首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new electrochemical method to monitor biotin-streptavidin interaction, based on the use of colloidal gold as an electrochemical label, is investigated. Biotinylated albumin is adsorbed on the pretreated surface of a carbon paste electrode (CPE). This modified electrode is immersed in colloidal gold-streptavidin labelled solutions. Adsorptive voltammetry is used to monitor colloidal gold bound to streptavidin, obtaining a good reproducibility of the analytical signal (R.S.D. = 3.3%). A linear relationship between peak current and streptavidin concentration from 2.5 x 10(-9) to 2.5 x 10(-5) M is obtained when a sequential competitive assay between streptavidin and colloidal gold-labelled streptavidin is carried out. On the other hand, the adsorption of streptavidin on the electrode surface was performed, followed by the reaction with biotinylated albumin labelled with colloidal gold. In this way, a linear relationship between peak current and colloidal gold labelled biotinylated albumin concentration is achieved with a limit of detection of 7.3 x 10(9) gold particles per ml (5.29 x 10(-9) M in biotin).  相似文献   

2.
A new electrochemical method to monitor biotin-streptavidin interaction on carbon paste electrode, based on silver electrodeposition catalyzed by colloidal gold, was investigated. Silver reduction potential changed when colloidal gold was attached to an electrode surface through the biotin-streptavidin interaction. Thus, the direct reduction of silver ions on the electrode surface could be avoided and therefore, they were only reduced to metallic silver on the colloidal gold particle surface, forming a shell around these particles. When an anodic scan was performed, this shell of silver was oxidized and an oxidation process at + 0.08 V was recorded in NH3 1.0 M. Biotinylated albumin was adsorbed on the pretreated electrode surface. This modified electrode was immersed in colloidal gold-streptavidin labeled solutions. The carbon paste electrode was then activated in adequate medium (NaOH 0.1 M and H2SO4 0.1 M) to remove proteins from the electrode surface while colloidal gold particles remained adsorbed on it. Then, a silver electrodeposition at -0.18 V for 2 min and anodic stripping voltammetry were carried out in NH3 1.0 M containing 2.0 x 10(-5) M of silver lactate. An electrode surface preparation was carried out to obtain a good reproducibility of the analytical signal (5.3%), using a new electrode for each experiment. In addition, a sequential competitive assay was carried out to determine streptavidin. A linear relationship between peak current and logarithm of streptavidin concentration from 2.25 x 10(-15) to 2.24 x 10(-12) M and a limit of detection of 2.0 x 10(15) M were obtained.  相似文献   

3.
A new active support for electro-chemiluminescent biochip preparation has been developed. This material was based on an original material composed of graphite modified polydimethyl siloxane (PDMS). The addressed inclusion of Sepharose beads at the surface of this elastomeric electrode generated interesting local high specific surface. The electrode was characterised by electrochemical (cyclic voltametry, chronoamperomatry) and imaging (scanning electron microscopy (SEM)) methods, and a surface area increase factor of 50 was found, linked to the texturing of the surface generated by the presence of the Sepharose beads. The consequence of this increase was shown to be a jump of the local electrochemical activity which induced a well defined and localised electro-chemiluminescent signal. The new material was used to design biochips based on the electro-chemiluminescent reaction of luminol with enzymatically produced hydrogen peroxide. Thus, when using beads bearing bio-molecules such nucleic acid or human IgG, in conjunction with glucose oxidas-labelled DNA or antibody, sensitive biochips could be obtained with detection limits of 10(11) and 10(10) molecules, respectively. Multi-parameter enzyme-based biochips could also be achieved by locally adsorbing, at the PDMS-graphite surface, either glucose oxidase, lactate oxidase or choline oxidase. Detection limits of 10 microM for lactate and choline and 20 microM for glucose were found, with detection ranging over two decades at least.  相似文献   

4.
We have developed a simple and renewable electrochemical biosensor based on carbon paste electrode (CPE) for the detection of DNA synthesis and hybridization. CPE was modified with gold nanoparticles (AuNPs), which are helpful for immobilization of thiolated bioreceptors. AuNPs were characterized by scanning electron microscopy (SEM). Self-assembled monolayers (SAMs) of thiolated single-stranded DNA (SH–ssDNA) of the amelogenin gene was formed on CPE. The immobilization of the probe and its hybridization with the target DNA was optimized using different experimental conditions. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The electrochemical response of ssDNA hybridization and DNA synthesis was measured using differential pulse voltammetry (DPV) with methylene blue (MB) as an electroactive indicator. The new biosensor can distinguish between complementary and non-complementary strands of amelogenin ssDNA. Genomic DNA was extracted from blood and was detected based on changes in the MB reduction signal. These results demonstrated that the new biosensor could be used for sex determination. The proposed biosensor in this study could be used for detection and discrimination of polymerase chain reaction (PCR) products of amelogenin DNA.  相似文献   

