首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
After 35?years of development, immobilized metal ion affinity chromatography (IMAC) has evolved into a popular protein purification technique. This review starts with a discussion of its mechanism and advantages. It continues with its applications which include the purification of histidine-tagged proteins, natural metal-binding proteins, and antibodies. IMAC used in conjunction with mass spectroscopy for phosphoprotein fractionation and proteomics is also covered. Finally, this review addresses the developments, limitations, and considerations of IMAC in the biopharmaceutical industry.  相似文献   

2.
This article describes the technique of immobilized metal ion affinity chromatography (1MAC). The IMAC stationary phases are designed to chelate certain metal ions that have selectivity for specific groups in peptides and on protein surfaces. The number of stationary phases that can be synthesized for efficient chclation of metal ions is unlimited, but the critical consideration is that there is enough exposure of the metal ion to interact with the proteins, preferably in a biospecific manner. The versatility of IMAC is one of its greatest assets. An important contribution to the correct use of IMAC for protein purification is a simplified presentation of the various sample elution procedures.  相似文献   

3.
金属螯合亲和层析分离蛋白质的研究   总被引:15,自引:2,他引:15  
金属螯合亲和层析是近20年发展起来的一项新型分离技术。它以配基简单、吸附量大、分离条件温和、通用性强等特点,逐渐成为分离纯化蛋白质等生物工程产品最有效的技术之一。本文从单组分蛋白质入手,考查了pH值、铵离子浓度、不同铵盐等对蛋白质洗脱的影响,并进行了分析。还对不同的金属螯合柱和不同性质蛋白质的洗脱性能进行了研究,比较了不同金属离子与蛋白质亲和力的区别,为实际体系的分离研究打下了基础。  相似文献   

4.
Immobilized metal affinity chromatography (IMAC) is widely used for the production of recombinant proteins for a variety of applications; however, a number of challenges are typically encountered by researchers depending on the properties of the specific proteins in question. Here, we describe technical issues we have encountered in production of recombinant zinc finger nucleic acid-binding proteins by IMAC intended for detailed and accurate in vitro analysis. The process encountered leading to a modified IMAC protocol for effective production of high-purity, native zinc finger nucleic acid-binding proteins is described in detail. The parameters with respect to solubility, lysis and redox conditions, removal of residual metal ions with chelating agents, and renaturation in the presence of divalent metal cations are described. These procedures have been extended to production of a wide array of RNA-binding proteins in our laboratory and would be relevant to a number of protein purification applications.  相似文献   

5.
Immobilized metal affinity chromatography (IMAC) is a widely used technique for bioseparation of proteins in general and recombinant proteins with polyhistidine fusion tags in particular. An expensive and critical step in this process is coupling of a chelating ligand to the chromatographic matrix. This chelating ligand coordinates metal ions such as Cu(2+), Zn(2+), and Ni(2+), which in turn bind proteins. The toxicity of chemicals required for coupling and their slow release during the separation process are of considerable concern. This is an important issue in the context of purification of proteins/enzymes which are used in food processing or pharmaceutical purposes. In this work, a simpler IMAC design is described which should lead to a paradigm shift in the application of IMAC in separation. It is shown that zinc alginate beads (formed by chelating alginate with Zn(2+) directly) can be used for IMAC. As "proof of concept", soybean trypsin inhibitor was purified 18-fold from its crude extract with 90% recovery of biological activity. The dynamic binding capacity of the packed bed was 3919 U mL(-1), as determined by frontal analysis. The media could be regenerated with 8 M urea and reused five times without any appreciable loss in its binding capacity.  相似文献   

6.
Arginine hydrochloride (ArgHCl) is a versatile solvent additive, as it suppresses protein aggregation. ArgHCl has been used for protein refolding and to solubilize proteins from loose inclusion bodies. Immobilized metal affinity chromatography (IMAC) is one of the most commonly used technologies for purification of recombinant proteins. Here we have evaluated compatibility of ArgHCl with IMAC purification for his-tag proteins. ArgHCl clearly interfered with protein binding to Ni-columns. Nevertheless, such interference was greatly reduced at ArgHCl concentration below 200 mM, demonstrating that IMAC purification can be done even in the presence of ArgHCl.  相似文献   

