear murine knee joints and cortical bone. We demonstrated and quantified the ability of these optical clearing agents to clear musculoskeletal tissues and improve both macro- and micro-scale imaging of musculoskeletal tissue across several imaging modalities (stereomicroscopy, spectroscopy, and one-, and two-photon confocal microscopy) and investigational techniques (dynamic bone labeling and en bloc tissue staining). Based upon these findings we believe that optical clearing, in combination with advanced imaging techniques, has the potential to complement classical musculoskeletal analysis techniques; opening the door for improved in situ investigation and quantification of musculoskeletal tissues.  相似文献   

7.
The manner in which the nervous system regulates animal behaviors in natural environments is a fundamental issue in biology. To address this question, C. elegans has been widely used as a model animal for the analysis of various animal behaviors. Previous behavioral assays have been limited to two-dimensional (2-D) environments, confining the worm motion to a planar substrate that does not reflect three-dimensional (3-D) natural environments such as rotting fruits or soil. Here, we develop a 3-D worm tracker (3DWT) for freely moving C. elegans in 3-D environments, based on a stereoscopic configuration. The 3DWT provides us with a quantitative trajectory, including the position and movement direction of the worm in 3-D. The 3DWT is also capable of recording and visualizing postures of the moving worm in 3-D, which are more complex than those in 2-D. Our 3DWT affords new opportunities for understanding the nervous system function that regulates animal behaviors in natural 3-D environments.  相似文献   

8.
3-D ultrasound imaging offers unique opportunities in the field of non destructive testing that cannot be easily found in A-mode and B-mode images. To acquire a 3-D ultrasound image without a mechanically moving transducer, a 2-D array can be used. The row column technique is preferred over a fully addressed 2-D array as it requires a significantly lower number of interconnections. Recent advances in 3-D row-column ultrasound imaging systems were largely focused on sensor design. However, these imaging systems face three intrinsic challenges that cannot be addressed by improving sensor design alone: speckle noise, sparsity of data in the imaged volume, and the spatially dependent point spread function of the imaging system. In this paper, we propose a compensated row-column ultrasound image reconstruction system using Fisher-Tippett multilayered conditional random field model. Tests carried out on both simulated and real row-column ultrasound images show the effectiveness of our proposed system as opposed to other published systems. Visual assessment of the results show our proposed system’s potential at preserving detail and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal to Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.  相似文献   

9.
Body segment parameters (BSP) are essential input for the computations in kinetics of motion applied in the field of biomechanics. These data are usually obtained from population-specific predictive equations which present limitations in being representative of the population under study. More recently, medical imaging techniques have been adopted but are limited to two-dimensional (2-D) measurements or required extensive tomographic images for three-dimensional (3-D) reconstruction. We proposed an in vivo method to measure 3-D BSP using X-ray imaging and 3-D exterior geometry. Criterion values of the BSP were determined using magnetic resonance imaging (MRI) which has previously been validated. Errors for all BSP values were less than 2% when values derived from our method were compared to the criterion values. We found no significant difference between our method and four selected BSP models in both stance and swing phase. Significant phase effects were observed for our method and other BSP models between stance and swing phase. Significant differences (p<0.05) between root mean square error (RMSE) ranged from 0.0177 to 0.0234 and 0.0234 to 0.097 Nm kg?1 for the knee and hip joints, respectively. However, these BSP variations brought about effects on moment output that were less than 0.09 Nm kg?1. Our findings suggest joint kinetic computations during normal gait are relatively insensitive to BSP variations. However, the influence of BSP cannot be undermined in movements that generate higher acceleration at the limbs. Considering the accuracy of our method, it could be used as a novel in vivo method to obtain direct 3-D BSP measurements.  相似文献   

