首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
AIMS: The lack of baseline data on the prevalence of Escherichia coli O157:H7 in retail minced beef in France prompted this survey of industrial minced beef production. METHODS AND RESULTS: An automated enzyme-linked fluorescence immunoassay (ELFA), the VIDAS E. coli O157 method, was used to detect E. coli O157 in industrial minced beef samples. Confirmation of samples positive according to the ELFA was performed using an automated immunoconcentration (ICE) system, VIDAS ICE, which allows the selective capture and release of target organisms. The ICE was followed by culture on cefixime tellurite sorbitol MacConkey agar and a chromogenic medium, O157:H7 ID. Of the 3450 minced beef samples tested, 175 samples were positive with the ELFA method and, of these, four were confirmed by the ICE method. They were identified as sorbitol-negative, O157-positive, H7-positive, mobile, verotoxin-producing E. coli. CONCLUSIONS: The prevalence of E. coli O157:H7 in industrial French minced beef was 0.12%, consistent with many other reports. SIGNIFICANCE AND IMPACT OF THE STUDY: The low infective dose of E. coli O157:H7 presents a major threat. The main means of combating this organism are thermal destruction and good food hygiene covering activities on-farm, in the abattoir and in minced beef industries.  相似文献   

2.
AIMS: To assess the detection and recovery rates achieved with commonly used cultural methods for the enumeration and recovery of Escherichia coli O157:H7 from minced beef and bovine hide. METHODS AND RESULTS: Minced beef and bovine hide were inoculated with varying concentrations (log(10) 1.58-2.58 CFU g(-1) and log(10) 2.42-4.49 CFU 100 cm(2) respectively) of E. coli O157:H7 and recovered using a direct plate method or an enrichment/immunomagnetic separation (IMS) method and then plated onto SMAC or SMAC-CT in both cases. The direct plate method detected the pathogen consistently from minced beef samples with an average recovery of 69.2-91.2%. From faecal material on the bovine hide the recovery of the pathogen ranged from 1.80 to 64.5% with fresh faeces depending on the inocula while from dried faeces on hide the results ranged from no recovery at all to 25.1%. Enrichment/IMS recovered E. coli O157:H7 at all inocula levels tested in minced beef while the pathogen was only detected consistently at an average inocula level of log(10) 2.73 CFU 100 cm(2) from fresh faeces and log(10) 4.49 CFU 100 cm(2) from dried faeces on bovine hide. CONCLUSIONS: The direct count enumeration method for E. coli O157:H7 underestimated the numbers of pathogens present. The enrichment/IMS procedure consistently detected the pathogen from minced beef but did not always detect E. coli O157:H7 from faeces on bovine hide. SIGNIFICANCE AND IMPACT OF THE STUDY: Overall this study highlights that any microbial data, used in either predictive microbiology or risk assessment, must take account of the sensitivity and associated performance of the methods employed, in order to make an accurate reflection of the true microbiology of the examined sample.  相似文献   

3.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

4.
This study has evaluated enrichment and detection procedures for the isolation and detection of Escherichia coli O157 inoculated into minced beef. The use of a 24 h enrichment in modified EC broth containing novobiocin allowed low numbers of contaminating cells to multiply to levels detectable on culture media and by ELISA test kits. Total analysis time was reduced by the use of the DynabeadTM immunomagnetic separation system. The use of the PetrifilmTM Test Kit-HEC for E. coli O157: H7 and Organon Teknika EHEC-TEK system detected low numbers of contaminating cells following enrichment and reduced analysis time by 1 d. The incorporation of cefixime and tellurite into Sorbitol MacConkey Agar increased the rate and ease of isolation of E. coli O157 and its use is therefore recommended.  相似文献   