7.
Although immobilized metal affinity chromatography (IMAC) offers high capacity and protein selectivity it is not typically used commercially for the capture of native proteins from mammalian cell culture harvest. This is due mainly to the potential for low target recovery due to the presence of strong metal ion chelating species in the harvest that compete for the metal immobilized on the resin. To address this issue a buffer exchange step, such as tangential flow filtration (TFF), is added after harvest clarification and prior to IMAC to remove the interfering harvest components. The addition of a TFF step adds process time and cost and reduces target protein recovery. The elimination of the TFF might make IMAC competitive with other orthogonal methods of protein capture. In this study, we developed a modified IMAC method to allow the direct loading of clarified mammalian harvest without prior buffer exchange (direct IMAC). Although the target enzyme recovery was lower than that from standard IMAC the elimination of the buffer exchange step resulted in a 19% increase in overall enzyme recovery. The target enzyme capacity in direct IMAC was higher, in our experience, than the capacity of hydrophobic interaction (HIC) and ion-exchange (IEX) for protein capture. An economic evaluation of using direct IMAC as a capture step in manufacturing is also discussed.  相似文献   

8.
The complete enzymatic removal of affinity tags from tagged recombinant proteins is often required but can be challenging when slow points for cleavage exist. This study documents a general approach to remove N‐terminal tags from recombinant proteins specifically designed to be efficiently captured by IMAC resins. In particular, site‐directed mutagenesis procedures have been used to modify the amino acid sequence of metal binding tags useful in IMAC purifications of recombinant proteins with the objective to increase cleavage efficiency with the exopeptidase, dipeptidyl aminopeptidase 1. These tags were specifically developed for application with borderline metal ions, such as Ni2+ or Cu2+ ions, chelated to the immobilized ligands, 1,4,7‐triazacyclononane (tacn) and its analogs. Due to the ability to control cleavage site structure and accessibility via site directed mutagenesis methods, these procedures offer considerable scope to obtain recombinant proteins with authentic native N‐termini, thus avoiding any impact on structural stability, humoral and cellular immune responses, or other biological functions. Collectively, these IMAC‐based methods provide a practical alternative to other procedures for the purification of recombinant proteins with tag removal. Overall, this approach is essentially operating as an integrated down‐stream purification capability.  相似文献   

9.
Immobilized metal affinity chromatography (IMAC) is a widely used purification tool for the production of active, soluble recombinant proteins. Escherichia coli proteins that routinely contaminate IMAC purifications have been characterized to date. The work presented here narrows that focus to the most problematic host proteins, those retaining nickel affinity under elevated imidazole conditions, using a single bind-and-elute step. Two-dimensional difference gel electrophoresis, a favored technique for resolving complex protein mixtures and evaluating their expression, here discerns variation in the soluble extract pools that are loaded in IMAC and the remaining contaminants with respect to varied levels of recombinant protein expression. Peptidyl-prolyl isomerase SlyD and catabolite activator protein (CAP) are here shown to be the most persistent contaminants and have greater prevalence at low target protein expression.  相似文献   

10.
Heterologous proteins are frequently purified by immobilized metal ion affinity chromatography (IMAC) based on their modification with a hexa-histidine affinity tag (His-tag). The terminal His-tag can, however, alter functional properties of the tagged protein. Numerous strategies for the tag removal have been developed including chemical treatment and insertion of protease target sequences in the protein sequence. Instead of using these approaches, we took an advantage of natural interaction of zinc finger domains with metal ions to purify functionally similar retroviral proteins from two different retroviruses. We found that these proteins exhibited significantly different affinities to the immobilized metal ions, despite that both contain the same type of zinc finger motif (i.e., CCHC). While zinc finger proteins may differ in biochemical properties, the multitude of IMAC platforms should allow relatively simple yet specific method for their isolation in native state.  相似文献   

