首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Measurements of the velocity and energy spectra were made in the distal region of modeled stenoses in a rigid tube with both steady and pulsatile water flows. Reynolds numbers of 318–2540 and a pulsatile flow frequency parameter of 15 were employed. The effects of the degree of stenosis, the stenosis geometry and the presence or absence of the downstream confining wall on the development of flow disturbances were investigated. Visualization of the distal flow patterns in stenotic and free jets illustrated the existence of complex fields which included vortex shedding, highly turbulent regions, and recirculation zones. Significant flow disorder was created by a mild stenosis in pulsatile, but not in steady, flow. Nondimensionalization employing the stenosis diameter and flow velocity in the throat of the constriction correlates the vortex shedding frequency and energy spectra within a limited postestenotic region.  相似文献   

2.
Hemodynamics have long been implicated in atherogenesis. The studiesreported here seek to explain the mechanisms for the formation ofatherosclerotic plaque in an aortic bifurcation. Flow studies were made ina model constructed from plexiglass to represent an aortic bifurcation. Under steady flow conditions at inflow Reynolds numbers of 80–1250,the streamline flow patterns and the boundary layer separation zones wereinvestigated in relation to the location of atherosclerotic plaques clinicallyfound at regions in the human aortic bifurcation. The streamline flowswere visualized by a slow injection of dye over the cross section of the tubeentrance and along the tube walls. The studies revealed a complex flowfield where secondary flows, induced by the centrifugal and viscous forces,cause the fluid to move towards the inner walls of the aortic bifurcation. The effect was more clearly seen with increasing Reynolds number. Boundary layer separation zones were observed to occur at the outercorners of the branching. The nature of the separation zone formed wasfound to be dependent on Reynolds number. The residence time of fluidparticles within such a separation zone was estimated by measuring thewashout time of a bolus of dye injected at strategic locations along the tubewalls. The residence time was found to decrease exponentially withincreasing Reynolds number. These observations provide strong support forthe role of flow separation in the accumulation of LDL and plateletaggregation within the aortic bifurcation.  相似文献   

3.
In this study fluid dynamic variables are analysed numerically in different human carotid artery bifurcation models in order to clarify the geometric factor in carotid bifurcation atherogenesis. The geometric variations describe healthy human carotid bifurcation anatomy and concern the shape of the carotid sinus and the angle between the branches. The flow conditions remain unchanged. The governing Navier-Stokes equations describing incompressible, pulsatile, three-dimensional viscous flow are approximated using a pressure correction finite element procedure which has been developed for time-consuming, three-dimensional, time-dependent viscous flow problems. The study concentrates on flow velocity, on detailed analysis of flow separation and flow recirculation, and on wall shear stress distribution. The results show that the extension and the location of the recirculation zone in the sinus as well as the duration of separated flow during the pulse cycle are affected by the geometrical variations. In view of the significance of the reversed flow zones and of the accompanied low shear regions in atherogenesis the geometry-dependent flow separation characteristics in the sinus is of substantial interest.  相似文献   

4.
The complex nature of blood flow in the human arterial system is still gaining more attention, as it has become clear that cardiovascular diseases localize in regions of complex geometry and complex flow fields. In this article, we demonstrate that the lattice Boltzmann method can serve as a mesoscopic computational hemodynamic solver. We argue that it may have benefits over the traditional Navier-Stokes techniques. The accuracy of the method is tested by studying time-dependent systolic flow in a 3D straight rigid tube at typical hemodynamic Reynolds and Womersley numbers as an unsteady flow benchmark. Simulation results of steady and unsteady flow in a model of the human aortic bifurcation reconstructed from magnetic resonance angiography, are presented as a typical hemodynamic application.  相似文献   

