首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sanitation in self-service automatic washers.   总被引:2,自引:1,他引:1       下载免费PDF全文
The potential for microbial transfer in self-service laundry washing machines was investigated by obtaining swab samples from the interior surfaces of commercial machines and wash water samples before and after disinfectant treatment. Three disinfectants (chlorine, a quaternary ammonium product, and a phenolic disinfectant) were used. Four self-service laundry facilities were sampled, with 10 replications of the procedure for each treatment at each location. Although washers were set on a warmwater setting, the wash water temperatures ranged from 24 to 51 degrees C. The quaternary ammonium product seemed most effective, averaging a 97% microbial kill; chlorine was the second most effective, with a 58% kill, and the phenolic disinfectant was least effective, with only a 25% kill. The efficacies of the chlorine and phenolic disinfectants were reduced at low water temperatures commonly experienced in self-service laundries. Interfamily cross-contamination in self-service facilities is a potential public health problem, which is aggravated by environmental conditions, such as water temperature and the practices of the previous users of the equipment. Procedural changes in laundering are recommended, including the use of a disinfectant to maintain adequate levels of sanitation.  相似文献   

2.
Aims: To identify and quantify the presence of Escherichia coli, Staphylococcus aureus, Salmonella, hepatitis A and norovirus in households and to assess the effect of chlorine and quaternary ammonium–based disinfectants following a prescribed use. Methods and Results: Eleven sites distributed in kitchen, bathroom, pet and children′s areas of two groups of 30 homes each: (i) a nonprescribed disinfectant user group and (ii) a disinfectant protocol user group. During the 6‐week study, samples were collected once a week except for week one when sample collection occurred immediately before and after disinfectant application to evaluate the disinfectant protocol. The concentration and occurrence of bacteria were less in the households with prescribed use of disinfectants. The greatest reductions were for E. coli (99%) and Staph. aureus (99·9999%), respectively. Only two samples were positive for HAV, while norovirus was absent. Disinfection protocols resulted in a significant (P < 0·05) microbial reduction in all areas of the homes tested compared to homes not using a prescribed protocol. Conclusions: The study suggests that disinfectant product application under specific protocol is necessary to achieve greater microbial reductions. Significance and Impact of the Study: Prescribed protocols constitute an important tool to reduce the occurrence of potential disease‐causing micro‐organisms in households.  相似文献   

3.
冯宇  王芳  丁家波  蒋卉 《微生物学通报》2021,48(3):1033-1040
[背景]布鲁氏菌是一种重要的人畜共患胞内寄生菌,是引起动物和人发生布鲁氏菌病(布病)的病原体.高效消毒剂杀灭环境中的布鲁氏菌是防控布病的关键措施.[目的]评价市面上常用消毒剂对布鲁氏菌的灭菌效果及差异.[方法]选用市面上9种不同类型的常用消毒剂,以高、中、低3种不同使用浓度分别研究其对牛种、羊种和猪种布鲁氏菌的杀灭效果...  相似文献   

4.
A strain of Pseudomonas aeruginosa was isolated in pure culture from the reservoir of a hospital mist therapy unit by an extinction-dilution technique; its natural distilled water environment was used as a growth and maintenance medium. After a single subculture on Trypticase soy agar, the strain showed a marked decrease in resistance to inactivation by acetic acid, glutaraldehyde, chlorine dioxide, and a quaternary ammonium compound when compared with naturally occurring cells grown in mist therapy unit water. The following factors were observed to affect the relative resistances of naturally occurring and subcultured cells of the P. aeruginosa strain: (i) temperature at which the cultures were incubated prior to exposure to disinfectants, (ii) growth phase of the cultures at the time of exposure to disinfectants, (iii) nature of the suspending menstruum for disinfectants, and (iv) exposure to fluorescent light during incubation of inocula prior to testing. The applied significance of these findings may alter the present concepts of disinfectant testing as well as routine control procedures in the hospital environment.  相似文献   