11.
It has been proved that the progress of proteomics is mostly determined by the development of advanced and sensitive protein separation technologies. Immobilized metal affinity chromatography (IMAC) is a powerful protein fractionation method used to enrich metal-associated proteins and peptides. In proteomics, IMAC has been widely employed as a prefractionation method to increase the resolution in protein separation. The combination of IMAC with other protein analytical technologies has been successfully utilized to characterize metalloproteome and post-translational modifications. In the near future, newly developed IMAC integrated with other proteomic methods will greatly contribute to the revolution of expression, cell-mapping and structural proteomics.  相似文献   

12.
It has been proved that the progress of proteomics is mostly determined by the development of advanced and sensitive protein separation technologies. Immobilized metal affinity chromatography (IMAC) is a powerful protein fractionation method used to enrich metal-associated proteins and peptides. In proteomics, IMAC has been widely employed as a prefractionation method to increase the resolution in protein separation. The combination of IMAC with other protein analytical technologies has been successfully utilized to characterize metalloproteome and post-translational modifications. In the near future, newly developed IMAC integrated with other proteomic methods will greatly contribute to the revolution of expression, cell-mapping and structural proteomics.  相似文献   

13.
固定化金属螯合亲和膜纯化重组抗菌肽研究   总被引:5,自引:0,他引:5  
用自行制备的固定化金属螯合亲和膜对N端含六个组氨酸标记的重组抗菌肽进行了分离纯化,并较好地解决了金属离子泄露问题.实验表明,固定化金属螯合亲和膜性能优于传统琼脂糖凝胶介质,完全适用于分离纯化含有多组氨酸标记的重组蛋白质.  相似文献   

14.
The selectivity of immobilized metal affinity chromatography (IMAC) systems for the purification of phosphopeptides is poor. This is particularly a problem with tryptic digests of proteins where a large number of acidic peptides are produced that also bind during IMAC. The hypothesis examined in this work was that the selectivity of IMAC columns for phosphopeptides could be increased by using endoproteinase glu-C (glu-C) for protein digestion. Glu-C cleaves proteins at acidic residues and should reduce the number of acidic residues in peptides. This method was successfully applied to a mixture of model proteins and bovine milk. The percentage of phosphorylated peptides selected from proteolytic digests of the milk sample was increased from 40% with trypsin to 70% with glu-C. Additionally, this method was coupled with stable isotope coding methods to quantitatively compare the concentration of phosphoproteins between samples.  相似文献   

15.
Many recombinant proteins carry an oligohistidine (His(X))-tag that allows their purification by immobilized metal affinity chromatography (IMAC). This tag can be exploited for the site-specific attachment of chromophores and fluorophores, using the same metal ion-nitrilotriacetic acid (NTA) coordination chemistry that forms the basis of popular versions of IMAC. Labeling proteins in this way can allow their detection at wavelengths outside of the absorption envelopes of un-modified proteins and nucleic acids. Here we describe use of this technology in tracer sedimentation experiments that can be performed in a standard analytical ultracentrifuge equipped with absorbance or fluorescence optics. Examples include sedimentation velocity in the presence of low molecular weight chromophoric solutes, sedimentation equilibrium in the presence of high concentrations of background protein and selective labeling to simplify the assignment of species in a complex interacting mixture.  相似文献   

