首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for determining monohydroxybenzo[a]pyrene (OHBaP) isomers using column-switching high-performance liquid chromatography with fluorescence detection was developed. Eleven of 12 isomers of OHBaP (all except 6-OHBaP) were separated on an alkylamide-type reversed-phase column and, via column-switching, on a beta-cyclodextrin-bonded silica gel column. The detection limits for the OHBaPs were in the range 0.3-8 pg/injection (S/N=3). By using this method, 1-, 3-, and 9-OHBaPs were identified as major metabolites of benzo[a]pyrene in vitro by human recombinant p450 1A1. The method was used to determine OHBaPs in the urine of a nonsmoker subject. After enzymatic hydrolysis of the conjugated metabolites by beta-glucuronidase/aryl sulfatase, the analytes were selectively adsorbed on blue rayon (a cellulose-supported copper phthalocyanine) from the urine matrix. Methanol as the eluting solvent from the rayon gave the best recoveries of OHBaPs and 1-hydroxypyrene (1-OHP) in the range of 91-103%, which was superior to that of the solid-phase extraction method. 1-OHP, a well-known biomarker of the exposure to polycyclic aromatic hydrocarbons, was simultaneously analyzed. Intra- and interday accuracy values for the determination of 3-OHBaP in 200 ml of urine were 95.5 and 100.9%, and those for 1-OHP were 96.4 and 103.6%, respectively. The intra- and interday precision values were 3.9 and 2.4% for 3-OHBaP and 2.4 and 3.2% for 1-OHP, respectively. In 11 kinds of isomers, only 3-OHBaP was detected in the human urine. Urinary concentration of 3-OHBaP was quantified at 0.5 ng/g creatinine concentration and the 3-OHBaP/1-OHP ratio was approximately 1/130.  相似文献   

2.
The present work reports capillary liquid chromatographic column switching methodology tailored for fast, sensitive and selective determination of 1-hydroxypyrene (1-OHP) in human urine using micro-electrospray ionization time-of-flight mass spectrometric detection. Samples (100 microl) of deconjugated, water diluted and filtered urine samples were loaded onto a 150 microm I.D.x 30 mm 10 microm Kromasil C(18) pre-column, providing on-line sample clean-up and analyte enrichment, prior to back flushed elution onto a 150 microm I.D.x 100 mm 3.5 microm Kromasil C(18) analytical column. Loading flow rates up to 100 microl/min in addition to the use of isocratic elution by a mobile phase composition of acetonitrile/water (70/30, v/v) containing 5 mM ammonium acetate provided elution of 1-OHP within 5.5 min and a total analysis time of less than 15 min with manual operation. Ionization was performed in the negative mode and 1-OHP was observed as [M-H](-) at m/z 217.08. The method was validated over the concentration range 0.2-40 ng/ml 1-OHP in pre-treated urine, yielding a coefficient of correlation of 0.997. The within-assay (n=6) and between-assay (n=6) precisions were in the range 6.4-7.3 and 7.0-8.1%, respectively, and the recoveries were in the range 96.2-97.5 within the investigated concentration range. The method mass limit of detection was 2 pg, corresponding to a 1-OHP concentration limit of detection of 20 pg/ml (0.09 nmol/l) diluted urine or 0.3 ng/ml (1.35 nmol/l) urine.  相似文献   

3.
A sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of erucylphosphohomocholine (erufosine, ErPC(3)) in pharmacokinetic studies. Nine-fold deuterated ErPC(3) was used as the internal standard. Following protein precipitation, reversed phase chromatography was performed. For analyte detection, electrospray ionization in the positive mode was applied. The mass transition m/z 504.4>139.1 was recorded for ErPC(3), and the transition m/z 513.7>139.1 for the internal standard, respectively. Good linearity with a correlation coefficient >0.99 was found for the range of 0.48-15 mg/L ErPC(3) in plasma (0.93-29.8 microM), the important range for clinical pharmacokinetic analysis. Interassay coefficients (n=10) of variation between 4.2% and 5.5% were found for ErPC(3) pool samples with concentrations between 4.7 mg/L and 44.0mg/L, respectively. The method has been used for analyses during a phase I clinical trial of ErPC(3).  相似文献   

