首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The ability to assess the elastic and failure properties of cortical bone at the radial diaphysis has a clinical importance. A new generation of quantitative ultrasound (QUS) devices and peripheral quantitative computed tomography (p-QCT) has been developed to assess non-invasively bone material and structural properties at the distal radius. This anatomical site is characterized by a thin cortical thickness that complicates traditional mechanical testing methods on specimens. Until now, mechanical properties of cortical bone at distal radius (e.g., elastic modulus, yield stress and strain) remain rarely studied probably due to experimental difficulties. The present study introduces an inverse finite-element method strategy to measure the elastic modulus and yield properties of human cortical specimens of the radial diaphysis. Twenty millimeter-thick portions of diaphysis were cut from 40 human radii (ages 45-90) for biomechanical test. Subsequently the same portion was modeled in order to obtain a specimen-specific three dimensional finite-element model (3D-FEM). Longitudinal elastic constants at the apparent level and stress characterizations were performed by coupling mechanical parameters with isotropic linear-elastic simulations. The results indicated that the mean apparent Young's modulus for radial cortical bone was 16 GPa (SD 1.8) and the yield stress was 153 MPa (SD 33). Breaking load was 12,946 N (SD 3644), cortical thickness 2.9 mm (SD 0.6), structural effective strain at the yield (epsilon(y)=0.0097) and failure (epsilon(u)=0.0154) load were also calculated. The 3D-FEM strategy described here may help to investigate bone mechanical properties when some difficulties arise from machining mechanical sample.  相似文献   

2.
The skeletal response to short-term exercise training remains poorly described. We thus studied the lower limb skeletal response of 723 Caucasian male army recruits to a 12-wk training regime. Femoral bone volume was assessed using magnetic resonance imaging, bone ultrastructure by quantitative ultrasound (QUS), and bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA) of the hip. Left hip BMD increased with training (mean ± SD: 0.85 ± 3.24, 2.93 ± 4.85, and 1.89 ± 2.85% for femoral neck, Ward's area, and total hip, respectively; all P < 0.001). Left calcaneal broadband ultrasound attenuation rose 3.57 ± 0.5% (P < 0.001), and left and right femoral cortical volume by 1.09 ± 4.05 and 0.71 ± 4.05%, respectively (P = 0.0001 and 0.003), largely through the rise in periosteal volume (0.78 ± 3.14 and 0.59 ± 2.58% for right and left, respectively, P < 0.001) with endosteal volumes unchanged. Before training, DXA and QUS measures were independent of limb dominance. However, the dominant femur had higher periosteal (25,991.49 vs. 2,5572 mm(3), P < 0.001), endosteal (6,063.33 vs. 5,983.12 mm(3), P = 0.001), and cortical volumes (19,928 vs. 19,589.56 mm(3), P = 0.001). Changes in DXA, QUS, and magnetic resonance imaging measures were independent of limb dominance. We show, for the first time, that short-term exercise training in young men is associated not only with a rise in human femoral BMD, but also in femoral bone volume, the latter largely through a periosteal response.  相似文献   

3.
Association between oxidative stress and bone mineral density   总被引:15,自引:0,他引:15  
Free radicals have been shown to be involved in bone resorption in vitro and in rodents. We studied the effect of oxidative stress on bone mineral density (BMD) in 48 women and 53 men from a population-based study. The levels of 8-iso-PGF(2alpha) (a major F(2)-isoprostane and a biomarker of oxidative stress) and a control, 15-keto-dihydro-PGF(2alpha) (a biomarker of inflammatory response), were measured in urinary samples and their association with BMD and quantitative ultrasound (QUS) measurements were examined. In multivariate linear regression analyses, 8-iso-PGF(2alpha) levels were negatively associated with both BMD and QUS. In contrast, no association was found for 15-keto-dihydro-PGF(2alpha). Our findings establish a biochemical link between increased oxidative stress and reduced bone density and provide a rational for further studies investigating the role of pro- and antioxidants in osteoporosis.  相似文献   