5.
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples.  相似文献   

6.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

7.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

8.
Two 5'nuclease-based PCR methods (PCR-LS-50B and PCR-7200) were evaluated to determine their sensitivity for detecting Escherichia coli O157:H7 from pure cultures and in food samples enriched in different media and after different incubation periods. The PCR-7200 method was able to detect E. coli O157:H7 at ± 102 CFU/mL in pure culture in both mECB and EEB. In spiked meat samples, the PCR-7200 procedure was capable of detecting the eaeA gene at lower concentrations than the PCR-LS-50B procedure, regardless of the meat type or enrichment medium. Escherichia coli O157:H7 spiked at 0.3 CFU/mL was detectable after 9 h in EEB, but it was not detected in mECB within 24 h. An enrichment time of 4 h in mECB was needed to detect E. coli O157:H7 when spiked at higher levels (41 CFU/mL). The detection levels reported in this study are similar with other reported PCR-based detection techniques for E. coli O157:H7, however, the 5'nuclease-based assays are less labor intensive and capable of higher sample throughput because of their automated detection and analysis steps.  相似文献   

9.
AIM: To develop an improved, rapid and sensitive sample preparation method for PCR-based detection of Escherichia coli O157:H7 in ground beef. METHODS AND RESULTS: Fresh ground beef samples were experimentally inoculated with varying concentrations of E. coli O157:H7. PCR inhibitors were removed and bacterial cells were concentrated by filtration and centrifugation, and lysed using enzymatic digestion and successive freeze/thaw cycles. DNA was purified and concentrated via phenol/chloroform extraction and the Shiga toxin 1 gene (stx1) was amplified using PCR to evaluate the sample preparation method. Without prior enrichment of cells in broth media, the detection limit was 103 CFU g-1 beef. When a 6 h enrichment step was incorporated, the detection limit was 1 CFU g-1 beef. The total time required from beginning to end of the procedure was 12 h. CONCLUSIONS: The sample preparation method developed here enabled substantially improved sensitivity in the PCR-based detection of E. coli O157:H7 in ground beef, as compared to previous reports. SIGNIFICANCE AND IMPACT OF THE STUDY: Superb sensitivity, coupled with quick turn-around time, relative ease of use and cost-effectiveness, makes this a useful method for detecting E. coli O157:H7 in ground beef.  相似文献   

10.
Antibody to Escherichia coli O157 lipopolysaccharide was detected in the sera of healthy individuals more frequently in Southern Thailand than in Japan. The result suggested possible exposure of Thai people to E. coli O157. E. coli O157:H7 or O157:H(-) was isolated from four of 95 retail beef and one of 55 bovine feces samples collected in Southern Thailand by enrichment culture followed by immunomagnetic bead separation. Four of the five strains carried the stx(2) gene alone or in combination with the stx(1) gene. The strains were shown to be genetically distinct by an arbitrarily primed PCR method.  相似文献   

11.
AIM: To develop a real-time PCR detection procedure for Escherichia coli O111, O26 and O157 from minced meat. METHODS AND RESULTS: Strains (n = 8) of each of E. coli O26, E. coli O111 and E. coli O157 were inoculated at ca 10-20 CFU g(-1) into minced retail meat and enriched for 6 h at 41.5 degrees C as follows: E. coli O26 in tryptone soya broth (TSB) supplemented with cefixime (50 microg l(-1)), vancomycin (40 mg l(-1)) and potassium tellurite (2.5 mg l(-1)); E. coli O111 in TSB supplemented with cefixime (50 microg l(-1)) and vancomycin (40 mg l(-1)); E. coli O157 in E. coli broth supplemented with novobiocin (20 mg l(-1)). DNA was extracted from the enriched cultures, and detected and quantified by real-time PCR using verotoxin (vt1 and vt2) and serogroup (O157 per gene; O26 fliC-fliA genes and O111 wzy gene) specific primers. CONCLUSIONS: The methods outlined were found to be sensitive and specific for the routine detection of E. coli O111, O26 and O157 in minced beef. SIGNIFICANCE AND IMPACT OF THE STUDY: The enrichment, isolation and detection procedures used in this study provide a rapid routine-based molecular method for the detection and differentiation of E. coli O26, O111 and O157 from minced meat.  相似文献   