5.
SUMMARY: On exposing a strain of Bacterium coli 28.D.10 in a surface film at atmospheric temperature to atmospheres of different moisture contents, it was found that for relative humidities between 100 and 66% the numbers of survivors decreased with decreasing humidity. There was also some evidence of a slight increase in survivors for a decrease in relative humidity from 43 to 0%.
The percentage of survivors of Bact. coli after exposure to quaternary ammonium disinfectants also decreased with relative humidity between 100 and 66% but no significant differences were found for changes in relative humidity below 66%. The numbers of survivors of a culture of Staphylococcus aureus were the same after storage at a relative humidity of 43% as at 100%; drying did not appear to affect the sensitivity of Staph. aureus to quaternary ammonium compounds. Tests of the effect of storage time in a saturated atmosphere gave results which were not entirely consistent, but where differences were observed, there was a lower percentage of survivors for freshly inoculated films than for films which had been stored for 3 hr, presumably because a fresh film was more easily removed to the disinfectant.
When either Bact. coli or Staph. aureus was exposed to a disinfectant, the percentage of survivors was higher when the organisms were in a surface film than when they were inoculated directly into the disinfectant. Agitation during exposure reduced the numbers of survivors from a surface film. Neither the glass nor the metal coming in contact with the disinfectants affected the level of survivors.
Under the conditions of testing, sodium hypochlorite was a more effective disinfectant than the quaternary ammonium compounds used.  相似文献   

6.
Aims: To determine the effectiveness of premilking teat‐cleaning regimes in reducing the teat microbial load and effect on milk quality. Methods and Results: The effectiveness of several premilking teat‐cleaning regimes in reducing teat microbial load was assessed using 40 cows on each of the four commercial UK dairy farms with herringbone parlours during two sampling periods. In the first experiment, all the treatments reduced teat total viable count (TVC), but there was no significant difference between the hypochlorite wash and dry wipe, iodine dip and dry and alcohol‐medicated wipe or dry wipe alone. In the second experiment, the chlorine wash and dry wipe was significantly more effective in reducing teat TVC than a water wash and dry, chlorine dip and dry or a dry wipe. There was no relationship between cleaning regime and milk TVC, Enterobacteriaceae or Escherichia coli levels. Conclusions: All of the cleaning techniques studied reduced teat microbial load, however, the chlorine wash and dry was the most effective. Significance and Impact of the study: The premilking teat‐cleaning techniques studied reduced the teat microbial load and therefore reduced the potential for milk contamination; however, a wash including an effective disinfectant followed by a dry wipe was the most effective.  相似文献   

7.
The antifungal effects of eight commercial disinfectants namely alcohol, peracetic acid, iodophors, aldehydes, quaternary amine compounds (QAC, a, b and c), and a chlorine-based agent were assessed at different concentrations. The time taken for these disinfectants to kill different microorganisms was used to assess their efficacy. The microorganisms tested were six yeasts,Saccharomyces cerevisiae, Saccharomyces uvarum, Kloeckera apiculata, Candida oleophila, Metschnikowia fructicola, Schizosaccharomyces pombe, and two moulds,Aspergillus niger (5 strains) andPenicillium roqueforti (5 strains). The disinfectants QAC (a) and QAC (c) were the most effective against all the microorganisms tested. The chlorine-based disinfectant worked most efficiently against the moulds at all concentrations used (0.5, 1.0, 1.5 and 2.0%). Peracetic acid and alcohol based disinfectants were most effective against the yeasts than mould. Tested yeasts were more resistant to the aldehyde and iodophors base disinfectants than the others.  相似文献   

8.
微生物消毒剂抗性机理   总被引:1,自引:0,他引:1  
在物体表面和传播介质中,消毒剂能有效抑制或杀死微生物,广泛用于食品、卫生、健康、防疫等领域.在新型冠状病毒肺炎(COVID-19)疫情期间,全球消毒剂的使用量激增,对有效防控病毒传播和防止疫情扩散起到重要作用.但消毒剂的不正确使用会降低其有效性,甚至会诱导微生物产生抗性,从而增加传染性疾病的传播风险.微生物的消毒剂抗性...  相似文献   