4.
5.
A longitudinal study was conducted to investigate the relation between a polymorphism in the vitamin D receptor (VDR) gene and changes in bone mineral density (BMD) and quantitative ultrasound of the phalanges (QUS) over a five-year period. The subjects were 456 postmenopausal women with osteoporosis undergoing treatment, aged 59.95±7.97 years (mean±standard deviation [SD]) at baseline. BMD was measured at the hips and lumbar spine by dual-energy X-ray absorptiometry, and QUS was measured by means of amplitude-dependent speed of sound (Ad-SoS) at the phalanges. Lifestyle information was obtained via a questionnaire. The genotype frequencies of the BsmI (rs1544410) gene polymorphism were 29.4%, 47.1%, and 23.5% for bb, Bb, and BB, respectively. After five years, BMD (annual change in %/year) at the femoral neck (FN) showed a significant modification based on the rs1544410 genotype (BB vs Bb); there was an overall decrease in bone mass (-0.70±2.79%/year; P = 0.025). An analysis of covariance with adjustments for age, weight, height, percentage of weight change per year, baseline BMD and calcium intake showed that the observed associations were no longer significant (P = 0.429). No significant associations were found between the QUS measurements and the rs1544410 genotype after the five-year period. Our study limitations includes lack of information about type and length of duration of the osteoporosis treatment. Our results indicate that rs1544410 polymorphisms do not account significantly for the changes in bone mass in Spanish women with osteoporosis undergoing treatment.  相似文献   

6.
The microarchitecture and alignment of trabecular bone adapts to the particular mechanical milieu applied to it. Due to this anisotropic mechanical property, measurement orientation has to be taken into consideration when assessing trabecular bone quality and fracture risk prediction. Quantitative ultrasound (QUS) has demonstrated the ability in predicting the principal structural orientation (PSO) of trabecular bone. Although the QUS prediction for PSO is very close to that of \(\upmu \) CT, certain angle differences still exist. It remains unknown whether this angle difference can induce significant differences in mechanical properties or not. The objective of this study was to evaluate the mechanical properties in different PSOs predicted using different methods, QUS and \(\upmu \) CT, thus to investigate the ability of QUS as a means to predict the PSO of trabecular bone noninvasively. By validating the ability of QUS to predict the PSO of trabecular bone, it is beneficial for future QUS applications because QUS measurements in the PSO can provide information more correlated with the mechanical properties than with other orientations. In this study, seven trabecular bone balls from distal bovine femurs were used to generate finite element models based on the 3-dimensional \(\upmu \) CT images. Uniaxial compressive loading was performed on the bone ball models in the finite element analysis (FEA) in six different orientations (three anatomical orientations, two PSOs predicted by QUS and the longest vector of mean intercept length (MIL) tensor calculated by \(\upmu \) CT). The stiffness was calculated based on the reaction force of the bone balls under loading, and the von Mises stress results showed that both the mechanical properties in the PSOs predicted by QUS are significantly higher than the anatomical orientations and comparatively close to the longest vector of MIL tensor. The stiffness in the PSOs predicted by QUS is also highly correlated with the stiffness in the MIL tensor orientation (ATTmax vs. MIL, \(R^{2}\)  = 0.98, \(p<001\) ; UVmax vs. MIL, \(R^{2}\)  = 0.92, \(p<001\) ). These results were validated by in vitro mechanical testing on the bone ball samples. This study demonstrates that the PSO of trabecular bone predicted by QUS has an equally strong apparent stiffness with the orientation predicted by \(\upmu \) CT.  相似文献   

7.
As cortical bone has a hierarchical structure, the macroscopic bone strength may be affected by the alterations of mineral crystal and collagen, which are main components of cortical bone. Limited studies focused on the time related alterations of these two components in osteoporosis, and their contributions to bone mechanics at tissue level and whole-bone level. Therefore, the purpose of this study was to elucidate the time related changes of mineral and collagen in cortical bone of ovariectomized (OVX) rabbits, and to relate these changes to cortical bone nanomechanics and macromechanics. 40 Rabbits (7-month-old) were randomly allocated into two groups (OVX and sham). OVX group received bilateral ovariectomy operation. Sham group received sham-OVX operation. Cortical bone quality of five rabbits in each group were assessed by DXA, μCT, nanoindentation, Fourier transform infrared (FTIR) spectroscopy and biomechanical tests (3-point bending of femoral midshaft) at pre-OVX, 4, 6, and 8 weeks after OVX. As time increased from pre-OVX to 8 weeks, the mineral to matrix ratio decreased with time, while both collagen crosslink ratio and crystallinity increased with time in OVX group. Elastic modulus and hardness measured by nanoindentation, whole-bone strength measured by biomechanical tests all decreased in OVX group with time. Bone material properties measured by FTIR correlated well with nano or whole-bone level mechanics. However, bone mineral density (BMD), structure, tissue-level and whole-bone mechanical properties did not change with age in sham group. Our study demonstrated that OVX could affect the tissue-level mechanics and bone strength of cortical bone. And this influence was attributed to the time related alterations of mineral and collagen properties, which may help us to design earlier interventions and more effective treatment strategies on osteoporosis.  相似文献   

