首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper the development and feasibility of a novel detection system for a low molecular weight chemical, in which a peptide was utilized as a binding molecule, are described. Surface plasmon resonance (SPR) apparatus was used as a transducer. The porphyrin binding peptide, PSP2, was used as a model peptide ligand, while a porphyrin derivative, H2TMpyP, was used as a model low-molecular-weight chemical. PSP2 was covalently immobilized onto the SPR sensor chip and SPR measurement using the PSP2-immobilized chip for various concentrations of porphyrin was carried out. H2TMpyP was detectable in the range from 100 ng ml−1 to 10 μg ml−1 with a linear correlation and good precision and the PSP2-immobilized chip could be regenerated within 1 min after measurement in this system. From comparison of the detection manners of three porphyrin derivatives, the ability of a short peptide to discriminate between differences in molecular structure was demonstrated. Moreover, the self-assembled monolayer (SAM) of PSP2 was successfully prepared on the gold substrate and H2TMpyP could be detected using the PSP2-SAM chip.  相似文献   

2.
This paper presents a micro polymerase chain reaction (PCR) chip for the DNA-based diagnosis of microorganism genes and the detection of their corresponding antibiotic-resistant genes. The micro PCR chip comprises cheap biocompatible soda-lime glass substrates with integrated thin-film platinum resistors as heating/sensing elements, and is fabricated using micro-electro-mechanical-system (MEMS) techniques in a reliable batch-fabrication process. The heating and temperature sensing elements are made of the same material and are located inside the reaction chamber in order to ensure a uniform temperature distribution. This study performs the detection of several genes associated with upper respiratory tract infection microorganisms, i.e. Streptococcus pneumoniae, Haemopilus influenze, Staphylococcu aureus, Streptococcus pyogenes, and Neisseria meningitides, together with their corresponding antibiotic-resistant genes. The lower thermal inertia of the proposed micro PCR chip relative to conventional bench-top PCR systems enables a more rapid detection operation with reduced sample and reagent consumption. The experimental data reveal that the high heating and cooling rates of the system (20 and 10 degrees C/s, respectively) permit successful DNA amplification within 15 min. The micro PCR chip is also capable of performing multiple DNA amplification, i.e. the simultaneous duplication of multiple genes under different conditions in separate reaction wells. Compared with the large-scale PCR system, it is greatly advantageous for fast diagnosis of multiple infectious diseases. Multiplex PCR amplification of two DNA segments in the same well is also feasible using the proposed micro device. The developed micro PCR chip provides a crucial tool for genetic analysis, molecular biology, infectious disease detection, and many other biomedical applications.  相似文献   

3.
We have microfabricated a flow-through biochip for the analysis of single base mutations in genomic DNA using two different materials: (1) a polycarbonate (PC) chip for performing a primary polymerase chain reaction (PCR) followed by an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using a universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for sequential PCR/LDR in a continuous-flow format, in which the following three steps were carried out: (1) exponential amplification of gene fragments from genomic DNA; (2) mixing of the resultant PCR product with a LDR mixture via a Y-shaped passive micromixer and (3) ligation of two primers only when the particular mutation was present in the genomic DNA. A PMMA chip was employed as the microarray device, where zip code sequences (24-mer), which were complementary to sequences present on the discriminating primer, were micro-printed into fluidic channels embossed into the PMMA substrate. We successfully demonstrate the ability to detect one mutant DNA in 80 normal sequences with the integrated microfluidic device. The PCR/LDR/hybridization assay using the microchips performed the entire assay at a relatively fast processing speed: 18.7 min for PCR, 8.1 min for LDR, 5 min for hybridization, 10 min for washing and 2.6 min for fluorescence scanning (total processing time=ca. 50 min) with an order of magnitude reduction in reagents compared to bench-top formats.  相似文献   

4.

Background

Polymerase chain reaction (PCR) is used in nucleic acid tests of infectious diseases in point-of-care testing. Previous studies have demonstrated real-time PCR that uses a micro-PCR chip made of packing tape, double-sided tape, and a plastic cover with polycarbonate or polypropylene on a black matte printed circuit board substrate. Despite the success of DNA amplification and fluorescence detection using an early version of the micro-PCR chip, reaching the target temperature was fairly slow and, as a result, the total running time was getting longer. To reduce this runtime, the micro-PCR chip was modified by reducing the heater pattern size of the PCB substrate to one-quarter of the original size or less, while maintaining the ability of the heating pattern to cover the reservoir area of the microfluidic channel. In subsequent experiments, DNA amplification failed several times. During the analysis of the cause of this failure, it was found that the reagent was boiling with the heating range from 25 to 95 °C.

