首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The adsorption characteristics of various filter media and treatment efficiency of small pilot-scale constructed wetlands (CWs) were investigated in order to design optimum CWs for treating greenhouse wastewater. Calcite was the best filter medium for the adsorption of ammonium nitrogen and phosphorus under various temperature and pH conditions. However, removal efficiency of calcite for total nitrogen (T-N) removal was low due primarily to high nitrate levels. Thus, several hybrid CWs (containing calcite as filter media) consisting of combinations of vertical flow (VF) and horizontal flow (HF) beds were evaluated for improving efficiency for T-N removal. Both 2- and 3-stage combinations of the VF and HF beds were tested. The optimum hybrid CWs was demonstrated to be a 3-stage combination of horizontal flow (HF)–vertical flow (VF)–horizontal flow (HF), which provided suitable conditions for both nitrification and denitrification, which improved removal of T-N in wastewater containing nitrate. In the HF–VF–HF 3-stage hybrid CWs, the reduction in chemical oxygen demand (COD), T-N, and total phosphorus (T-P) in the effluent were 95.1, 68.4 and 94.3%, respectively. The removal of COD, T-N and T-P in 3-stage HF–VF–HF CWs was rapid in order of VF (second stage)  HF (first stage)  HF (third stage), VF (second stage)  HF (third stage) > HF (first stage) and VF (second stage)  HF (first stage)  HF (third stage), respectively.  相似文献   

2.
《Ecological Engineering》2005,24(3):185-198
In 2001, to foster the practical development of constructed wetlands (CWs) used for domestic wastewater treatment in Turkey, vertical subsurface flow constructed wetlands (30 m2 of each) were implemented on the campus of the METU, Ankara, Turkey. The main objective of the research was to quantify the effect of different filter media on the treatment performance of vertical flow wetlands in the prevailing climate of Ankara. Thus, a gravel-filled wetland and a blast furnace granulated iron slag-filled wetland were operated identically with primarily treated domestic wastewater (3 m3 d−1) at a hydraulic loading rate of 0.100 m d−1, intermittently. Both of the wetland cells were planted with Phragmites australis. According to the first year results, average removal efficiencies for the slag and gravel wetland cells were as follows: total suspended solids (TSS) (63% and 59%), chemical oxygen demand (COD) (47% and 44%), NH4+–N (88% and 53%), total nitrogen (TN) (44% and 39%), PO43−-P (44% and 1%) and total phosphorus (TP) (45% and 4%). The treatment performances of the slag-filled wetland were better than that of the gravel-filled wetland in terms of removal of phosphorus and production of nitrate. Since this study was a pioneer for implementation of subsurface constructed wetlands in Turkey using local sources, it has proved that this eco-technology could also be used effectively for water quality enhancement in Turkey.  相似文献   

3.
A horizontal subsurface flow (HSSF) and a free water surface flow (FWSF) constructed wetlands (4 m2 of each) were set up on the campus of Harran University, Sanliurfa, Turkey. The main objective of the research was to compare the performance of two systems to decide the better one for future planning of wastewater treatment system on the campus. Both of the wetland systems were planted with Phragmites australis and Canna indica. During the observation period (10 months), environmental conditions such as pH, temperature and total chemical oxygen demand (COD), soluble COD, total biochemical oxygen demand (BOD), soluble BOD, total suspended solids (TSS), total phosphate (TP), total nitrogen (TN) removal efficiencies of the systems were determined. According to the results, average yearly removal efficiencies for the HSSF and the FWSF, respectively, were as follows: total COD (75.7% and 69.9%), soluble COD (85.4% and 84.3%), total BOD (79.6% and 87.6%), soluble BOD (87.7% and 95.3%), TN (33.2% and 39.4%), and TP (31.5% and 6.5%). Soluble COD and BOD removal efficiencies of both systems increased gradually since the start-up. After nine months of operation, above 90% removal of organic matters were observed. The treatment performances of the HSSF were better than that of the FWSF with regard to the removal of suspended solids and total COD at especially high temperatures. In FWSF systems, COD concentrations extremely exceeded the discharge limit values due to high concentrations of algae in spring months.The performance of the two systems was modelled using an artificial neural network-back-propagation algorithm. The ANN model was competent at providing reasonable match between the measured and the predicted concentrations of total COD (R = 0.90 for HSSF and R = 0.96 for FWSF), soluble COD (R = 0.90 for HSSF and R = 0.74 for FWSF) and total BOD (R = 0.94 for HSSF and R = 0.84 for FWSF) in the effluents of constructed wetlands.  相似文献   

