1.

Purpose

To evaluate the effect of introduction of iterative reconstruction as a mandated software upgrade on radiation dosimetry in routine clinical practice over a range of computed tomography examinations.

Methods

Random samples of scanning data were extracted from a centralised Picture Archiving Communication System pertaining to 10 commonly performed computed tomography examination types undertaken at two hospitals in Western Australia, before and after the introduction of iterative reconstruction. Changes in the mean dose length product and effective dose were evaluated along with estimations of associated changes to annual cancer incidence.

Results

We observed statistically significant reductions in the effective radiation dose for head computed tomography (22–27%) consistent with those reported in the literature. In contrast the reductions observed for non-contrast chest (37–47%); chest pulmonary embolism study (28%), chest/abdominal/pelvic study (16%) and thoracic spine (39%) computed tomography. Statistically significant reductions in radiation dose were not identified in angiographic computed tomography. Dose reductions translated to substantial lowering of the lifetime attributable risk, especially for younger females, and estimated numbers of incident cancers.

Conclusion

Reduction of CT dose is a priority Iterative reconstruction algorithms have the potential to significantly assist with dose reduction across a range of protocols. However, this reduction in dose is achieved via reductions in image noise. Fully realising the potential dose reduction of iterative reconstruction requires the adjustment of image factors and forgoing the noise reduction potential of the iterative algorithm. Our study has demonstrated a reduction in radiation dose for some scanning protocols, but not to the extent experimental studies had previously shown or in all protocols expected, raising questions about the extent to which iterative reconstruction achieves dose reduction in real world clinical practice.  相似文献   

2.

Background

In many developed countries, socioeconomic status is associated with cancer incidence and survival. However, research in Japan is sparse. We examined the association between neighborhood deprivation based on the Japanese Deprivation Index and the risk of incidence, mortality and survival from total and major cancers in the Japan Public Health Center-based Prospective Study.

Methods

86,112 participants were followed through the end of 2009. A total of 10,416 incident cases and 5,510 deaths from cancer were identified among 1,348,437 person-years of follow-up (mean follow-up: 15.7 years). The Japanese deprivation index was used to access neighborhood deprivation. Hazard ratios and 95% confidence intervals were calculated by Cox regression analysis.

Results

We found no associations between neighborhood deprivation index and the incidence of total and major cancers. In some cancer risks or deaths, however, we found positive or inverse associations with a higher deprivation index, such as a decreased risk of colorectal cancer incidence and an increased risk of liver cancer incidence and deaths in women.

Conclusion

Although some positive or inverse associations were detected for specific sites, the neighborhood deprivation index has no substantial overall association with the risk of incidence, mortality and survival from cancer in the Japanese population.  相似文献   

3.

Background

The aims of this study were to investigate the image quality and radiation exposure of pediatric protocols for cardiac CT angiography (CTA) in infants under one year of age.

Methodology/Principal Findings

Cardiac CTA examinations were performed using an anthropomorphic phantom representing a 1-year-old child scanned with non-electrocardiogram-gated (NG), retrospectively electrocardiogram-gated helical (RGH) and prospectively electrocardiogram-gated axial (PGA) techniques in 64-slice and 256-slice CT scanners. The thermoluminescent dosimeters (TLD) were used for direct organ dose measurement, while dose-length product and effective mAs were also used to estimate the patient dose. For image quality, noise and signal-to-noise-ratio (SNR) were assessed based on regions-of-interest drawn on the reconstructed CT images, and were compared with the proposed cardiac image quantum index (CIQI). Estimated dose results were in accordant to the measured doses. The NG scan showed the best image quality in terms of noise and SNR. The PGA scan had better image quality than the RGH scan with 83.70% dose reduction. Noise and SNR were also corresponded to the proposed CIQI.

Conclusions/Significance

The PGA scan protocol was a good choice in balancing radiation exposure and image quality for infant cardiac CTA. We also suggested that the effective mAs and the CIQI were suitable in assessing the tradeoffs between radiation dose and image quality for cardiac CTA in infants. These results are useful for future implementation of dose reduction strategies in pediatric cardiac CTA protocols.  相似文献   

4.
Haukka J  Byrnes G  Boniol M  Autier P 《PloS one》2011,6(9):e22422

Background

Incidence-based mortality modelling comparing the risk of breast cancer death in screened and unscreened women in nine Swedish counties has suggested a 39% risk reduction in women 40 to 69 years old after introduction of mammography screening in the 1980s and 1990s.