4.
Liquid chromatography-electrospray ionization mass spectrometry methods are described for the simultaneous quantification of a bis-thiazolium compound (T3), its related prodrug (TE3) and an intermediate compound (mTE3) that appeared during the prodrug/drug conversion process, in human plasma, whole blood and red blood cells (RBCs). The methods involve solid phase extraction (SPE) of the compounds and the internal standard (verapamil) from the three different matrices using OasisHLB columns with an elution solvent of 2x1 ml of acetonitrile containing 1 ml/l trifluoroacetic acid (TFA). HPLC separation was performed on a C18 encapped Xterra column packed with 3.5 microm particles. The mobile phase used a 8 min gradient, from water containing 1 ml/l TFA to acetonitrile containing 1 ml/l TFA, at a flow rate of 400 microl/min. Verapamil and the TE3 compound were characterized by the protonated molecules at m/z 455 and m/z 541, respectively. The mTE3 species was detected through the (M)+ ion at m/z 497. The T3 compound was detected by use of two ions, the quaternary ammonium salt (M2+/2) at m/z 227.3 and by the adduct with TFA (M+TFA)+ at m/z 567.3. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (or whole blood) concentrations in the tested range of 6.4-1282 microg/l (12.8-2564 microg/kg) for T3, 20-2000 microg/l (40-4000 microg/kg) for mTE3 and 10-2000 microg/l (40-4000 microg/kg) for TE3, and to T3 concentrations in RBCs ranging from 12.8 to 2564 microg/kg. Inter-assay precision (in terms of R.S.D.) was below 13.5% and accuracy ranged from 95.4 to 107%. The dilution of the samples (plasma or whole blood) has no influence on the performance of the methods. The extraction recoveries averaged 87% for T3, 53% for mTE3 and 79% for TE3 in plasma; 79% for T3, 57% for mTE3 and 65% for TE3 in blood; and 93% for T3 in RBCs, and was constant across the calibration range. The lower limits of quantitation were 6.4 microg/l for T3, 20 microg/l for mTE3 and 10 microg/l for TE3 in plasma; 12.8 microg/kg for T3 and 40 microg/kg for mTE3 and TE3 in blood; and 12.8 microg/kg for T3 in RBCs. Stability tests under various conditions were also investigated. The three-step SPE procedure (loading, clean-up, and elution) described in this paper to quantify these new anti-malarial compounds in plasma, whole blood and RBCs, can easily be automated by using either robotisation or an automated sample preparation system.  相似文献   

5.
A high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) method was established for the determination of gambogic acid (GA) in human plasma using ursolic acid as the internal standard (I.S.). Plasma samples were extracted with ethyl acetate and separated on a Hanbon Lichrospher 5-C18 column with a mobile phase of acetonitrile-tetrahydrofuran-water (70:23:7, v/v). Gambogic acid was determined by using atmospheric pressure chemical ionization (APCI) in a single quadrupole mass spectrometer. HPLC-APCI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M-H](-)m/z 627.4 for gambogic acid and [M-H](-)m/z 455.4 for the I.S. Calibration curve was linear over the range of 3.108-4144 microg/L. The lower limit of quantification was 3.108 microg/L. The intra- and inter-run precisions were less than 12.3 and 14.1%, respectively. The method has been successfully applied to study the pharmacokinetics of gambogic acid in patients with malignant tumour.  相似文献   

6.
A method is described for the quantitative determination of quinoxaline-2-carboxylic acid (QCA) and methyl-3-quinoxaline-2-carboxylic acid (MQCA), the metabolites that have been designated as the marker residues for the veterinary drugs, carbadox and olaquindox, respectively, in swine tissue. The method is suitable for use as a confirmatory method under EU National Surveillance Schemes. Porcine liver samples were subjected to protease digestion followed by liquid-liquid extraction. Further clean-up was performed by automated solid phase extraction (SPE) and was followed by a final liquid-liquid extraction step. Analysis was performed using a narrow bore column HPLC coupled to electrospray MS/MS, operated in positive ion mode. MS/MS product ions were monitored at m/z 102 and 75 amu for QCA, m/z 145 and 102 amu for MQCA and at m/z 106 and 152 amu for the d(4)-QCA and d(7)-MQCA internal standards, respectively. The method has been validated at 3.0, 10, 50 and 150 microg kg(-1) for both metabolites. The method performance characteristics-the decision limit (CCalpha) and the detection capability (CCbeta) have been determined for QCA at 0.4 and 1.2 microg kg(-1), respectively, and for MQCA at 0.7 and 3.6 microg kg(-1), respectively.  相似文献   

