首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
本文介绍了光纤生物传感器的原理,对光纤传感器制作中的工程学和生物学问题进行了探讨并概述了它的应用情况。  相似文献   

2.
3.
A new optical design uses a liquid crystal pixel array (LCPA) to discriminate multiple fluorescence signals on a two-dimensional biosensor array. The LCPA can selectively control the transmission of fluorescence generated from multiple biosensing elements on a planar waveguide. This device sequentially acquires the fluorescence data from the substrate by making multiple individual measurements of the sensing elements on the waveguide. The biosensing elements are patterned according to the pixel layout of the LCPA and optically aligned so that each electronically driven pixel can either transmit or filter out the fluorescence signal as specified by the user. The primary advantage of this system is that a single detection channel (i.e. photomultiplier tube (PMT)) can be used to measure multiple fluorescence signals from a two-dimensional substrate while the LCPA provides for spatial resolution. We evaluate the performance of the LCPA by testing the optical homogeneity of the liquid crystal pixels and linear dynamic range for transmitting light. The LCPA is also used with well-developed biosensing chemistry modified for this optical format.  相似文献   

4.
A new transducer for biosensor applications has been developed based on a three-dimensional interdigitated electrode array (IDEA) with electrode digits separated by an insulating barrier. Binding of molecules to a chemically modified surface of the transducer induces important changes in conductivity between the electrodes. Three-dimensional sensor shows considerable improvement compared with a standard planar IDEA design. The potential of the developed device as a sensor transducer to detect immunochemical and enzymatic reactions, as well as DNA hybridization events is demonstrated. The immunosensor allows direct detection of the antibiotic sulfapyridine and shows the IC(50) parameter value of 5.6 microgL(-1) in a buffer. Immunochemical determination occurs under competitive configurations and without the use of any label. Each modified sensor is of a single use. Nevertheless, biochemical reagents can be easily cleaned off the sensor surface for its reuse. Layer-by-layer method of used to deposit polyethyleneimine and glucose oxidase showed that the sensor is also highly effective for detecting single and multilayered molecular assemblies.  相似文献   

5.
Three microalgal species (Dictyosphaerium chlorelloides (D.c.), Scenedesmus intermedius (S.i.) and Scenedesmus sp. (S.s.)) were encapsulated in silicate sol–gel matrices and the increase in the amount of chlorophyll fluorescence signal was used to quantify simazine. Influence of several parameters on the preparation of the sensing layers has been evaluated: effect of pH on sol–gel gelation time; effect of algae density on sensor response; influence of glycerol (%) on the membrane stability. Long term stability was also tested and the fluorescence signal from biosensors remained stable for at least 3 weeks. D.c. biosensor presented the lowest detection limits for simazine (3.6 μg L−1) and the broadest dynamic calibration range (19–860 μg L−1) with IC50 125 ± 14 μg L−1. Biosensor was validated by HPLC with UV/DAD detection. The biosensor showed response to those herbicides that inhibit the photosynthesis at photosystem II (triazines: simazine, atrazine, propazine, terbuthylazine; urea based herbicides: linuron). However, no significant increases of fluorescence response was obtained for similar concentrations of 2,4-D (hormonal herbicide) or Cu(II). The combined use of two biosensors that use two different genotypes, sensitive and resistant to simazine, jointly allowed improving microalgae biosensor specificity.  相似文献   

6.
A novel amperometric biosensor based on polypyrrole (PPy) nanotube array deposited on a Pt plated nano-porous alumina substrate and its performances are described. Glucose oxidase (GOx) enzyme was selected as the model enzyme in this study. Commercially available nano-porous alumina discs were used to fabricate electrodes in order to study the feasibility of enzyme entrapment by physical adsorption. A PPy/PF6- film comprising of nanotube array was synthesized using a solution containing 0.05 M Pyrrole and 0.1 M NaPF6 at a current density of 0.3 mA/cm2 for 90 s. The immobilization was done by physical adsorption of 5 microL of GOx (from a stock solution of 2 mg/mL of 210 U/mg) on each electrode. A sensitivity of 7.4 mA cm(-2) M(-1) was observed with PPy nanotube array where the maximum tube diameter was 100 nm. A linear range of 500 microM-13 mM and a response time of about 3 s were observed with a nanotube array where the maximum tube diameter was 200 nm. The synthesized nanotube arrays were characterized by galvanostatic electrochemical technique. Calculated value of apparent Michaelis-Menten constant (Km) was 7.01 mM. The use of nano-porous template electrodes leads to an efficient enzyme loading and provides an increased surface area for sensing the reaction. These factors contribute to increase the characteristic performances of the novel biosensor.  相似文献   

