首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A highly sensitive enzyme-linked immunosorbent assay (ELISA) for quantitation of Clostridium perfringens enterotoxin (CPE) by a sandwich method with polystyrene beads was elaborated. The ELISA was very sensitive with a detection limit of 1 pg/ml of CPE. Clostridium perfringens culture fluid did not interfere with the assay. This ELISA may be useful for the mass screening for Cl. perfringens producing small amounts of CPE.  相似文献   

2.
章先  何珂  黄志伟  单颖  曹统  谢珲  宋厚辉 《菌物学报》2020,39(3):599-609
赭曲霉毒素(ochratoxins)主要是由青霉菌Penicillium和曲霉菌Aspergillus产生的有毒次级代谢产物,常见于发霉或发酵的农产品中,其中赭曲霉毒素A(ochratoxin A,OTA)毒性最强且最为普遍。OTA是粮食作物和饲料的重要污染物,在加工、储存或运输过程中均可产生,具有肾毒性和免疫毒性,可通过蓄积作用发挥毒性效应,对人类和动物健康造成严重威胁。本研究通过将OTA单克隆抗体包被于纳米磁珠(magnetic nanoparticles,MNPs)表面,获得具有免疫活性的磁珠抗体复合物(MNPs-Anti OTA),并制备生物素标记的偶联抗原OTA-BSA-Bio,后续采用链酶亲和素标记的纳米金颗粒(Strep-HRP-AuNPs)催化底物进行信号检测,最终建立了OTA高灵敏检测方法(MNPs-bs-AuNPs-ELISA)。在最优条件下,经计算该方法检测下限(IC10)为0.01ng/mL,检测区间(IC20-IC80)为0.02-0.73ng/mL,半数抑制率(IC50)为0.13ng/mL。与OTA类似物OTB、OTC交叉反应性为4.3%和8.1%,对其他常见真菌毒素AFB1、ZEN、FB1、DON、CIT和PAT均无交叉反应。玉米、面粉和大豆样本中的加标回收率可达85.6%-115.7%,对天然样本中OTA含量的检测结果表明,该方法与LC-MS/MS相关性良好。本研究建立的MNPs-bs-AuNPs-ELISA可满足谷物及饲料样本中OTA的快速、高灵敏度定量检测,成本较低,具有很好的应用前景。  相似文献   

3.
A two-site enzyme-linked immunosorbent assay for inhibin.   总被引:1,自引:0,他引:1  
The investigation of the role of inhibin in the regulation of fertility is hindered by the lack of a routine, specific assay. The pituitary cell bioassay is time-consuming and the existing RIAs, based on either purified bovine 32-kDa inhibin or synthetic alpha-subunit peptides, are not specific for the biologically active inhibin molecules. We have used monoclonal antibodies, one specific for the N-terminal region of the human inhibin alpha chain, and the other raised to a peptide sequence close to the C-terminal of the human beta A-inhibin chain, to create a two-site sandwich ELISA specific for alpha beta-inhibin molecules. This was used to estimate levels of inhibin in crude bovine and human follicular fluids and fractions concentrated from them. Comparison of the values obtained with the ELISA and those obtained with the pituitary cell bioassay, suggests that the ELISA measures biologically active inhibin. Compared with the peptide-based RIA, the ELISA gave much lower (as little as 100-fold lower) values for the inhibin content of these samples, e.g., bovine follicular fluid 0.375 micrograms/ml (ELISA) compared with 41.0 micrograms/ml (RIA). Such large differences, possibly due to the presence of relatively large amounts of biologically inactive forms of inhibin such as the pro-alpha c or free alpha forms, suggest that those RIAs, which essentially measure the level of alpha-inhibin, considerably overestimate the levels of the active forms of inhibin in the samples and that results obtained using these assays may need reinterpretation.  相似文献   

4.
A recording fluorometric assay for dihydrofolate reductase is described. The technique measures the appearance of product, tetrahydrofolate, as the reaction proceeds. The assay can be accomplished with as little as 2 pmol of enzyme and is sufficiently sensitive to allow accurate kinetic studies using very low concentrations of substrate. Kinetic studies of both purified and crude preparations of enzyme are reported.  相似文献   

5.
A rapid radiometric assay for dihydrofolate reductase   总被引:4,自引:0,他引:4  
A rapid radiochemical procedure for the measurement of dihydrofolate reductase activity is described. The method employs separation of the radiolabeled substrate from the products of the reaction by precipitation with acetic acid and zinc sulfate. This method permits rapid processing of samples and climinates time-consumlng column chromatography techniques. Good agreement of results is obtained when the radioactive method is compared to the spectrophotometric assay method.  相似文献   

6.
G J Marcus  R Durnford 《Steroids》1985,46(6):975-986
A new, enzyme-linked, immunosorbent assay for testosterone is described. The assay uses horseradish peroxidase coupled to testosterone as the tracer and offers the same sensitivity and reliability but greater convenience than radioimmunoassay. The assay is also simpler and more rapidly completed than previously described assays for testosterone.  相似文献   