7.
We described the development and full validation of rapid and accurate liquid chromatography method, coupled with tandem mass spectrometry detection, for quantification of meprobamate in human plasma with [(13)C-(2)H(3)]-meprobamate as internal standard. Plasma pretreatment involved a one-step protein precipitation with acetonitrile. Separation was performed by reversed-phase chromatography on a Luna MercuryMS C18 (20 mm×4 mm×3 μm) column using a gradient elution mode. The mobile phase was a mix of distilled water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid. The selected reaction monitoring transitions, in electrospray positive ionization, used for quantification were 219.2→158.2 m/z and 223.1→161.1m/z for meprobamate and internal standard, respectively. Qualification transitions were 219.2→97.0 and 223.1→101.1 m/z for meprobamate and internal standard, respectively. The method was linear over the concentration range of 1-300 mg/L. The intra- and inter-day precision values were below 6.4% and accuracy was within 95.3% and 103.6% for all QC levels (5, 75 and 200 mg/L). The lower limit of quantification was 1 mg/L. Total analysis time was reduced to 6 min including sample preparation. The present method is successfully applied to 24/7 clinical toxicology and demonstrated its usefulness to detect meprobamate poisoning.  相似文献   

8.
Rauh M  Gröschl M  Rascher W  Dörr HG 《Steroids》2006,71(6):450-458
Plasma 17 alpha-hydroxyprogesterone (17-OHP), androstenedione and testosterone measurements are important for the diagnosis and monitoring of hyperandrogenic disorders, most importantly for congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency. The reliability of immunoassays has proved questionable especially for newborns and children. In order to reduce the analytical interferences due to cross-reactivity or matrix effects, to improve accuracy and shorten the analysis time, we have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with atmospheric pressure chemical ionization (APCI) for simultaneous measurement. An on-line extraction cartridge with column-switching technique and liquid chromatography over a Chromolith RP 18 e column allow a rapid and easy quantification. The lowest limit of detection was 0.03-0.06 microg/L. Our method has proved linear up to 250 microg/L (r=0.999). Recoveries (S.D.) of 17-OHP, androstenedione and testosterone in plasma were 100% (5), 102% (2) and 92% (4), respectively. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for 17-OHP (excluding neonate samples) was y=1.942 x+0.255 nmol/L (r=0.695; n=97). In comparison to our values, the immunoassay generally overestimates steroid concentration. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for testosterone was y=0.963 x+0.035 nmol/L (r=0.955; n=107). Preliminary reference intervals for children were determined as a function of age and sex. The sensitivity and specificity of the LC-MS/MS method offer advantages over routine immunoassays due to the elimination of interferences especially for newborns, high throughput and short chromatographic run time.  相似文献   

9.
A method is described for the quantitative confirmation of halofuginone (HFG) residues in chicken liver and eggs. This method is based on LC coupled to positive ion electrospray MS-MS of the tissue extracts, prepared by trypsin digestion of the tissues followed by liquid-liquid extraction and final clean-up using Solid Phase Extraction (SPE). The [M+H](+) ion at m/z 416 is monitored along with four transitions at m/z 398, 138, 120 and 100. The method has been validated according to the draft EU criteria for the analysis of veterinary drug residues at 15, 30 and 45 microg kg(-1) in liver and 5, 15 and 50 microg kg(-1) in eggs. The new analytical limits, CCalpha and CCbeta were calculated for liver and were 35.4 and 43.6 microg kg(-1), respectively.  相似文献   

10.
A liquid chromatography/electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the first time for the determination of ibogaine and noribogaine in human plasma and whole blood. The method involved solid phase extraction of the compounds and the internal standard (fluorescein) from the two matrices using OasisHLB columns. LC separation was performed on a Zorbax eclipse XD8 C8 column (5 microm) with a mobile phase of acetonitrile containing 0.02% (v/v) trimethylamine and 2mM ammonium formate buffer. MS data were acquired in single ion monitoring mode at m/z 311.2, 297.2 and 332.5 for ibogaine, noribogaine and fluorescein, respectively. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (0.89-179 microg/l for ibogaine; 1-200 microg/l for noribogaine) and to whole blood concentrations (1.78-358 microg/kg for ibogaine; 2-400 microg/kg for noribogaine). Precision ranged from 4.5 to 13% and accuracy was 89-102%. Dilution of the samples had no influence on the performance of the method. Extraction recoveries were > or =94% in plasma and > or =57% in whole blood. The lower limits of quantitation were 0.89 microg/l for ibogaine and 1 microg/l for noribogaine in plasma, and 1.78 microg/kg for ibogaine and 2 microg/kg for noribogaine in whole blood. In frozen plasma samples, the two drugs were stable for at least 1 year. In blood, ibogaine and noribogaine were stable for 4h at 4 degrees C and 20 degrees C and 2 months at -20 degrees C. The method was successfully used for the analysis of a poisoning involving Tabernanthe iboga root.  相似文献   