12.
AIMS: The aims of this study were (i) to evaluate the specificity and sensitivity of three previously described PCR assays for the detection of E. coli O157 and, (ii) to compare PCR, culture, and two visual immunoassays (VIAs), BioSign and Path-Stik, for detecting E. coli O157 after enrichment culture and immunomagnetic separation (IMS) performed on various naturally contaminated raw beef, lamb and mixed meat products. METHODS AND RESULTS: Twelve sorbitol non fermenting (SNF) verocytotoxin-producing (VT+) E. coli O157, 6 SNF VT- E. coli O157, 4 sorbitol fermenting (SF) VT+ E. coli O157, 3 SF VT- E. coli O157, 23 E. coli belonging to 17 other serogroups and 12 organisms of other species were used to check the specificity of PCR reactions. Only one primer pair generated amplimers only with E. coli O157 and was used for all subsequent work. After enrichment culture and on inoculated minced beef samples, PCR was as sensitive as culture for detecting 9 of the 12 strains of E. coli O157, but up to 4 log10 more sensitive than culture for detecting three strains. Of the 120 samples of naturally contaminated meat products examined, 80 (67%) were positive by PCR, 70 (58%) were positive by BioSign, 69 (58%) were positive by culture and 67 (56%) were positive by Path-Stik. Eleven samples were positive by PCR and both VIAs, but negative by culture because culture plates were heavily overgrown with SF organisms making detection of any E. coli O157 present impossible. CONCLUSIONS: PCR and both VIAs compared well with culture of beads to CT-SMAC for detecting E. coli O157 after enrichment culture and IMS. PCR appeared to be the most sensitive method, but needed specialised equipment and was also the most expensive, laborious and technically demanding technique. Although lacking the sensitivity of PCR, the VIAs were of comparable sensitivity to culture and were extremely quick and easy to perform giving a result in less than 15 minutes. SIGNIFICANCE AND IMPACT OF THE STUDY: Culture techniques may fail to detect E. coli O157 retrieved by IMS due to overgrowth with other organisms.  相似文献   

13.
Sensitivities of direct plate culture (DPC) method, immunomagnetic separation (IMS) method, and polymerase chain reaction (PCR) assay for successful detection Escherichia coli O157 in the food samples were compared. Three lots of minced beef and three lots of radish sprout, both of which were commercially retailed, were enriched with non-selective broth media at 36 degrees C for 6 h. After enrichment, the cultures of the minced beef and those of the radish sprout were found to have background microflora at ca.10(5)-10(7) CFU/ml and ca.10(8) CFU/ml, respectively. The cultures were then experimentally inoculated with E. coli O157 strains at various final concentrations ranging from ca.10 to 10(7) CFU/ml. The samples thus prepared were subjected to the above three methods to evaluate their detection limits. For the samples of minced beef, the detection limits of the DPC method was 10(2) CFU/ml whilst that of the IMS method was ca.10 CFU/ml. For the samples of radish sprout, the detection limits of the DPC method, the IMS method, and the PCR assay were ca.10(4) CFU/ml, ca.10(2) CFU/ml, and ca.10(6) CFU/ml, respectively. There results strongly suggest that the IMS method is most sensitive method for the detection of O157 from food samples among the methods currently available.  相似文献   

14.
A commercially available real-time, rapid PCR test was evaluated for its ability to detect Escherichia coli O157. Both the sensitivity and specificity of the assay were 99% for isolates in pure culture. The assay detected 1 CFU of E. coli O157:H7 g(-1) in artificially inoculated bovine feces following enrichment.  相似文献   

15.
A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be detected within 16 h, including incubation for 12 h in enrichment broth and the immunoassay, which takes 4 h. Pure culture cell suspensions of 10(5) or 10(6) E. coli O157:H7 organisms per ml produced intense color reactions in the immunoassay, whereas faint but detectable reactions occurred with 10(3) CFU/ml. The sensitivity of the combined enrichment-immunoassay procedure as determined by using ground beef inoculated with E. coli O157:H7 was 0.1 to 1.3 cells per g, with a false-positive rate of 2.0%. A survey of retail ground beef using this procedure revealed that 1 of 76 samples was contaminated by E. coli O157:H7.  相似文献   

