首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The transverse electromagnetic (TEM) cell system developed by Litovitz et al. and utilized by Penafiel et al. for the exposure of cells in T25 flasks at 835 MHz has been reevaluated for the purpose of replicating the studies published by Penafiel. The original setup has been reconstructed as closely as possible, with improvements enabling blinded exposures, forced cooling and better repeatable positioning of the flasks, as well as tight exposure and environmental parameter control. The signal unit can simulate the original signal but also enables various other exposure schemes. The setup has been evaluated for four T25 flasks filled with 5 and 10 ml of cell medium by experimental and numerical means. Comparing E field, SAR and temperature measurements resulted in good agreement: <0.4 dB (4.5%) for E field and 0.48 dB (10.5%) for SAR. The overall average SAR within the medium is 6.0 W/kg at 1 W input power with a standard deviation of less than 52%. The temperature increase was determined to be 0.13 degrees C/(W/kg). This can be reduced to 0.045 degrees C/(W/kg) by applying active air flow cooling. The comparison of SAR values from temperature measurements with the corresponding simulated values resulted in excellent agreement. These results do not correspond to the previous study reporting an average SAR within the medium of 2.5 W/kg at an input power of 0.96 W.  相似文献   

2.
Nine small radiation shields made to adhere to the case of mobile phones were tested at 914 and 1880 MHz. Five popular products were tested because advertisements typically claim they are up to 99% effective in blocking radio frequency (RF) radiation emitted from mobile phones. Also, four other conceptually unusual products were tested because advertisements typically claim they emit oscillations that counteract the RF radiation from mobile phones. Each shield was tested on the same mobile phone, and measurements were made to compare the absorption of RF energy in the head with and without each shield attached to the phone. The phone was positioned against a head model, and an automated measurement process was used to determine specific absorption rate (SAR) in the same way it is used at Motorola to test the compliance of mobile phones with respect to human exposure limits. The location of the peak SAR was not observed to change with any of the shields attached to the phone, and the 1 g, peak spatial average SAR did not change by any statistically significant amount. These results indicate the small shields are ineffective in reducing the exposure of the head to RF energy emitted by a mobile phone.  相似文献   

3.
Human exposure by mobile phones in enclosed areas such as train carriages, elevators, and cars is considered. Equivalent power density and whole body specific absorption rate (SAR) are estimated by applying multimode resonant cavity theory and a straight forward worst case approach. The results show that exceeding the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines due to simultaneous use of several mobile phones in enclosed areas is highly improbable.  相似文献   

4.
The main objective of this paper is to carefully study the fields induced in flasks exposed to RF electromagnetic fields. The study focuses on the widely used 60 mm Petri dishes and rectangular T-75 flasks for the two following cases: 1) cells in homogeneous suspension and 2) cell monolayers. The dependence of the coupling and the homogeneity of the SAR distribution on frequency (0.7 GHz to 2.5 GHz), polarization (E, H and k polarizations) and the amount of medium (1.9 mm to 4.7 mm medium height) is studied. In addition, the effects of the environment, meniscus and field impedance as well as the distortion of the incident field are discussed. Based on these results, advantages and disadvantages of different fundamental designs of apparatus used in the past are compared. These are TEM cells, HF chambers, radial transmission lines (RTL), waveguides and wire patch cells. Furthermore, the major optimization parameters are identified for the development of highly optimized exposure systems, enabling the conduct of high quality experiments.  相似文献   

5.
The so-called carousel setup has been widely utilized for testing the hypotheses of adverse health effects on the central nervous system (CNS) due to mobile phone exposures in the frequency bands 800-900 MHz. The objectives of this article were to analyze the suitability of the setup for the upper mobile frequency range, i.e., 1.4-2 GHz, and to conduct a detailed experimental and numerical dosimetry for the setup at the IRIDIUM frequency band of 1.62 GHz. The setup consists of a plastic base on which ten rats, restrained in radially positioned tubes, are exposed to the electromagnetic field emanating from a sleeved dipole antenna at the center. Latest generation miniaturized dosimetric E field and temperature probes were used to measure the specific absorption rate (SAR) inside the brain of three rat cadavers of the Lewis strain and two rat cadavers of the Fisher 344 strain. A numerical analysis was conducted on the basis of three numerical rat phantoms with voxel sizes between 1.5 and 0.125 mm3 that are based on high resolution MRI scans of a 300 g male Wistar rat and a 370 g male Sprague-Dawley rat. The average of the assessed SAR values in the brain was 2.8 mW/g per W antenna input power for adult rats with masses between 220 and 350 g and 5.3 mW/g per W antenna input power for a juvenile rat with a mass of 95 g. The strong increase of the SAR in the brain with decreasing animal size was verified by simulations of the absorption in numerical phantoms scaled to sizes between 100 and 500 g with three different scaling methods. The study also demonstrated that current rat phantom models do not provide sufficient spatial resolution to perform absolute SAR assessment for the brain tissue. The variation of the SAR(brain)(av) due to changes in position was assessed to be in the range from +15% to -30%. A study on the dependence of the performance of the carousel setup on the frequency revealed that efficiency, defined as SAR(brain)(av) per W antenna input power, and the ratio between SAR(brain)(av) and SAR(body)(av) are optimal in the mobile communications frequency range, i.e., 0.8-3 GHz.  相似文献   

