首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases.  相似文献   

2.
We developed an isotope dilution HPLC-atmospheric pressure chemical ionization-tandem mass spectrometry (HPLC-APCI-MS/MS) method for the simultaneous determination of p-tyrosine, phenylalanine, o,o'-dityrosine, m-tyrosine, o-tyrosine, 3-chlorotyrosine and 3-nitrotyrosine and 8-hydroxy-2'-deoxyguanosine (8-OHdG) that requires no extensive sample pre-treatment. p-[(2)H(4)]Tyrosine and o,o'-[(2)H(6)]dityrosine were used as internal standards. Calibration curves of the method were linear (r(2)=0.990-0.999) over a concentration range of 0.03-10 microM for o-tyrosine; 0.04-10 microM for 3-nitrotyrosine and 3-chlorotyrosine; 0.05-10 microM for o,o'-dityrosine; and for m-tyrosine; 1.0-100 microM for p-tyrosine and for phenylalanine; and 0.01-10 microM for 8-OHdG. The detection limits were from 0.025 to 0.05 microM for the tyrosine derivatives; 0.01 microM for 8-OHdG; and 0.5 microM for p-tyrosine and for phenylalanine, respectively. Within-day coefficients of variation (CV) for spiked human urine samples ranged from 2.7 to 7.0%, except for 8-OHdG (13.7%). Between-day variations ranged from 7.9 to 13.0%, except for o-tyrosine (CV = 18.2%), and for 8-OHdG (CV = 24.7%).The background levels of p-tyrosine, phenylalanine, o,o'-dityrosine, and o-tyrosine in morning urine of eight healthy volunteers were 3890+/-590, 3420+/-730, 5.8+/-0.3, and 9.2+/-1.5 micromol/mol creatinine, respectively. Using the present HPLC-APCI-MS/MS method, the urinary background levels of m-tyrosine, 3-chlorotyrosine, 3-nitrotyrosine and 8-OHdG were below the limit of detection.  相似文献   

3.
The paper describes a method for the sensitive and selective determination of zearalenone and its metabolites in urine, plasma and faeces of horses by high performance liquid chromatography and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS). While only one step sample clean-up by an immunoaffinity column (IAC) was sufficient for plasma samples, urine and faeces samples had to be prepared by a combination of a solid-phase extraction (SPE) and an immunoaffinity column. The method allows the simultaneous determination of zearalenone and all of its metabolites; alpha-zearalenol, beta-zearalenol, alpha-zearalanol, beta-zearalanol and zearalanone. Dideuterated zearalanone was used as internal standard for quantification and the study of the matrix effect. Recovery rates between 56 and slightly above 100% were achieved in urine samples, and more than 80% in plasma and faeces samples. The limits of detection ranged from 0.1-0.5 microg/l or microg/kg, the limits of quantification from 0.5-1.0 microg/l or microg/kg. The practical use of the method is demonstrated by the analysis of spiked and naturally contaminated urine, plasma and faeces of horses.  相似文献   

4.
Abstract Background. Measurement of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) has recently become more popular as a means of assessing oxidative stress in the human body. The aim of this study is to compare the levels of urine 8-OHdG in patients with type 2 diabetes with and without nephropathy and to evaluate its role as a biochemical marker for distinguishing these patients from healthy and patients without complications. Methods. For this purpose, 52 patients with type 2 diabetes mellitus (32 with nephropathy (DMN), 20 without nephropathy (DM)) and 20 healthy control subjects (C) were included in this study. The urine concentrations of 8-OHdG were measured by modified LC-MS/MS method and compared with the first morning voiding urine albumin/creatinine ratio (UACR) and HbA1c values of the same patients. Results. The concentrations of urine 8-OHdG in DMN and DM patients were higher than those of the control subjects (3.47?±?0.94, 2.92?±?1.73, 2.1?±?0.93 nmol/mol creatinine, respectively). But there was no statistical difference between DMN and DM (p =?0.115). There is significant correlation between urinary 8-OHdG and UACR (r =?0.501, p 相似文献   

