首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma has been developed. Sample clean-up prior to chromatographic analysis was accomplished by extraction of the drug using a solid-phase RP-8 or RP-18 cartridge instead of the conventional liquid-liquid extraction methods described. For the separation of the drug from the endogenous components a reversed-phase column (LiChrosorb RP-8) of 5 μm particle size and 250×4 mm I.D., together with a mobile phase consisting of acetonitrile-12 μM perchloric acid (47:53) was selected. The method employs progesterone as an internal standard, and a reversed-phase column combined with UV detection of the drug at 230 nm. The detector response was linear up to the concentration of 400 ng/ml and the average recovery was 100.36%. The sensitivity of the method was 5 ng/ml.  相似文献   

2.
A high-performance liquid chromatographic method has been developed for the determination of penicillin-V concentrations between 0.1 and 19 μg/ml in human plasma. Penicillin-V was isolated from plasma by solid-phase extraction on a C18/OH cartridge. The extracts were injected onto a reversed-phase HPLC system. A 125×4 mm C18 column was used to separate penicillin-V from its main metabolites, 5R- and 5S-penicilloic acid and endogenous compounds. The eluent consisted of 66% 0.02 M phosphoric acid buffer, to which tetrabutylammonium dihydrogenphosphate and 34% acetonitrile were added. The column effluent was monitored by ultraviolet spectrophotometry at 269 nm. Using this method, penicillin-V concentrations in plasma could be determined with an accuracy between −5.4 and 5.2% and a precision between 0.8 and 1.6%. The method has proved to be reliable and was used in biovailability studies for the development of a new oral penicillin-V formulation.  相似文献   

3.
A reversed-phase high-performance liquid chromatographic method for oxazepam in human urine samples has been developed. The sample preparation consists of an enzymatic hydrolysis with β-glucuronidase, followed by a solid-phase extraction process using Bond-Elut C2 cartridges. The mobile phase used was a methanol—water (60:40, v/v) mixture at a flow-rate of 0.50 ml/min. The column was a 3.5 cm × 4.6 mm I.D. C18 reversed-phase column. The detection system was based on a fluorescence post-column derivatization of oxazepam in mixtures of methanol and acetic acid. A linear range from 0.01 to 1 μg/ml of urine and a limit of detection of 4 ng/ml of urine were attained. Within-day recoveries and reproducibilities from urine samples spiked with 0.2 and 0.02 μg/ml oxazepam were 97.9 and 95.0 and 2.1 and 9.4%, respectively.  相似文献   

4.
A method is described for the determination of cortisol in human plasma and urine by high-performance liquid chromatography using fluorophotometric detection. After extraction with methylene chloride, cortisol is labelled with dansyl hydrazine, and then separated by high-performance chromatography. The eluate is monitored by a fluorophotometer at 350 nm (excitation) and 505 nm (emission). The optimum conditions for the determination, such as HCl and dansyl hydrazine concentrations, reaction time and reaction temperature, and for the eluent of high-performance liquid chromatography, are discussed. Linearity of the fluorescence intensity (peak height) with the amount of cortisol was obtained between 0.5 and 60 ng. The recoveries for 50 and 100 ng of added cortisol were 98.7 and 95.4% for plasma, and 96.4 and 90.6% for urine, respectively. Comparison with a radioimmunoassay gave a correlation coefficient of 0.978. The proposed method is suitable for the routine analysis of cortisol in plasma and urine.  相似文献   

5.
A high-performance liquid chromatographic method was developed for the determination of methylguanidine in biological fluids. Methylguanidine and the internal standard were isolated from plasma by cation-exchange solid-phase extraction prior to chromatographic analysis. Urine samples were diluted and injected directly onto the analytical column. Chromatographic separation was carried out on an Ultrasil cation-exchange column using a mixture of methanol and monochloroacetate (15/85, v/v) as the mobile phase. Postcolumn derivatization of methylguanidine was carried out using alkaline ninhydrin reagent and the resulting fluorescent product was detected on-line. The method was specific, sensitive, reproducible, and linear over a wide a range of concentrations. The lower limit of detection for methylguanidine in plasma and urine was 1 and 100 ng/ml, respectively. The method was successfully employed for quantification of the levels of methylguanidine in normal and uremic human subjects, normal dogs, and dogs with ischemic-induced acute or spontaneous chronic renal failure.  相似文献   