8.
Ob/ob and db/db mice have different aberrations in leptin signaling that both lead to abnormalities in bone mineral density (BMD), and bone histological and histomorphometric outcomes. A few studies have directly compared bone metabolism in ob/ob and db/db mice, and biomechanical strength properties that are surrogate measures of fracture risk, have not been extensively studied. This study compared bone mineral content (BMC), BMD and biomechanical strength properties of femurs and lumbar vertebrae among 10 week old male ob/ob, db/db and C57Bl/6 wildtype (WT) mice. Femurs and lumbar vertebrae were specifically studied to determine if trabecular and cortical bone are regulated by leptin in a similar manner in ob/ob and db/db mice. Femurs of ob/ob and db/db mice had lower BMC, BMD and biomechanical strength properties, including peak load, compared to WT mice. In contrast, lumbar vertebrae BMC and BMD did not differ among genotypes, nor did the peak load from compression testing of an individual lumbar vertebra differ among groups. These findings suggest that leptin deficiency in adolescent male mice first results in changes in femurs, a representative long bone, and alterations in lumbar vertebrae may occur later in life.  相似文献   

9.
ObjectivePredominance of bone loss in cortical sites with relative preservation of trabecular bone, even in postmenopausal women, has been described in primary hyperparathyroidism (PHPT). The aim of this study was to evaluate bone microarchitectural differences using dual-energy x-ray absorptiometry (DXA), trabecular bone score (TBS), and DXA-based 3-dimensional (3D) modeling (3D-DXA) between postmenopausal women diagnosed with PHPT (PM-PHPT) and healthy postmenopausal controls.MethodsThis retrospective study included 44 women with PM-PHPT (9 of whom had fractures) and 48 healthy women matched by age, body mass index, and years since menopause treated at Hospital Universitario Fundación Jiménez Díaz between 2008 and 2017. The bone mineral density (BMD) of the lumbar spine (LS), femoral neck, total hip (TH), and 1/3 radius was assessed using DXA, and trabecular volumetric BMD (vBMD), cortical vBMD, integral vBMD, cortical thickness, and cortical surface BMD at TH were assessed using a 3D-DXA software and TBS at LS.ResultsThe mean adjusted BMD values at LS, the femoral neck, and TH; TBS at LS; and TH 3D-DXA parameters (trabecular vBMD, integral vBMD, cortical thickness, and cortical surface BMD) were significantly reduced in women with PM-PHPT compared with those in the controls. However, differences in mean cortical vBMD were not statistically significant (P = .078). There were no significant differences in mean BMD, TBS, or the 3D-DXA parameters between patients with fractures and those without fractures. The 25-hydroxyvitamin D level appeared to be associated with TBS but not with DXA and 3D-DXA measurements.ConclusionPM-PHPT has significant involvement of the trabecular and cortical compartments of the bone, as determined by DXA, TBS, and 3D-DXA.  相似文献   

10.
In this study the relationships of bone mineral density (BMD) and bone structure parameters calculated from 2D microtomography images to bone strength were investigated. Femurs from 21 male Sprague Dawley rats were subjected to dual-energy X-ray absorptiometry, computerized microtomography (CmicroT) and either three-point cantilever bending (femoral shaft) or two-point bending compression (femoral neck). Gastrectomy was performed on 12 animals and 9 were sham operated. From the tomograms bone structure analysis was performed using a software routine based on grey level run-length method. Correlations of BMD and bone structure parameters to mechanical parameters were investigated as were differences between the gastrectomized and the control samples. The reductions of BMD between the groups were 21 and 27% in the femoral neck and shaft, respectively. For the shaft, the correlations of BMD to all mechanical parameters were significant and BMD was a consistent predictor of bone strength for cortical bone. However, in the femoral neck where cancellous bone predominates, BMD was weakly correlated only to deflection. A significant correlation between trabecular thickness and neck bone strength was found. Hence, compared to trabecular thickness, BMD was of limited value in predicting bone strength in the femoral neck.  相似文献   

