首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We report a case of sarcoidosis presenting initially as atrial fibrillation(AF). His response to anti-arrhythmic treatment strategy was suboptimal. On initiation of immunosuppressive therapy, AF was better controlled. This interesting case highlights a likely link between inflammation and pathogenesis of atrial fibrillation.  相似文献   

2.
After initial documentation of excellent efficacy with radiofrequency ablation, this procedure is being performed increasingly in more complex situations and for more difficult arrhythmia. In these circumstances, an accurate knowledge of the anatomic basis for the ablation procedure will help maintain this efficacy and improve safety. In this review, we discuss the relevant anatomy for electrophysiology interventions for typical right atrial flutter, atrial fibrillation, and outflow tract ventricular tachycardia. In the pediatric population, maintaining safety is a greater challenge, and here again, knowing the neighboring and regional anatomy of the arrhythmogenic substrate for these arrhythmias may go a long way in preventing complications.  相似文献   

3.
4.
5.

Background

Paroxysmal atrial fibrillation (PAF) is defined as recurrent AF terminating spontaneously within 7 days. This definition allows the consideration of any AF occurrence lasting < 7 days as paroxysmal, irrespective of the frequency and duration of episodes. The aim of this study was to investigate symptomatic AF burden (AFB) defined as total duration of symptomatic AF episodes within 3 months prior to abalation, for prediction of outcome after pulmonary vein isolation (PVI).

Methods

A total of 320 consecutive patients with symptomatic AF (PAF=244, men=214, age=58 y) were enrolled. AFB in patients with PAF was defined as time spent in AF within 3 months prior to PVI. After the AFB cut-off point was optimized at 500 h, patients with PAF were categorized into 2 groups: Group 1 - patients with AFB< 500 h (n=192), Group 2 - patients with AFB≥ 500 h (n=52). Patients with persistent AF (PersAF, n = 76) comprised control group (Group 3). PVI was performed either with irrigated tip catheter (n=215) or using cryoballoon (n=105). The endpoint of study was first documented recurrence of AF >30 sec.

Results

Symptomatic AFB was found to be appropriate for prediction of outcome after PVI. The freedom from AF within 2 years was observed in 69%, 31%, and 43% patients in Group 1, 2 and 3, respectively (Group 1 vs. Group 2, p < .001; Group 1 vs. Group 3, p< .001; Group 2 vs. Group 3, p = 0.46).

Conclusions

Low AFB < 500 h /3 months was associated with better outcome after PVI. Patients with PAF and high AFB should be treated as patients with PersAF.  相似文献   

6.
NT-proBNP is produced from both atria and ventricles. The primary regulation of production is at the synthesis level. The plasma half-life of NT-proBNP is 60-120 min. Cutoff value of NT-proBNP for diagnosis of heart failure is 125 pg/ml in the age group below 75 years and 450 pg/ml in the age group above 75 years. It increases in atrial fibrillation and drops after successful cardioversion. High levels predict development of atrial fibrillation (AF) in healthy persons with sinus rhythm (SR). Some studies concluded that baseline level predicts maintenance of SR after cardioversion of AF while some others found that it did not. Many studies have proven that it is useful in monitoring rhythm stability after cardioversion of AF. Since it is increased in many other conditions, out of which some may also cause AF, care must be taken before ascribing changes in its level to AF alone.  相似文献   

7.

Background

It is suggested that an elevated left atrial pressure (LAP) promotes ectopic beats emanating in the pulmonary veins (PVs) and that LAP might be a marker for structural remodeling. This study aimed to identify if the quantification of LAP correlates with structural changes of the LA and may therefore be associated with outcomes following pulmonary vein isolation (PVI).

Methods

We analysed data from 120 patients, referred to PVI due to drug-refractory atrial fibrillation (AF) (age 63±8; 57% men). The maximum (mLAP) and mean LAP (meLAP) were measured after transseptal puncture.