11.
We report on the quantitative determination of acetaminophen (paracetamol; NAPAP-d(0)) in human plasma and urine by GC-MS and GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode after derivatization with pentafluorobenzyl (PFB) bromide (PFB-Br). Commercially available tetradeuterated acetaminophen (NAPAP-d(4)) was used as the internal standard. NAPAP-d(0) and NAPAP-d(4) were extracted from 100-μL aliquots of plasma and urine with 300 μL ethyl acetate (EA) by vortexing (60s). After centrifugation the EA phase was collected, the solvent was removed under a stream of nitrogen gas, and the residue was reconstituted in acetonitrile (MeCN, 100 μL). PFB-Br (10 μL, 30 vol% in MeCN) and N,N-diisopropylethylamine (10 μL) were added and the mixture was incubated for 60 min at 30 °C. Then, solvents and reagents were removed under nitrogen and the residue was taken up with 1000 μL of toluene, from which 1-μL aliquots were injected in the splitless mode. GC-MS quantification was performed by selected-ion monitoring ions due to [M-PFB](-) and [M-PFB-H](-), m/z 150 and m/z 149 for NAPAP-d(0) and m/z 154 and m/z 153 for NAPAP-d(4), respectively. GC-MS/MS quantification was performed by selected-reaction monitoring the transition m/z 150 → m/z 107 and m/z 149 → m/z 134 for NAPAP-d(0) and m/z 154 → m/z 111 and m/z 153 → m/z 138 for NAPAP-d(4). The method was validated for human plasma (range, 0-130 μM NAPAP-d(0)) and urine (range, 0-1300 μM NAPAP-d(0)). Accuracy (recovery, %) ranged between 89 and 119%, and imprecision (RSD, %) was below 19% in these matrices and ranges. A close correlation (r>0.999) was found between the concentrations measured by GC-MS and GC-MS/MS. By this method, acetaminophen can be reliably quantified in small plasma and urine sample volumes (e.g., 10 μL). The analytical performance of the method makes it especially useful in pediatrics.  相似文献   

12.
A rapid and selective liquid chromatographic/tandem mass spectrometric method for determination of fosfomycin was developed and validated. Following protein-precipitation, the analyte and internal standard (fudosteine) were separated from human plasma using an isocratic mobile phase on an Ultimate XB-CN column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 137-->79 and m/z 178-->91 was performed to quantify fosfomycin and fudosteine, respectively. The method was linear in the concentration range of 0.10-12.0 microg/mL using 50 microL of plasma. The lower limit of quantification was 0.10 microg/mL. The intra- and inter-day relative standard deviation over the entire concentration range was less than 10.6%. Accuracy determined at three concentrations (0.25, 1.00 and 8.00 microg/mL for fosfomycin) ranged from -1.0% to -4.2% in terms of relative error. Each plasma sample was chromatographed within 5.0 min. The method was successfully used in a bioequivalence study of fosfomycin in human plasma after an oral administration of capsules containing 1.0 g fosfomycin (approximately 1.3g calcium fosfomycin).  相似文献   

13.
We report here the validation of an HPLC-electrospray-tandem mass spectrometry method for the quantification of everolimus, an immunosuppressant drug. Whole blood samples (100 microl) were extracted by protein precipitation which involved sample pre-treatment with zinc sulphate followed by acetonitrile (containing internal standard, 40-O-(3'-hydroxy)propyl-rapamycin). HPLC was performed using a step-gradient at a flow rate of 0.6 ml/min on a Waters TDM C18 column (10 mm x 2.1mm I.D.) with a resultant chromatographic analysis time of 2 min. Mass spectrometric detection by selected reaction monitoring (everolimus m/z 975.5-->908.3; internal standard m/z 989.5-->922.3). The assay was linear from 0.5 to 40 microg/l (r2>0.994, n=11). The inter- and intra-day analytical recovery and imprecision for quality control samples (1.25, 12.5 and 30 microg/l) were 93.4-98.2% and <10.7%, respectively (n=10). At the lower limit of quantification (0.5 microg/l) the inter- and intra-day analytical recovery was 94.4-95.8% with imprecision of <14.1% (n=10). The absolute recovery of everolimus (6.5 microg/l) and internal standard (12.5 microg/l) was 96.5 and 88.3%, respectively (n=3). A comparison of our method against the mean of all HPLC methods for a series of samples from an external proficiency testing scheme revealed good correlation as shown by the regression analysis: y=0.973x+0.301 (r2=0.986, n=71). In conclusion, the method described is suited to the current requirements for therapeutic drug monitoring of everolimus.  相似文献   