5.
A new electrochemical method to monitor biotin–streptavidin interaction on carbon paste electrode, based on silver electrodeposition catalyzed by colloidal gold, was investigated. Silver reduction potential changed when colloidal gold was attached to an electrode surface through the biotin–streptavidin interaction. Thus, the direct reduction of silver ions on the electrode surface could be avoided and therefore, they were only reduced to metallic silver on the colloidal gold particle surface, forming a shell around these particles. When an anodic scan was performed, this shell of silver was oxidized and an oxidation process at +0.08 V was recorded in NH3 1.0 M. Biotinylated albumin was adsorbed on the pretreated electrode surface. This modified electrode was immersed in colloidal gold-streptavidin labeled solutions. The carbon paste electrode was then activated in adequate medium (NaOH 0.1 M and H2SO4 0.1 M) to remove proteins from the electrode surface while colloidal gold particles remained adsorbed on it. Then, a silver electrodeposition at −0.18 V for 2 min and anodic stripping voltammetry were carried out in NH3 1.0 M containing 2.0×10−5 M of silver lactate. An electrode surface preparation was carried out to obtain a good reproducibility of the analytical signal (5.3%), using a new electrode for each experiment. In addition, a sequential competitive assay was carried out to determine streptavidin. A linear relationship between peak current and logarithm of streptavidin concentration from 2.25×10−15 to 2.24×10−12 M and a limit of detection of 2.0×10−15 M were obtained.  相似文献   

6.
A new highly sensitive amperometric method for the detection of organophosphorus compounds has been developed. The method is based on a ferophthalocyanine chemically modified carbon paste electrode coupled with acetylcholinesterase and choline oxidase co-immobilized onto the surface of a dialysis membrane. The activity of cholinesterase is non-competitively inhibited in the presence of pesticides. The highest sensitivity to inhibitors was found for a membrane containing low enzyme loading and this was subsequently used for the construction of an amperometric biosensor for pesticides. Analyses were done using acetylcholine as substrate; choline produced by hydrolysis in the enzymatic layer was oxidized by choline-oxidase and subsequently H(2)O(2) produced was electrochemically detected at +0.35 V vs. Ag/AgCl. The decrease of substrate steady-state current caused by the addition of pesticide was used for evaluation. With this approach, up to 10(-10) M of paraoxon and carbofuran can be detected.  相似文献   

7.
A new approach toward the development of advanced immunosensors based on chemically functionalized core-shell-shell magnetic nanocomposite particles, and the preparation, characteristics, and measurement of relevant properties of the immunosensor useful for the detection of alpha-1-fetoprotein (AFP) in clinical immunoassays. The core-shell NiFe2O4/3-aminopropyltriethoxysilance (APTES) (NiFe2O4@APTES) was initially prepared by covalent conjugation, then gold nanoparticles were adsorbed onto the surface of NiFe2O4@APTES, and then anti-AFP molecules were conjugated on the gold nanoparticles. The core-shell-shell nanocomposite particles not only had the properties of magnetic nanoparticles, but also provided a good biocompatibility for the immobilization of biomolecules. The core-shell-shell nanostructure present good magnetic properties to facilitate and modulate the way it was integrated into a carbon paste. The analytical performance of the immunosensor was investigated by using an electrochemical method. Under optimal conditions, the resulting composite presents good electrochemical response for the detection of AFP, and exhibits wide linear range from 0.9 to 110 ng/mL AFP with a detection limit of 0.5 ng/mL. Moreover, the proposed immunosensors were used to analyze AFP in human serum specimens. Analytical results, obtained for the clinical serum specimen by the developed immunosensor, were in accordance with those assayed by the standard ELISA. Importantly, the proposed immunoassay system could be further developed for the immobilization of other antigens or biocompounds.  相似文献   