7.
Fiber optic evanescent wave immunosensors for medical diagnostics.   总被引:1,自引:0,他引:1  
Immunodiagnostic sensors permit sensitive measurement of a wide variety of both high and low molecular mass analytes--serum analytes may be detected at picomolar concentrations. Due to the sensor monitoring antigen--antibody reactions directly, quantitative results are available within seconds to minutes of sample introduction. In recent years, the trend has been for immunodiagnostics to be used at sites away from centralized medical laboratories. Specific requirements associated with such use are being achieved by the development of optical devices incorporating evanescent wave sensors.  相似文献   

8.
The measurement of individual respiratory parameters in the vicinity of the lungs remains an unresolved problem in the areas of anesthesia and intensive care medicine. New technologies such as fibreoptic technology, which meet the extreme demands of medical sensor applications, and their innovative potential as a basis for the development of marketable products, appear promising. This is illustrated by the fundamental principles developed for a sensor-armed tracheal tube for on-line monitoring of ventilated patients.  相似文献   

9.
An optical array biosensor encapsulated with hydrolase and oxidoreductase using sol-gel immobilization technique has been fabricated for simultaneous analysis and screening of multiple samples to determine the presence of multianalytes which are clinically important in relation to renal failure. Urease and creatinine deiminase were used to detect urea and creatinine, while glucose oxidase and uricase were coimmobilized with horseradish peroxidase to quantify glucose and uric acid. Moreover, the concentrations of analytes in fetal calf serum were measured and quantified using the developed sensing system. The array biosensor showed good specificity for the simultaneous analysis of multiple samples for multianalytes without obvious cross-interference. The analytical ranges of the four analytes were between 0.01 and 10mM with detection limits of 2.5-80 microM. High precision with relative standard deviations of 3.8-9.2% (n=45) was also demonstrated. The reproducibility of array-to-array in 3 consecutive months was 5.4% (n=3). Moreover, the concentrations of analytes in fetal calf serum were 5.9 mM for urea, 0.13 mM for creatinine, 3.3mM for glucose, and 0.15 mM for uric acid, which were in good agreement with results obtained using the traditional spectroscopic methods. These results demonstrate the first use of a sol-gel-derived optical array biosensor for simultaneous analysis of multiple samples for the presence of multiple clinically important renal analytes.  相似文献   

10.
Fiber optic in vivo imaging in the mammalian nervous system   总被引:4,自引:0,他引:4  
The compact size, mechanical flexibility, and growing functionality of optical fiber and fiber optic devices are enabling several new modalities for imaging the mammalian nervous system in vivo. Fluorescence microendoscopy is a minimally invasive fiber modality that provides cellular resolution in deep brain areas. Diffuse optical tomography is a non-invasive modality that uses assemblies of fiber optic emitters and detectors on the cranium for volumetric imaging of brain activation. Optical coherence tomography is a sensitive interferometric imaging technique that can be implemented in a variety of fiber based formats and that might allow intrinsic optical detection of brain activity at a high resolution. Miniaturized fiber optic microscopy permits cellular level imaging in the brains of behaving animals. Together, these modalities will enable new uses of imaging in the intact nervous system for both research and clinical applications.  相似文献   

11.

Background

Although Monte Carlo simulations of light propagation in full segmented three-dimensional MRI based anatomical models of the human head have been reported in many articles. To our knowledge, there is no patient-oriented simulation for individualized calibration with NIRS measurement. Thus, we offer an approach for brain modeling based on image segmentation process with in vivo MRI T1 three-dimensional image to investigate the individualized calibration for NIRS measurement with Monte Carlo simulation.

Methods

In this study, an individualized brain is modeled based on in vivo MRI 3D image as five layers structure. The behavior of photon migration was studied for this individualized brain detections based on three-dimensional time-resolved Monte Carlo algorithm. During the Monte Carlo iteration, all photon paths were traced with various source-detector separations for characterization of brain structure to provide helpful information for individualized design of NIRS system.

Results

Our results indicate that the patient-oriented simulation can provide significant characteristics on the optimal choice of source-detector separation within 3.3 cm of individualized design in this case. Significant distortions were observed around the cerebral cortex folding. The spatial sensitivity profile penetrated deeper to the brain in the case of expanded CSF. This finding suggests that the optical method may provide not only functional signal from brain activation but also structural information of brain atrophy with the expanded CSF layer. The proposed modeling method also provides multi-wavelength for NIRS simulation to approach the practical NIRS measurement.