14.
A 96-well protein precipitation, liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated for the determination of fudosteine in human plasma. After protein precipitation of the plasma samples (50 microL) by the methanol (150 microL) containing the internal standard (IS), erdosteine, the 96-well plate was vortexed for 5 min and centrifuged for 15 min. The 100 microL supernatant and 100 microL mobile phase were added to another plate and mixed and then the mixture was directly injected into the LC-MS/MS system in the negative ionization mode. The separation was performed on a XB-CN column for 3.0 min per sample using an eluent of methanol-water (60:40, v/v) containing 0.005% formic acid. Multiple reaction monitoring (MRM) using the precursor-product ion transitions m/z 178-->91 and m/z 284-->91 was performed to quantify fudosteine and erdosteine, respectively. The method was sensitive with a lower limit of quantification (LLOQ) of 0.02 microg mL(-1), with good linearity (r>0.999) over the linear range of 0.02-10 microg mL(-1). The within- and between-run precision was less than 5.5% and accuracy ranged from 94.2 to 106.7% for quality control (QC) samples at three concentrations of 0.05, 1 and 8 microg mL(-1). The method was employed in the clinical pharmacokinetic study of fudosteine formulation product after oral administration to healthy volunteers.  相似文献   

15.
A sensitive and specific HPLC-MS/MS method was developed for the analysis of mycophenolic acid glucuronide (MPAG) in incubations with human liver microsomes. Incubation samples were processed by protein precipitation with acetonitrile. MPAG and the internal standard phenolphthalein glucuronide were chromatographed on a C18 Synergi Fusion-RP column (100 mm x 2 mm, 4 microm) using gradient elution with a mixture of 1mM acetic acid in deionized water and 1mM acetic acid in acetonitrile at a flow rate of 0.22 mL/min. The mass spectrometer was operated with negative electrospray ionization and analysis was carried out in the single reaction monitoring (SRM) mode using the mass transitions of m/z 495-->319 and m/z 493-->175 for MPAG and phenolphthalein glucuronide, respectively. The MPAG calibration curve was linear over the concentration range of 1.0-20 microM. The within-day and between-day relative standard deviations ranged from 1.1 to 7.9% and accuracy was within 8%. The simple and reproducible method is suitable for measuring mycophenolic acid glucuronidation in microsomal incubations.  相似文献   

16.
We developed and validated a simple high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection system for determining penciclovir (active metabolite of famciclovir) levels in human plasma using acyclovir as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 254.00>152.09 for penciclovir and m/z 226.00>152.09 for IS. The analytes were chromatographed on a Capcellpak MGII C(18) reversed-phase chromatographic column by isocratic elution using 30% methanol and 70% Milli-Q water containing 10 mM ammonium formate (adjusted to pH 3.1 with formic acid). Results were linear over the studied range (0.05-10 microg/ml) with r(2)=0.9999, and the total analysis time for each run was 2 min. Intra- and inter-assay precisions were 2.3-7.8 and 3.7-7.5%, respectively, and intra- and inter-assay relative errors (RE) were 2.0-8.4 and 1.9-9.1%, respectively. The lower limit of quantification (LLOQ) was 0.05 microg/ml. At this concentration mean intra- and inter-assay precisions were 7.8 and 7.5%, respectively, and mean intra- and inter-assay relative errors were 2.2 and 9.1%, respectively. Penciclovir was found to be stable in plasma samples under short-, long-term storage and processing conditions. The developed assay was successfully applied to a bioequivalence study of penciclovir administered as a single oral dose (500 mg as famciclovir) to healthy volunteers.  相似文献   