8.
A new electrochemical sensor for the determination of norepinephrine (NE), acetaminophen (AC) and tryptophan (Trp) is described. The sensor is based on carbon paste electrode (CPE) modified with 3,4-dihydroxybenzaldehyde-2,4-dinitrophenylhydrazone (DDP) and takes the advantages of carbon nanotubes (CNTs), which makes the modified electrode highly sensitive for the electrochemical detection of these compounds. Cyclic voltammetry (CV) at various scan rates was used to investigate the redox properties of the modified electrode. The apparent charge transfer rate constant, k(s), and transfer coefficient, α, for electron transfer between DDP and CNT paste electrode were calculated. The mediated oxidation of NE at the modified electrode was investigated by CV and the values of k, α and diffusion coefficient (D) were calculated. Under the optimum pH of 7.0, the oxidation of NE occurs at a potential about 215 mV less positive than that of the unmodified CPE. Differential pulse voltammetry (DPV) of NE at the modified electrode exhibited two linear dynamic ranges with a detection limit (3σ) of 77±2 nM. DPV was used for simultaneous determination of NE, AC and Trp at the modified electrode, and quantitation of NE in some real samples by the standard addition method.  相似文献   

9.
In this article, a composite paste electrode consisted of multiwall carbon nanotube (MWCNT) and room temperature ionic liquids (RTILs) was developed for fabrication of electrochemiluminescence (ECL) sensor. The electrochemical and ECL behaviors of this sensor were investigated in detail. This ECL sensor exhibited extraordinary stability during long-term potential cycling. It was found that the light emission of this ECL sensor could be enhanced by methamphetamine hydrochloride (MA.HCl) dramatically. Based on which, a new method based on this ECL sensor has been developed for determination of MA.HCl. The method exhibited a good reproducibility, wide-range linearity, high sensitivity and stability with a detection limit (signal-to-noise ratio=3) of 8.0 x 10(-9)mol/L, and the relative standard deviation was 3.1% for 1 x 10(-5)mol/L MA.HCl (n=10).  相似文献   

10.
A hydroquinone biosensor was developed and used to determine hydroquinone concentration in compost extracts based on the immobilization of laccase on the surface of modified magnetic core-shell (Fe(3)O(4)-SiO2) nanoparticles. Laccase was covalently immobilized on the magnetic nanoparticles by glutaraldehyde, which was modified with amino groups on its surface. The obtained magnetic bio-nanoparticles were attached to the surface of carbon paste electrode with the aid of a permanent magnet to determine hydroquinone. A good microenvironment for retaining the bioactivity of laccase was provided by the immobilization matrix. The linear range for hydroquinone determination was 1 x 10(-7) to 1.375 x 10(-4)M, with a detection limit of 1.5 x 10(-8)M. The current reached 95% of the steady-state current within about 60s. Hydroquinone concentration in compost extracts was determined by laccase biosensor and HPLC, the results of the two methods were approximately the same.  相似文献   

11.
A carbon paste electrode modified with the adsorbed products of the electrochemical oxidation of adenosine triphosphate is described. The electrode was applied to the amperometric electrocatalytic detection of the reduced form of both nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate. The catalytic oxidation current shows a linear dependence on the concentration of the reduced form of nicotinamide adenine dinucleotide up to 1x10(-4)M, with a detection limit of 5x10(-9)M. Modified carbon paste electrodes were coated with an electrogenerated film of nonconducting poly(o-phenylenediamine) to obtain a stable amperometric response for at least 150h. In addition to static measurements, determination of both reduced cofactors was carried out in a flow injection analysis system with a thin-layer amperometric detection cell. The electrocatalytic monitoring of reduced nicotinamide adenine dinucleotide phosphate was applied to flow injection measurement of isocitrate dehydrogenase activity in serum. The results were in good agreement with those for the standard spectrophotometric test kit. The proposed method consumed less time and reagents and provided better precision than the standard method.  相似文献   

12.
The development of electrochemical biosensors using dehydrogenases associated with the corresponding cofactor is strongly related to the better understanding of NADH oxidation at the electrode surface. The aim is to lower the necessary overvoltage and consequently to escape interferences and electrode fouling. In this paper, we show that carbon paste electrode (CPE) modified with NaY zeolite fulfils this requirements thanks to its hydrophilic surface. Oxidation of NADH at ferrocene (FcH) modified carbon paste electrode exhibits a rather slow electrocatalytic effect. We demonstrated the existence of synergetic effect on the electrocatalytic oxidation of NADH when the CPE is doped with zeolite (NaY) and FcH mediator or with the zeolite exchanged beforehand with the mediator (Y-Ferricinium, YFcH). This cumulative effect permits to reach high sensitivity for NADH detection and offers new way for the development of enzymatic biosensors using dehydrogenases depending on NADH as cofactor.  相似文献   