5.
D Liepsch  M Singh  M Lee 《Biorheology》1992,29(4):419-431
We studied the flow behavior under steady flow conditions in four models of cylindrical stenoses at Reynolds numbers from 150 to 920. The flow upstream of the constrictions was always fully developed. The constriction ratios of the rigid tubes (D) to the stenoses (d) were d/D = 0.273; 0.505; 0.548; 0.786. The pressure drop at various locations in the stenotic models was measured with water manometers. The flow was visualized with a photoelasticity apparatus using an aqueous birefringent solution. We also studied the flow behavior at pulsatile flow in a dog aorta with a constriction of 71%. The flow through stenotic geometries depends on the Reynolds number of the flow generated in the tube and the constriction ratio d/D. At low d/D ratios, (with the increased constriction), the flow separation zones (recirculation zones, so-called reattachment length) and flow disturbances increased with larger Reynolds numbers. At lower values, eddies were generated. At high Re, eddies were observed in the pre-stenotic regions. The pressure drop is a function of the length and internal diameter of the stenosis, respective ratio of stenosis to the main vessel and the Reynolds numbers. At low Re-numbers and low d/D, distinct recirculation zones were found close to the stenosis. The flow is laminar in the distal areas. Further experiments under steady and unsteady flow conditions in a dog aorta model with a constriction of 71% showed similar effects. High velocity fluctuations downstream of the stenosis were found in the dog aorta. A videotape demonstrates these results.  相似文献   

6.
Under normal healthy conditions, blood flow in the carotid artery bifurcation is laminar. However, in the presence of a stenosis, the flow can become turbulent at the higher Reynolds numbers during systole. There is growing consensus that the transitional k-omega model is the best suited Reynolds averaged turbulence model for such flows. Further confirmation of this opinion is presented here by a comparison with the RNG k-epsilon model for the flow through a straight, nonbifurcating tube. Unlike similar validation studies elsewhere, no assumptions are made about the inlet profile since the full length of the experimental tube is simulated. Additionally, variations in the inflow turbulence quantities are shown to have no noticeable affect on downstream turbulence intensity, turbulent viscosity, or velocity in the k-epsilon model, whereas the velocity profiles in the transitional k-omega model show some differences due to large variations in the downstream turbulence quantities. Following this validation study, the transitional k-omega model is applied in a three-dimensional parametrically defined computer model of the carotid artery bifurcation in which the sinus bulb is manipulated to produce mild, moderate, and severe stenosis. The parametric geometry definition facilitates a powerful means for investigating the effect of local shape variation while keeping the global shape fixed. While turbulence levels are generally low in all cases considered, the mild stenosis model produces higher levels of turbulent viscosity and this is linked to relatively high values of turbulent kinetic energy and low values of the specific dissipation rate. The severe stenosis model displays stronger recirculation in the flow field with higher values of vorticity, helicity, and negative wall shear stress. The mild and moderate stenosis configurations produce similar lower levels of vorticity and helicity.  相似文献   

7.
The oscillatory shear index (OSI) was developed based on the hypothesis that intimal hyperplasia was correlated with oscillatory shear stresses. However, the validity of the OSI was in question since the correlation between intimal thickness and the OSI at the side walls of the sinus in the Y-shaped model of the average human carotid bifurcation (Y-AHCB) was weak. The objectives of this paper are to examine whether the reason for the weak correlation lies in the deviation in geometry of Y-AHCB from real human carotid bifurcation, and whether this correlation is clearly improved in the tuning-fork-shaped model of the average human carotid bifurcation (TF-AHCB). The geometry of the TF-AHCB model was based on observation and statistical analysis of specimens from 74 cadavers. The flow fields in both models were studied and compared by using flow visualization methods under steady flow conditions and by using laser Doppler anemometer (LDA) under pulsatile flow conditions. The TF-shaped geometry leads to a more complex flow field than the Y-shaped geometry. This added complexity includes strengthened helical movements in the sinus, new flow separation zone, and directional changes in the secondary flow patterns. The results show that the OSI-values at the side walls of the sinus in the TF-shaped model were more than two times as large as those in the Y-shaped model. This study confirmed the stronger correlation between the OSI and intimal thickness in the tuning-fork geometry of human carotid bifurcation, and the TF-AHCB model is a significant improvement over the traditional Y-shaped model.  相似文献   