4.
Uptake and release of nutrients from ponds used for lotus cultivation were measured in ponds under short-term (1 yr) cultivation with compost application (pond I) and under long-term (20 yr) cultivation without compost application (pond II). Total inflow loads of TN (irrigation water, rainfall and compost) during lotus cultivation period in ponds I and II were 72.3 and 34.3 kg ha?1 182 day?1, respectively. TN removal rates in ponds I and II were 77.3 and 49.8% of total inflow load, respectively. Major removal mechanisms of TN were attributed to microbial processes and uptake by lotus. The total outflow loads (infiltration and runoff) of TN during the lotus cultivation period were 13.9 kg ha?1 182 day?1 (19.2% of total inflow TN load) for pond I, and 11.3 kg ha?1 182 day?1 (32.9% of total inflow TN load) for pond II. For TP the total inflow loads (irrigation water, rainfall and compost) during lotus cultivation in ponds I and II were 80.8 and 1.9 kg ha?1 182 day?1, respectively. TP removal rates in ponds I and II were 84.9 and ?274.1% of total input, respectively. Phosphorus removal was attributed to lotus uptake and soil adsorption. The total outflow loads (infiltration and runoff) of TP during lotus cultivation period were 10.1 kg ha?1 182 day?1 (12.5% of total inflow TP load) for pond I, and 6.6 kg ha?1 182 day?1 (355.6% of total inflow TP load) for pond II. TN and TP in runoff from pond I (with compost) was higher than that in pond II (without compost), showing that TN and TP in runoff were strongly influenced by compost addition. Therefore, in order to satisfy established water-quality standards, the amount of compost used in lotus cultivation should be evaluated.  相似文献   

5.
The effects of wastewater loading rates and two macrophyte species on treatment of sugar factory stabilization pond effluent were investigated in a pilot-scale free water surface constructed wetland (FWS CW) system in western Kenya. For 12 months, four CWs were operated at a hydraulic loading rate of 75 mm day−1 and four at 225 mm day−1. Half the CWs were planted with Cyperus papyrus and half with Echinochloa pyramidalis. Water samples were taken at the inlets and outlets and analyzed for TP, TDP, NH4-N, and TSS. Mass removal rates of the selected water quality parameters were compared during three periods designated the short rain (period 1), dry (period 2), and long rain (period 3) seasons. There was a significant linear relationship between the mass removal rate of TP, NH4-N, and TSS and the mass load, and season had a significant effect on the mass removal rate of TSS, NH4-N, and TDP. Mass loading rates for TDP were about 78% of those for TP, whereas TDP comprised 78–99% of TP mass outflow rates, indicating a release of dissolved P within the CWs. The only significant difference between the two macrophyte species was associated with mass removal of NH4-N, with more efficient removal in CWs planted with C. papyrus than those with E. pyramidalis. TP mass removal rates were 50–80% higher when a mean water loss for CWs 6–8 during periods 1 and 2 was assumed to represent evapotranspiration for all CWs in period 3 instead of pan evaporation data. This illustrated the importance of accurate estimations of evapotranspiration for pollutant mass removal rates in CWs in tropical climates.  相似文献   

6.
Constructed wetlands are becoming increasingly popular worldwide for removing contaminants from domestic wastewater. This study investigated the removal efficiency of nitrogen (N) and phosphorus (P) from wastewater with the simulated vertical-flow constructed wetlands (VFCWs) under three different substrates (i.e., BFAS or blast furnace artificial slag, CBAS or coal burn artificial slag, and MSAS or midsized sand artificial slag), hydraulic loading rates (i.e., 7, 14, and 21 cm d?1), and wetland operational periods (0.5, 1, and 2 years) as well as with and without planting Canna indica L. The wastewater was collected from the campus of South China Agricultural University, Guangzhou, China. Results show that the percent removal of total P (TP) and ammonium N (NH4+-N) by the substrates was BFAS > CBAS > MSAS due to the high contents of Ca and Al in substrate BFAS. In contrast, the percent removal of total N (TN) by the substrates was CBAS > MSAS > BFAS due to the complicated nitrification/denitrification processes. The percent removal of nutrients by all of the substrates was TP > NH4+-N > TN. About 10% more TN was removed from the wastewater after planting Canna indica L. A lower hydraulic loading rate or longer hydraulic retention time (HRT) resulted in a higher removal of TP, NH4+-N, and TN because of more contacts and interactions among nutrients, substrates, and roots under the longer HRT. Removal of NO3?N from the simulated VFCWs is a complex process. A high concentration of NO3?N in the effluent was observed under the high hydraulic loading rate because more NH4+-N and oxygen were available for nitrification and a shorter HRT was unfavorable for denitrification. In general, a longer operational period had a highest removal rate for nutrients in the VFCWs.  相似文献   