6.
With the increasing use of mobile communication, concerns have been expressed about the possible interactions of electromagnetic radiation with the human organism and, in particular, the brain. The effects on neuronal electrical activity, energy metabolism, genomic responses, neurotransmitter balance, blood-brain barrier permeability, cognitive function, sleep, and various brain diseases including brain tumors are reviewed. Most of the reported effects are small as long as the radiation intensity remains in the nonthermal range, and none of the research reviewed gives an indication of the mechanisms involved at this range. However, health risks may evolve from indirect consequences of mobile telephony, such as the sharply increased incidence rate of traffic accidents caused by telephony during driving, and possibly also by stress reactions which annoyed bystanders may experience when cellular phones are used in public places. These indirect health effects presumably outweigh the direct biological perturbations and should be investigated in more detail in the future.  相似文献   

7.
8.
9.
The effect of acute exposure to radio frequency electromagnetic fields (RF EMF) generated by mobile phones on an auditory threshold task was investigated. 168 participants performed the task while exposed to RF EMF in one testing session (either global system for mobile communication (GSM) or unmodulated signals) while in a separate session participants were exposed to sham signals. Lateralization effects were tested by exposing participants either on the left side or on the right side of the head. No significant effect of exposure to RF EMF was detected, suggesting that acute exposure to RF EMFs does not affect performance in the order threshold task.  相似文献   

10.
11.
The increasing deployment of mobile communication base stations led to an increasing demand for epidemiological studies on possible health effects of radio frequency emissions. The methodological challenges of such studies have been critically evaluated by a panel of scientists in the fields of radiofrequency engineering/dosimetry and epidemiology. Strengths and weaknesses of previous studies have been identified. Dosimetric concepts and crucial aspects in exposure assessment were evaluated in terms of epidemiological studies on different types of outcomes. We conclude that in principle base station epidemiological studies are feasible. However, the exposure contributions from all relevant radio frequency sources have to be taken into account. The applied exposure assessment method should be piloted and validated. Short to medium term effects on physiology or health related quality of life are best investigated by cohort studies. For long term effects, groups with a potential for high exposure need to first be identified; for immediate effect, human laboratory studies are the preferred approach.  相似文献   

12.
The use of mobile phone telecommunication has increased in recent years. In parallel, there is growing concern about possible adverse health effects of cellular phone networks. We used personal dosimetry to investigate the association between exposure to mobile phone frequencies and well-being in adults. A random population-based sample of 329 adults living in four different Bavarian towns was assembled for the study. Using a dosimeter (ESM-140 Maschek Electronics), we obtained an exposure profile over 24 h for three mobile phone frequency ranges (measurement interval 1 s, limit of determination 0.05 V/m). Exposure levels over waking hours were totalled and expressed as mean percentage of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference level. Each participant reported acute symptoms in a day-long diary. Data on five groups of chronic symptoms and potential confounders were assessed during an interview. The overall exposure to high-frequency electromagnetic fields was markedly below the ICNIRP reference level. We did not find any statistically significant association between the exposure and chronic symptoms or between the exposure and acute symptoms. Larger studies using mobile phone dosimetry are warranted to confirm these findings.  相似文献   

13.
14.
The aim of this study was to design, implement and analyze a space-efficient setup for the whole-body exposure of unrestrained Wistar rats to radiofrequency (RF) electromagnetic fields at 900 MHz. The setup was used for 2 years in a cocarcinogenesis study and part of it for 5 weeks in a central nervous system (CNS) study. Up to 216 rats could be placed in separate cages in nine different exposure chambers on three racks requiring only 9 m2 of floor area (24 rats per m2). Chambers were radial transmission lines (RTL), where the rats could freely move in their cages where food and drinking water was provided ad libitum except during RF exposure periods. Dosimetrical analysis was based on FDTD computations with heterogeneous rat models and was validated with calorimetrical measurements carried out with homogeneous phantoms. The estimated whole-body average specific absorption rates (SAR) of rats were 0 (sham), 0.4, and 1.3 W/kg in the cocarcinogenesis study and 0 (sham), 0.27, and 2.7 W/kg in the CNS study with an estimated uncertainty of 3 dB (K = 2). The instantaneous and lifetime variations of whole-body average SAR due to the movement of rats were estimated to be 2.3 and 1.3 dB (K = 1), respectively.  相似文献   