8.
Secondary velocity fields in the conducting airways of the human lung   总被引:1,自引:0,他引:1  
An understanding of flow and dispersion in the human respiratory airways is necessary to assess the toxicological impact of inhaled particulate matter as well as to optimize the design of inhalable pharmaceutical aerosols and their delivery systems. Secondary flows affect dispersion in the lung by mixing solute in the lumen cross section. The goal of this study is to measure and interpret these secondary velocity fields using in vitro lung models. Particle image velocimetry experiments were conducted in a three-generational, anatomically accurate model of the conducting region of the lung. Inspiration and expiration flows were examined under steady and oscillatory flow conditions. Results illustrate secondary flow fields as a function of flow direction, Reynolds number, axial location with respect to the bifurcation junction, generation, branch, phase in the oscillatory cycle, and Womersley number. Critical Dean number for the formation of secondary vortices in the airways, as well as the strength and development length of secondary flow, is characterized. The normalized secondary velocity magnitude was similar on inspiration and expiration and did not vary appreciably with generation or branch. Oscillatory flow fields were not significantly different from corresponding steady flow fields up to a Womersley number of 1 and no instabilities related to shear were detected on flow reversal. These observations were qualitatively interpreted with respect to the simple streaming, augmented dispersion, and steady streaming convective dispersion mechanisms.  相似文献   

9.
The relationship between blood flow and the localization of thrombosis and atherosclerosis in vivo was investigated using the approach and techniques of microrheology. The flow patterns and wall-adhesion of platelets were studied in the captive annular vortex formed at a sudden tubular expansion at various hematocrits in steady and pulsatile flow. The adhesion density exhibited a peak within the vortex and just downstream of the reattachment point, which is also a stagnation point. The peaks flattened out with increasing Reynolds number in steady flow and also in pulsatile flow. Platelet adhesion increased markedly with increasing hematocrit. The localization of adhesion peaks was explained by curvature of the streamlines carrying platelets to the wall on either side of the reattachment point. The relevance of these results to the circulation is that stagnation points are found in regions of disturbed flow at various sites in the arterial and venous circulations. This was shown in experiments using a technique whereby flow was visualized in isolated transparent natural blood vessels prepared from dogs and humans postmortem. In dog saphenous vein bileaflet valves, there was a large primary spiral vortex as well as a smaller secondary vortex, the latter acting as a trap and generator of thrombi. Recirculation zones also existed in the dog aorta at T-junctions of the celiac, cranial mesenteric and renal arteries. Finally, in the human carotid bifurcation, a large standing recirculation zone consisting of spiral secondary flows formed in the carotid sinus at physiological flow conditions.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
The results of computational simulations may supplement MR and other in vivo diagnostic techniques to provide an accurate picture of the hemodynamics in particular vessels, which may help demonstrate the risks of embolism or plaque rupture posed by particular plaque deposits. In this study, a model based on an endarterectomy specimen of the plaque in a carotid bifurcation was examined. The flow conditions include steady flow at Reynolds numbers of 300, 600, and 900 as well as unsteady pulsatile flow. Both dynamic pressure and wall shear stress are very high, with shear values up to 70 N/m2, proximal to the stenosis throat in the internal carotid artery, and both vary significantly through the flow cycle. The wall shear stress gradient is also strong along the throat. Vortex shedding is observed downstream of the most severe occlusion. Two turbulence models, the Chien and Goldberg varieties of k-epsilon, are tested and evaluated for their relevance in this geometry. The Chien model better captures phenomena such as vortex shedding. The flow distal to stenosis is likely transitional, so a model that captures both laminar and turbulent behavior is needed.  相似文献   

11.
Considering transient two-dimensional laminar flow in a diseased carotid artery segment with realistic inlet and outflow conditions, detailed velocity profiles, pressure fields, wall shear stress distributions and coupled, localized plaque formations have been simulated. The type of outflow boundary condition influences to a certain degree the extent of plaque build-up, which in turn reduces "disturbed flow" phenomena such as flow separations, recirculation zones, and wavy flow patterns in the artery branches during portions of the pulse. Based on computer experiments varying key geometric factors, a plaque-mitigating design of a carotid artery bifurcation has been proposed. Elimination of the carotid bulb, a smaller bifurcation angle, lower area ratios, and smooth wall curvatures generated a design with favorable hemodynamics parameters, leading to reduced plaque build-up by factors of 10 and 2 in the internal carotid and in the external carotid, respectively.  相似文献   