Methods

As a method of DNA amplification verification, images were captured by digital single-lens reflex camera to detect FAM fluorescence using diagonal illumination from a blue LED light source. The images were automatically captured at 72 °C (the extension step in nucleic acid amplification) and the brightness of the captured images was analyzed to con-firm the success of DNA amplification.

Results

Compared to the previous chip with a larger heating pattern size, the current chip appears to generate excess energy as the size of the heating pattern was reduced. To reduce this excess energy, the initial voltage was lowered to 2 V and 2.5 V, which is equivalent to a one-fifth and one-quarter voltage–power reduction in pulse width modulation control, respectively. In both voltage reduction cases, the DNA amplification was successful.

Conclusions

DNA amplification tests may fail due to the excess energy generated by reducing the heater pattern size of the PCB substrate. However, the tests succeeded when the voltage was reduced to 2 V or 2.5 V. The 2.5 V power test was more efficient for reducing the overall running time.
  相似文献   

5.
An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human -fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.  相似文献   

6.
Widely used nucleic acid assays are poorly suited for field deployment where access to laboratory instrumentation is limited or unavailable. The need for field deployable nucleic acid detection demands inexpensive, facile systems without sacrificing information capacity or sensitivity. Here we describe a novel microarray platform capable of rapid, sensitive nucleic acid detection without specialized instrumentation. The approach is based on a miniaturized lateral flow device that makes use of hybridization-mediated target capture. The miniaturization of lateral flow nucleic acid detection provides multiple advantages over traditional lateral flow devices. Ten-microliter sample volumes reduce reagent consumption and yield analyte detection times, excluding sample preparation and amplification, of <120s while providing sub-femtomole sensitivity. Moreover, the use of microarray technology increases the potential information capacity of lateral flow. Coupled with a hybridization-based detection scheme, the lateral flow microarray (LFM) enables sequence-specific detection, opening the door to highly multiplexed implementations for broad-range assays well suited for point-of-care and other field applications. The LFM system is demonstrated using an isothermal amplification strategy for detection of Bacillus anthracis, the etiologic agent of anthrax. RNA from as few as two B. anthracis cells was detected without thermocycling hardware or fluorescence detection systems.  相似文献   

7.
In this study, we describe a detection system for the indirect detection of vaccinia virus by DNA analysis. The system uses quartz crystal microbalance (QCM) as the detection technique and polymerase chain reaction (PCR) for amplification. Different immobilization strategies for the capture probe on the quartz chip are studied. For the QCM detection of hybridisation, the influence of the structure and length of target DNA is analyzed. For the detection of DNA from an amplification product, an efficient denaturation procedure is developed. On the basis of these investigations, vaccinia virus DNA is detected with only a low number of amplification rounds and a short analysis time. Specificity can be clearly shown. To enhance the signal strength and to have a further proof of specificity, a gold nanoparticle-tagged enhancer sequence can be used.  相似文献   

8.
AIMS: To develop a rapid, specific and sensitive diagnostic test for the detection of the spores of Bacillus anthracis on commercial samples of animal fibres (e.g. wool and cashmere). METHODS AND RESULTS: Extraction of DNA from spores using a mechanical disruption method based on bead beating was evaluated but subsequently abandoned as it compromised the sensitivity of the overall protocol. A multiplex PCR and two nested amplification reactions designed for B. anthracis were developed during this study. CONCLUSIONS: A simple selective incubation step in combination with multiplex PCR was found to be more effective than generic DNA extraction coupled to a sensitive nested amplification reaction. SIGNIFICANCE AND IMPACT OF THE STUDY: The rapid diagnostic test could be applied to the analysis of commercial fibre samples for the detection of anthrax as required by health and safety legislation resulting in considerable savings in time and expense.  相似文献   