5.
A modified specific, sensitive and reproducible chiral gas chromatographic (GC) method for the resolution and quantification of ethosuximide enantiomers in urine and plasma was developed. The samples were extracted by liquid-liquid extraction, using diethylether and the enantiomers were separated and quantified on a chiral gas chromatographic column (25QC2 / CYDEX- beta 0.25). The method involved the use of GC/MS instrumentation for the acquisition of data in the electron impact selective-ion monitoring mode, collecting ions characteristic of both ethosuximide and alpha, alpha - dimethyl - beta - methylsuccinimide, the internal standard and of mass-to-charge ratio (m/z) exactly equal to 55 and 70 units. The limit of quantitation of the method was 2.5 microg/ml for both urine and plasma with both enantiomers. The method proved to be linear, precise and reproducible in the 5-300 microg/ml concentration range for urine samples and in the 10-250 microg/ml concentration range for plasma samples. Future research work envisaged the application of this method in pharmacokinetic and pharmacodynamic studies.  相似文献   

6.
An analytical method was developed and validated to determine Formoterol in human serum in the range from 0.40 to 100.24 pg/mL by high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) due to the lack of efficient methods to determine very low levels of Formoterol in serum and plasma. Serum was diluted by water and mixed with the internal standard (d6-Formoterol). Formoterol and internal standard were extracted using a cation-exchange solid phase column (SCX-3). After eliminating endogenous serum constituents through washing steps with water and methanol, elution took place using methanol/ammonia. After evaporation of the elution liquid the residue was redissolved and analyzed by HPLC-MS/MS with electrospray ionisation (ESI) in positive mode. A gradient between 10 mM ammonium formate and acetonitrile was used. The inter-batch precision of the calibration standards ranged from 1.55% to 9.01%. The inter-batch accuracy of the calibration standards ranged from 93.37% to 107.30%. The lower limit of quantitation (LLOQ, 0.40 pg/mL) had a precision of 19.67% and an accuracy of 96.78%. Comparable results were obtained for quality control samples. Stability in human serum was given over three freeze/thaw cycles and 2h at room temperature. Formoterol in human serum was stable for at least 6 months below -20 degrees C. This method has been used widely for quantifying Formoterol after inhalation of 9-36 microg of the drug by volunteers. A cross validation with human plasma versus serum was performed after this method was successfully validated in human serum.  相似文献   

7.
Urinary trans,trans-muconic acid (t,t-MA), a biomarker of benzene exposure, is usually determined by HPLC methods with detection by either UV or, more recently, electrospray tandem mass spectrometry. However, not all these methods have been fully validated for quantitative analysis. This paper presents an HPLC/MS/MS method for reliable quantitative determination of t,t-MA that uses a commercial deuterium-labeled isotope as internal standard; the matrix effect has been evaluated and LOD is 0.22 microg/L. We used this method to test 200 urine samples, 175 of them collected at end-of-shift from workers in an oil refinery.  相似文献   

8.
Previous studies have suggested that exposure to Ni from Ni-Cr alloys can affect the human body through oxidative stress. The present study discusses the effect of nickel from Ni-Cr alloy prostheses on the formation of DNA Adduct 8-Hydroxy-2′-Deoxyguanosine (8-OHdG), evaluated based on creatinine and 8-OHdG concentrations in urine, determined with LC-MS/MS, for a Ni-Cr alloy user group and a never-user control group. The mean creatinine and 8-OHdG concentrations were not significantly different between the test groups, although highest levels were observed for the in the Ni-Cr user group. It is suggested that samples with relatively high creatinine and/or 8-OHdG levels are further studied in more detail for stability of concentrations and for the effect of contributing factors.  相似文献   