10.
Imaging the myocardial activation sequence is critical for improved diagnosis and treatment of life-threatening cardiac arrhythmias. It is desirable to reveal the underlying cardiac electrical activity throughout the three-dimensional (3-D) myocardium (rather than just the endocardial or epicardial surface) from noninvasive body surface potential measurements. A new 3-D electrocardiographic imaging technique (3-DEIT) based on the boundary element method (BEM) and multiobjective nonlinear optimization has been applied to reconstruct the cardiac activation sequences from body surface potential maps. Ultrafast computerized tomography scanning was performed for subsequent construction of the torso and heart models. Experimental studies were then conducted, during left and right ventricular pacing, in which noninvasive assessment of ventricular activation sequence by means of 3-DEIT was performed simultaneously with 3-D intracardiac mapping (up to 200 intramural sites) using specially designed plunge-needle electrodes in closed-chest rabbits. Estimated activation sequences from 3-DEIT were in good agreement with those constructed from simultaneously recorded intracardiac electrograms in the same animals. Averaged over 100 paced beats (from a total of 10 pacing sites), total activation times were comparable (53.3 +/- 8.1 vs. 49.8 +/- 5.2 ms), the localization error of site of initiation of activation was 5.73 +/- 1.77 mm, and the relative error between the estimated and measured activation sequences was 0.32 +/- 0.06. The present experimental results demonstrate that the 3-D paced ventricular activation sequence can be reconstructed by using noninvasive multisite body surface electrocardiographic measurements and imaging of heart-torso geometry. This new 3-D electrocardiographic imaging modality has the potential to guide catheter-based ablative interventions for the treatment of life-threatening cardiac arrhythmias.  相似文献   

11.

Background

Cone-beam Computed Tomography (CBCT) and stereophotography are two of the latest imaging modalities available for three-dimensional (3-D) visualization of craniofacial structures. However, CBCT provides only limited information on surface texture. This can be overcome by combining the bone images derived from CBCT with 3-D photographs. The objectives of this study were 1) to evaluate the feasibility of integrating 3-D Photos and CBCT images 2) to assess degree of error that may occur during the above processes and 3) to identify facial regions that would be most appropriate for 3-D image registration.

Methodology

CBCT scans and stereophotographic images from 29 patients were used for this study. Two 3-D images corresponding to the skin and bone were extracted from the CBCT data. The 3-D photo was superimposed on the CBCT skin image using relatively immobile areas of the face as a reference. 3-D colour maps were used to assess the accuracy of superimposition were distance differences between the CBCT and 3-D photo were recorded as the signed average and the Root Mean Square (RMS) error.

Principal Findings:

The signed average and RMS of the distance differences between the registered surfaces were −0.018 (±0.129) mm and 0.739 (±0.239) mm respectively. The most errors were found in areas surrounding the lips and the eyes, while minimal errors were noted in the forehead, root of the nose and zygoma.

Conclusions

CBCT and 3-D photographic data can be successfully fused with minimal errors. When compared to RMS, the signed average was found to under-represent the registration error. The virtual 3-D composite craniofacial models permit concurrent assessment of bone and soft tissues during diagnosis and treatment planning.  相似文献   

12.
Embryonic epithelia undergo complex deformations (e.g. bending, twisting, folding, and stretching) to form the primitive organs of the early embryo. Tracking fiducial markers on the surfaces of these cellular sheets is a well-established method for estimating morphogenetic quantities such as growth, contraction, and shear. However, not all surface labeling techniques are readily adaptable to conventional imaging modalities and possess different advantages and limitations. Here, we describe two labeling methods and illustrate the utility of each technique. In the first method, hundreds of fluorescent labels are applied simultaneously to the embryo using magnetic iron particles. These labels are then used to quantity 2-D tissue deformations during morphogenesis. In the second method, polystyrene microspheres are used as contrast agents in non-invasive optical coherence tomography (OCT) imaging to track 3-D tissue deformations. These techniques have been successfully implemented in our lab to study the physical mechanisms of early head fold, heart, and brain development, and should be adaptable to a wide range morphogenetic processes.  相似文献   