Objective

We evaluated changes in breast cancer mortality in the same nine Swedish counties using a model approach based on official Swedish breast cancer mortality statistics, robust to effects of over-diagnosis and treatment changes. Using mortality data from the NordCan database from 1974 until 2003, we estimated the change in breast cancer mortality before and after introduction of mammography screening in at least the 13 years that followed screening start.

Results

Breast mortality decreased by 16% (95% CI: 9 to 22%) in women 40 to 69, and by 11% (95% CI: 2 to 20%) in women 40 to 79 years of age.

Discussion

Without individual data it is impossible to completely separate the effects of improved treatment and health service organisation from that of screening, which would bias our results in favour of screening. There will also be some contamination of post-screening mortality from breast cancer diagnosed prior to screening, beyond our attempts to adjust for delayed benefit. This would bias against screening. However, our estimates from publicly available data suggest considerably lower benefits than estimates based on comparison of screened versus non-screened women.  相似文献   

5.
6.

Background

This study was performed to assess whether iterative reconstruction can reduce radiation dose while maintaining acceptable image quality, and to investigate whether perfusion parameters vary from conventional filtered back projection (FBP) at the low-tube-voltage (80-kVp) during whole-pancreas perfusion examination using a 256-slice CT.

Methods

76 patients with known or suspected pancreatic mass underwent whole-pancreas perfusion by a 256-slice CT. High- and low-tube-voltage CT images were acquired. 120-kVp image data (protocol A) and 80-kVp image data (protocol B) were reconstructed with conventional FBP, and 80-kVp image data were reconstructed with iDose4 (protocol C) iterative reconstruction. The image noise; contrast-to-noise ratio (CNR) relative to muscle for the pancreas, liver, and aorta; and radiation dose of each protocol were assessed quantitatively. Overall image quality was assessed qualitatively. Among 76 patients, 23 were eventually proven to have a normal pancreas. Perfusion parameters of normal pancreas in each protocol including blood volume, blood flow, and permeability-surface area product were measured.

Results

In the quantitative study, protocol C reduced image noise by 36.8% compared to protocol B (P<0.001). Protocol C yielded significantly higher CNR relative to muscle for the aorta, pancreas and liver compared to protocol B (P<0.001), and offered no significant difference compared to protocol A. In the qualitative study, protocols C and A gained similar scores and protocol B gained the lowest score for overall image quality (P<0.001). Mean effective doses were 23.37 mSv for protocol A and 10.81 mSv for protocols B and C. There were no significant differences in the normal pancreas perfusion values among three different protocols.

Conclusion

Low-tube-voltage and iDose4 iterative reconstruction can dramatically decrease the radiation dose with acceptable image quality during whole-pancreas CT perfusion and have no significant impact on the perfusion parameters of normal pancreas compared to the conventional FBP reconstruction using a 256-slice CT scanner.  相似文献   

7.

Background

Diarrhea remains one of the leading causes of morbidity and mortality among children under 5 years of age, but in many low and middle-income countries where vital registration data are lacking, updated estimates with regard to the proportion of deaths attributable to diarrhea are needed.

Methods

We conducted a systematic literature review to identify studies reporting diarrhea proportionate mortality for children 1–59 mo of age published between 1980 and 2009. Using the published proportionate mortality estimates and country level covariates we constructed a logistic regression model to estimate country and regional level proportionate mortality and estimated uncertainty bounds using Monte-Carlo simulations.

Findings

We identified more than 90 verbal autopsy studies from around the world to contribute data to a single-cause model. We estimated diarrhea proportionate mortality for 84 countries in 6 regions and found diarrhea to account for between 10.0% of deaths in the Americas to 31.3% of deaths in the South-east Asian region.

Discussion

Diarrhea remains a leading cause of death for children 1–59 mo of age. Published literature can be used to create a single-cause mortality disease model to estimate mortality for countries lacking vital registration data.  相似文献   

8.

Objectives

To compare the true non-enhanced (TNE) and virtual non-enhanced (VNE) data sets in patients who underwent gastric preoperative dual-energy CT (DECT) and to evaluate potential radiation dose reduction by omitting a TNE scan.

Methods

A total of 74 patients underwent gastric DECT. The mean CT values, length, image quality and effective radiation doses for VNE and TNE images were compared.