7.
The mouse preadipocyte 3T3-L1 line is the most useful cell line for the study of adipocytes. Adipocytes secrete adipocytokines, and abnormal adipocytokine production can cause the metabolic syndrome. Although it is important to understand the characteristics of mouse adipocytokine secretion, it is difficult to quantify these products because they are produced in low concentrations. Here, we developed a highly sensitive enzyme-linked immunosorbent assay (ELISA) for detecting the concentrations of mouse adipocytokines, such as TNFα and leptin. In this method, the antigen was sandwiched by using goat- and rabbit-derived polyclonal antibodies, and the fluorescence intensity produced in the reaction with 4-methylumbelliferyl-β-galacto-sidase pyranosidase (MUG) was measured. TNFα and leptin could be measured at concentrations as low as approximately 1 pg/ml. By using our ELISA method, we also measured the concentrations of TNFα and leptin in mouse 3T3-L1 preadipocytes and adipocytes. The differentiation of preadipocytes into adipocytes enhanced TNFα production and secretion and reduced the leptin production. The amount of TNFα produced in the adipocytes was 3.0 ng/mg-protein; this amount was considerably higher than that of leptin.  相似文献   

8.
A double-antibody sandwich, enzyme-linked immunosorbent assay has been developed for phytochrome in Avena sativa L. cv. Saladin. An immunoglobulin fraction of rabbit antiserum raised to 118 kdalton phytochrome was used with alkaline phosphatase as the enzyme label. The assay detected as little as 0.2 ng phytochrome in extracts of dark-grown plant material. No evidence for specific or non-specific measurement of proteins other than phytochrome was found. The assay detected phytochrome in extracts of Avena grown in the light. Dilution curves for light-grown phytochrome extracts had a reduced slope and saturated at a lower level of enzyme activity than those for dark extracts. These differences were not caused by an inhibitor in extracts from light-grown plants. Phytochromes from dark- and light-grown plants may be immunologically different.  相似文献   

9.
The development of an enzyme-linked immunosorbent assay (ELISA) for uridine 5'-diphospho-N-acetyl-glucosamine: alpha mannoside beta 1----6 N-acetylglucosaminyltransferase (GnT-V) is reported. The assay quantitates the enzymatic conversion of the specific synthetic GnT-V acceptor GlcNAc beta 1----2Man alpha 1----6Man beta-R (5) to the product GlcNAc beta 1----2[GlcNAc-beta 1----6]Man alpha 1----6Man beta-R (6) when these oligosaccharide structures were covalently attached to bovine serum albumin which was then coated on microtiter wells. Conversion of 5 to 6 was detected using a polyclonal antiserum raised against the product 6 and from which antibodies cross-reacting with acceptor 5 had been removed by affinity adsorption. GnT-V activity detected by ELISA was linearly proportional to both enzyme concentration and time under appropriate experimental conditions where 50-300 fmol of product was formed per microtiter well. GnT-V activity could be measured by ELISA in Triton X-100 extracts of hamster kidney acetone powder and in human serum. The twofold increase in GnT-V activity which is known to accompany Rous sarcoma virus transformation of baby hamster kidney cells could also be quantitated using the ELISA.  相似文献   

10.
11.
Click chemistry is explored as a potential cost-effective and selective immobilization method for the production of an enzyme-linked immunosorbent assay (ELISA). Coatings were formulated containing either a terminal alkyne or a bicyclo[6.1.0]non-4-yne (BCN) chemical handle, and a diagnostic peptide was subsequently immobilized onto these coatings by the copper-catalyzed azide-alkyne 1,3-dipolar cycloaddition (CuAAC) or copper-free strain-promoted azide-alkyne 1,3-dipolar cycloaddition (SPAAC), respectively. The terminal alkyne-containing coating showed high background levels in subsequent ELISA's due to the copper catalyst used in the immobilization step. The BCN-containing coating, however, was successfully employed and presents a cost-effective alternative to existing (strept)avidin-biotin immobilization methods. This technology was illustrated with an ELISA used for the diagnosis of rheumatoid arthritis (RA) but could be easily applied to a wide range of diagnostic tests.  相似文献   

12.
In this study, a highly sensitive capillary-based enzyme-linked immunosorbent assay (ELISA) has been developed for the analysis of picomolar levels of thrombin-cleaved osteopontin (trOPN), a potential biomarker for ischemic stroke, in human plasma. Using a square capillary coated with 8.5 μg/ml anti-human trOPN capture antibody for ELISA, the linear range obtained was 2 to 16 pM trOPN antigen. This concentration range was in the detection window of trOPN antigen in plasma samples. Compared with the conventional microplate-based ELISA, the current capillary technique significantly reduced the amounts of reagent from milliliter to microliter, reduced the analysis time from 8 to 3 h, and had a better sensitivity and detection limit performance from approximately 50 pM down to 2 pM of trOPN antigen. These results indicate that this capillary-based immunoassay is a potential tool for biomarker detection and may be useful in clinical trials and medical diagnostic applications.  相似文献   