Results and Conclusions

Within a mean follow-up of 303±95 days, 60% of the patients maintained in sinus rhythm after the initial procedure and 78% after repeated PVI. Performing univariate Cox-regression analysis, type of AF, LA-volume (LAV), mLAP and the meLAP were significant predictors of recurrence after PVI (p=0.03; p=0.001; p=0.01). In multivariate analysis mLAP>18mmHg, LAV>100 ml and the presence of persistent AF were significant predictors (p=0.001; p=0.019; p=0.017). The mLAP >18 mmHg was associated with a hazard ratio of 3.8. Analyzing receiver-operator characteristics, the area under the curve for mLAP was 0.75 (p<0.01). mLAP >18 mmHg predicts recurrence with a sensitivity of 77 % and specificity of 60 %. There was a linear correlation between the LAV from MDCT and mLAP (p = 0.01, R2 = 0.61). The mLAP measured invasively displays a significant predictor for AF recurrence after PVI. There is a good correlation between LAP and LAV and both factors may be useful to quantify LA remodeling.  相似文献   

8.
BackgroundAtrial fibrillation (AF) is correlated with a poor biventricular pacing and inadequate response to cardiac resynchronization therapy (CRT). Biventricular pacing improvement can be achieved by conducting the atrioventricular junction ablation (AVJA). We aimed to investigate the benefit of AVJA for permanent AF and heart failure with reduced ejection fraction (HFrEF) patients receiving CRT.MethodsIn August 2020, a systematic review and meta-analysis study comparing CRT plus AVJA versus CRT for permanent AF and HFrEF patients was conducted. Relevant articles were identified through the electronic scientific database such as ClinicalTrials.gov, ProQuest, ScienceDirect, PubMed, and Cochrane. The pooled risk ratio (RR) and pooled mean difference (MD) were estimated.ResultsA total of 3199 patients from 14 cohort studies were involved in this study. Additional AVJA reduced cardiovascular mortality (RR = 0.75, 95% confidence interval [CI] = 0.61 to 0.93, P < 0.01) in permanent AF and HFrEF patients receiving CRT. Biventricular pacing rate was higher in CRT plus AVJA group (MD = 8.65%, 95% CI = 5.62 to 11.67, P < 0.01) than in CRT alone group. The reverse remodeling characterized by the reduction of left ventricular end-diastolic diameter (LVEDD) was greater in the CRT plus AVJA group (MD = ?2.11 mm, 95% CI = ?3.79 to ?0.42, P = 0.01).ConclusionIn permanent AF and HFrEF patients receiving CRT, AVJA effectively increased the biventricular pacing rate. Adequate biventricular pacing rate provided a better response to the CRT marked by the greater ventricular reverse remodeling and survival from cardiovascular mortality.  相似文献   

9.
目的:探讨血清尿酸(UA)、超敏C反应蛋白(hs-CRP)、左心房内径(LAD)与老年永久性房颤的相关性。方法:选取2012年8月至2015年9月于首都医科大学宣武医院综合科住院的老年永久性房颤患者78例作为房颤组,选取同期住院窦性心律且无房颤病史的老年患者72例作为对照组,记录各组一般资料及超声心动图、尿酸、hs-CRP水平等,进行比较及相关性分析。结果:1与对照组相比,房颤组血清UA及hs CRP水平、左心房内径大小明显增高(P0.05),2以房颤是否发生为因变量,多因素logistic回归分析显示血清尿酸(OR=2.016,P=0.004)、左房内径(OR=4.180,P=0.001)和hs-CRP(OR=2.846,P=0.002)是老年永久性房颤发生的独立危险因素。3房颤组患者血清尿酸与hs-CRP水平呈正相关(r=0.28,P0.05),尿酸与左心房内径大小呈轻度正相关(r=0.12,P0.05)。结论:血清尿酸、hs-CRP、左房内径是老年永久性房颤发生的独立危险因素;尿酸参与的炎症反应和结构重构可能参与老年永久性房颤的发生。  相似文献   

10.

Aims

To evaluate the effects of pulmonary vein isolation (PVI) in terms of feasibility, safety and success rate on a midterm follow-up period in septuagenarians undergoing ablation with the Arctic Front Cryoballoon for atrial fibrillation (AF).

Methods and Results

We prospectively enrolled 21 patients aged 70 years or older (14 male; age 73 ± 2.5 years) elected to circumferential PVI with the 28mm cryoballoon for symptomatic drug resistant paroxysmal AF. A total number of 82 pulmonary veins (PV) were evidenced. Successful isolation could be obtained in all 82 (100%) PV ostia at the end of procedure. No major complication occurred during procedure. At a mean follow-up of 11.5 ± 4.7 months following ablation, 62% of patients did not present recurrence of atrial arrhythmias.