9.
在物体表面和传播介质中,消毒剂能有效抑制或杀死微生物,广泛用于食品、卫生、健康、防疫等领域。在新型冠状病毒肺炎(COVID-19)疫情期间,全球消毒剂的使用量激增,对有效防控病毒传播和防止疫情扩散起到重要作用。但消毒剂的不正确使用会降低其有效性,甚至会诱导微生物产生抗性,从而增加传染性疾病的传播风险。微生物的消毒剂抗性基因还会通过繁殖传代增殖或在不同种属间水平转移而加剧其污染和传播风险,严重威胁到公共卫生安全。目前,抗生素抗性基因(ARG)的广泛出现引起了全球对公共卫生的关注,但对消毒剂的抗性认识非常有限。本文综述了近年来微生物对消毒剂抗性的研究,着重就微生物通过形成生物膜、降低细胞膜通透性、过量表达外排泵、产生消除或减弱消毒剂的特异性酶、改变作用靶点等方式产生抗性的机理进行综述。另外针对微生物消毒剂抗性的获得和传播,对染色体和质粒介导的抗性基因、环境中微生物消毒剂抗性与抗生素抗性的关联进行了论述。消毒剂抗性基因能通过质粒、噬菌体等可移动遗传元件,以转化、转导或接合的方式转移传播,对科学消毒提出新要求。  相似文献   

10.
Chytridiomycosis, a disease contributing to amphibian declines worldwide, is caused by the fungus Batrachochytrium dendrobatidis. Identifying efficient and practical disinfectants effective against B. dendrobatidis is important to reduce the spread of the disease both in the wild and captivity. Previous studies identified a range of suitable disinfectant strategies. We evaluated the suitability of 3 additional disinfectants: two of these (TriGene Virucidal Disinfectant Cleaner and F10 Super Concentrate Disinfectant) are mixtures of chemicals and one (Betadine Antiseptic Liquid) contains a single active ingredient, povidone iodine. The disinfectants were tested using a range of concentrations for 1,5 and 10 min to determine their ability to kill B. dendrobatidis in vitro. The measure of effectiveness was 100% kill of zoosporangia grown in multiwell plates. All disinfectants had a 100% efficacy at concentrations recommended by the manufacturers. The lowest concentrations capable of 100% kill after exposure for 1 min were 0.1 ml l(-1) for TriGene, 0.33 ml l(-1) for F10 and 100 ml l(-1) for Betadine. TriGene is the most effective disinfectant yet to be found, and both TriGene and F10 are more effective than various disinfectants tested in previous studies. TriGene and F10 are considered suitable for use in the field, as only small amounts of concentrate are needed.  相似文献   

11.
Inactivation of biofilm bacteria   总被引:18,自引:0,他引:18  
The current project was developed to examine inactivation of biofilm bacteria and to characterize the interaction of biocides with pipe surfaces. Unattached bacteria were quite susceptible to the variety of disinfectants tested. Viable bacterial counts were reduced 99% by exposure to 0.08 mg of hypochlorous acid (pH 7.0) per liter (1 to 2 degrees C) for 1 min. For monochloramine, 94 mg/liter was required to kill 99% of the bacteria within 1 min. These results were consistent with those found by other investigators. Biofilm bacteria grown on the surfaces of granular activated carbon particles, metal coupons, or glass microscope slides were 150 to more than 3,000 times more resistant to hypochlorous acid (free chlorine, pH 7.0) than were unattached cells. In contrast, resistance of biofilm bacteria to monochloramine disinfection ranged from 2- to 100-fold more than that of unattached cells. The results suggested that, relative to inactivation of unattached bacteria, monochloramine was better able to penetrate and kill biofilm bacteria than free chlorine. For free chlorine, the data indicated that transport of the disinfectant into the biofilm was a major rate-limiting factor. Because of this phenomenon, increasing the level of free chlorine did not increase disinfection efficiency. Experiments where equal weights of disinfectants were used suggested that the greater penetrating power of monochloramine compensated for its limited disinfection activity. These studies showed that monochloramine was as effective as free chlorine for inactivation of biofilm bacteria. The research provides important insights into strategies for control of biofilm bacteria.  相似文献   