11.
The physical principles underlying quantitative ultrasound (QUS) measurements in trabecular bone are not fully understood. The translation of QUS results into bone strength remains elusive. However, ultrasound being mechanical waves, it is likely to assess apparent bone elasticity. The aim of this study is to derive the sensitivity of QUS parameters to variations of apparent bone elasticity, a surrogate for strength. The geometry of 34 human trabecular bone samples cut in the great trochanter was reconstructed using 3-D synchrotron micro-computed tomography. Finite-difference time-domain simulations coupled to 3-D micro-structural models were performed in the three perpendicular directions for each sample and each direction. A voxel-based micro-finite element linear analysis was employed to compute the apparent Young's modulus (E) of each sample for each direction. For the antero-posterior direction, the predictive power of speed of sound and normalized broadband ultrasonic attenuation to assess E was equal to 0.9 and 0.87, respectively, which is better than what is obtained using bone density alone or coupled with micro-architectural parameters and of the same order of what can be achieved with the fabric tensor approach. When the direction of testing is parallel to the main trabecular orientation, the predictive power of QUS parameters decreases and the fabric tensor approach always gives the best results. This decrease can be explained by the presence of two longitudinal wave modes. Our results, which were obtained using two distinct simulation tools applied on the same set of samples, highlight the potential of QUS techniques to assess bone strength.  相似文献   

12.
13.

Purpose

Genome-wide association studies (GWAS) have identified 6q25, which incorporates the oestrogen receptor α gene (ESR1), as a quantitative trait locus for areal bone mineral density (BMDa) of the hip and lumbar spine. The aim of this study was to determine the influence of this locus on other bone health outcomes; calcaneal ultrasound (QUS) parameters, radial peripheral quantitative computed tomography (pQCT) parameters and markers of bone turnover in a population sample of European men.

Methods

Eight single nucleotide polymorphisms (SNP) in the 6q25 locus were genotyped in men aged 40–79 years from 7 European countries, participating in the European Male Ageing Study (EMAS). The associations between SNPs and measured bone parameters were tested under an additive genetic model adjusting for centre using linear regression.

Results

2468 men, mean (SD) aged 59.9 (11.1) years had QUS measurements performed and bone turnover marker levels measured. A subset of 628 men had DXA and pQCT measurements. Multiple independent SNPs showed significant associations with BMD using all three measurement techniques. Most notably, rs1999805 was associated with a 0.10 SD (95%CI 0.05, 0.16; p = 0.0001) lower estimated BMD at the calcaneus, a 0.14 SD (95%CI 0.05, 0.24; p = 0.004) lower total hip BMDa, a 0.12 SD (95%CI 0.02, 0.23; p = 0.026) lower lumbar spine BMDa and a 0.18 SD (95%CI 0.06, 0.29; p = 0.003) lower trabecular BMD at the distal radius for each copy of the minor allele. There was no association with serum levels of bone turnover markers and a single SNP which was associated with cortical density was also associated with cortical BMC and thickness.

Conclusions

Our data replicate previous associations found between SNPs in the 6q25 locus and BMDa at the hip and extend these data to include associations with calcaneal ultrasound parameters and radial volumetric BMD.  相似文献   

14.
We performed a comparative study of bone mechanical properties in the radii of chimpanzees (Pan troglodytes), humans (Homo sapiens), and Japanese macaques (Macaca fuscata) using peripheral quantitative computed tomography. We investigated: (1)cortical bone area relative to the total periosteal area (PrA); (2) trabecular bone area relative to PrA; (3) cortical bone density; and (4) trabecular bone density. The cortical bone area index for chimpanzees was almost the same as that of Japanese macaques, whereas the equivalent value in humans was about the two-fifths that of the others. Values for the other three properties were constant among these three catarrhine species. Chimpanzees do not particularly resemble humans, but are more similar to digitigrade macaques in terms of bone properties. The constant trabecular bone area index and trabecular density value in these species may suggest that a certain amount of trabecular bone (20–30% of total bone area at the distal 4% level of the forearm) is necessary to achieve normal bone turnover. The physiological metabolism of bone, including cortical bone density, might be conserved in these catarrhines. Electronic Publication  相似文献   

15.

Objective

Reduced bone mineral density (BMD), assessed by Dual Energy X-ray absorptiometry (DXA), is a well-known risk factor for fragility fracture. A large proportion of patients with fracture have only slightly reduced BMD. Assessment of other bone structure features than BMD may improve identification of individuals at increased fracture risk. Digital X-ray radiogrammetry (DXR), which is a feasible tool for measurement of metacarpal cortical bone density, also gives an estimate of cortical bone porosity. Our primary aim was to explore the association between cortical porosity in the hand assessed by DXR and distal radius fracture.