7.
The treatment capacity of constructed wetlands is expected to be high in tropical areas because of the warm temperatures and the associated higher rates of microbial activity. A pilot scale horizontal subsurface flow constructed wetland system filled with river sand and planted with Phragmites vallatoria (L.) Veldkamp was set up in the southern part of Vietnam to assess the treatment capacity and the removal rate kinetics under tropical conditions. The system received municipal wastewater at four hydraulic loading rates (HLRs) of 31, 62, 104 and 146 mm day?1. Removals of TSS, BOD5 and COD were efficient at all HLRs with mean removal rates of 86–95%, 65–83% and 57–84%, respectively. Removals of N and P decreased with HLRs and were: NH4-N 0–91%; TN 16–84% and TP 72–99%. First-order area-based removal rate constants (k, m year?1) estimated from sampling along the length of the wetland from inlet to outlet at the four HLRs were in the range of 25–95 (BOD5), 22–30 (COD), 31–115 (TSS), 5–24 (TN and TKN) and 41–84 (TP) at background concentrations (C*) of 5, 10, 0, 1.5 and 0 mg L?1, respectively. The estimated k-values should not be used for design purposes, as site-specific differences and stochastic variability can be high. However, the study shows that domestic wastewater can be treated in horizontal subsurface flow constructed wetland systems to meet even the most stringent Vietnamese standards for discharge into surface waters.  相似文献   

8.
《Process Biochemistry》2007,42(2):199-209
The flow diverted bed (FDB) system was developed to improve the stream water quality. This system (Run 2) had two wetlands where the flow from the upper layer (aerobic) in the first wetland could be redirected to the lower layer (anaerobic) in the second wetland by the flow diverter, and vice versa. In addition, the yellow-soil media placed at the bottom layer allowed a larger influx in the lower layer and had a sorption capacity of phosphate ions. The removal efficiencies of COD and TN at Run 2 [hydraulic loading rate (HLR) = 177 cm/d] was 1.7–3.6 times higher than that at Run 1 (HLR = 192 cm/d) without the diverter. The values of void fraction, dimensionless variance, dispersion number, Peclet number and velocity for this system were found to be 0.6637, 0.2847, 0.1717, 5.8241, and 53.2 m/d, respectively. The reducing trend of each pollutant was exponentially decreased along the overall length of this system. Also, the transport was dominated by convection (plug flow) rather than dispersion (complete mix). The volumetric removal rate constants for COD, SS, TKN, TN, and TP were found to be 4.854, 7.988, 1.388, 1.625, and 1.767 d−1 via the first-order rate model. Consequently, the flow diverter and yellow-soil media in this system played an important role in enhancing the treatability of pollutants and operating at a higher HLR.  相似文献   

9.
《Ecological Engineering》2007,29(2):154-163
The South Nation River Watershed, in eastern Ontario, Canada, is an agricultural watershed impacted by excess nutrient loading primarily from agricultural activities. A constructed wetland for the treatment of agricultural wastewater from a 150-cow dairy operation in this watershed was monitored in its eighth operating season to evaluate the proportion of total nitrogen (TN) (approximated by total Kjeldahl nitrogen (TKN) due to low NO3) and total phosphorus (TP) removal that could be attributed to storage in Typha latifolia L. and Typha angustifolia L., which dominate this system. Nutrient loading rates were high, with 16.2 kg ha−1 d−1 N and 3.4 kg ha−1 d−1 P entering the wetland and loading the first wetland cell. Plant uptake accounted for 0.7% of TKN removal when the vegetated free water surface cells were considered together. However, separately, in the second wetland cell with lower N and P loading rates, plants accounted for 9% of TKN, 21% of NH4+ and 5% of TP removal. Plant uptake was significant to overall removal given wetland age and nutrient loading. Nutrient storage during the growing season at this constructed wetland helped reduce the nutrient load entering the watershed, already stressed by intensive local agriculture.  相似文献   

