首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

2.
A system is described that uses an oscillating magnetic field to produce power-frequency electric fields with strengths in excess of those produced in an animal or human standing under a high-voltage electric-power transmission line. In contrast to other types of exposure systems capable of generating fields of this size, no electrodes are placed in the conducting growth media: the possibility of electrode contamination of the exposed suspension is thereby eliminated. Electric fields in the range 0.02–3.5 V/m can be produced in a cell culture with total harmonic distortions less than 1.5%. The magnetic field used to produce electric fields for exposure is largely confined within a closed ferromagnetic circuit, and experimental and control cells are exposed to leakage magnetic flux densities less than 5 μT. The temperatures of the experimental and control cell suspensions are held fixed within ±0.1°C by a water bath. Special chambers were developed to hold cell cultures during exposure and sham exposure. Chinese hamster ovary (CHO) cells incubated in these chambers grew for at least 48 h and had population doubling times of 16–17 h, approximately the same as for CHO cells grown under standard cell-culture conditions.  相似文献   

3.
This investigation studied the effect of 50 Hz electric and magnetic fields on the human heart. The electrocardiograms of 27 transmission-line workers and 26 male volunteers were recorded with a Holter recorder both in and outside the fields. The measurements took from half an hour to a few hours. The electric field strength varied from 0.14 to 10.21 kV/m and the magnetic flux density from 1.02 to 15.43 μT. Analysis of the ECG recordings showed that extrasystoles or arrhythmias were as frequent outside the field as in the field. In some cases a small decrease in heart rate was observed after field exposure. © 1993 Wiley-Liss, Inc.  相似文献   

4.
Many in vitro experiments on the biological effects of extremely low frequency (ELF) electromagnetic fields utilize a uniform external magnetic flux density (B) to expose biological materials. A significant number of researchers do not measure or estimate the resulting electric field strength (E) or current density (J) in the sample medium. The magnitude and spatial distribution of the induced E field are highly dependent on the sample geometry and its relative orientation with respect to the magnetic field. We have studied the E fields induced in several of the most frequently used laboratory culture dishes and flasks under various exposure conditions. Measurements and calculations of the E field distributions in the aqueous sample volume in the containers were performed, and a set of simple, quantitative tables was developed. These tables allow a biological researcher to determine, in a straightforward fashion, the magnitudes and distributions of the electric fields that are induced in the aqueous sample when it is subjected to a uniform, sinusoidal magnetic field of known strength and frequency. In addition, we present a novel exposure technique based on a standard organ culture dish containing two circular, concentric annular rings. Exposure of the organ culture dish to a uniform magnetic field induces different average electric fields in the liquid medium in the inner and outer rings. Results of experiments with this system, which were reported in a separate paper, have shown the dominant role of the magnetically induced E field in producing specific biological effects on cells, in vitro. These results emphasize the need to report data about the induced E field in ELF in-vitro studies, involving magnetic field exposures. Our data tables on E and J in standard containers provide simple means to enable determination of these parameters.  相似文献   

5.
We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 microT rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m rms and the induced electric field was 1.9 V/m rms. The temperature was maintained at 36.5 +/- 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 microT rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 microT rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.  相似文献   

6.
The expected imminent widespread use of electromobility in transport systems draws attention to the possible effects of human exposure to magnetic fields generated inside electric vehicles and during their recharge. The current trend is to increase the capacity of the battery inside the vehicles to extend the available driving range and to increase the power of recharging columns to reduce the time required for a full recharge. This leads to higher currents and potentially stronger magnetic fields. The Interoperability Center of the Joint Research Center started an experimental activity focused on the assessment of low-frequency magnetic fields emitted by five fast-charging devices available on the market in recharge and standby conditions. The aim of this study was to contribute to the development of a standard measurement procedure for the assessment of magnetic fields emitted by direct current charging columns. The spectrum and amplitudes of the magnetic field, as well as exposure indices according to guidelines for the general public and occupational exposure, were recorded by means of a magnetic field probe analyzer. The worst-case scenario for instantaneous physical direct and indirect effects was identified. Measurements within the frequency range of 25 Hz–2 kHz revealed localized magnetic flux density peaks above 100 μT at the 50 Hz frequency in three out of five chargers, registered in close proximity during the recharge. Beyond this distance, exposure indices were recorded showing values below 50% of reference levels. Bioelectromagnetics. 2020;41:308–317 © 2020 The Authors. Bioelectromagnetics published by Wiley Periodicals, Inc.  相似文献   