Conclusion

Cryoballoon ablation may be feasible and safe in older patients. Moreover a large proportion of the latter did not present AF recurrence during follow-up.  相似文献   

11.
BackgroundCryoballoon ablation (CBA) has been proven to be very effective for pulmonary vein (PV) isolation (PVI) if complete occlusion is achieved and conventionally assessed by angiographic injection of contrast within PV lumen. The aim of our study was to assess the usefulness of saline contrast intracardiac echocardiography in guiding CBA with respect to PV angiography.MethodsThirty consecutive patients with paroxysmal atrial fibrillation were randomly assigned fluoroscopy plus color-flow Doppler (n = 15; group 1: an iodinated medium as both angiographic and echographic contrast) or contrast intracardiac echocardiography plus color-flow Doppler (n = 15; group 2: saline contrast) for guidance of CBA.ResultsWe evaluated 338 occlusions of 107 PVs. The intracardiac echocontrastography-guided assessment of occlusion, defined as loss of echocontrastographic back-flow to the left atrium after saline injection regardless of the visualization of PV antrum, showed a high level of agreement with the angiographic diagnosis of occlusion. PVI rate was similar in both groups and effectively guided by intracardiac echocontrastography (PVI using ≤ 2 double cryofreezes: 89% of PVs in group 1 vs. 91% in group 2; p=n.s.). Group 2 patients had significantly shorter procedure (127 ± 16 vs. 152 ± 19 minutes; p<0.05) and fluoroscopy times (30 ± 12 vs. 43 ± 9 minutes, p<0.05) and used a lower iodinated contrast (88 ± 26 vs. 190 ± 47 mL, p<0.05).ConclusionsPV occlusion and PVI during cryoablation can be effectively predicted by intracardiac saline echocontrastography. This technique reduces procedural time, radiological exposure and iodinated contrast use.  相似文献   

12.
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, affecting millions of individuals worldwide 1-3. The rapid, irregular, and disordered electrical activity in the atria gives rise to palpitations, fatigue, dyspnea, chest pain and dizziness with or without syncope 4, 5. Patients with AF have a five-fold higher risk of stroke 6.Oral anticoagulation (OAC) with warfarin is commonly used for stroke prevention in patients with AF and has been shown to reduce the risk of stroke by 64% 7. Warfarin therapy has several major disadvantages, however, including bleeding, non-tolerance, interactions with other medications and foods, non-compliance and a narrow therapeutic range 8-11. These issues, together with poor appreciation of the risk-benefit ratio, unawareness of guidelines, or absence of an OAC monitoring outpatient clinic may explain why only 30-60% of patients with AF are prescribed this drug 8.The problems associated with warfarin, combined with the limited efficacy and/or serious side effects associated with other medications used for AF 12,13, highlight the need for effective non-pharmacological approaches to treatment. One such approach is catheter ablation (CA), a procedure in which a radiofrequency electrical current is applied to regions of the heart to create small ablation lesions that electrically isolate potential AF triggers 4. CA is a well-established treatment for AF symptoms 14, 15, that may also decrease the risk of stroke. Recent data showed a significant decrease in the relative risk of stroke and transient ischemic attack events among patients who underwent ablation compared with those undergoing antiarrhythmic drug therapy 16.Since the left atrial appendage (LAA) is the source of thrombi in more than 90% of patients with non-valvular atrial fibrillation 17, another approach to stroke prevention is to physically block clots from exiting the LAA. One method for occluding the LAA is via percutaneous placement of the WATCHMAN LAA closure device. The WATCHMAN device resembles a small parachute. It consists of a nitinol frame covered by fabric polyethyl terephthalate that prevents emboli, but not blood, from exiting during the healing process. Fixation anchors around the perimeter secure the device in the LAA (Figure 1). To date, the WATCHMAN is the only implanted percutaneous device for which a randomized clinical trial has been reported. In this study, implantation of the WATCHMAN was found to be at least as effective as warfarin in preventing stroke (all-causes) and death (all-causes) 18. This device received the Conformité Européenne (CE) mark for use in the European Union for warfarin eligible patients and in those who have a contraindication to anticoagulation therapy 19.Given the proven effectiveness of CA to alleviate AF symptoms and the promising data with regard to reduction of thromboembolic events with both CA and WATCHMAN implantation, combining the two procedures is hoped to further reduce the incidence of stroke in high-risk patients while simultaneously relieving symptoms. The combined procedure may eventually enable patients to undergo implantation of the WATCHMAN device without subsequent warfarin treatment, since the CA procedure itself reduces thromboembolic events. This would present an avenue of treatment previously unavailable to patients ineligible for warfarin treatment because of recurrent bleeding 20 or other warfarin-associated problems.The combined procedure is performed under general anesthesia with biplane fluoroscopy and TEE guidance. Catheter ablation is followed by implantation of the WATCHMAN LAA closure device. Data from a non-randomized trial with 10 patients demonstrates that this procedure can be safely performed in patients with a CHADS2 score of greater than 1 21. Further studies to examine the effectiveness of the combined procedure in reducing symptoms from AF and associated stroke are therefore warranted.  相似文献   