10.
《Process Biochemistry》2007,42(2):193-198
A pilot-scale vertical submerged membrane bioreactor (VSMBR) with anoxic and oxic zones in one reactor was operated in an attempt to reduce the problems concerning effective removal of organic matter and nutrients from municipal wastewater. Source water with total chemical oxygen demand (TCOD)/total nitrogen (TN) ratio of 5.5 was treated at various temperatures (13–25 °C) over an interval of about 1 year. As a result, total suspended solid (TSS) and TCOD were removed by 100% and higher than 98%, respectively. Moreover, the average removal efficiencies of TN and total phosphorus (TP) were found to be 74% and 78% at 8 h-hydraulic retention time (HRT) and 60-days sludge retention time (SRT). Under these conditions, the specific removal rates (SRR) of TN and TP were found to be 0.093 kg N m−3 day−1 and 0.008 kg P m−3 day−1, and the daily production of excess sludge (DPES), 0.058 kg TSS day−1.  相似文献   

11.
A membrane bioreactor filled with carriers instead of activated sludge named a moving bed membrane bioreactor (MBMBR) was investigated for simultaneously removing organic carbon and nitrogen in wastewater. Its performance was compared with a conventional membrane bioreactor (CMBR) at various influent COD/TN ratios of 8.9–22.1. The operational parameters were optimized to increase the treatment efficiency. COD removal efficiency averaged at 95.6% and 96.2%, respectively, for MBMBR and CMBR during the 4 months experimental period. The MBMBR system demonstrated good performance on nitrogen removal at different COD/TN ratios. When COD/TN was 8.9 and the total nitrogen (TN) load was 7.58 mg/l h, the TN and ammonium nitrogen removal efficiencies of the MBMBR were maintained over 70.0% and 80.0%, respectively, and the removed total nitrogen (TN) load reached to 5.31 mg/l h. Multifunctional microbial reactions in the carrier, such as simultaneous nitrification and denitrification (SND), play important roles in nitrogen removal. In comparison, the CMBR did not perform so well. Its TN removal was not stable, and the removed total nitrogen (TN) load was only 1.02 mg/l h at COD/TN ratio 8.9. The specific oxygen utilization rate (SOUR) showed that the biofilm has a better microbial activity than an activated sludge. Nevertheless, the membrane fouling behavior was more severe in the MBMBR than in the CMBR due to a thick and dense cake layer formed on the membrane surface, which was speculated to be caused by the filamentous bacteria in the MBMBR.  相似文献   

12.
Three pilot subsurface wastewater infiltration systems filled with the same mixed matrix made of 80% brown soil and cinder at a weight of 20% were constructed in the laboratory. All systems worked successfully in the intermittent feeding mode with total hydraulic loading of 4 m3/(m2 d) for over 2 months, with the optimal parameters of shunt ratio of 1:1 and shunt position at the depth of 0.7 m was achieved on the basis of large amounts of experimental data. The experiment results showed that shunt distributing wastewater could significantly improve the nitrogen removal in the subsurface infiltration system and the average removal rates of TN and NH4-N increased by 10% and 5.67%, respectively. Shunt distributing wastewater had little influence on the removal rates of COD and TP. The results suggested that shunt distributing wastewater was simple and effective for nitrogen removal.  相似文献   