Results

There was no statistical difference in maximal thickness of gastric tumors and maximal diameter of enlarged lymph nodes among the TNE and VNE images (P>0.05). The mean CT value differences between TNE and VNE were statistically significant for all tissue types, except for aorta attenuation measurements (P<0.05), but the absolute differences were under 10 HU. Lower noise was found for VNE images than TNE images (P<0.01). Image quality of VNE was diagnostic but lower than that of TNE (P<0.01). The dose reduction achieved by omitting the TNE acquisition was 21.40±4.44%.

Conclusion

VNE scan may potentially replace TNE as part of a multi-phase gastric preoperative staging imaging protocol with consequent saving in radiation dose.  相似文献   

9.

Introduction

The risk of malignancies in patients with rheumatoid arthritis (RA) has raised some concern, particularly with immunosuppressive approaches to disease management.

Methods

We conducted a systematic review of the literature and meta-analysis characterizing the associated risk of overall malignancy and four site-specific malignancies (lymphoma, lung, colorectal, and breast cancer) in patients with RA. A Medline search from 1990 to 2007 was conducted using specified search terms and predefined inclusion criteria for identification of relevant observational studies that provide estimates of relative risk of malignancy associated with RA. Study-specific estimates of the relative risk, as measured by standardized incidence ratios (SIRs) and estimated in comparison with the general population, were combined using a random effects model.

Results

A total of 21 publications were identified, of which 13 reported the SIR for overall malignancy, 14 for lymphoma, 10 for colorectal, 12 for lung, and 9 for breast cancer. Compared with the general population, the overall SIR estimates suggest that RA patients have approximately a two-fold increase in lymphoma risk (SIR 2.08, 95% confidence interval [CI] 1.80 to 2.39) and greater risk of Hodgkin than non-Hodgkin lymphoma. The risk of lung cancer was also increased with an SIR of 1.63 (95% CI 1.43 to 1.87). In contrast, a decrease in risk was observed for colorectal (SIR 0.77, 95% CI 0.65 to 0.90) and breast (SIR 0.84, 95% CI 0.79 to 0.90) cancer. The SIR for overall malignancy was 1.05 (95% CI 1.01 to 1.09).

Conclusion

Patients with RA appear to be at higher risk of lymphoma and lung cancer and potentially decreased risk for colorectal and breast cancer compared with the general population.  相似文献   

10.

Objectives

The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD.

Methods

An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5–12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21–25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software.

Results

The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7%±4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6%±4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists’ sensitivity for detecting solid nodules at all dose levels (5–11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level.

Conclusions

Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.  相似文献   

11.

Aim

To assess the real contribution of modern radiation therapy (RT) technology in the more common tumoral types in Central America, Caribbean and South America.

Background

RT is an essential tool in the management of cancer. RT can be either palliative or of curative intent. In general, for palliative radiotherapy, major technologies are not needed.

Materials and methods

We analyzed the contribution of RT technology based on published evidence for breast, lung, gastric, gallbladder, colorectal, prostate and cervix cancer in terms of disease control, survival or toxicity with especial focus on Latin America.

Results

Findings indicate that three dimensional conformal radiation therapy (3D RT) is the gold standard in most common type of cancer in the studied regions. Prostate cancer is probably the pathology that has more benefits when using new RT technology such as intensity modulated radiation therapy (IMRT) versus 3DRT in terms of toxicity and biochemical progression-free survival.

Conclusions

In light of the changes in technology, the ever-increasing access of developing countries to such technology, and its current coverage in Latin America, any efforts in this area should be aimed at improving the quality of the radiotherapy departments and centers that are already in place.  相似文献   

12.
13.

Background

Whether metformin may affect thyroid cancer risk has not been studied. This study investigated the association between metformin use and thyroid cancer risk in Taiwanese patients with type 2 diabetes mellitus.

Methods

The reimbursement databases of all diabetic patients from 1996 to 2009 were retrieved from the National Health Insurance. An entry date was set at 1 January 2006 and 1,414,723 patients with type 2 diabetes were followed for thyroid cancer incidence until the end of 2009. Incidences for ever-users, never-users and subgroups of metformin exposure using tertile cutoffs for cumulative duration of therapy and cumulative dose were calculated and adjusted hazard ratios were estimated by Cox regression. Additional sensitivity analyses were conducted.