12.
Fluid flow and plaque formation in an aortic bifurcation   总被引:1,自引:0,他引:1  
Considering steady laminar flow in a two-dimensional symmetric branching channel with local occlusions, a finite element model has been developed to study velocity fields including reverse flow regions, pressure profiles and wall shear stress distributions for different Reynolds numbers, bifurcation angles and lumen reductions. The flow analysis has been extended to include a new submodel for the pseudo-transient formation of plaque at sites and deposition rates defined by the physical characteristics of the flow. Specifically, simulating the onset of atherosclerotic lesions, sinusoidal plaque layers have been placed in areas of critically low wall shear stresses, and simulating the growth of particle depositions, plaque layers have been added in a stepwise fashion in regions of critically high and low shear. Thus two somewhat conflicting hypothetical correlations between critical wall shear stress levels and atheroma have been tested and a solution has been postulated. The validated computer simulation model is a predictive tool for analyzing the effects of local changes in wall curvature due to surgical reconstruction and/or atherosclerotic lesions, and for investigating the design of aortic bifurcations which mitigate plaque formation.  相似文献   

13.
Visualization experiments were performed to elucidate the complicated flow pattern in pulsatile flow through arterial bifurcations. Human common carotid arteries, which were made transparent, and glass-models simulating Y- and T-shaped bifurcations were used. Pulsatile flow with wave forms similar to those of arterial flow was generated with a piston pump, elastic tube, airchamber, and valves controlling the outflow resistance. Helically recirculating flow with a pattern similar to that of the horseshoe vortex produced around wall-based protuberances in circular tubes was observed in pulsatile flow through all the bifurcations used in the present study. This flow type, which we shall refer to as the horseshoe vortex, has also been demonstrated to occur at the human common carotid bifurcation in steady flow with Reynolds numbers above 100. Time-varying flows also produced the horseshoe vortex mostly during the decelerating phase. Fluid particles of dye solution approaching the bifurcation apex diverged, divided into two directions perpendicularly, and then showed helical motion representing the horseshoe vortex formation. While this helical flow was produced, the stagnation points appeared on the wall upstream of the apex. Their position was dependent upon the flow distribution ratio between the branches in the individual arteries. The region affected by the horseshoe vortex was smaller during pulsatile flow than during steady flow. Lowering the Reynolds number together with the Womersley number weakened the intensity of helical flow. A separation bubble, resulting from the divergence or wall roughness, was observed at the outer or inner wall of the branch vessels and made the flow more complicated.  相似文献   

14.
S Moravec  D Liepsch 《Biorheology》1983,20(6):745-759
Together with biochemical factors, fluid mechanical factors play a role in atherogenesis and the deposition of blood platelets at bends and bifurcations in human arteries. Hence, flow patterns were investigated in a simplified 3-dimensional model of a human renal artery bifurcation using Newtonian (aqueous glycerol) and non-Newtonian (aqueous solution of polyacrylamide) fluids. Studies were carried out in steady as well as pulsatile flow at inflow Reynolds numbers of 498 and 951 with flow rate ratios main tube V1: right branch V4: left branch V3 of 1: 0.25: 0.25 and 1: 0.18: 0.18 respectively. The velocity distribution proximal and distal to the bifurcations was measured using a laser-Doppler anemometer. In steady flow, zones of flow separation and reverse flow were observed distal to the bifurcations. In pulsatile flow using non-Newtonian fluids, there was a significant enlargement of these zones. Differences between the Newtonian and non-Newtonian fluids occurred especially distal to the bifurcations. Shear stresses along all measuring positions were computed from the velocity gradients.  相似文献   