13.
This study evaluates the potential of subsurface flow (SSF) constructed wetlands (CWs) for tertiary treatment of wastewater at four shorter HRTs (1–4 days). The CWs were planted with Typha angustata, which was observed in our earlier study to be more efficient than Phragmites karka and Scirpus littoralis. The CWs comprised four rectangular treatment cells (2.14 m × 0.76 m × 0.61 m) filled with layers of gravel of two different sizes (approximately 2.5 cm and 1.5 cm diameter) to a depth of 0.61 m. The inflow rates of the secondary effluent in the four cells were accordingly fixed at 300 L d?1, 150 L d?1, 100 L d?1 and 75 L d?1, respectively, for 1, 2, 3 and 4 days HRT. The hydraulic loads ranged between 59.05 mm d?1 and 236.22 mm d?1.The wastewater inflow into the CW system as well as the treated effluent were analyzed, using standard methods, at regular intervals for various forms of nitrogen (NH4-N, NO3-N and TKN), orthophosphate-P and organic matter (BOD and COD) concentrations over a period of five weeks after the development of a dense stand.The higher HRT of 4 days not only helped maximum removal of all the pollutants but also maintained the stability of the treatment efficiency throughout the monitoring period. For the nutrients (NH4-N, NO3-N and TKN), HRT played a more significant role in their removal than in case of organic matter (BOD3 and COD). More than 90% of NO3-N and TKN and 100% of NH4-N were removed from the wastewater at 4 days HRT.At lower HRTs, the mass loading rate was higher with greater fluctuation. However mass reduction efficiency of the T. angustata CW for all forms of nitrogen was >80% with the HRTs of 2, 3 and 4 days.  相似文献   

14.
In order to investigate the effect of temperature, hydraulic residence time (HRT), vegetation type, substrate material and wetland shape on the performance of free-water surface (FWS) constructed wetlands treating wastewater, 5 pilot-scale units were constructed and operated continuously from December 2004 until March 2007 in parallel experiments. Four of the units (A, B, C, D) were rectangular in plan view with dimensions 3.40 m in length and 0.85 m in width, and contained substrate material at a thickness of 0.45 m. The fifth unit (E) had a trapezoidal plan view shape, with a width at the inlet of 1.15 m and at the outlet of 0.55 m, while the length and the thickness of the substrate were the same as in the other four. All units operated at a water depth of 0.10 m. Units B–E contained clay substrate and unit A contained sand. The four units with clay were planted as follows: two with cattails (B and E), one with common reeds (C), and one with giant reeds (D). Unit A, containing sand, was planted with cattails. Planting and substrate material combinations were appropriate for comparison of the effect of vegetation and material type on the function of the system. Synthetic wastewater was introduced in the units. During the operation period four HRTs (i.e., 6 days, 8 days, 14 days and 20 days) were used, while wastewater temperatures varied from about 0.0 °C to 29.1 °C. The removal performance of the five constructed wetland units was good, since it reached on the average 77.5%, 67.9%, 60.4%, 53.9%, 56.0% and 51.7% for BOD, COD, TKN, ammonia (NH4-N), ortho-phosphate (PO4-P) and total phosphorus (TP), respectively. BOD and phosphorus removal efficiencies showed dependence on temperature in most units. The 14-day HRT was found adequate for acceptable removal of organic matter, nitrogen and phosphorus for most temperatures. A 20-day HRT is recommended for acceptable removal of BOD and PO4-P in the cold season. The unit with the trapezoidal plan view shape showed the best performance, with mean removals of 80.1%, 73.5%, 70.4%, 68.6%, 64.7% and 63.5% for BOD, COD, TKN, NH4-N, PO4-P and TP, respectively. The cattail was found statistically more efficient than the other two plants in COD and PO4-P removal. The unit that contained the clay substrate was found statistically more efficient in phosphorus removal than the unit containing sand. HSF CW units were found more efficient than FWS units in removal of most pollutant.  相似文献   

15.
Constructed treatment wetlands have served the City of Columbia, MO, for fourteen years. Four free water surface wetland units in series, comprised of 23 cells, are an addition to the activated sludge wastewater treatment plant, for the purpose of added biochemical oxygen demand (BOD) and total suspended solids (TSS) control. The system operates year-round, and supplies water to the Eagle Bluffs Conservation Area for wetland maintenance. The cattail wetlands processed an average of 57,000 m3/d, at a water depth of 20 cm. The resulting detention time was approximately 2 days, and the hydraulic loading was 13 cm/d. Water temperatures were warm leaving the treatment plant and in the wetlands in winter, because of the short detention. The period of record average carbonaceous biochemical oxygen demand (CBOD) leaving the wetlands was 5.0 mg/L, and the TSS was 14.7 mg/L. Dissolved oxygen was depressed in summer, likely because of the high sediment demand. Nutrient concentrations were only minimally reduced, total nitrogen (TN) by 22% and total phosphorus (TP) by 6%. However, load reductions were maximal, 98 t/yr for nitrogen, and 3.6 t/yr for phosphorus. Fecal coliforms were reduced by 98%, and E. coli by 95%. First order rate coefficients were high for CBOD (64 m/yr), nitrate (61 m/yr) and organic nitrogen (42 m/yr), but relatively low for ammonia (8 m/yr) and phosphorus (5.7 m/yr). Nitrogen removal was strongly affected by vegetative uptake. Sediment accretion in the wetland inlets was substantial, at 1.6 cm/yr in the inlets to the upstream wetland units. Muskrats caused vegetation damage, and waterfowl use was high in winter, causing TSS excursions.  相似文献   