Conclusions

In this study, the three-dimensional time-resolved brain modeling method approaches the realistic human brain that provides useful information for NIRS systematic design and calibration for individualized case with prior MRI data.  相似文献   

12.
Measurements of pollutants such as toluene are critical for the characterization of contaminated sites and for the monitoring of remediation processes and wastewater treatment effluents. Fiber optic enzymatic biosensors have the potential to provide cost-effective, real time, continuous, in situ measurements. In this study, a fiber optic enzymatic biosensor was constructed and characterized for the measurement of toluene concentrations in aqueous solutions. The biological recognition element was toluene ortho-monooxygenase (TOM), expressed by Escherichia coli TG1 carrying pBS(Kan)TOM, while an optical fiber coated with an oxygen-sensitive ruthenium-based phosphorescent dye served as the transducer. Toluene was detected based on the enzymatic reaction catalyzed by TOM, which resulted in the consumption of oxygen and changes in the phosphorescence intensity. The biosensor was found to have a limit of detection of 3 μM, a linear signal range up to 100 μM, and a response time of 1 h. The performance was reproducible with different biosensors (RSD=7.4%, n=8). The biosensor activity declined with each measurement and with storage time, particularly at elevated temperatures. This activity loss could be partially reversed by exposure to formate, suggesting that NADH consumption was the primary factor limiting lifetime. This is the first report of an enzymatic toluene sensor and of an oxygenase-based biosensor. Since many oxygenases have been reported, the design concept of this oxygenase-based biosensor has the potential to broaden biosensor applications in environmental monitoring.  相似文献   

13.
14.
A novel optical biosensor for homogeneous immunoassay has been developed on the basis of the finding that electrochemical luminescence of pyrene-labelled antigen is extremely inhibited by immunochemical complexation. Electrochemical luminescence homogeneous immunoassay for human serum albumin (HSA), as a model analyte, was performed with a platinum plate electrode which was located in the vicinity of an optical fibre tip. HSA was determined in the concentration range of 3–25 × 10?6 mol/I. To improve electrochemical luminescence measurement an optical fibre electrode has been developed by fabricating a transparent platinum film on the top of an optical fibre. The minimum detectable limit of luminol was 10?11 mol/l with the optical fibre electrode. Luminol was applied as a label for homogeneous immunoassay.  相似文献   

15.
Different types of optical biosensor are critically assessed and compared, based on the belief that a comprehensive understanding of their possibilities—and limitations—is needed for their successful exploitation. © 1997 John Wiley & Sons, Ltd.  相似文献   

16.
The electrochemistry of redox proteins is now well established. Conditions exist which allow electron-transfer reactions of all simple proteins to proceed rapidly and reversibly at electrodes. Coupling of the electrode reaction to enzymes, for which the redox proteins act as cofactors, allows exploitation of this good electrochemistry. This is well illustrated by the enzyme-catalysed electrochemical oxidation of p-cresol to p-hydroxybenzaldehyde, which has been shown to proceed along with coupling to the electrode via the copper protein, azurin, or the organometallic compound ferroceneboronic acid. Ferrocene derivatives, in general, show a degree of versatility, coupling the electron-transfer reactions of many enzymes. Thus derivatives of the ferricinium ion act as excellent electron-transfer reagents from the enzyme glucose oxidase. The system is capable of detecting glucose in blood. Similar procedures, in conjunction with the appropriate enzyme, have yielded assays for, among others, H2O2 and cholesterol.  相似文献   

17.
The biosensor field has grown enormously since the first demonstration of the biosensor concept by Leland C. Clark, Jr. in 1962. Today's biosensor market is dominated by glucose biosensors, mass-produced enzyme electrodes for the rapid self-diagnosis of blood glucose levels by diabetes sufferers. Here we take a historical look at the inception, growth, and development of the enzyme biosensor field from a commercial viewpoint. The current status of the technology is evaluated and future trends in this dynamic and fastmoving field are also anticipated.  相似文献   

18.
Mediated biosensors   总被引:7,自引:0,他引:7  
Direct electrode transfer between enzyme and the electrode in biosensors requires high efficiency therefore, synthetic replacement for oxygen led to the development of enzyme mediators and modified electrodes in biosensor fabrication. In this context, a number of electron acceptors and complexes have been used. Present paper gives an overview of various methodologies involved in the mediated systems, their merits and wide applications.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号