Results

There were 795,321 ever-users and 619,402 never-users, with respective numbers of incident thyroid cancer of 683 (0.09%) and 1,614 (0.26%), and respective incidence of 24.09 and 87.33 per 100,000 person-years. The overall fully adjusted hazard ratio (95% confidence interval) was 0.683 (0.598–0.780), and all categories of the dose-response parameters showed significantly lower risk with P-trends <0.0001. The protective effect of metformin on thyroid cancer incidence was also supported by sensitivity analyses, disregarding age (<50 or ≥50 years) and sex; and was not affected by excluding users of insulin, sulfonylurea, and insulin and/or sulfonylurea respectively, by previous diagnosis of other cancers or by potential detection examinations that might lead to differential diagnosis of thyroid cancer.

Conclusions

This study provides evidence for the first time that metformin use in patients with type 2 diabetes may reduce the risk of thyroid cancer.  相似文献   

14.

Background

Whether human insulin can induce bladder cancer is rarely studied.

Methods

The reimbursement databases of all Taiwanese diabetic patients from 1996 to 2009 were retrieved from the National Health Insurance. An entry date was set at 1 January 2004 and a total of 785,234 patients with type 2 diabetes were followed up for bladder cancer incidence until the end of 2009. Users of pioglitazone were excluded and the period since the initiation of insulin glargine (marketed after the entry date in Taiwan) was not included in the calculation of follow-up. Incidences for ever-users, never-users and subgroups of human insulin exposure (using tertile cutoffs of time since starting insulin, duration of therapy and cumulative dose) were calculated and the hazard ratios were estimated by Cox regression.

Results

There were 87,940 ever-users and 697,294 never-users, with respective numbers of incident bladder cancer of 454 (0.52%) and 3,330 (0.48%), and respective incidence of 120.49 and 94.74 per 100,000 person-years. The overall hazard ratios (95% confidence intervals) indicated a significant association with insulin in the age-sex-adjusted models [1.238 (1.122–1.366)], but not in the model adjusted for all covariates [1.063 (0.951–1.187)]. There was also a significant trend for the hazard ratios for the different categories of the dose-response parameters in the age-sex-adjusted models, which became insignificant when all covariates were adjusted.

Conclusions

This study relieves the concern of a bladder cancer risk associated with human insulin. Appropriate adjustment for confounders is important in the evaluation of cancer risk associated with a medication.  相似文献   

15.

Background

Polymer gel dosimetry has been used extensively in radiation therapy for its capability in depicting a three dimensional view of absorbed dose distribution. However, more studies are required to find less toxic and more efficient polymers for application in radiotherapy dosimetry.

Aim

The purpose of this work was to evaluate the N-isopropyl acrylamide (NIPAM) gel dosimetric characteristics and optimize the protocol for X-ray computed tomography (CT) imaging of gel dosimeters for radiation therapy application.

Material and methods

A polymer gel dosimeter based on NIPAM monomer was prepared and irradiated with 60Co photons. The CT number changes following irradiation were extracted from CT images obtained with different sets of imaging parameters.

Results

The results showed the dose sensitivity of ΔNCT (H) = 0.282 ± 0.018 (H Gy−1) for NIPAM gel dosimeter. The optimized set of imaging exposure parameters was 120 kVp and 200 mA with the 10 mm slice thickness. Results of the depth dose measurement with gel dosimeter showed a great discrepancy with the actual depth dose data.

Conclusion

According to the current study, NIPAM-based gel dosimetry with X-ray CT imaging needs more technical development and formulation refinement to be used for radiation therapy application.  相似文献   

16.

Aim

To establish intensity-modulated radiotherapy (IMRT) planning procedures that spare the corticospinal tract by integrating diffusion tensor tractography into the treatment planning software.

Background

Organs at risk are generally contoured according to the outline of the organ as demonstrated by CT or MRI. But a part of the organ with specific function is difficult to protect, because such functional part of the organ cannot be delineated on CT or conventional sequence of MRI.

Methods

Diagnostic and treatment planning images of glioblastoma patients who had been treated by conventional 3-dimensional conformal radiotherapy were used for re-planning of IMRT. Three-dimensional fiber maps of the corticospinal tracts were created from the diffusion tensors obtained from the patients before the surgery, and were blended with the anatomical MR images (i.e. gadolinium-enhanced T1-weighted images or T2-weighted images). DICOM-formatted blended images were transferred and fused to the planning CT images. Then, IMRT plans were attempted.