12.
Inactivation of biofilm bacteria.   总被引:6,自引:14,他引:6       下载免费PDF全文
The current project was developed to examine inactivation of biofilm bacteria and to characterize the interaction of biocides with pipe surfaces. Unattached bacteria were quite susceptible to the variety of disinfectants tested. Viable bacterial counts were reduced 99% by exposure to 0.08 mg of hypochlorous acid (pH 7.0) per liter (1 to 2 degrees C) for 1 min. For monochloramine, 94 mg/liter was required to kill 99% of the bacteria within 1 min. These results were consistent with those found by other investigators. Biofilm bacteria grown on the surfaces of granular activated carbon particles, metal coupons, or glass microscope slides were 150 to more than 3,000 times more resistant to hypochlorous acid (free chlorine, pH 7.0) than were unattached cells. In contrast, resistance of biofilm bacteria to monochloramine disinfection ranged from 2- to 100-fold more than that of unattached cells. The results suggested that, relative to inactivation of unattached bacteria, monochloramine was better able to penetrate and kill biofilm bacteria than free chlorine. For free chlorine, the data indicated that transport of the disinfectant into the biofilm was a major rate-limiting factor. Because of this phenomenon, increasing the level of free chlorine did not increase disinfection efficiency. Experiments where equal weights of disinfectants were used suggested that the greater penetrating power of monochloramine compensated for its limited disinfection activity. These studies showed that monochloramine was as effective as free chlorine for inactivation of biofilm bacteria. The research provides important insights into strategies for control of biofilm bacteria.  相似文献   

13.
消毒剂是一种可杀灭物体表面、器材设备、皮肤、空气和水源等传播媒介上携带的病原微生物的有机分子。它在体外能杀灭病原微生物,切断其传播途径,进而达到控制污染的目的,在生命安全防控中起着重要的作用。但是不合理地使用消毒剂导致细菌对消毒剂产生耐药。消毒剂耐药基因在不同种属间的水平转移加剧其传播风险,使消毒剂耐药情况进一步恶化。更令人担忧的是,细菌对消毒剂的耐药可能会导致对抗生素产生共耐药,给公共安全带来巨大的威胁。但目前为止,对消毒剂耐药以及共耐药的认识还不够全面。本文总结了关于细菌对消毒剂耐药的研究报道,对消毒剂的作用机制、细菌对消毒剂的耐药机制进行了论述,另外针对消毒剂耐药基因的传播以及细菌对消毒剂和抗生素的共耐药进行了综述,为减少消毒剂耐药性的产生和制定合理的消毒剂使用规范奠定基础。  相似文献   

14.
A number of proprietary disinfectant products (18) used in the food industry were tested for their bactericidal efficacy against Pseudomonas aeruginosa and Escherichia coli O157:H7 at 20 and 10 degrees C according to the BS EN 1276 (1997) quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and antiseptics used in food, industrial, domestic and institutional areas. At 20 degrees C, 13 products passed at their in-use concentration (under clean and dirty conditions) against Ps. aeruginosa and 15 passed against E. coli O157:H7. The number of products passing the test at 10 degrees C was 11 and 14 for Ps. aeruginosa and E. coli O157:H7, respectively. The products exhibiting reduced efficacy at the lower temperature were amphoterics and quaternary ammonium compounds although some of these types of products were effective at both temperatures. Products that passed against Ps. aeruginosa generally also passed against E. coli O157:H7. Taking all the results together, only 11 of the total of 18 products achieved a pass result under all the parameters tested. This work demonstrates the need for final verification of disinfectant efficacy by undertaking field trials in the food-processing environment in which the product is intended for use.  相似文献   