15.
The aim of this project was to develop an animal exposure system for the biological effect studies of radio frequency fields from handheld wireless telephones, with energy deposition in animal brains comparable to those in humans. The finite‐difference time‐domain (FDTD) method was initially used to compute specific absorption rate (SAR) in an ellipsoidal rat model exposed with various size loop antennas at different distances from the model. A 3 × 1 cm rectangular loop produced acceptable SAR patterns. A numerical rat model based on CT images was developed by curve‐fitting Hounsfield Units of CT image pixels to tissue dielectric properties and densities. To design a loop for operating at high power levels, energy coupling and impedance matching were optimized using capacitively coupled feed lines embedded in a Teflon rod. Sprague Dawley rats were exposed with the 3 × 1 cm loop antennas, tuned to 837 or 1957 MHz for thermographically determined SAR distributions. Point SARs in brains of restrained rats were also determined thermometrically using fiberoptic probes. Calculated and measured SAR patterns and results from the various exposure configurations are in general agreement. The FDTD computed average brain SAR and ratio of head to whole body absorption were 23.8 W/kg/W and 62% at 837 MHz, and 22.6 W/kg/W and 89% at 1957 MHz. The average brain to whole body SAR ratio was 20 to 1 for both frequencies. At 837 MHz, the maximum measured SAR in the restrained rat brains was 51 W/kg/W in the cerebellum and 40 W/kg/W at the top of the cerebrum. An exposure system operating at 837 MHz is ready for in vivo biological effect studies of radio frequency fields from portable cellular telephones. Two‐tenths of a watt input power to the loop antenna will produce 10 W/kg maximum SAR, and an estimated 4.8 W/kg average brain SAR in a 300 g medium size rat. Bioelectromagnetics 20:75–92, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

16.
Compliance with the established exposure limits for the electric field (E‐field) induced in the human brain due to low‐frequency magnetic field (B‐field) induction is demonstrated by numerical dosimetry. The objective of this study is to investigate the dependency of dosimetric compliance assessments on the applied methodology and segmentations. The dependency of the discretization uncertainty (i.e., staircasing and field singularity) on the spatially averaged peak E‐field values is first determined using canonical and anatomical models. Because spatial averaging with a grid size of 0.5 mm or smaller sufficiently reduces the impact of artifacts regardless of tissue size, it is a superior approach to other proposed methods such as the 99th percentile or smearing of conductivity contrast. Through a canonical model, it is demonstrated that under the same uniform B‐field exposure condition, the peak spatially averaged E‐fields in a heterogeneous model can be significantly underestimated by a homogeneous model. The frequency scaling technique is found to introduce substantial error if the relative change in tissue conductivity is significant in the investigated frequency range. Lastly, the peak induced E‐fields in the brain tissues of five high‐resolution anatomically realistic models exposed to a uniform B‐field at ICNIRP and IEEE reference levels in the frequency range of 10 Hz to 100 kHz show that the reference levels are not always compliant with the basic restrictions. Based on the results of this study, a revision is recommended for the guidelines/standards to achieve technically sound exposure limits that can be applied without ambiguity. Bioelectromagnetics 34:375–384, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

17.
18.
19.
Abstract

The biochemical status in the saliva of 12 males before/after using mobile phone has been evaluated. Radio frequency signals of 1800 MHz (continuous wave transmission, 217?Hz modulate and Global System for Mobile Communications [GSM – non-DTX]) with 1.09 w/kg specific absorption rate (SAR) value were used for 15 and 30?min. Cell phone radiation induced a significant increase of superoxide dismutase (SOD); there was a statistically significant effect of talking time on the levels of SOD, F(2, 33)?=?8.084, p?<?0.05, ω?=?0.53. The trend analysis suggests a significant quadratic trend, F(1, 33)?=?4.891, p?<?0.05; indicating that after 15?min of talking the levels of SOD increased, but as talking time increased the SOD activity started to drop. In contrast to this, there was no statistically significant effect of talking time on the level of salivary albumin, cytochrome c, catalase or uric acid. Results suggest that exposure to electromagnetic radiation may exert an oxidative stress on human cells as evidenced by the increase in the concentration of the superoxide radical anion released in the saliva of cell phone users.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号