13.
目的:观察房颤及房颤并发血栓栓塞患者血浆内脑钠肽(brain natriuretic peptide,BNP)和D-二聚体(D-dimer)的表达水平;探讨两者表达水平的关联性以及两者对房颤血栓栓塞的预测价值。方法:回顾分析2010年5月-2012年12月上海市第一人民医院心内科住院病人;根据入组及排除标准将符合条件的研究对象74例分为对照组、单纯房颤组与房颤血栓组;对所有对象进行数据采集,包括年龄、性别、血脂情况、高血压病史、血糖等情况;对所有对象进行D-dimer及BNP水平的数据采集。结果:(1)房颤血栓组的年龄明显高于对照组(P0.01)和单纯房颤组(P0.001);(2)房颤血栓组的D-dimer和BNP水平高于单纯房颤组(P0.05)和对照组(P0.001);(3)单纯房颤组BNP水平与D-dimer水平呈正相关性(r=0.507,P=0.004),房颤血栓组BNP水平与D-dimer水平呈正相关性(r=0.680,P0.001)。结论:(1)心房颤动患者随着年龄的增加并发血栓栓塞风险也增加,指导我们在临床治疗时需要重视年龄因素。(2)患者血浆中D-dimer和BNP水平的增高是心房颤动并发血栓栓塞患者的危险信号。(3)D-dimer和BNP检测在预防心房颤动并发血栓栓塞中有重要的临床意义。  相似文献   

14.
Atrial fibrillation (AF) is the most common cardiac arrhythmia, affecting an estimated 6 million people in the United States 1. Since AF affects primarily elderly people, its prevalence increases parallel with age. As such, it is expected that 15.9 million Americans will be affected by the year 2050 2. Ischemic stroke occurs in 5% of non-anticoagulated AF patients each year. Current treatments for AF include rate control, rhythm control and prevention of stroke 3.The American College of Cardiology, American Heart Association, and European Society of Cardiology currently recommended rate control as the first course of therapy for AF 3. Rate control is achieved by administration of pharmacological agents, such as β-blockers, that lower the heart rate until it reaches a less symptomatic state 3. Rhythm control aims to return the heart to its normal sinus rhythm and is typically achieved through administration of antiarrhythmic drugs such as amiodarone, electrical cardioversion or ablation therapy. Rhythm control methods, however, have not been demonstrated to be superior to rate-control methods 4-6. In fact, certain antiarrhythmic drugs have been shown to be associated with higher hospitalization rates, serious adverse effects 3, or even increases in mortality in patients with structural heart defects 7. Thus, treatment with antiarrhythmics is more often used when rate-control drugs are ineffective or contraindicated. Rate-control and antiarrhythmic agents relieve the symptoms of AF, including palpitations, shortness of breath, and fatigue 8, but don''t reliably prevent thromboembolic events 6.Treatment with the anticoagulant drug warfarin significantly reduces the rate of stroke or embolism 9,10. However, because of problems associated with its use, fewer than 50% of patients are treated with it. The therapeutic dose is affected by drug, dietary, and metabolic interactions, and thus requires detailed monitoring. In addition, warfarin has the potential to cause severe, sometimes lethal, bleeding 2. As an alternative, aspirin is commonly prescribed. While aspirin is typically well tolerated, it is far less effective at preventing stroke 10. Other alternatives to warfarin, such as dabigatran 11 or rivaroxaban 12 demonstrate non-inferiority to warfarin with respect to thromboembolic events (in fact, dabigatran given as a high dose of 150 mg twice a day has shown superiority). While these drugs have the advantage of eliminating dietary concerns and eliminating the need for regular blood monitoring, major bleeding and associated complications, while somewhat less so than with warfarin, remain an issue 13-15.Since 90% of AF-associated strokes result from emboli that arise from the left atrial appendage (LAA) 2, one alternative approach to warfarin therapy has been to exclude the LAA using an implanted device to trap blood clots before they exit. Here, we demonstrate a procedure for implanting the WATCHMAN Left Atrial Appendage Closure Device. A transseptal cannula is inserted through the femoral vein, and under fluoroscopic guidance, inter-atrial septum is crossed. Once access to the left atrium has been achieved, a guidewire is placed in the upper pulmonary vein and the WATCHMAN Access Sheath and dilator are advanced over the wire into the left atrium. The guidewire is removed, and the access sheath is carefully advanced into the distal portion of the LAA over a pigtail catheter. The WATCHMAN Delivery System is prepped, inserted into the access sheath, and slowly advanced. The WATCHMAN device is then deployed into the LAA. The device release criteria are confirmed via fluoroscopy and transesophageal echocardiography (TEE) and the device is released.  相似文献   