15.
Wang  Yang  Zhang  Xiaojian  Feng  Shuo  Niu  Zhangbin  Chen  Chao 《Annals of microbiology》2009,59(2):353-358
To study the inactivation characteristic of iron bacteria isolated from real drinking water distribution systems and investigate the influence of disinfectants, pH and temperature on inactivation process. Two kinds of iron bacteria were isolated from the water phase in distribution systems and identified asAcinetobacter baumannii andMicrobacterium oxydans. Bench-scale study on inactivation of the two kinds of iron bacteria were carried out, with the impact of disinfectants, pH and temperature under different levels concerned. Free chlorine and monochloramine could achieve an inactivation rate of 99.9% on bothA. Baumannii andM. Oxydans with the CT-value of 10 mg/L·min. Free chlorine was more effective than monochloramine with 1∼2 log higher inactivation rate.Microbacterium oxydans was more resistant to disinfectant thanA. Baumannii. High pH enhanced the inactivation of A.baumannii and low temperature availed the inactivation of bothA. Baumannii andMicrobacterium. For iron bacteria in the water, inactivation ratio could not reach 99% when residual chlorine was 0.05 mg/L in drinking water distribution systems according to Standards for Drinking Water Quality.  相似文献   

16.
抗消毒剂型微生物培养基研究   总被引:2,自引:1,他引:1  
二氧化氯、过氧乙酸、次氯酸钠及过氧化氢等消毒剂高浓度可以杀灭微生物,低浓度可以抑制微生物生长。在微生物检测中,要消除消毒剂的干扰,培养基的抗消毒剂指数必须控制在12.0—24.5之间。消毒剂解抑剂Ⅰ的抗消毒剂指数为 12.0,对细菌和真菌生长无明显抑制作用,加入经改良和优化的普通培养基后,制得5种抗消毒剂型培养基,在灭菌前后和一年的保存期内,其抗消毒剂指数基本保持不变。当采用大样倾注平板法和液体大样法检测残留消毒剂的样品时,使用抗消毒剂型培养基检出细菌和真菌能力大大高于普通培养基。  相似文献   

17.
Aims: The purpose of this study was to identify an effective disinfectant for the inactivation of the bacteriophages (phages) being used in our laboratory, as published studies on phage inactivation are far from unanimous in their conclusions. Methods and Results: The phages studied were three closely related strains of Myoviridae and three strains of Siphoviridae. Three disinfectants which are used commonly in microbiology laboratories were evaluated: Virkon (1%), ethanol (75%) and sodium hypochlorite (2500 ppm available chlorine). The most effective of these was Virkon, which inactivated all six phages rapidly. Ethanol was effective against the Myoviridae but had little effect on the Siphoviridae. Sodium hypochlorite was the least effective of the disinfectants evaluated. Conclusions: The findings of this study demonstrate a wide diversity in the effectiveness of disinfectants tested for inactivation of phages. Significance and Impact of the Study: Of the disinfectants tested Virkon is the most suitable choice for those unable to carry out disinfection validation studies, or where a broad spectrum disinfectant against phages is required. All of the phages in this study showed resilience to inactivation by sodium hypochlorite, and therefore this disinfectant is an unwise choice for use against phage without first assessing its effectiveness.  相似文献   