7.
Electrosurgical units (ESUs) commonly used in operating suites employ radiofrequency (RF) energy for cutting and coagulation, and operate at different frequencies in the range 0.3–5 MHz. Around the electrode and cables, electric and magnetic fields at similar frequencies will be generated, and the surgeon using the ESU will therefore be exposed to these electromagnetic fields. In this study we have measured the levels of RF fields near the lead wires of two electrosurgical units, BARD 3000 operating at a fixed frequency of 0.5 MHz, and ERBE ICC 350 with a frequency range from 0.3 to 1 MHz. Electric fields were measured at distances from 5–30 cm from the lead wire. Measurements were done with the ESU both cutting and coagulating, and power levels ranging from 10–100 W. The magnetic field outside the lead wire was calculated from the measured current through the leads using standard theory. Using those measurements as a base, the calculated local exposure of the surgeon's hand was estimated to exceed 15 kV/m for the electric field and the corresponding value for the magnetic field was 16 µT. These calculations exceed the suggested international reference levels at 0.5 MHz (610 V/m and 4 µT, respectively).  相似文献   

8.
Work in our laboratory has revealed autonomic and/or behavioral sensitivity of mice, rats, and a domestic fowl to extremely-low-frequency (ELF) or nominally static magnetic (B) fields at flux densities between 250 and 1700 μT (rms). To extend our work, an automated exposure and data-acquisition system was used with the technique of conditional suppression to assess behavioral sensitivity to time-varying B fields. Each of five rats was exposed aperiodically to a B field during 3 min warning periods that terminated in a brief electric shock. The difference between rates of lever pressing during B-field warning periods and rates during immediately antecedent, 3 min control periods was analyzed at frequencies of 7, 16, 30, 60, and 65.1 Hz. To produce equivalent induced voltages in the rat at each frequency, graded flux densities were established that ranged from 1900 μT at 7 Hz to 200 μT at 65.1 Hz. Analysis of differences in lever-pressing rates revealed that in a given session of testing the rats would increasingly suppress responding when exposed to a B field, but this trend was independent of frequency. This experiment provides evidence of behavioral sensitivity by a mammal to an ELF magnetic field. © 1994 Wiley-Liss, Inc.  相似文献   

9.
In occupational environments, an increasing number of electromagnetic sources emitting complex magnetic field waveforms in the range of intermediate frequencies is present, requiring an accurate exposure risk assessment with both in vitro and in vivo experiments. In this article, an in vitro exposure system able to generate complex magnetic flux density B‐fields, reproducing signals from actual intermediate frequency sources such as magnetic resonance imaging (MRI) scanners, for instance, is developed and validated. The system consists of a magnetic field generation system and an exposure apparatus realized with a couple of square coils. A wide homogeneity (99.9%) volume of 210 × 210 × 110 mm3 was obtained within the coils, with the possibility of simultaneous exposure of a large number of standard Petri dishes. The system is able to process any numerical input sequence through a filtering technique aimed at compensating the coils' impedance effect. The B‐field, measured in proximity to a 1.5 T MRI bore during a typical examination, was excellently reproduced (cross‐correlation index of 0.99). Thus, it confirms the ability of the proposed setup to accurately simulate complex waveforms in the intermediate frequency band. Suitable field levels were also attained. Moreover, a dosimetry index based on the weighted‐peak method was evaluated considering the induced E‐field on a Petri dish exposed to the reproduced complex B‐field. The weighted‐peak index was equal to 0.028 for the induced E‐field, indicating an exposure level compliant with the basic restrictions of the International Commission on Non‐Ionizing Radiation Protection. Bioelectromagnetics 34:211–219, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