16.
Immobilized metal affinity chromatography (IMAC) is widely used for protein purification, e.g., in the isolation of proteins bearing the well-known hexahistidine affinity tag. We report that IMAC matrixes can also adsorb single-stranded nucleic acids through metal ion interactions with aromatic base nitrogens and propose that metal affinity technologies may find widespread application in nucleic acid technology. Oligonucleotide duplexes, plasmid, and genomic DNA show low IMAC binding affinity, while RNA and single-stranded oligonucleotides bind strongly to matrixes such as Cu(II) iminodiacetic acid (IDA) agarose. The affinity of yeast RNA for IDA-chelated metal ions decreases in the following order: Cu(II), Ni(II), Zn(II), and Co(II). Adsorption isotherms for 20-mer oligonucleotide homopolymers show that purines are strongly favored over pyrimidines and that double-stranded duplexes are not bound. IMAC columns have been used to purify plasmid DNA from E. coli alkaline lysates, to purify a ribozyme, to remove primers and imperfect products from PCR reactions, and to separate 20-mer oligonucleotide duplexes containing centered single-base mismatches. Potential further applications include SNP scoring, hybridization assays, and the isolation of polyadenylated messenger RNA.  相似文献   

17.
As part of a study to purify the internal domain of HER2 (ICD) from recombinant expression, through metal immobilised affinity chromatography (IMAC), we encountered a contaminant, SlyD, a 29 kDa native E. coli protein. SlyD is a recurrent contaminant, with a histidine rich domain enabling binding to IMAC columns and thus co-elution with the target protein. Research has been carried out on this protein and its purification, however, no work mentions how to treat it as a true contaminant or describe procedures to isolate it from target proteins. In this report, we described a two-step chromatographic method for the purification of ICD, including IMAC as a capture step and size exclusion chromatography (SEC) as a polishing step. IMAC allowed us to purify ICD from bacterial crude with SlyD co-eluting. SEC then allowed us to resolve ICD from SlyD and achieve a purity greater than 95% for ICD. However, this method has been developed to accommodate any protein whose molecular weight is different enough from SlyD to be separated by SEC.  相似文献   

18.
Immobilized metal ion affinity chromatography (IMAC) is now a widely accepted technique for the purification of natural and recombinant therapeutic products and is beginning to find industrial applications. The design, optimization, and scale-up of a chromatographic process using IMAC demands a thorough understanding to be developed regarding the fundamental factors governing the various interactions between immobilized metal ions and proteins. Consequently, there is an immediate need to find out a theory that is able to account for these interactions most efficiently in a qualitative as well as a quantitative manner. In view of this requirement, the interactions of several model proteins (lysozyme, ovalbumin, bovine serum albumin, conalbumin, and wheat germ agglutinin) with metal (Cu(II), Ni(II))-chelated IDA (iminodiacetate) and tris(2-aminoethyl)amine were investigated. The adsorption data were analyzed using four isotherm models, viz., the general affinity interaction theory/Langmuir model, the Freundlich model, the Temkin model, and the Langmuir-Freundlich model, and the sorption parameters were computed. Although the first three models were applicable to some protein-IMA-M(II) systems, the Langmuir-Freundlich model appeared to be the most efficient model for explaining the interactions of proteins with IMA-M(II) gels. Also, this model was able to explain cooperativity and binding heterogeneity in quantitative terms. It is envisaged that this analysis would be useful in developing an improved understanding of protein-immobilized metal ion interactions and providing guidelines for designing preparative-scale separations using IMAC.  相似文献   

19.
20.
The Center for Eukaryotic Structural Genomics (CESG) has established procedures for the purification of Arabidopsis proteins in a high-throughput mode. Recombinant proteins were fused with (His)(6)-MBP tags at their N-terminus and expressed in Escherichia coli. Using an automated AKTApurifier system, fusion proteins were initially purified by immobilized metal affinity chromatography (IMAC). After cleavage of (His)(6)-MBP tags by TEV protease, (His)(6)-MBP tags were separated from target proteins by a subtractive 2nd IMAC. As a part of quality assurance, all purified proteins were subjected to MALDI-TOF and ESI mass spectrometry to confirm target identity and integrity, and determine incorporation of seleno-methionine (SeMet) and (15)N and (13)C isotopes. The protocols have been used successfully to provide high quality proteins that are suitable for structural studies by X-ray crystallography and NMR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号