13.
The electrochemical performance of a new glucose biosensor is reported. The glucose biosensor is developed using glucose oxidase (GOD) and ferrocene encapsulated palladium (Pd)-linked organically modified sol-gel glass (ORMOSIL) material incorporated within graphite paste electrode. The ORMOSIL material incorporated within graphite paste electrode behaves as an excellent electrocatalyst for the oxidation of enzymatically reduced GOD. The electrochemical behavior of new glucose biosensor has been examined by cyclic volammetry and amperometric measurements. The bioelectrocatalysis of ORMOSIL embedded within graphite paste as a function of storage time and varying concentration of ORMOSIL is reported. The initial amperometric response on glucose sensing is recorded to be 145 microA at 15% (w/w) concentration of the ORMOSIL which is decreased to 20 microA at 5% of the same keeping GOD concentration constant. The variation of electrochemical behavior of the ORMOSIL embedded within graphite paste as a function of time has also been studied based on cyclic voltammetry. The voltammograms showing the reversible electrochemistry of ORMOSIL encapsulated ferrocene is changed into a plateau shape as a function of time, however, the electrocatalytic behavior is still retained. The practical usability of new glucose sensor has been compared with earlier developed glucose sensor. The sensitivity, response time and linearity of the new glucose biosensor are found to be excellent over earlier reported glucose biosensor. The amperometric response, calibration curve and practical applications of new glucose sensor are reported.  相似文献   

14.
Different tyrosinase carbon paste modified electrodes to determine bisphenol A (BPA) concentration in aqueous solutions have been constructed. Variables examined were in the carbon paste composition and in particular: (i) the immobilized enzyme amount; (ii) the carbon type (powder, single or multi-walled nanotubes); (iii) the nature of the pasting oil (mineral oil, hexadecane and dodecane). For each biosensor type the amperometric response was evaluated with reference to the linear range and sensitivity. Constant reference has been made to the amperometric signals obtained, under the same experimental conditions, towards the catechol, a specific phenolic substrate for tyrosinase. The most efficient biosensors were those constructed by using the following composition for the carbon paste: 10% of tyrosinase, 45% of single wall carbon nanotubes (SWCN) and 45% of mineral oil. This biosensor formulation displayed the following electrochemical characteristics: a sensitivity equal to 138 microA/mM, LOD of 0.02 microM (based on three times the S/N ratio), linear range of 0.1-12 microM and response time of 6 min. This experimental work represents a first attempt at construction of a new carbon nanotube-tyrosinase based biosensor able to determine the concentration of BPA, one of the most ubiquitous and hazardous endocrine disruptors which can pollute the drinking and surface water, as well as many products of the food chain.  相似文献   

15.
A potentiometric, enantioselective membrane electrode based on graphite paste (graphite powder and paraffin oil) has been constructed. The graphite paste is impregnated with a 10−3 mol/L 2‐hydroxy‐3‐trimethylammoniopropyl‐β‐cyclodextrin (as chloride salt) solution. The potentiometric, enantioselective membrane electrode can be used reliably for enantiopurity tests of S‐perindopril using a chronopotentiometric (zero current) technique, in the 10−5–10−2 mol/L concentration range (detection limit 5 × 10−6 mol/L), with an average recovery of 99.58% (RSD = 0.33%). The enantioselectivity was determined over R‐perindopril and d ‐proline. The response characteristics of the enantioselective, potentiometric membrane electrode were also determined for R‐perindopril. It was shown that l ‐proline is the main interfering compound. The surface of the electrode can be regenerated simply by polishing, obtaining a fresh surface ready to be used in a new assay. Chirality 11:631–634, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

16.
In this study, electrical impedimetric biosensors composed of Au-electrodes were fabricated for the quantitative detection of human serum albumin (HSA), an essential biomarker of liver function. The Au-electrodes were fabricated via a single-step photolithography process, and can be easily integrated in biochips for assessing liver function in the future. The glass sensing surface between two adjacent Au-electrodes was modified with 3-aminopropyltriethoxysilane (APTES) to improve the biocompatibility for its subsequent binding to anti-human serum albumin (AHSA). The sensing surface without AHSA binding was blocked using skim milk powders, preventing possible non-specific bonding HSA conjugation. Biosensors were used to measure HSA concentration for liver function detection. The impedance between two adjacent Au-electrodes of the biosensors applied with various HSA concentrations was directly measured, and quantified using an electrochemical impedance spectroscopy system under AC conditions. The results of plotting both values in log scales indicated the impedance increased linearly with HSA conjugation increase. The limit of HSA detection was about 2'10(-4)mg/ml using the electrochemical impedimetric biosensor proposed in this work. This study demonstrates the feasibility of using electrochemical impedimetry as a bio-sensing mechanism to quantify human serum albumin concentration. The sensor proposed in this work also displays great potential for assessing liver function because of its simple detection mechanism, ease of biochip integration, and low cost.  相似文献   