10.
An exposure chamber was designed to study the effects of electric and magnetic fields (EMF) on oestrous cycles, hormonal profile during gestation, pineal function, quantity and quality of milk production, feed intake, and central nervous system of dairy cattle. The chamber was 15 x 10 x 3 m; and the control system was fully computerized so that the field intensities can be varied and monitored continuously, on site or remotely. During exposure to EMF, milk production, feed consumption, and health were monitored closely and blood and cerebral spinal fluid were continuously sampled. The chamber characteristics allow use of a wide range of exposure such as electric fields (0-30 kV/m) and magnetic fields (0-100 microT) at frequencies ranging from 45 to 3000 Hz.  相似文献   

11.
A numerical model of a human body with an intramedullary nail in the femur was built to evaluate the effects of the implant on the current density distribution in extremely low frequency electric and magnetic fields. The intramedullary nail was chosen because it is one of the longest high conductive implants used in the human body. As such it is expected to alter the electric and magnetic fields significantly. The exposure was a simultaneous combination of inferior to superior electric field and posterior to anterior magnetic field both alternating at 50 Hz with the values corresponding to the ICNIRP reference levels: 5000 V m?1 for electric field and 100 µT for magnetic flux density. The calculated current density distribution inside the model was compared to the ICNIRP basic restrictions for general public (2 mA m?2). The results show that the implant significantly increases the current density up to 9.5 mA m?2 in the region where it is in contact with soft tissue in the model with the implant in comparison to 0.9 mA m?2 in the model without the implant. As demonstrated the ICNIRP basic restrictions are exceeded in a limited volume of the tissue in spite of the compliance with the ICNIRP reference levels for general public, meaning that the existing safety limits do not necessarily protect implanted persons to the same extent as they protect people without implants. Bioelectromagnetics 30:591–599, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

12.
In order to run a series of in vitro studies on the effect of extremely low-frequency magnetic fields on cell cultures, developing and characterizing an appropriate exposure system is required. The present design is based on a two-shielded Lee-Whiting coils system. The circular design was chosen because its axial symmetry allowed for both reducing simulation unknowns and measurement points during the characterization, and additionally made the machining of the parts easier. The system can generate magnetic flux densities (B fields) up to 1 mT root-mean-square amplitude (rms) with no active cooling system in the incubator, and up to 3 mTrms with it. The double-wrapped windings with twisted pairs allow for the use of each set of coils either as exposure or control with no detectable parasitic B field in the control. The artifacts have also been analyzed; the B field in the center of the sham control chamber is about 1 µTrms for a maximum of 3 mTrms in the exposure chamber, the parasitic incident electric fields are less than 1 V/m, the temperature difference between sham and exposure chamber is less than or equal to 0.2 °C, and the typical vibration difference between sham and exposure is less than 0.1 m/s2. © 2020 Bioelectromagnetics Society.  相似文献   

13.
The occupational exposure to electric and magnetic fields during various work tasks at seven 110 kV substations in Finland's Tampere region was studied. The aim was to investigate if the action values (10 kV/m for the E‐field and 500 µT for the B‐field) of the EU Directive 2004/40/EC were exceeded. Electric and magnetic fields were measured during the following work tasks: (1) walking or operating devices on the ground; (2) working from a service platform; (3) working around the power transformer on the ground or using a ladder; and (4) changing a bulb from a man hoist. In work task 2 “working from a service platform” the measured electric field (maximum value 16.6 kV/m) exceeded 10 kV/m in three cases. In the future it is important to study if the limit value (10 mA/m2) of Directive 2004/40/EC is exceeded at 110 kV substations. The occupational 500 µT action value of the magnetic flux density field (B‐field) was not exceeded in any working situation. Bioelectromagnetics 31:252–254, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
To address the effect of extremely low frequency electromagnetic fields on programmed cell death we assessed both the spontaneous and dexamethasone (Dex)-induced apoptosis of thymocytes and spleen cells from mice submitted to a long-term continuous exposure of a 0.4–1.0 μT 60 Hz magnetic field or an 8–20 μT direct current (DC) magnetic field. Dex-induced apoptosis but not spontaneous apoptosis was substantially increased in thymocytes from 0.4 to 1.0 μT 60 Hz field-exposed animals. Spontaneous apoptosis and Dex-induced apoptosis of spleen cells were not affected by the 0.4–1.0 μT 60 Hz field exposure. In addition, spontaneous apoptosis and Dex-induced apoptosis of thymocytes and spleen cells from mice exposed to an 8–20 μT DC field were similar to the controls. These findings represent the first demonstration that thymocytes from mice exposed to a long-term 0.4–1.0 μT 60 Hz field may show abnormal response to Dex apoptotic stimuli. Bioelectromagnetics 19:131–135, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