6.
A high-performance liquid chromatographic method is described for determination of sub-anaesthetic concentrations of the enantiomers of ketamine and its metabolite norketamine in plasma. The samples are purified by reversed-phase solid-phase extraction. The enantiomers are separated on a Chiral AGP column with a mobile phase containing 16% methanol and a 10 mM phosphate buffer at pH 7.0, and measured by UV-detection at a wavelength of 220 nm. Linear calibration curves with correlation coefficients better than 0.995 have been obtained in the range 10–320 ng/ml. Minimum detectable concentrations were about 2 ng/ml.  相似文献   

7.
As a part of a pilot clinical study, a high-performance reversed-phase liquid chromatography analysis was developed to quantify temozolomide in plasma and urine of patients undergoing a chemotherapy cycle with temozolomide. All samples were immediately stabilized with 1 M HCl (1 + 10 of biological sample), frozen and stored at −20°C prior to analysis. The clean-up procedure involved a solid-phase extraction (SPE) of clinical sample (100 μl) on a 100-mg C18-endcapped cartridge. Matrix components were eliminated with 750 μl of 0.5% acetic acid (AcOH). Temozolomide was subsequently eluted with 1250 μl of methanol (MeOH). The resulting eluate was evaporated under nitrogen at RT and reconstituted in 200 μl of 0.5% AcOH and subjected to HPLC analysis on an ODS-column (MeOH-0.5% AcOH, 10:90) with UV detection at 330 nm. The calibration curves were linear over the concentration range 0.4–20 μg/ml and 2–150 μg/ml for plasma and urine, respectively. THe extraction recovery of temozolomide was 86–90% from plasma and 103–105% from urine over the range of concentrations considered. The stability of temozolomide was studied in vitro in buffered solutions at RT, and in plasma and urine at 37°C. An acidic pH (<5–6) shoul be maintained throughout the collection, the processing and the analysis of the sample to preserve the integrity of the drug. The method reported here was validated for use in a clinical study of temozolomide for the treatment of metastatic melanoma and high grade glioma.  相似文献   

8.
A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20–2000 ng/ml. The recovery of busulfan from plasma standards was 70±5%. The detection and quantification limits for busulfan in plasma samples were established at 9 ng/ml and 20 ng/ml, respectively. The intra- and inter-assay variations were lower than 8% and 10%, respectively. The applicability of the method was verified by analyzing the plasma concentrations of busulfan in a patient to whom it was administered orally on two different days.  相似文献   

9.
A simple and highly sensitive high-performance liquid chromatographic method for the direct determination of urinary glucuronide conjugates is described. The method is based on the direct derivatization of the glucuronic acid moiety in glucuronide conjugates with 6,7-dimethoxy-1-methyl-2 (1 H)-quinoxalinone-3-propionylcarboxylic acid hydrazide. The derivatization reaction proceeds in aqueous solution in the presence of pyridine and 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide at 0–37°C. The resulting fluorescent derivatives are separated on a C18 column using methanol—acetonitrile—0.5% triethylamine in water (1:1:2, v/v) as mobile phase, and are detected spectrofluorimetrically at 445 nm with excitation at 367 nm. The detection limits (signal-to-noise RATIO = 3) for the glucuronides are 13–48 fmol for an injection volume of 10 μl (130–480 fmol per 5 μl of human urine). The method was applied to the measurement of etiocholanorone-3-glucuronide and androsterone-3-glucuronide in human urine. The method is simple and rapid without conventional liquid—liquid extraction of the glucuronides from urine.  相似文献   