9.
《Free radical research》2013,47(10):1291-1295
Abstract

Background. Measurement of urinary 8-hydroxy-2′-deoxyguanosine (8-OHdG) has recently become more popular as a means of assessing oxidative stress in the human body. The aim of this study is to compare the levels of urine 8-OHdG in patients with type 2 diabetes with and without nephropathy and to evaluate its role as a biochemical marker for distinguishing these patients from healthy and patients without complications. Methods. For this purpose, 52 patients with type 2 diabetes mellitus (32 with nephropathy (DMN), 20 without nephropathy (DM)) and 20 healthy control subjects (C) were included in this study. The urine concentrations of 8-OHdG were measured by modified LC-MS/MS method and compared with the first morning voiding urine albumin/creatinine ratio (UACR) and HbA1c values of the same patients. Results. The concentrations of urine 8-OHdG in DMN and DM patients were higher than those of the control subjects (3.47?±?0.94, 2.92?±?1.73, 2.1?±?0.93 nmol/mol creatinine, respectively). But there was no statistical difference between DMN and DM (p =?0.115). There is significant correlation between urinary 8-OHdG and UACR (r =?0.501, p <?0.001). According to ROC analysis, the AUC value of HbA1c was higher than the value of the AUC of 8-OHdG (0.882 and 0.771, respectively). Conclusions. This study shows that the urine 8-OHdG levels increase in diabetic patients. However, urinary 8-OHdG is not a useful clinical marker, compared with UACR, to predict the development of diabetic nephropathy in diabetic patients.  相似文献   

10.
A sensitive and simple liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the detection of alginate oligosaccharides (AOs) in mouse plasma and urine after oral administration. In an AO mixture, dimer, trimer, and tetramer were detected by LC-MS/MS equipped with an anion-exchange column with extremely high sensitivity. By this method, we detected certain levels of AOs in samples prepared from mouse plasma and urine after a single oral administration of the AO mixture. Based on a calibration curve made with an AO trimer peak area as a standard, the maximum plasma and urine concentrations of AOs were estimated to be 24.5 microg/ml at 5 min and 425.5 microg/ml at 30 min, respectively. These results suggest that the LC-MS/MS method is well suited to pharmacokinetic analysis of AOs in an in vivo system, and that some of orally administered AOs, at least from dimer to tetramer, are absorbed by digestive organs promptly, and that unaltered, these oligomers were excreted into an urine after a single oral administration to a mouse.  相似文献   

11.
A novel method for fast determination of fluoroacetamide, a kind of organic fluorine pesticide, in blood and urine samples was developed with acetamide as an internal standard using gas chromatography/mass spectrometry (GC/MS) after solid-phase microextraction (SPME) technique. The SPME was performed by immersing a PDMS fiber of 100 microm coating thickness in a sample solution for 25 min at 70 degrees C with (CH(3)CH(2))(4)NBr to improve the extraction efficiency. After a GC sample injection, the extracted fluoroacetamide was desorbed from the fiber for 4 min to perform the GC/MS detection with a HP-PLOT Q capillary column. The analytical conditions were optimized by examining systematically, the effects of experimental parameters on the ratio of characteristic ion peak areas of fluoroacetamide to acetamide. Under optimal conditions, the ratio was proportional to the concentration of fluoroacetamide ranging from 5.0 to 90 microg/ml with a detection limit of 1.0 microg/ml. The average recovery of fluoroacetamide in blood sample was 92.2%. The established method could be used for the fast and convenient measurement of fluoroacetamide in poisoned sample.  相似文献   

12.
Two sensitive and specific methods for quantification of biotin in feed, food, tablets, and premixes based on HPLC-MS/MS have been developed and validated. Depending on sample matrix and biotin content different extraction procedures and HPLC conditions were applied. Key steps in sample preparation were an alkaline extraction or a hydrolysis with sulphuric acid followed by enzymatic digest with papain. For many samples with low biotin content the latter combination of extraction steps was shown to be necessary for an optimal release of biotin from the matrix. The first time synthesis of deuterated biotin for use as internal standard allowed the compensation of losses during sample work-up and ion suppression during HPLC-MS/MS analysis. The new methods are faster than the commonly used microbiological assay using Lactobacillus plantarum. Additionally, they have a higher specificity as results for biotin are based on determination of a chemically defined compound, and not of a biological activity. Quantification is applicable to samples with a biotin content >100 microg/kg. Results obtained with the new methods have been compared with those of the microbiological assay, and were in good agreement.  相似文献   