15.

Background

Paroxysmal atrial tachyarrhythmias frequently occur in beta-thalassemia major (β-TM) patients.The aim of our study was to investigate the role of maximum P-wave duration (P max) and dispersion (PD), calculated trough a new manually performed measurement with the use of computer software from all 12-ECG-leads,as predictors of atrial-fibrillation (AF) in β-TM patients with conserved systolic or diastolic cardiac function during a twelve-months follow-up.

Materials and Methods

50 β-TM-patients (age38.4±10.1; 38M) and 50-healthy subjects used as controls, matched for age and gender, were studied for the occurrence of atrial arrhythmias during a 1-year follow-up, through ECG-Holter-monitoring performed every three months. The β-TM-patients were divided into two groups according to number and complexity of premature-supraventricular-complexes at the Holter-Monitoring (Group1: <30/h and no repetitive forms, n:35; Group2: >30/h or couplets, or run of supraventricular tachycardia and AF, n:15).

Results

Compared to the healthy control-group, β-TM patients presented increased P-max (107.5± 21.2 vs 92.1±11ms, P=0.03) and PD-values (41.2±13 vs 25.1±5 ms,P=0.03). In the β-TM population, the Group2 showed a statistically significant increase in PD (42.8±8.6 vs 33.2±6.5ms, P<0.001) and P-max (118.1±8.7 vs 103.1±7.5ms, P<0.001) compared to the Group1. Seven β-TM patients who showed paroxysmal AF during this study had significantly increased P-max and PD than the other patients of the Group2. Moreover, P-max (OR:2.01; CI:1.12-3.59; P=0.01) and PD (OR=2.06;CI:1.17-3.64;P=0.01) demonstrated a statistically significant association with the occurrence of paroxysmal AF,P min was not associated with AF-risk (OR=0.99; CI:0.25-3.40; P=0.9) in β-TM-patients. A cut-off value of 111ms for P-max had a sensitivity of 80% and a specificity of 87%, a cut-off value of 35.5ms for PD had a sensitivity of 90% and a specificity of 85% in identifying β-TM patients at risk for AF.

Conclusion

Our results indicate that P-max and PD are useful electrocardiographic markers for identifying the β-TM-high-risk patients for AF onset, even when the cardiac function is conserved.  相似文献   

16.
目的:探讨左房内径(LAD)、血清尿酸(UA)水平与老年心房颤动的相关性。方法:选择2013年1月至2016年7月在我院住院的60岁以上的非瓣膜性房颤患者,共166例,其中持续性房颤组85例,阵发性房颤组81例,选择同期无房颤的高血压、冠心病老年患者83例作对照组。通过心脏彩超检查检测LAD、左心室舒张末期内径(LVDD)、左心室收缩末期内径(LVDS)、左心室射血分数(LVEF),以≥40 mm为左房内径增大。并采用生化分析检测患者血清UA水平。结果:(1)持续性房颤组LAD、LVEF、左心房增大发生率均显著高于阵发性房颤组和对照组,而阵发性房颤组以上指标均明显高于对照组,差异具有统计学意义(P0.05)。(2)持续性房颤组和阵发性房颤组患者血清UA水平均显著高于对照组,但持续性房颤组和阵发性房颤组之间血清UA水平比较差异无统计学意义(P0.05)。结论:左心房内径大小、血尿酸水平与老年患者心房颤动的发生密切相关。  相似文献   