16.
Wetlands provide a large pool of organic matter and nutrients, and are important for maintaining material cycle balances in terrestrial ecosystems, and also help retard climate change. Land use changes in wetlands have greatly disturbed the natural evolution of wetland ecosystems. Wetland drainage and reclamation alters the physical, chemical and biological conditions of the wetland, thus significantly disturbing the material cycles, leading to significant changes in the biogeochemical processes of carbon, nitrogen and phosphorus in the wetland. The wetlands in the Sanjiang Plain are the largest area of fresh wetlands in China. However, the area has experienced major land uses changes since the 1950s; areas of the wetland have been drained and converted to arable land. Some studies have been conducted into the effects of land use change on material cycles in the Sanjiang Plain wetlands but few reports have discussed the C/N and C/P ratios and pH values as indicators of wetland degradation due to land use changes. We selected eight land uses: humus marsh (HM), marshy meadow (MM), drained humus marsh (DHM), drained marshy meadow (DMM), tillage land (TL), abandoned land (AL), natural secondary forest (NSF) and artificial forest (AF), in the Honghe area of the Sanjiang Plain. We studied changes in the total organic carbon (TOC), total nitrogen (TN), total phosphorus (TP), C/N and C/P ratios and pH values in topsoil (0–20 cm) of these eight different land uses. The possible mechanisms underlying the changes, and the significance of the C/N and C/P ratios as indicators of soil quality were also discussed. In the natural wetland, the TOC, TN and TP concentrations in the soil were high, with values of 203.5 g/kg, 20.2 g/kg and 1.44 g/kg, respectively, in HM; and 59.2 g/kg, 5.28 g/kg and 0.83 g/kg, respectively, in MM. Drainage of the HM has led to decreases in the TOC, TN and TP concentrations of about 50%. Significant decreases were also observed in TOC, TN and TP for NSF and AF compared to HM. Drained MM led to decreases in the TOC and TN of about 45%, but had little effect on TP. Marshy meadow that had been drained for more than 10 years experienced an exponential decline in TOC, TN and TP, with decreases of more than 60% for TOC and TN, and 20% for TP. However, after being abandoned for a short time (5 years), the TOC, TN and TP concentrations in soil experienced little change because poor water conditions combined with low productivity led to a large loss of soil organic matter. Land use change in the marsh areas has led to a decrease in C/N and C/P ratios of the soil, which are positively related to TOC and TN with different land uses (P < 0.05). Marsh reclamation has led to decreasing C/N and C/P ratios in soil and increasing pH values, which are negatively related to TOC, TN and TP (P < 0.05). Changes in carbon, nitrogen and phosphorus in soil with different land uses were mainly regulated by water-heat conditions and microbial activity, while the C/N and C/P ratios were mainly regulated by substrate availability. Our results suggest that C/N and C/P ratios and the pH value could be used as indicators to evaluate the quality and nutrient status of wetland soil under different land uses.  相似文献   

17.
The properties and behaviour of solids retained in a pilot plant constituted of an up-flow anaerobic sludge blanket (UASB) reactor and two constructed wetlands (CWs) were monitored over a 3-year period. The UASB (25.5 m3) was fed with raw municipal wastewater at a flow rate of 61–112 m3 d?1 and a volumetric loading rate (VLR) of 0.75–1.70 kg TCOD m?3 d?1. The CWs (75 m2 each) were operated in series and received a fraction (17–20 m3 d?1) of the UASB effluent. The applied surface loading rates (SLR) were in the range of 3800–8700 g TCOD m?2 d?1 (UASB) and 11–15 g BOD5 m?2 d?1 (CWs). The overall system removed 95% TSS, 85% TCOD and 87% BOD5 on average. For influent VSS, the UASB removed 72.1% and gave a hydrolysis of 63.5%, while the average surplus sludge generation was 8.7%. Over the 3-year period, TSS and VSS accumulated in the CWs at rates of 1.07 and 0.56 kg m?2 year?1, respectively. The aerobic biodegradability of the accumulated solids ranged from 23 to 92 mg O2 g VSS?1 d?1 and increased downstream in the CWs. About 59% of the VSS that entered the CWs was removed by hydrolysis, while 24% accumulated on granular media. These low solids accumulation rates were especially remarkable considering the high COD and BOD5 loading rates applied. The system lay-out appear to be promising in terms of preventing clogging.  相似文献   