10.
A new method for determining cycloserine in plasma samples is described. This method is based on the derivatization of cycloserine with p-benzoquinone, a reaction that takes place at the same time as the process of plasma deproteinization due to the presence of ethanol as solvent in the solution of the derivatization reagent. Four derivatives are obtained from this reaction. The main derivative is well correlated with the cycloserine concentration. The ratio between the volumes of the plasma sample and the reagent solution is 1:2 for a p-benzoquinone concentration of 1000 μg/mL. Elution from a C18 column was isocratic, using a mobile phase containing (v/v) 85% aqueous 0.1% formic acid solution, and 15% (v/v) of a mixture of methanol and acetonitrile (1:1), with a flow-rate of 1 mL/min, at 25°C. Determinations by fluorescence detection were achieved with excitation at 381 nm and emission at 450 nm, with a detection limit of 10 ng/mL for an injection volume of 5 μL. This method was validated and applied to the determination of cycloserine in blood plasma samples of several healthy volunteers.  相似文献   

11.
The role of the Mg2+ cation on antihypertensive molecule binding on human serum albumin (HSA) was studied by affinity chromatography. The thermodynamic data corresponding to this binding were determined for a wide range of Mg2+ concentrations (c). For the nifedipine molecule, an increase in the Mg2+ concentration produced a decrease in binding due to a decrease in the electrostatic interactions. For verapamil and diltiazem, which have the highest solvent accessible surface area, the solute binding on HSA was divided into two Mg2+ concentration regions. For a low c value below c(c) (approximately 1.6 mmol/l), the binding dependence with c was similar to that of nifedipine. For c above c(c) the hydrophobic effect created in the bulk solvent associated with a decrease in the van der Waals interactions between the solute molecule and the HSA implied a decrease in its binding. These results showed that for patients with hypertension, an Mg2+ supplementation during treatment with these antihypertensive molecules can increase the active pharmacological molecule concentration.  相似文献   

12.
Severe homocystinemia is frequently associated with vascular disease while the pathological consequences of moderate or slightly elevated plasma homocysteine are unknown. Cobalamin and folate deficiencies may result in an elevation of plasma homocysteine. A sensitive and reproducible assay for total plasma homocysteine has been developed. The essential steps in the assay include (i) conversion of homocysteine disulfides to free homocysteine with borohydride reduction; (ii) conjugation of homocysteine with monobromobimane; (iii) separation of homocysteine-bimane from other plasma thiol-bimane adducts by reverse-phase high-performance liquid chromatography; and (iv) detection and quantitation of homocysteine-bimane by fluorometry. The method has a sensitivity of 4.4 pmol of homocysteine and is highly reproducible (intra- and interassay coefficients of variation = 4.97 and 4.53%, respectively). The mean concentration of total plasma homocysteine in nonfasting adult males (n = 12) and females (n = 12) was 15.8 (range, 7.0-23.7) and 16.5 nmol/ml (range, 8.6-20.7), respectively. Markedly elevated levels of homocysteine were found in patients with cobalamin and folate deficiency. Total plasma homocysteine represents approximately 4% of borohydride-generated thiol reactivity in the plasma of normal individuals.  相似文献   

13.
A new HPLC assay using UV detection (200 nm) was developed to determine ethambutol (EMB) concentrations in plasma. Following extraction (0.1 ml plasma) with chloroform, EMB and octylamine (used as internal standard) were derivatized with phenylethylisocyanate. Quantitation in plasma was achieved at 200 nm. There were no interferences from endogenous compounds. Intra- and inter-day variabilities were lower than 5.2 and 7.6%, respectively. The limit of quantitation of the method was 0.2 μg/ml. In plasma, ethambutol was found to be stable for at least one month when samples were stored at −20°C. This assay was applied to the therapeutic monitoring of EMB concentrations in 19 patients suffering from tuberculosis.  相似文献   

14.
15.
A solid-phase extraction (SPE) method has been developed for the isolation of melanotan II from rabbit urine. The proposed extraction method makes it possible to selectively isolate melanotan II without significant loss of the peptide. Standard curves obtained from high-performance liquid chromatographic (HPLC) analysis of spiked urine extracts are linear from 0.1 to 4.0 μg/ml. The analytical method is shown to be highly reproducible, giving a relative standard deviation of less than 5% for both between-day and same-day analyses. The accuracy of the method obtained from standard plots ranges from −3.3 to 3.1%.  相似文献   