17.
房颤是临床上最常见的持续性心律失常.揭示房颤的发病机制和病理生理过程是其诊断、预防、治疗、药物研发及临床设备设计的关键,而实验和临床只能呈现细胞或亚细胞的局部特性及房颤病症的宏观结果.随着生物信息技术、统计分析技术等的发展,运用多物理尺度的虚拟生理心脏模型,来实现宏观结果与微观机制相统一的研究方法备受关注.本文综述了离子通道、心肌细胞、心脏组织及器官等多尺度的虚拟生理心脏模型研究进展,探讨了近年来基于虚拟生理心脏模型的房颤机制研究以及房颤的治疗手段,提示了房颤研究的挑战和未来的发展方向.  相似文献   

18.
目的:探讨房颤射频消融术后肺静脉狭窄的相关因素,为其预防提供依据。方法:收集113例射频消融房颤患者的临床资料,记录射频术中消融时间、阻抗和温度;术后6个月64层CT左房-肺静脉重建随访,统计肺静脉狭窄的发生率;多元Logistic回归分析肺静脉狭窄的相关因素。结果:依据肺静脉数量计算的肺静脉狭窄率为3.4%,按照患者数量计算的肺静脉狭窄率为7.7%。多元Logistic回归分析,初始50例手术较其后病例的OR为2.167,95%CI=1.038~9.857,P=0.046,消融时间在总消融时间均数之上的患者比在均数之下者OR为2.856,95%CI=1.352~6.043,P=0.021。结论:初始50例手术和消融时间长是房颤射频消融术后肺静脉狭窄的相关因素。  相似文献   

19.
目的:通过探讨不同剂量胺碘酮联合氯沙坦治疗阵发性房颤(PAF)患者的临床疗效,为PAF的治疗提供参考。方法:选择2013年6月~2014年6月本院收治的PAF患者共84例,按照随机数字表法随机分为大剂量组和小剂量组,分别在治疗1、3、6、12个月后观察两组患者窦性心律维持效果、左心室功能和血清高敏C反应蛋白(Hs-CRP)水平。结果:治疗1个月后,两组患者窦性心律维持效果的总有效率分别为93.73%和90.00%,差异无统计学意义(x~2=2.235;P0.05)。治疗3、6和12个月后,小剂量组患者窦性心律维持有效率均高于大剂量组,差异有统计学意义(x~2=4.208、5.271、5.688;P0.05)。小剂量组患者最大P波时限(Pmax)、P波离散度(Pd)和左心房直径(LAD)值均显著低于大剂量组患者,差异有统计学意义(t=-6.071、-3.509、-3.998;P0.05);左心室射血分数(LVEF)值显著高于大剂量组患者,差异有统计学意义(t=3.935;P0.05)。治疗1、6和12个月后,小剂量组血清Hs-CRP水平均低于大剂量组,差异有统计学意义(t=-4.515、-10.431、-19.113;P0.05)。结论:小剂量胺碘酮联合氯沙坦能够有效提高阵发性房颤患者窦性心律维持效果,改善患者左心室功能,降低Hs-CRP水平,值得临床推广借鉴。  相似文献   

20.
目的:探讨房颤射频消融术后肺静脉狭窄的相关因素,为其预防提供依据。方法:收集113例射频消融房颤患者的临床资料,记录射频术中消融时间、阻抗和温度;术后6个月64层CT左房-肺静脉重建随访,统计肺静脉狭窄的发生率;多元Logistic回归分析肺静脉狭窄的相关因素。结果:依据肺静脉数量计算的肺静脉狭窄率为3.4%,按照患者数量计算的肺静脉狭窄率为7.7%。多元Logistic回归分析,初始50例手术较其后病例的OR为2.167,95%CI=I.038-9.857,P=0.046,消融时间在总消融时间均数之上的患者比在均数之下者OR为2.856,95%CI=1.352-6.043,P=0.021。结论:初始50例手术和消融时间长是房颤射频消融术后肺静脉狭窄的相关因素。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