18.
The use of surface flow (SFCWs) and subsurface flow constructed wetlands (SFCWs) for the treatment of combined sewer overflows was assessed at pilot scale. Synthetic wastewater was applied in three batches with decreasing concentrations to mimic concentration profiles that are obtained in the field during overflow events. Three simulated combined sewer overflows were applied on each wetland. Composite water samples (60 in total) were taken for a period of 8 days to study the removal of total nitrogen (Ntot), NH4–N, NO3–N, total COD (CODtot) and total phosphorus. Redox potential, which was monitored at various locations along the wetlands, was more negative in the SSFCWs. In general, removal occurred faster in the SSFCWs and the final concentrations were lower. The removal of Ntot was only 36.6 ± 3.3% in the SFCWs due to nitrification-limiting conditions. The conditions in the SSFCWs, in contrast, seemed to promote Ntot removal (removal efficiency 96.7 ± 1.9%). The removal of P was hampered in both wetland types by reducing conditions. P that was initially removed was released again from the substrates later on. First-order removal rate constants were derived for the removal of both CODtot (SSFCWs: 1.1 ± 0.3 m d?1; SFCWs: 0.17 ± 0.06 m d?1) and Ntot (SSFCWs: 0.4 ± 0.1 m d?1; SFCWs: 1.7 ± 0.5 m d?1).  相似文献   

19.
In this study, a single chamber microbial fuel cell (MFC) with a rotating biocathode is developed to simultaneously remove chemical oxygen demand (COD) and nitrogen accompanying current production. Under continuous regime with a feeding COD/N ratio of 5:1, removal efficiencies of total organic carbon (TOC) and total nitrogen (TN) were 85.7 ± 7.4% and 91.5 ± 7.2%, respectively, and a maximum power output of 585 mW m?3 was yielded. In the batch tests, TN removal efficiencies for closed/open circuit were 82.1 ± 0.5% and 59.4 ± 3.3%, respectively. Cyclic voltammetry measurements demonstrated that the biocathode could efficiently catalyze nitrate reduction reaction. Autotrophic denitrification facilitated nitrogen removal using the electrode as electron donor. 16S rRNA-denaturing gradient gel electrophoresis (DGGE) was employed for community fingerprinting. At the biocathode the bacteria involved in nitrogen cycle predominated, of which the denitrifying bacteria were closely similar to Acidovorax sp. and/or Delftia sp. They were affiliated with the family Comamondaceae. The combination of rotating biological contactors with MFCs derives a promising opportunity for wastewater treatment with a low cost and high quality effluent.  相似文献   

20.
According to the characteristics of the reverse osmosis concentrate (ROC) generated from iron and steel company, we used three sets of parallel horizontal subsurface flow (HSF) constructed wetlands (CWs) with different plants and substrate layouts to treat the high-salinity wastewater. The plant growth and removal efficiencies under saline condition were evaluated. The evaluation was based entirely on routinely collected water quality data and the physical and chemical characteristics of the plants (Phragmites australis, Typha latifolia, Iris wilsonii, and Scirpus planiculmis). The principal parameters of concern in the effluent were chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP). The results showed that the CWs were able to remove COD, TN, and TP from ROC. S. planiculmis was not suitable for the treatment of high-saline wastewater. The sequence of metals accumulated in CW plants was K>Ca>Na>Mg>Zn>Cu. More than 70% of metals were accumulated in the aboveground of P. australis. The CW filled with gravel and manganese ore and planted with P. australis and T. latifolia had the best performance of pollutant removal, with average removal of 49.96%, 39.45%, and 72.01% for COD, TN, and TP, respectively. The effluent water quality met the regulation in China. These results suggested that HSF CW planted with P. australis and T. latifolia can be applied for ROC pollutants removal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号