13.
A rapid and sensitive method was developed using high-performance liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the quantification of besifloxacin in human tears using sparfloxacin as the internal standard (IS). Besifloxacin was extracted from human tear samples using an ammonium formate buffer at pH 3.25. The method was validated over a concentration range of 2-2000 ng/mL, with a total run time of less than 4 min. The overall intra- and inter-day precision for this method was less than 6%. The method was used to measure besifloxacin concentrations in tear samples collected after topical ocular administration to humans; besifloxacin concentrations were 610+/-540 microg/g (15 min) and 1.60+/-2.28 microg/g (24h).  相似文献   

14.
Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature (<18% deviation from theoretical) and during 3 freeze-thaw cycles (<1% deviation from theoretical, except at the lowest QC level). The LC/MS(3) assay was then used to successfully determine the concentration of 1,5-AG in more than 200 urine samples from diabetic patients enrolled in a clinical study.  相似文献   

15.
A quantitative method using HPLC-MS(2) has been developed for the determination of adonifoline, one of the retronecine-type hepatotoxic pyrrolizidine alkaloids in Senecio scandens Buch.-Ham. ex D. Don., a traditional Chinese herb. Using an orthogonal design test, a simple and rapid sample extraction method was developed. HPLC analysis was conducted using a C(18) column as stationary phase and a mixture of acetonitrile and aqueous formic acid as mobile phase. Good linearity for adonifoline was found in the concentration range 0.12-4.18 microg/mL, and the HPLC-MS/MS method was shown to be appropriate, in terms of sensitivity, precision and reproducibility. The quantities of adonifoline in extracts of 18 plant samples from different collection sources and from different parts (flowers, leaves, thick stems, slim stems and roots) of S. scandens were determined using the newly developed HPLC/MS(2) analysis.  相似文献   

16.
A rapid and accurate reversed-phase liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the quantitative determination of five flavonoid glycosides, icariin, epimedin A, epimedin B, epimedin C and hyperin in Herba Epimedii. Chromatographic separations were performed using a C(18) narrow-bore HPLC column; a mixture of an aqueous solution of ammonium formate (pH 4.0) and acetonitrile was used as the mobile phase, with compounds detected in the positive ion mode with multiple-reaction monitoring using a triple-quadrupole mass spectrometer equipped with an electrospray ionisation interface. This method for the determination of the reported flavonoid glycosides was accurate and reproducible, with a lower limit of quantication of 0.5 microg/mL. The standard calibration curves for the above-mentioned compounds were linear (r(2) > 0.998) over the concentration range 0.5-10.0 microg/mL. The relative standard deviations for intra- and inter-day precision over the concentration range for the flavonoid glycosides were lower than 7.8% with accuracy between 90.1 and 111.0%. The established method was successfully applied to the quality assessment of samples of Herba Epimedii collected from Korea and China.  相似文献   

17.
We developed a LC-MS/MS method for the quantitative determination of the mercapturic acid (MA) metabolites of acrylamide (AA) AAMA and of its oxidative metabolite glycidamide (GA) GAMA in urine samples from the general population. The method requires 4 mL of urine which is solid phase extracted prior to LC-MS/MS analysis. The metabolites are detected by ESI-tandem mass spectrometry in negative ionisation mode and quantified by isotope dilution. Detection limits ranged down to 1.5 microg/L urine for both AAMA and GAMA. The imprecision expressed as R.S.D. lay between 2% and 6% for both analytes (intra- and inter-assay). First results on a small group of 29 persons out of the general population ranged from 5 to 338 microg/L AAMA and 相似文献   