Methods

This case-control study included 123 women >50 years with distal radius fracture, and 170 controls. DXR was used to measure metacarpal BMD (DXR-BMD), cortical porosity (DXR-porosity), thickness (DXR-CT) and bone width (DXR-W) of the hand. Femoral neck BMD was measured by DXA.

Results

The fracture group had a statistically significant lower DXR-BMD (0.492 vs. 0.524 g/cm2 p<0.001), higher cortical DXR-porosity (0.01256 vs. 0.01093, p<0.001), less DXR-CT (0.148 vs. 0.161cm, p<0.001) and lower femoral neck DXA-BMD (0.789 vs. 0.844 g/cm2, p = 0.001) than the controls. In logistic regression analysis adjusted for age, a significant association with distal radius fracture (OR, 95% CI) was found for body mass index (0.930, 0.880–0.983), DXA-BMD (0.996, 0.995–0.999), DXR-BMD (0.990, 0.985–0.998), DXR-porosity (1.468, 1.278–1.687) and DXR-CT (0.997, 0.996–0.999). In an adjusted model, DXR-porosity remained the only variable associated with distal radius fracture (1.415, 1.194–1.677).

Conclusion

DXR derived porosity is associated with fracture at distal radius and might be a sensitive marker for skeletal fragility.  相似文献   

16.
Receptor activator of NF-kappaB ligand (RANKL), produced by osteoblastic lineage cells and activated T cells, is an essential factor for osteoclast differentiation, activation, and survival. Therefore, RANKL is a focal point of therapies targeting bone diseases where there is an imbalance of bone metabolism in favor of bone resorption. The present study assesses the effects of exogenous RANKL on growing bone. RANKL (100 microg x kg-1x day-1 for 7 days) administered to Sprague-Dawley weanling rats caused major deficits in growth, appearance, and bone mineral densities (BMD). Urinary deoxypyridinoline crosslinks, a measure of bone turnover, were higher in the RANKL-treated rats (P = 0.031), and the bone mineral content was lower (P < 0.001). The final BMD in the RANKL-treated rats was lower (P = 0.039) than in the control rats (19 +/- 7 vs. 38 +/- 5 mg/cm3). Moreover, calculated cortical bone density in each bone slice (total BMD - trabecular BMD) indicated there was only 5% cortical bone remaining in RANKL-treated rats. We conclude that therapies targeting RANKL are likely to have effects on cortical as well as trabecular bone density.  相似文献   

17.
Insulin-like growth factor-1 (IGF-1) plays a critical role in the development of the growing skeleton by establishing both longitudinal and transverse bone accrual. IGF-1 has also been implicated in the maintenance of bone mass during late adulthood and aging, as decreases in serum IGF-1 levels appear to correlate with decreases in bone mineral density (BMD). Although informative, mouse models to date have been unable to separate the temporal effects of IGF-1 depletion on skeletal development. To address this problem, we performed a skeletal characterization of the inducible LID mouse (iLID), in which serum IGF-1 levels are depleted at selected ages. We found that depletion of serum IGF-1 in male iLID mice prior to adulthood (4 weeks) decreased trabecular bone architecture and significantly reduced transverse cortical bone properties (Ct.Ar, Ct.Th) by 16 weeks (adulthood). Likewise, depletion of serum IGF-1 in iLID males at 8 weeks of age, resulted in significantly reduced transverse cortical bone properties (Ct.Ar, Ct.Th) by 32 weeks (late adulthood), but had no effect on trabecular bone architecture. In contrast, depletion of serum IGF-1 after peak bone acquisition (at 16 weeks) resulted in enhancement of trabecular bone architecture, but no significant changes in cortical bone properties by 32 weeks as compared to controls. These results indicate that while serum IGF-1 is essential for bone accrual during the postnatal growth phase, depletion of IGF-1 after peak bone acquisition (16 weeks) is compartment-specific and does not have a detrimental effect on cortical bone mass in the older adult mouse.  相似文献   