15.
Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring internal electric fields. The calibration constant for the probe size was 5.7 mm, with a flat response from at least 12 Hz to 20 kHz. A cardiac signal, similar to the normal electrocardiogram with a heart rate of about 250 bpm, was readily obtained at the chest. Upon analysis of its spectrum, the cardiac field detected by the probe had a broad maximum at 32–95 Hz. When the rats were exposed to a 1 mT, 60 Hz magnetic field, a spike appeared in the spectrum at 60 Hz. The peak-to-peak magnitudes of electric fields associated with normal heart function were comparable to fields induced by a 1 mT magnetic field at 60 Hz for those positions measured on the body surface (where induced fields were maximal). Within the body, or in different directions relative to the applied field, the induced fields were reduced (reaching zero at the center of the animal). The cardiac field increased near the heart, becoming much larger than the induced field. Thus, the cardiac electric field, together with the other endogenous fields, combine with induced electric fields and help to provide reference levels for the induced-field dosimetry of ELF magnetic field exposures of living animals. Bioelectromagnetics 18:317–323, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

16.
Although extremely low frequency (ELF) magnetic fields (<300 Hz) appear to exert a variety of biological effects, the magnetic field sensing/transduction mechanism(s) remains to be established. Here, using the inhibitory effects of magnetic fields on endogenous opioid peptide-mediated “analgaesic” response of the land snail. Cepaea nemoralis, we addressed the mechanism(s) of action of ELF magnetic fields. Indirect mechanisms involving both induced electric fields and direct magnetic field detection mechanisms (e.g., magnetite, parametric resonance) were evaluated. Snails were exposed to a static magnetic field (BDC=78±1 μT) and to a 60 Hz magnetic field (BAC=299±1 μT peak) with the angle between the static and 60 Hz magnetic fields varied in eight steps between 0° and 90°. At 0° and 90°, the magnetic field reduced opioid-induced analgaesia by approximately 20%, and this inhibition was increased to a maximum of 50% when the angle was between 50° and 70°. Because BAC was fixed in amplitude, direction, and frequency, any induced electric currents would be constant independent of the BAC/BDC angle. Also, an energy transduction mechanism involving magnetite should show greatest sensitivity at 90°. Therefore, the energy transduction mechanism probably does not involve induced electric currents or magnetite. Rather, our results suggest a direct magnetic field detection mechanism consistent with the parametric resonance model proposed by Lednev. © 1996 Wiley-Liss, Inc.  相似文献   