17.
In this study, a novel DNA electrochemical probe (locked nucleic acid, LNA) was designed and involved in constructing an electrochemical DNA biosensor for detection of promyelocytic leukemia/retinoic acid receptor alpha (PML/RARα) fusion gene in acute promyelocytic leukemia for the first time. This biosensor was based on a 'sandwich' sensing mode, which involved a pair of LNA probes (capture probe immobilized at electrode surface and biotinyl reporter probe as an affinity tag for streptavidin-horseradish peroxidase (streptavidin-HRP). Since biotin can be connected with streptavidin-HRP, this biosensor offered an enzymatically amplified electrochemical current signal for the detection of target DNA. In the simple hybridization system, DNA fragment with its complementary DNA fragment was evidenced by amperometric detection, with a detection limit of 74 fM and a linear response range of 0.1-10 pM for synthetic PML/RARα fusion gene in acute promyelocytic leukemia (APL). Otherwise, the biosensor showed an excellent specificity to distinguish the complementary sequence and different mismatch sequences. The new pattern also exhibited high sensitivity and selectivity in mixed hybridization system.  相似文献   

18.
A novel composite of graphene sheets/Congo red-molecular imprinted polymers (GSCR-MIPs) was synthesized through free radical polymerization (FRP) and applied as a molecular recognition element to construct dopamine (DA) electrochemical sensor. The template molecules (DA) were firstly absorbed at the GSCR surface due to their excellent affinity, and subsequently, selective copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) was further achieved at the GSCR surface. Potential scanning was presented to extract DA molecules from the imprinted polymers film, and as a result, DA could be rapidly and completely removed by this way. With regard to the traditional MIPs, the GSCR-MIPs not only possessed a faster desorption and adsorption dynamics, but also exhibited a higher selectivity and binding capacity toward DA molecule. As a consequence, an electrochemical sensor for highly sensitive and selective detection of DA was successfully constructed as demonstration based on the synthesized GSCR-MIPs nanocomposites. Under experimental conditions, selective detection of DA in a linear concentration range of 1.0 × 10(-7)-8.3 × 10(-4)M was obtained, which revealed a lower limit of detection and wider linear response compared to some previously reported DA electrochemical MIPs sensors. The new DA electrochemical sensor based on GSCR-MIPs composites also exhibited excellent repeatability, which expressed as relative standard deviation (RSD) was about 2.50% for 30 repeated analyses of 20 μM DA.  相似文献   

19.
Since the electrochemical oxidation peaks of both DNA and anti-tumor drug tamoxifen (TAM) overlapped with each other, the known electrochemical methods were limited in the study of the interactions between DNA and TAM. In this paper, zero current potentiometry, a new electrochemical method, was used to study the interaction of calf thymus dsDNA with TAM. The dsDNA was immobilized on the surface of carbon paste (dsDNA/CP). The dsDNA/CP connected in series between the clips of working and counter electrodes of a potentiostat and a reference electrode were immersed in aqueous solution containing TAM, the interaction of dsDNA with TAM produced a change in interfacial potential at the dsDNA/CP/solution interface. When linear sweep potential was applied to the dsDNA/CP and the corresponding I-E curve was recorded, interfacial potential offset applied potential partially, making the I-E curve displace along potential axis. Zero current potential where circuit current I was equal to zero in the I-E curve was measured to check the displacement of the I-E curve. Based on the displacement, the thermodynamic constants of the interaction between dsDNA and TAM were determined. The binding ratio of dsDNA with TAM was found to be 1:1 and the apparent binding constant was (6.85±0.20)×10(6) M(-1). As zero current potentiometry was independent of the changes in redox potential or current of both dsDNA and TAM themselves, the interaction was studied in their natural forms without damage. Moreover, TAM can be determined. The detection limit was 1.1×10(-7) M.  相似文献   

20.
A three dimensional (3D) gold (Au) nanodendrite network porous structure constructed by a simple electrochemical synthetic method has been presented, and its utility for sensitive electrochemical measurement was demonstrated in this study. The 3D nanodendrite network porous structure was constructed on a platinum surface through electrodeposition of Au under the presence of hydrogen bubbles generated from the same surface. Iodide, used as a co-reagent, played an important role in the construction of the nanodendrite network by preventing continual growth of Au into larger agglomerates as well as inhibiting coalescence of neighboring nanodendrites. An electrochemical sensor incorporating the structure was built and used to detect As(III) in ultra low concentration range. For the purpose of comparison, bare gold and gold nanoparticle-incorporated electrodes were also prepared. With the use of 3D nanodendrite network porous structure, a much more sensitive detection of As(III) was possible due to its large surface area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号