18.
Current diagnosis of bone loss and osteoporosis is based on the measurement of the bone mineral density (BMD) or the apparent mass density. Unfortunately, in most clinical ultrasound densitometers: 1) measurements are often performed in a single anatomical direction, 2) only the first wave arriving to the ultrasound probe is characterized, and 3) the analysis of bone status is based on empirical relationships between measurable quantities such as speed of sound (SOS) and broadband ultrasound attenuation (BUA) and the density of the porous medium. However, the existence of a second wave in cancellous bone has been reported, which is an unequivocal signature of poroelastic media, as predicted by Biot’s poroelastic wave propagation theory. In this paper, the governing equations for wave motion in the linear theory of anisotropic poroelastic materials are developed and extended to include the dependence of the constitutive relations upon fabric—a quantitative stereological measure of the degree of structural anisotropy in the pore architecture of a porous medium. This fabric-dependent anisotropic poroelastic approach is a theoretical framework to describe the microarchitectural-dependent relationship between measurable wave properties and the elastic constants of trabecular bone, and thus represents an alternative for bone quality assessment beyond BMD alone.  相似文献   

19.
Genome Wide Association Studies suggest that Wnt16 is an important contributor to the mechanisms controlling bone mineral density, cortical thickness, bone strength and ultimately fracture risk. Wnt16 acts on osteoblasts and osteoclasts and, in cortical bone, is predominantly derived from osteoblasts. This led us to hypothesize that low bone mass would be associated with low levels of Wnt16 expression and that Wnt16 expression would be increased by anabolic factors, including mechanical loading. We therefore investigated Wnt16 expression in the context of ageing, mechanical loading and unloading, estrogen deficiency and replacement, and estrogen receptor α (ERα) depletion. Quantitative real time PCR showed that Wnt16 mRNA expression was lower in cortical bone and marrow of aged compared to young female mice. Neither increased nor decreased (by disuse) mechanical loading altered Wnt16 expression in young female mice, although Wnt16 expression was decreased following ovariectomy. Both 17β-estradiol and the Selective Estrogen Receptor Modulator Tamoxifen increased Wnt16 expression relative to ovariectomy. Wnt16 and ERβ expression were increased in female ERα-/- mice when compared to Wild Type. We also addressed potential effects of gender on Wnt16 expression and while the expression was lower in the cortical bone of aged males as in females, it was higher in male bone marrow of aged mice compared to young. In the kidney, which we used as a non-bone reference tissue, Wnt16 expression was unaffected by age in either males or females. In summary, age, and its associated bone loss, is associated with low levels of Wnt16 expression whereas bone loss associated with disuse has no effect on Wnt16 expression. In the artificially loaded mouse tibia we observed no loading-related up-regulation of Wnt16 expression but provide evidence that its expression is influenced by estrogen receptor signaling. These findings suggest that while Wnt16 is not an obligatory contributor to regulation of bone mass per se, it potentially plays a role in influencing pathways associated with regulation of bone mass during ageing and estrogen withdrawal.  相似文献   

20.

Background

Calcaneal quantitative ultrasound (QUS), which is used in the evaluation of osteoporosis, is believed to be intimately associated with the characteristics of the proximal femur. However, the specific associations of calcaneal QUS with characteristics of the hip sub-regions remain unclear.

Design

A cross-sectional assessment of 53 osteoporotic patients was performed for the skeletal status of the heel and hip.

Methods

We prospectively enrolled 53 female osteoporotic patients with femoral fractures. Calcaneal QUS, dual energy X-ray absorptiometry (DXA), and hip structural analysis (HSA) were performed for each patient. Femoral heads were obtained during the surgery, and principal compressive trabeculae (PCT) were extracted by a three-dimensional printing technique-assisted method. Pearson’s correlation between QUS measurement with DXA, HSA-derived parameters and Young’s modulus were calculated in order to evaluate the specific association of QUS with the parameters for the hip sub-regions, including the femoral neck, trochanteric and Ward’s areas, and the femoral shaft, respectively.

Results

Significant correlations were found between estimated BMD (Est.BMD) and BMD of different sub-regions of proximal femur. However, the correlation coefficient of trochanteric area (r = 0.356, p = 0.009) was higher than that of the neck area (r = 0.297, p = 0.031) and total proximal femur (r = 0.291, p = 0.034). Furthermore, the quantitative ultrasound index (QUI) was significantly correlated with the HSA-derived parameters of the trochanteric area (r value: 0.315–0.356, all p<0.05) as well as with the Young’s modulus of PCT from the femoral head (r = 0.589, p<0.001).

Conclusion

The calcaneal bone had an intimate association with the trochanteric cancellous bone. To a certain extent, the parameters of the calcaneal QUS can reflect the characteristics of the trochanteric area of the proximal hip, although not specifically reflective of those of the femoral neck or shaft.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号