13.
In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets were acquired by rotating the vessel in 10° steps (Echo-CT), from which both 3-D geometry and 3-D strain data were obtained. Both geometry and morphology were assessed with micro-CT imaging, identifying calcified and lipid rich regions. US-based and CT-based geometries were matched for comparison and were found to show good agreement, with an average similarity index of 0.71. Realistic pressure–volume relations were found for 6 out of 9 samples. 3-D strain datasets were reconstructed, revealing realistic strain patterns and magnitudes, although the data did suffer from a relatively high variability. The percentage of fat and calcifications (micro-CT) were compared with the median, 75th and 99th percentile strain values (Echo-CT). A moderate trend was observed for 75th and 99th percentile strains, higher strains were found for more lipid rich plaques, where lower strains were found for highly calcified plaques. However, an inverse numerical modeling technique is necessary for proper mechanical characterization the of plaque components, using the geometry, morphology and wall deformation as input.  相似文献   

14.
Two novel structures, {[Pb(3-sb)(4,4′-bipy)0.5](H2O)}n (1) together with the previously reported complex {[Pb(3-sb)(H2O)2](4,4′-bipy)}n (2), where 3-sb is 3-sulfobenzoate dianion and 4,4′-bipy is 4,4′-bipyridine, were synthesized and characterized by IR, elemental analyses, TGA, powder X-ray, fluorescent and single-crystal X-ray analyses. The highly ordered 2-D structure of 2 exists as π–π stacking and hydrogen-bonding interactions, while complex 1 is a 3-D network with 2-D interpenetration layers without π–π and hydrogen-bonding interactions and with abundant secondary bonding interactions. Therefore, complex 1 has thermally more stable structure than that of complex 2, and water molecules can be removed and re-combined in complex 1.  相似文献   

15.
The development of vessel-like structures in vitro to mimic as well as to realize the possibility of tissue-engineered small vascular networks presents a major challenge to cell biologists and biotechnologists. We aimed to establish a three-dimensional (3-D) culture system with an endothelial network that does not require artificial substrates or ECM compounds. By using human skin fibroblasts and endothelial cells (ECs) from the human umbilical vein (HUVECs) in diverse spheroid coculture strategies, we verified that fibroblast support and modulate EC migration, viability, and network formation in a 3-D tissue-like stromal environment. In mixed spheroid cultures consisting of human ECs and fibroblasts, a complex 3-D network with EC tubular structures, lumen formation, pinocytotic activity, and tight junction complexes has been identified on the basis of immunohistochemical and transmission electron microscopic imaging. Tubular networks with extensions up to 400 µm were achieved. When EC suspensions were used, EC migration and network formation were critically affected by the status of the fibroblast. However, the absence of EC migration into the center of 14-day, but not 3-day, precultured fibroblast spheroids could not be attributed to loss of F viability. In parallel, it was also confirmed that migrated ECs that entered cluster-like formations became apoptotic, whereas the majority of those forming vessel-like structures remained viable for >8 days. Our protocols allow us to study the nature of tubule formation in a manner more closely related to the in vivo situation as well as to understand the basis for the integration of capillary networks in tissue grafts and develop methods of quantifying the amount of angiogenesis in spheroids using fibroblast and other cells isolated from the same patient, along with ECs. endothelium; angiogenesis; human umbilical vein endothelial cell; multicellular spheroid; coculture; tubular structures  相似文献   

16.
Cryo-electron tomography (cryo-ET) is an emerging imaging technology that combines the potential of three-dimensional (3-D) imaging at molecular resolution (<5 nm) with a close-to-life preservation of the specimen. In conjunction with pattern recognition techniques, it enables us to map the molecular landscape inside cells. The application of cryo-ET to intact cells provides novel insights into the structure and the spatial organization of the cytoskeleton in prokaryotic and eukaryotic cells.  相似文献   