17.
Nitric oxide (NO), the endogenous modulator of vascular tone and structure, originates from oxidation of L-arginine catalysed by NO synthase (NOS). The L-arginine derivative L-homoarginine serves as an alternative NOS substrate releasing NO, competing with L-arginine for NOS, arginase, and arginine transport. In the present article we report a liquid chromatography-tandem mass spectrometric (LC-tandem MS) method for the determination of L-homoarginine in human plasma by stable-isotope dilution. L-[(13)C(6)]-Homoarginine was used as internal standard. This method provides high sample throughput of 25-μl aliquots of plasma with an analysis time of 4 min using LC-tandem MS electrospray ionisation in the positive mode (ESI+). Specific transitions for L-homoarginine and L-[(13)C(6)]-homoarginine were m/z 245 → m/z 211 and m/z 251 → m/z 217, respectively. The mean intra- and interassay CVs were 7.4 ± 4.5% (±SD) for 0.1-50 μmol/L and 7.5 ± 2.0% for 2 and 5 μmol/L, respectively. Applying this method, a mean plasma concentration of L-homoarginine of 2.5 ± 1.0 μmol/L was determined in 136 healthy humans.  相似文献   

18.
An analytical method for simultaneous determination of erythromycin propionate and its active metabolite, erythromycin base, in human plasma by high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS) was developed and validated. Roxithromycin was selected as the internal standard. The samples were directly injected after simple deproteinized procedure only. The separation was achieved on a Johnson Spherigel analytical column packed with 5 microm C18 silica, employing acetonitrile -0.1% formic acid aqueous solution (50:50) as mobile phase. The quantification of target compounds was obtained by using a selected ion monitoring (SIM) at m/z 790.7 for erythromycin propionate, m/z 734.7 for erythromycin base and m/z 837.8 for roxithromycin. The correlation coefficients of the calibration curves were better than 0.997 (n=6), in the ranges from 2 ng/ml to 1 microg/ml, and from 1 to 10 microg/ml for erythromycin propionate and base. The method can provide the necessary sensitivity, precision and accuracy to allow the simultaneous determination of both compounds in a patient's plasma following a single administration of erythromycin stinoprate capsule (500 mg erythromycin base equivalent).  相似文献   

19.
A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for the determination of ulifloxacin, the active metabolite of prulifloxacin, in human plasma is described. After sample preparation by protein precipitation with methanol, ulifloxacin and ofloxacin (internal standard) were chromatographically separated on a C(18) column using a mobile phase consisting of methanol, water and formic acid (70:30:0.2, v/v/v) at a flow rate of 0.5 ml/min and then were detected using MS/MS by monitoring their precursor-to-product ion transitions, m/z 350-->m/z 248 for ulifloxacin and m/z 362-->m/z 261 for ofloxacin, in selected reaction monitoring (SRM) mode. Positive electrospray ionization was used for the ionization process. The linear range was 0.025-5.0 microg/ml for ulifloxacin with a lower limit of quantitation of 0.025 microg/ml. Within- and between-run precision was less than 6.6 and 7.8%, respectively, and accuracy was within 2.0%. The recovery ranged from 92.1 to 98.2% at the concentrations of 0.025, 0.50 and 5.0 microg/ml. Compared with the reported LC method, the present LC-MS/MS method can directly determine the ulifloxacin in human plasma without any need of derivatization. The present method has been successfully used for the pharmacokinetic studies of a prulifloxacin formulation product after oral administration to healthy volunteers.  相似文献   

20.
A specific and sensitive liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the determination of free and total ropivacaine in human plasma. The work-up procedure involved a simple precipitation of plasma proteins with methanol. Etidocaine served as the internal standard. After microscale equilibrium-dialysis, measurement of free ropivacaine levels was performed after direct injection of the dialysate into the chromatograph. The system used a Zorbax eclipse XD8 C8 analytical column packed with 5 microm diameter particles as the stationary phase. The mobile phase consisted of a 15-min gradient (mobile phase A: 0.05% (v/v) trimethylamine in acetonitrile, mobile phase B: 2mM ammonium formate buffer (pH 3)). Mass spectrometric data were acquired in single ion monitoring mode at m/z 275 for ropivacaine and m/z 277 for etidocaine. The drug/internal standard peak area ratios (plasma) or peak areas (dialysate) were linked via a quadratic relationship to concentrations. Precision ranged from 1 to 7.6% accuracy was between 92.6 and 109%. The lower limits of quantitation were 1 microg/l in plasma and 2 microg/l in the dialysate. This method was found suitable for the analysis of plasma samples collected during a clinical trial performed in 30 infants undergoing epidural anaesthesia or continuous psoas compartment block.  相似文献   