15.
A method is described for construction of an in vitro flow model based on in vivo measurements of the lumen geometry of the human carotid bifurcation. A large-scale physical model of the vessel lumen was constructed using fused deposition modeling (a rapid prototyping technique) based on magnetic resonance (MR) images of the carotid bifurcation acquired in a healthy volunteer. The lumen negative was then used to construct a flow model for experimental studies that examined the hemodynamic environment of subject-specific geometry and flow conditions. The physical model also supplements physician insight into the three-dimensional geometry of the arterial segment, complementing the two-dimensional images obtained by MR. Study of the specific geometry and flow conditions in patients with vascular disease may contribute to our understanding of the relationship between their hemodvnamic environment and conditions that lead to the development and progression of arterial disease.  相似文献   

16.
Many cardiovascular lesions such as aneurysms, intimal cushions, and atherosclerotic plaques tend to occur near bifurcations. This suggests that hemodynamic factors may be involved. Since measuring devices (such as anemometers) are still too large to allow local measurements of flow disturbances, we have attempted to predict the nature of these factors mathematically. Biological variables include pulsatile flow of a nonNewtonian fluid in distensible branching vessels with different angles and flow rates. Our initial analysis considers the flow in a two-dimensional bifurcation with a symmetrical flow divider perfused with steady flow at variable Reynolds numbers. At all flows, high shear forces develop on either side of the flow divider (i.e. at the apex of the bifurcation). With high flows, regions of sluggish or reverse flow develop near the outer walls of the bifurcation. The analysis confirms that the flow at the apex is quite different from that at the outer angles and that the latter varies more with flow rate than the former.  相似文献   

17.
Velocity and pressure fields, streamlines and wall shear stress distributions were numerically obtained for two-dimensional, steady and pulsatile flow in a carotid artery segment. Distinct regions of reverse flow near the bifurcation and wavy flow patterns in the branching channels were observed during portions of the pulse. These phenomena disappear at the end of the systolic phase of the cardiac cycle. A previously validated plaque formation model predicts that plaque sites and the local extent of atherosclerotic lesions are similar for those present on human angiograms.  相似文献   

18.
Carotid geometry effects on blood flow and on risk for vascular disease   总被引:2,自引:0,他引:2  
It has been widely observed that atherosclerotic diseases occur at sites with complex hemodynamics, such as artery bifurcations, junctions, and regions of high curvature. These regions usually have very low or highly oscillatory wall shear stress (WSS). In the present work, 3D pulsatile blood flow through a model of the carotid artery bifurcation was simulated using a finite volume numerical method. The goal was to quantify the risk of atherogenesis associated with different carotid artery geometries. A risk scale based on the average WSS on the sinus wall of the internal carotid artery was proposed-a scale that can be used to quantify the effect of the carotid geometry on the relative risk for developing vascular disease. It was found that the bifurcation angle and the out-of-plane angle of the internal carotid artery affect the formation of low stress regions on the carotid walls. The main conclusions are: (a) larger internal carotid artery angles (theta(IC)) generally increase the frequency and the area of blood recirculation and lower the WSS on the sinus wall, hence increasing the risk of plaque build-up; (b) off-plane angles were found to lower the WSS on the sinus for geometries with theta(IC)25 degrees . Larger off-plane angles generally increase the danger of plague build-up; (c) for theta(IC) < 25 degrees , the off-plane angle does not have an obvious effect on the hemodynamic WSS; (d) symmetric bifurcations were found to increase the WSS on the sinus wall and ease the risk of vascular disease.  相似文献   

19.
The velocity field around arterial stenoses was investigated using a pulsed doppler velocimeter in vivo. Asymmetric zones of recirculation were identified by systolic flow reversal in the post-stenotic field in carotid and iliac arteries of anesthetised dogs. There was a close correlation between shear intensity and turbulence as estimated by the velocity difference between the jet and the recirculation zone and by maximum spectral width respectively. Under the conditions of these experiments, stenosis grade (% diameter reduction) dominated hemodynamic variables such as Reynolds number, oscillation and pulsatility in determining the intensity of turbulence. The method used does not appear to have sufficient resolution to distinguish between turbulence and discrete oscillating velocities (vorticity) nor to allow determination of wall shear stress though the pattern of change of the latter is similar to that found downstream of axisymmetric stenosis in models using steady flow.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号