17.
Cell mechanical behavior has traditionally been studied using 2-D planar elastic substrates. The goal of this study was to directly assess cell-matrix mechanical interactions inside more physiologic 3-D collagen matrices. Rabbit corneal fibroblasts transfected to express GFP-zyxin were plated at low density inside 100 micro m-thick type I collagen matrices. 3-D datasets of isolated cells were acquired at 1-3-min intervals for up to 5 h using fluorescent and Nomarski DIC imaging. Unlike cells on 2-D substrates, cells inside the collagen matrices had a bipolar morphology with thin pseudopodial processes, and without lamellipodia. The organization of the collagen fibrils surrounding each cell was clearly visualized using DIC. Using time-lapse color overlays of GFP and DIC images, displacement and/or realignment of collagen fibrils by focal adhesions could be directly visualized. During pseudopodial extension, new focal adhesions often formed in a line along collagen fibrils in front of the cell, while existing adhesions moved backward. This process generated tractional forces as indicated by the pulling in of collagen fibrils in front of the cell. Meanwhile, adhesions on both the dorsal and ventral surface of the cell body generally moved forward, resulting in contractile shortening along the pseudopodia and localized extracellular matrix (ECM) compression. Cytochalasin D induced rapid disassembly of focal adhesions, cell elongation, and ECM relaxation. This experimental model allows direct, dynamic assessment of cell-matrix interactions inside a 3-D fibrillar ECM. The data suggest that adhesions organize along actin-based contractile elements that are much less complex than the network of actin filaments that mechanically links lamellar adhesions on 2-D substrates.  相似文献   

18.
Cucumber (Cucumis sativus L.) LHC-Ⅱ complex, which consists of only one subunit (27 kD), was isolated and purified. 2-D crystallization was performed by batch method. The crystal is 0.7 μm×1.0 μm, and diffracts to 30 ?. The projection map of the negatively stained two-dimensional crystal of LHC-Ⅱ complex shows that the crystal has p3 symmetry, lattice constant 15.4 nm×15.4 nm, which is different from the LHC-Ⅱ of spinach (Spinacia oleracea L.) and pea (Pisum satium L.). A continuous tomographic tilt series, containing 12 projections from the two-dimensional crystal was subjected to 3-D reconstruction. The 3-D model represents that LHC-Ⅱ complex consists of 6 monomers. These trimer and dimer interactions build up the six member ring.   相似文献   

19.
Bone is a complex, highly structured, mechanically active, three-dimensional (3-D) tissue composed of cellular and matrix elements. We previously published a report on in situ collagen gelation using a rotary 3-D culture system (CG–RC system) for the construction of large tissue specimens. The objective of the current study was to evaluate the feasibility of bone tissue engineering using our CG–RC system. Osteoblasts from the calvaria of newborn Wistar rats were cultured in the CG–RC system for up to 3 wk. The engineered 3-D tissues were implanted into the backs of nude mice and calvarial round bone defects in Wistar rats. Cell metabolic activity, mineralization, and bone-related proteins were measured in vitro in the engineered 3-D tissues. Also, the in vivo histological features of the transplanted, engineered 3-D tissues were evaluated in the animal models. We found that metabolic activity increased in the engineered 3-D tissues during cultivation, and that sufficient mineralization occurred during the 3 wk in the CG–RC system in vitro. One mo posttransplantation, the transplants to nude mice remained mineralized and were well invaded by host vasculature. Of particular interest, 2 mo posttransplantation, the transplants into the calvarial bone defects of rats were replaced by new mature bone. Thus, this study shows that large 3-D osseous tissue could be produced in vitro and that the engineered 3-D tissue had in vivo osteoinductive potential when transplanted into ectopic locations and into bone defects. Therefore, this system should be a useful model for bone tissue engineering.  相似文献   

20.
Recent advances in imaging have led to high-resolution computerized tomography (CT) scanning with exquisitely detailed slice images of the skull and three-dimensional (3-D) surface reconstructions using computer software. It is possible to use CT scans to acquire morphologic information about the skull in a convenient digital form and to derive 3-D measurements from surface reconstruction images. Unfortunately, no effort has been made to date to test the validity of these measurements on laboratory specimens, and no compelling evidence is available from phantom studies to indicate the nature and magnitude of the errors inherent in the measurement technique. We have performed a pilot study to quantify the morphology of the skull based on surface features that can be found in CT scans and 3-D reconstructions. Comparative measurements were obtained from five skulls (two normal and three with dysmorphology) with calipers and a 3-D electromagnetic digitizer. These measurements were statistically compared with those based on original CT scan slices and reformatted 3-D images. It is concluded that 3D-CT measurement techniques are superior to those in which measurements are obtained directly from the original CT slices; 3-D CT methods, however, must be significantly improved before measurements based on these techniques can be used in studies that require a high degree of precision. The results are used to indicate the most fruitful areas of future study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号