18.
Bovine mastitis caused by the yeast-like alga Prototheca zopfii represents a serious veterinary problem and may result in heavy economic losses to particular dairy farms. The purpose of this study was to evaluate the survival of 50 isolates of P. zopfii in milk subjected to different heat treatments and the survival of further 106 P. zopfii isolates after exposure to three classes of teat disinfectants: iodine (Dipal), quaternary ammonium compounds (Teat), and dodecylbenzenesulphonic acid (Blu-gard). Of the 50 isolates tested for thermal tolerance, 29 (58%) survived heat treatment at 62°C for 30 s and 13 (26% of all isolates) of those survived after heat treatment at 72°C for 15 s. None of the 106 isolates were able to withstand the in-use concentrations of the three disinfectants tested. The highest disinfectant concentrations that permitted survival of at least one isolate were dilutions: 1:1,000 for Dipal (survival rate of 52.8–57.5%), 1:100 for Teat (88.7–90.6%), and 1:10 for Blu-gard (100%). No differences in the survival rates of P. zopfii were observed with respect to the duration of exposure to disinfectant. The results of this study support the previous findings that P. zopfii may resist high-temperature treatments, including that applied in the high-temperature, short-time (HTST) pasteurization process. The obtained data also demonstrate the efficacy of the three classes of teat disinfectants against P. zopfii, with the efficacy of iodine being most pronounced. The study emphasizes the necessity of using higher temperatures in the pasteurization of raw milk to kill the Prototheca algae, as well as the particular suitability of the iodine for the control procedures of protothecal mastitis.  相似文献   

19.
Six common water bacteria were examined for their ability to colonize polyvinyl chloride (PVC) surfaces, survive various germicidal treatment, and re-establish themselves in sterile distilled water (SDW). For each test, two 30·4 cm PVC pipes attached to a 90° PVC elbow were filled with 600 ml of distilled water inoculated with either Pseudomonas aeruginosa, Ps. cepacia, Ps. mesophilica, Acinetobacter anitratus, Mycobacterium chelonae or M. chelonae var. abscessus. After 8 weeks contaminated water was removed and the pipes were exposed to 600 ml of 1 : 213 iodophor disinfectant (ID), 1 : 128 phenolic detergent (P), 1 : 256 quaternary ammonium compound (QA), stock iodophor antiseptic (IA), 2% formaldehyde (F), 10–15 ppm free chlorine (C), 2% glutaraldehyde (G) and 70% ethanol (E). These germicides were periodically sampled, neutralized and examined for surviving organisms. After exposure for 7 d the germicides were removed and each pipe was refilled with SDW. This was assayed at 7 d intervals to determine microbial re-establishment. Samples were removed during microbial conditioning and examined by scanning electron microscopy (SEM). Pseudomonads were isolated directly from ID, QA, C, P and F, and mycobacteria from QA, IA, ID, P, G, C and F. Pseudomonas aeruginosa and Ps. cepacia survived in PVC pipes after 7 d of exposure to P, ID and C; Ps. mesophilica, after C and ID; and both mycobacteria, after C. SEM examination of PVC remnants revealed bacterial attachment and formation of extracellular material with embedded cells. These studies show that common water bacteria can attach and colonize the interior surface of PVC pipes and develop significant resistance to the action of certain germicides. Specific disinfection strategies are needed to control microbial populations that form in water distribution systems.  相似文献   

20.
There is a general consensus that with increasing age a biofilm shows increased resistance to antimicrobials. In this study the susceptibility of 3-, 5- and 7-day-old Salmonella enterica serovar Typhimurium biofilms to disinfectants was evaluated. It was hypothesized that 7-day-old biofilms would be more resistant to disinfectants compared to 3- and 5-day-old biofilms. Biofilms were formed using the MBEC? system and treated with six chemical disinfectants for 1 and 5 min. Four disinfectants at the highest concentration available showed 100% reduction in viable cells from all ages of biofilms after exposure for 5 min, and ethanol at 70% v/v was the least effective against biofilms, followed by chlorhexidine gluconate (CG). At the recommended user concentrations, only sodium hypochlorite showed 100% reduction in viable cells from all ages of biofilms. Benzalkonium chloride and CG were the least effective against biofilms, followed by quaternary ammonium compound which only showed 100% reduction in viable cells from 5-day-old biofilms. Overall, the results from this study do not display enhanced resistance in 7-day-old biofilms compared to 3- and 5-day-old biofilms. It is concluded that under the conditions of this study, the age of biofilm did not contribute to resistance towards disinfectants. Rather, the concentration of disinfectant and an increased contact time were both shown to play a role in successful sanitization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号