16.
A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be detected within 16 h, including incubation for 12 h in enrichment broth and the immunoassay, which takes 4 h. Pure culture cell suspensions of 10(5) or 10(6) E. coli O157:H7 organisms per ml produced intense color reactions in the immunoassay, whereas faint but detectable reactions occurred with 10(3) CFU/ml. The sensitivity of the combined enrichment-immunoassay procedure as determined by using ground beef inoculated with E. coli O157:H7 was 0.1 to 1.3 cells per g, with a false-positive rate of 2.0%. A survey of retail ground beef using this procedure revealed that 1 of 76 samples was contaminated by E. coli O157:H7.  相似文献   

17.
Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.  相似文献   

18.
The purpose of this study was to apply our rapid, integrated double enrichment 5' nuclease real-time polymerase chain reaction assay for the detection of Escherichia coli O157:H7 and evaluate its efficacy. The assay targeted ground beef, an important vehicle in disease epidemiology. The assay reliably determined in 8 h the presence of E. coli O157:H7 in ground beef at the level of 1 colony-forming unit (CFU)/g. The sensitivity and specificity of the assay were compared with that of standard enrichment diagnostic techniques. A correlation of 100% in detection was achieved to the limit of 1 CFU/g. This assay can be used as a rapid, automatic process for identification of E. coli O157:H7 in ground beef or can be integrated with standard culture procedures, resulting in considerable cost and time savings.  相似文献   

19.
The simultaneous growth of Escherichia coli O157:H7 (O157) and the ground beef background microflora (BM) was described in order to characterize the effects of enrichment factors on the growth of these organisms. The different enrichment factors studied were basal medium (Trypticase soy broth and E. coli broth), the presence of novobiocin in the broth, and the incubation temperature (37 degrees C or 40 degrees C). BM and O157 kinetics were simultaneously fitted by using a competitive growth model. The simple competition between the two microfloras implied that O157 growth stopped as soon as the maximal bacterial density in the BM was reached. The present study shows that the enrichment protocol factors had little impact on the simultaneous growth of BM and O157. The selective factors (i.e., bile salts and novobiocin) and the higher incubation temperature (40 degrees C) did not inhibit BM growth, and incubation at 40 degrees C only slightly improved O157 growth. The results also emphasize that when the level of O157 contamination in ground beef is low, the 6-h enrichment step recommended in the immunomagnetic separation protocol (ISO EN 16654) is not sufficient to detect O157 by screening methods. In this case, prior enrichment for approximately 10 h appears to be the optimal duration for enrichment. However, more experiments must be carried out with ground beef packaged in different ways in order to confirm the results obtained in the present study for non-vacuum- and non-modified-atmosphere-packed ground beef.  相似文献   

20.
The goal of this study was to develop a sensitive, specific, and accurate method for the selective detection of viable Escherichia coli O157:H7 cells in foods. A unique open reading frame (ORF), Z3276, was identified as a specific genetic marker for the detection of E. coli O157:H7. We developed a real-time PCR assay with primers and probe targeting ORF Z3276 and confirmed that this assay was sensitive and specific for E. coli O157:H7 strains (n = 298). Using this assay, we can detect amounts of genomic DNA of E. coli O157:H7 as low as a few CFU equivalents. Moreover, we have developed a new propidium monoazide (PMA)-real-time PCR protocol that allows for the clear differentiation of viable from dead cells. In addition, the protocol was adapted to a 96-well plate format for easy and consistent handling of a large number of samples. Amplification of DNA from PMA-treated dead cells was almost completely inhibited, in contrast to the virtually unaffected amplification of DNA from PMA-treated viable cells. With beef spiked simultaneously with 8 × 10(7) dead cells/g and 80 CFU viable cells/g, we were able to selectively detect viable E. coli O157:H7 cells with an 8-h enrichment. In conclusion, this PMA-real-time PCR assay offers a sensitive and specific means to selectively detect viable E. coli O157:H7 cells in spiked beef. It also has the potential for high-throughput selective detection of viable E. coli O157:H7 cells in other food matrices and, thus, will have an impact on the accurate microbiological and epidemiological monitoring of food safety and environmental sources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号