17.
The development of scientifically sound instrumentation, methods, and procedures for the electromagnetic exposure assessment of compact fluorescent lamps (CFLs) is investigated. The incident and induced fields from 11 CFLs have been measured in the 10 kHz–1 MHz range, and they are compared with the levels for incandescent and light emitting diode (LED) bulbs. Commercially available equipment was used to measure the incident fields, while a novel sensor was built to assess the induced fields in humans. Incident electric field levels significantly exceed the International Commission on Non‐Ionizing Radiation Protection (ICNIRP) reference levels at close distances for some sources, while the induced fields are within the ICNIRP basic restrictions. This demonstrates the importance of assessing the induced fields rather than the incident fields for these sources. Maximum current densities for CFLs are comparable to the limits (in the range of 9% to 56%), demonstrating the need for measurements to establish compliance. For the frequency range investigated, the induced fields were found to be considerably higher for CFLs than for incandescent light bulbs, while the exposure from the two LED bulbs was low. The proposed instrumentation and methods offer several advantages over an existing measurement standard, and the measurement uncertainty is significantly better than the assessment of electric and magnetic fields at close distances. Bioelectromagnetics 33:166–175, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

18.
Sixteen multiparous nonpregnant lactating Holstein cows (each weighing 662 ± 65 kg in 150.4 ±40 day of lactation) were confined to wooden metabolic cages with 12:12 h light:dark cycle during the experiment. The cows were divided into two sequences of eight cows each and exposed to electric and magnetic fields (EMF) in an exposure chamber. This chamber produced a vertical electric field of 10 kV/m and a uniform horizontal magnetic field of 30 μT at 60 Hz. One sequence was exposed for three estrous cycles of 24 to 27 days. During the first estrous cycle, the electric and magnetic fields were off; during the second estrous cycle, they were on; and during the third estrous cycle, they were off. The second sequence was also exposed for three 24 to 26 days estrous cycles, but the exposure to the fields was reversed (first estrous cycle, on; second estrous cycle, off; third estrous cycle, on). The length of each exposure period (21 to 27 days) varied according to the estrous cycle length. No differences were detected in plasma progesterone concentrations and area under the progesterone curve during estrous cycles between EMF nonexposed and exposed periods (2.28 ±0.17 and 2.25 ± 0.17; and 24.5 ± 1.9 vs. 26.4 ± 1.9 ng/ml, respectively). However, estrous cycle length, determined by the presence of a functional corpus luteum detected by concentrations of progesterone equal to or more than 1 ng/ml plasma, was shorter in nonexposed cows than when they were exposed to EMF (22.0 ± 0.9 vs. 25.3 ± 1.4 days). Bioelectromagnetics 19:438–443, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

19.
This study demonstrates that exposure to 60 Hz magnetic fields (3.4–8.8 mT) and magnetic fields over the range DC-600 kHz (2.5–6.5 mT) can alter the early embryonic development of sea urchin embryos by inducing alterations in the timing of the cell cycle. Batches of fertilized eggs were exposed to the fields produced by a coil system. Samples of the continuous cultures were taken and scored for cell division. The times of both the first and second cell divisions were advanced by ELF AC fields and by static fields. The magnitude of the 60 Hz effect appears proportional to the field strength over the range tested. The relationship to field frequency was nonlinear and complex. For certain frequencies above the ELF range, the exposure resulted in a delay of the onset of mitosis. The advance of mitosis was also dependent on the duration of exposure and on the timing of exposure relative to fertilization. © 1995 Wiley-Liss, Inc.  相似文献   

20.
The effects of static and 50 Hz magnetic fields on cytochrome-C oxidase activity were investigated in vitro by strictly controlled, simultaneous polarographic measurements of the enzyme's high- and low-affinity redox reaction. Cytochrome-C oxidase was isolated from beef heart. Control experiments were carried out in the ambient geomagnetic and 50 Hz magnetic fields at respective flux densities of 45 and 1.8 μT. The experimentally applied fields, static and time-varying, were generated by Helmholtz coils at flux densities between 50 μT and 100 mT. Exposures were timed to act either on the combined enzyme-substrate interchange or directly on the enzyme's electron and proton translo-cations. Significant changes as high as 90% of the overall cytochrome-C oxidase activity resulted during exposure (1) to a static magnetic field at 300 μT or 10 mT in the high-affinity range, and (2) to a 50 Hz magnetic field at 10 or 50 mT in the low-affinity range. No changes were observed at other flux densities. After exposure to a change-inducing, static or time-varying field, normal activity returned. © 1993 Wiley-Liss. Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