13.
A competitive indirect enzyme-linked immunosorbent assay (ELISA) was developed for the detection of zearalenone, an estrogenic mycotoxin. Zearalenone was converted to zearalenone-6'-carboxymethyloxime and conjugated to bovine serum albumin and poly-L-lysine for use as immunogen and solid-phase marker, respectively. Immunization of rabbits with the bovine serum albumin conjugate resulted in zearalenone antibody titers of 20,480 in 11 weeks. A competitive indirect ELISA was conducted by simultaneously incubating zearalenone with zearalenone antiserum over zearalenone-6'-carboxymethyloxime poly-L-lysine solid phase and then determining the bound rabbit immunoglobulin with goat anti-rabbit peroxidase conjugate. Response range for zearalenone in the resulting competition curve was between 1 and 50 ng/ml. Reactivities of this antiserum for alpha-zearalenol, beta-zearalenol, alpha-zearalanol, and beta-zearalanol were, respectively, 50, 12, 6, and 3% of that found for zearalenone. By using the competitive indirect ELISA, zearalenone was detectable in methanol-water extracts of corn, wheat, and pig feed samples.  相似文献   

14.
A simple enzyme-linked immunosorbent assay (ELISA) for sex hormone-binding globulin (SHBG) has been developed. Polyclonal antibody raised to SHBG purified to homogeneity was employed. The ELISA, which may be performed in under 4 h, shows no cross-reactivity with other serum proteins, has a sensitivity of less than 1.2 fmol per sample, demonstrates excellent correlation with ligand-binding techniques (r = 0.996; p less than 0.0001), and has intra- and inter-assay coefficients of variation of between 5-9% and 7-11% respectively.  相似文献   

15.
Human plasma contains at least three forms of adiponectin: a trimer, a hexamer, and a high-molecular-weight (HMW) multimer. We purified HMW adiponectin from human plasma using its affinity to gelatin and obtained monoclonal antibodies against it. On Western blot analysis, the reactivity of these monoclonal antibodies was shown to be restricted to a non-heat-denatured form of adiponectin molecules. On heating, the collagen-like domain of adiponectin molecules became denatured, and thus the trimer form could not be maintained. From these, monoclonal antibodies against HMW adiponectin were suggested to react with the intact trimer of adiponectin. With these monoclonal antibodies, we developed a sandwich ELISA system for quantifying adiponectin in human serum. Its specificity was verified by analysis of serum fractions separated by gel-filtration chromatography, and our ELISA system was found to be HMW adiponectin-specific. With this novel ELISA, the HMW adiponectin concentrations were 8.4 +/- 5.5 microg/ml (mean +/- SD) in healthy women and 6.2 +/- 3.6 microg/ml in healthy men. Also, serum with a lower HMW adiponectin concentration was shown to have a lower HMW ratio (i.e., HMW adiponectin/total adiponectin).  相似文献   

16.
A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
A sensitive and specific competitive enzyme-linked immunosorbent assay (ELISA) for rat prolactin was developed using reagents from the National Institute of Arthritis, Diabetes, Digestive Diseases and Kidney. In this assay soluble prolactin and prolactin adsorbed to a solid-phase support compete for rabbit anti-prolactin antibody binding sites. Therefore, a high concentration of soluble prolactin in the sample will result in a low concentration of antibody immobilized to the adsorbed prolactin. The immobilized antibody-prolactin complex is detected and quantified using goat anti-rabbit immunoglobulin G covalently conjugated to the enzyme horseradish peroxidase. Assay parameters were optimized by investigating the concentration of reagents and the reaction kinetics in each of the assay steps. The assay can be performed in 24 h. A sensitivity range of 0.06 to 6 ng in the region of 90 to 10% binding was obtained. Near 50% binding (0.6 ng), the intraassay coefficient of variation (CV) was 4.2% and the interassay CV was 7.6%. The correlation between radioimmunoassay and the ELISA was 0.868. Selected applications of the assay are described. The assay should prove a useful alternative to the radioimmunoassay in those instances where steps involving the use of 125I become limiting, for example, iodination facility and gamma counter availability or prolonged reagent storage.  相似文献   

18.
19.
Summary A model peptide antigen derived from HCV Core protein was modified by a hydrophilic glyoxylamide arm using a tartaramide-based linker and used in an enzyme-linked immunosorbent assay (ELISA) on hydrazide plates. A comparative study with the standard non-covalent adsorption procedures demonstrated a large gain in sensitivity for the detection of antibodies in HCV-positive sera.  相似文献   

20.
A model peptide antigen derived from HCV Coreprotein was modified by a hydrophilic glyoxylamide arm using atartaramide-based linker and used in an enzyme-linkedimmunosorbent assay (ELISA) on hydrazide plates. A comparativestudy with the standard non-covalent adsorption proceduresdemonstrated a large gain in sensitivity for the detection ofantibodies in HCV-positive sera.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