18.
Analytical method for the simultaneous determination of dextromethorphan (1) and dextrorphan (2) in urine, based on solid-phase extraction of drug from acidified hydrolyzed biological matrix, were developed. The analytes (1 and 2) and the internal standard (levallorphan, 3, IS) were detected by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) in positive ionization mode using a heated nebulizer (HN) probe and monitoring their precursor-->product ion combinations of m/z 272-->215, 258-->201, and 284-->201 for 1, 2, and 3, respectively, in multiple reaction monitoring mode. The analytes and IS were chromatographed on a Keystone Prism reverse phase (50 mm x 2.0 mm) 5 microm column using a mobile phases consisting of a 35/65 or 27/73 mixtures of methanol/water containing 0.1% TFA adjusted to pH 3 with ammonium hydroxide pumped at 0.4 ml/min for 1 and 2, respectively. The limits of reliable quantification of 1 and 2 were 2 and 250 ng/ml, respectively, when 1 ml of urine was processed. The absence of matrix effect was demonstrated by analysis of neat standards and standards spiked into urine extracts originating from five different sources. The linear ranges of the assay were 2-200 and 250-20,000 ng/ml for 1 and 2, respectively. Assay selectivity was evaluated by monitoring the "cross-talk" effects from other metabolites into the MS/MS channels used for monitoring 1, 2, and 3. In addition, an interfering peak originating from an unknown metabolite of 1 into the quantification of dextromethorphan was detected, requiring an effective chromatographic separation of analytes from other metabolites of 1. The need for careful assessment of selectivity of the HPLC-MS/MS assay in the presence of metabolites, and the assessment of matrix effect, are emphasized.  相似文献   

19.
A liquid chromatography/electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the first time for the determination of ibogaine and noribogaine in human plasma and whole blood. The method involved solid phase extraction of the compounds and the internal standard (fluorescein) from the two matrices using OasisHLB columns. LC separation was performed on a Zorbax eclipse XD8 C8 column (5 microm) with a mobile phase of acetonitrile containing 0.02% (v/v) trimethylamine and 2mM ammonium formate buffer. MS data were acquired in single ion monitoring mode at m/z 311.2, 297.2 and 332.5 for ibogaine, noribogaine and fluorescein, respectively. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (0.89-179 microg/l for ibogaine; 1-200 microg/l for noribogaine) and to whole blood concentrations (1.78-358 microg/kg for ibogaine; 2-400 microg/kg for noribogaine). Precision ranged from 4.5 to 13% and accuracy was 89-102%. Dilution of the samples had no influence on the performance of the method. Extraction recoveries were > or =94% in plasma and > or =57% in whole blood. The lower limits of quantitation were 0.89 microg/l for ibogaine and 1 microg/l for noribogaine in plasma, and 1.78 microg/kg for ibogaine and 2 microg/kg for noribogaine in whole blood. In frozen plasma samples, the two drugs were stable for at least 1 year. In blood, ibogaine and noribogaine were stable for 4h at 4 degrees C and 20 degrees C and 2 months at -20 degrees C. The method was successfully used for the analysis of a poisoning involving Tabernanthe iboga root.  相似文献   

20.
3-Nitrotyrosine (NO(2)Tyr) is a potential biomarker of reactive-nitrogen species (RNS) including peroxynitrite. 3-Nitrotyrosine occurs in human plasma in its free and protein-associated forms and is excreted in the urine. Measurement of 3-nitrotyrosine in human plasma is invasive and associated with numerous methodological problems. Recently, we have described an accurate method based on gas chromatography (GC)-tandem mass spectrometry (MS) for circulating 3-nitrotyrosine. The present article describes the extension of this method to urinary 3-nitrotyrosine. The method involves separation of urinary 3-nitrotyrosine from nitrite, nitrate and l-tyrosine by HPLC, preparation of the n-propyl-pentafluoropropionyltrimethylsilyl ether derivatives of endogenous 3-nitrotyrosine and the internal standard 3-nitro-l-[(2)H(3)]tyrosine, and GC-tandem MS quantification in the selected-reaction monitoring mode under negative-ion chemical ionization conditions. In urine of ten apparently healthy volunteers (years of age, 36.5+/-7.2) 3-nitrotyrosine levels were determined to be 8.4+/-10.4 nM (range, 1.6-33.2 nM) or 0.46+/-0.49 nmol/mmol creatinine (range, 0.05-1.30 nmol/mmol creatinine). The present GC-tandem MS method provides accurate values of 3-nitrotyrosine in human urine at the basal state. After oral intake of 3-nitro-l-tyrosine by a healthy volunteer (27.6 microg/kg body weight) 3-nitro-l-tyrosine appeared rapidly in the urine and was excreted following a biphasic pharmacokinetic profile. Approximately one third of administered 3-nitro-l-tyrosine was excreted within the first 8 h. The suitability of the non-invasive measurement of urinary 3-nitrotyrosine as a method of assessment of oxidative stress in humans remains to be established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号