16.
An improved high-performance liquid chromatographic method has been developed to measure human plasma concentrations of the analgesic nonsteroidal anti-inflammatory drug ketorolac for use in pharmacokinetic studies. Samples were prepared for analysis by solid-phase extraction using Bond-Elut PH columns, with nearly complete recovery of both ketorolac and the internal standard tolmetin. The two compounds were separated on a Radial-Pak C18 column using a mobile phase consisting of water–acetonitrile–1.0 mol/l dibutylamine phosphate (pH 2.5) (30:20:1) and detected at a UV wavelength of 313 nm. Using only 250 μl of plasma, the standard curve was linear from 0.05 to 10.0 μg/ml.  相似文献   

17.
A method using high-performance liquid chromatography (HPLC) and solid-phase extraction (SPE) is described for the determination of ginsenoside Rg3 in human plasma. A 2.5-ml volume of plasma was mixed with 2.5 ml 60% methanol aqueous solution, and centrifuged at 1100 g for 10 min, the supernatant fluid was further purified by SPE with 200 mg/5 ml 40 μm octadecyl silica and separation was obtained using a reversed-phase column under isocratic conditions with ultraviolet absorbance detection. The intra- and inter-day precision, determined as relative standard deviations, were less than 5.0%, and method recovery was more than 97%. The lower limit of quantitation, based on standards with acceptable RSDs, was 2.5 ng/ml. No endogenous compounds were found to interfere with analyte. A good linear relationship with a regression coefficient of 0.9999 in the range of 2.5 to 200 ng/ml was observed. This method has been demonstrated to be suitable for pharmacokinetic studies in humans. Method development for determination of drug with low UV absorption by SPE and HPLC is also discussed.  相似文献   

18.
A new, simple and rapid high-performance liquid chromatography (HPLC) method with UV detection has been developed for the determination of apovincaminic acid in human plasma. Apovincaminic acid and internal standard were isolated from plasma samples by solid-phase extraction with OASIS HLB cartridges. The chromatographic separation was accomplished on a reversed-phase C(18) column and UV detection was set at 311 nm. The calibration curves were linear in the concentration range of 2.4-240.0 ng/ml, and the limits of quantification was 2.4 ng/ml. The precision and accuracy ranged from 0.84 to 8.54% and 91.5 to 108.3%, respectively. The developed method was subsequently applied to study the pharmacokinetics of apovincaminic acid in a group of 20 human subjects at a single oral dose of 10mg of vinpocetine tablet.  相似文献   

19.
A rapid, sensitive and robust sample preparation procedure for the quantitative determination of indinavir in human cerebrospinal fluid (CSF) and plasma is described. Indinavir and the internal standard were isolated from CSF or plasma samples by cation-exchange solid-phase extraction with SCX cartridges, while the chromatographic separation was adopted from a previous method, using a cyano column connected by a switching valve to a C18 column. UV detection was set at 210 nm. The standard curve was linear over the concentration range of 2 to 2000 ng/ml in CSF and 5 to 2000 ng/ml in plasma. The intra-day coefficients of variation at all concentration levels were ≤5.9%. The inter-day consistency was assessed by running QC samples during each daily run. The coefficients of variation for quality control samples in both matrixes were ≤6.1%. The method has been utilized to support clinical pharmacokinetic studies.  相似文献   

20.
Sumatriptan succinate (the analyte) and naloxone (the internal standard) were extracted from plasma with a solid-phase extraction technique. Chromatography and detection were performed by isocratic reversed-phase high-performance liquid chromatography with coulometric end-point detection. The standard curve was linear over the range 0–100 ng/ml of sumatriptan succinate in plasma. The reproducibility (as defined by the coefficient of variation, C.V.) over the range of the standard curve was 4.9–7.3%. The recovery averaged 83%. The sensitivity was 0.25 ng of sumatriptan on column (allowing a concentration of 0.5 ng/ml to be determined from a 1-ml plasma sample volume). Plasma profiles of the analyte following subcutaneous (s.c.) administration in eight normal male volunteers, are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