Results

The corticospinal tracts could be contoured as organs at risk (OARs), because the blended images contained both anatomical information and fiber-tract maps. Other OARs were contoured in a way similar to that of ordinary IMRT planning. Gross tumor volumes, clinical target volumes, planning target volumes, and other OARs were contoured on the treatment planning software, and IMRT plans were made.

Conclusions

IMRT plans with diminished doses to the corticospinal tract were attained. This technique enabled us to spare specific neuron fibers as OARs which were formerly “invisible” and to reduce the probability of late morbidities.  相似文献   

17.

Aim

The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator.

Background

High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols.

Materials and methods

The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed.

Results

From designed door''s thickness, the door designed by the MC simulation and Wu–McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained.

Conclusion

Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations.  相似文献   

18.

Background

Observational studies suggest an association between tooth loss and risk of head and neck cancer. However, whether tooth loss is an independent risk factor for head and neck cancer still remains controversial. The aim of this study is to assess the association between tooth loss and head and neck cancer risk.

Methods

Eligible studies were searched in PubMed and Embase databases from their inception to March 2013. A random-effects model or fixed-effects model was used to calculate the overall combined risk estimates.

Results

Eight case-control studies and one cross-sectional study involving 5,204 patients and 5,518 controls were included in the meta-analysis. The overall combined odds ratio for tooth loss and head and neck cancer was 2.00 (95% confidence interval, 1.28–3.14). Similar results yielded both in the moderate and severe tooth loss group. Sensitivity analysis based on various exclusion criteria maintained this significance with respect to head and neck cancer individually. Little evidence of publication bias was observed.

Conclusion

This meta-analysis suggests that tooth loss is associated with increased risk of head and neck cancer. This increase is probably independent of conventional head and neck cancer risk factors.  相似文献   

19.

Purpose

The study aims to assess the feasibility of tomotherapy-based image-guided (IGRT) radiotherapy for locally advanced oropharyngeal cancer. A retrospective review of 33 patients undergoing concurrent chemoradiation for locally advanced oropharyngeal cancers was conducted. Radiotherapy planning, treatment toxicity and loco-regional control were assessed.

Results

At a median follow-up of 32 months (6–47 months), no patient developed loco-regional recurrence. Two patients (6%) developed distant metastases. Grade 3–4 acute toxicity was respectively 72% and 25% for mucositis and gastrointestinal toxicity. Two patients (6%) had long-term dependence on tube feedings. Dose-volume histogram demonstrated excellent target volume coverage and low radiation dose to the organs at risk for complications.

Conclusions and clinical relevance

IGRT provides excellent loco-regional control but acute toxicity remains significant and needs to be addressed in future prospective trials. The feasibility of Tomotherapy to decrease radiation dose to the normal tissues merits further investigations.  相似文献   

20.

Background

Thyroid cancer incidence has increased significantly over the past three decades due, in part, to incidental detection. We examined the association between randomization to screening for lung, prostate, colorectal and/or ovarian cancers and thyroid cancer incidence in two large prospective randomized screening trials.

Methods

We assessed the association between randomization to low-dose helical CT scan versus chest x-ray for lung cancer screening and risk of thyroid cancer in the National Lung Screening Trial (NLST). In the Prostate Lung Colorectal and Ovarian Cancer Screening Trial (PLCO), we assessed the association between randomization to regular screening for said cancers versus usual medical care and thyroid cancer risk. Over a median 6 and 11 years of follow-up in NLST and PLCO, respectively, we identified 60 incident and 234 incident thyroid cancer cases. Cox proportional hazards regression was used to calculate the cause specific hazard ratios (HR) and 95% confidence intervals (CI) for thyroid cancer.

Results

In NLST, randomization to lung CT scan was associated with a non-significant increase in thyroid cancer risk (HR  = 1.61; 95% CI: 0.96–2.71). This association was stronger during the first 3 years of follow-up, during which participants were actively screened (HR  = 2.19; 95% CI: 1.07–4.47), but not subsequently (HR  = 1.08; 95% CI: 0.49–2.37). In PLCO, randomization to cancer screening compared with usual care was associated with a significant decrease in thyroid cancer risk for men (HR  = 0.61; 95% CI: 0.49–0.95) but not women (HR  = 0.91; 95% CI: 0.66–1.26). Similar results were observed when restricting to papillary thyroid cancer in both NLST and PLCO.

Conclusion

Our study suggests that certain medical encounters, such as those using low-dose helical CT scan for lung cancer screening, may increase the detection of incidental thyroid cancer.  相似文献   