9.
A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.  相似文献   

10.
目的采用分子检测技术对疑似隐球菌感染的脑膜炎病例进行诊断。方法收集患者的脑脊液样本,提取DNA,设计引物进行PCR扩增,采用DNA芯片技术对扩增产物进行分子检测。结果显示样本新生隐球菌阳性。结论通过ITS保守序列设计引物进行PCR扩增和DNA芯片技术对常规真菌学检查不能确定的疑似隐球菌脑膜炎患者脑脊液样本进行非培养检测,具有实验室诊断参考价值。  相似文献   

11.
Strizhkov BN  Drobyshev AL  Mikhailovich VM  Mirzabekov AD 《BioTechniques》2000,29(4):844-8, 850-2, 854 passim
PCR amplification on a microarray of gel-immobilized primers (microchip) has been developed. One of a pair of PCR primers was immobilized inside a separate microchip polyacrylamide porous gel pad of 0.1 x 0.1 x 0.02 (or 0.04) micron in size and 0.2 (or 0.4) nL in volume. The amplification was carried out simultaneously both in solution covering the microchip array and inside gel pads. Each gel pad contained the immobilized forward primers, while the fluorescently labeled reverse primers, as well as all components of the amplification reaction, diffused into the gel pads from the solution. To increase the amplification efficiency, the forward primers were also added into the solution. The kinetics of amplification was measured in real time in parallel for all gel pads with a fluorescent microscope equipped with a charge-coupled device (CCD) camera. The accuracy of the amplification was assessed by using the melting curves obtained for the duplexes formed by the labeled amplification product and the gel-immobilized primers during the amplification process; alternatively, the duplexes were produced by hybridization of the extended immobilized primers with labeled oligonucleotide probes. The on-chip amplification was applied to detect the anthrax toxin genes and the plasmid-borne beta-lactamase gene responsible for bacterial ampicillin resistance. The allele-specific type of PCR amplification was used to identify the Shiga toxin gene and discriminate it from the Shiga-like one. The genomic mutations responsible for rifampicin resistance of the Mycobacterium tuberculosis strains were detected by the same type of PCR amplification of the rpoB gene fragment isolated from sputum of tuberculosis patients. The on-chip PCR amplification has been shown to be a rapid, inexpensive and powerful tool to test genes responsible for bacterial toxin production and drug resistance, as well as to reveal point nucleotide mutations.  相似文献   

12.
目的比较四种方法检测乙型肝炎病毒基因型的差异性。方法对36例乙型肝炎患者的血清分别采用测序技术,荧光定量PCR技术,恒温扩增技术,基因芯片技术进行乙肝病毒基因型的检测。结果36份血清以测序技术为金标,观测荧光定量PCR技术特异性100%,敏感性83%,恒温扩增技术特异性100%,敏感性89%,基因芯片技术特异性100%,敏感度92%。结论目前临床采用的四种方法检测乙型肝炎病毒基因型的特异性相同,敏感度以测序为金标准,基因芯片技术最灵敏,其次为恒温扩增技术,最后为荧光定量PCR技术。  相似文献   

13.
Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for rapid identification of contaminants and quality control as well as high throughput screening of cells or microorganisms. A modular arrangement with five heating zones for flow-through PCR is discussed and evaluated. The special heater arrangement allows the implementation of up to 40 cycles on the footprint of a microscope slide, which is placed on top ofa 5 zones heating plate. Liquid/liquid two phase flow of PCR reaction mixture and mineral oil have been applied to create a segmented flow process scheme. In that way, the developed system may provide flow-through PCR as a unit operation for the droplet based microfluidics platform. The single use of disposable devices is commonly preferred due to the sensitivity of the PCR process to contaminations. All-glass microfluidic chips and disposable chip devices, made from polycarbonate as a replication with identically geometry, have been fabricated and tested. For the first time, microchannel geometries with nearly circular profile developed by all-glass technology have been transferred to mass fabrication by injection compression molding. Both devices have been successfully applied for the detection of the tumor suppressor gene p53. Although product yield and selectivity of the amplification process do not depend on the chip material, a well defined, reliable segmented flow regime could only be realized in the all-glass chip.  相似文献   

14.
为了建立一种基于芯片的快速鉴别羊肉掺假成分的方法,将不同动物源性成分的引物及反应所需试剂预先冻干固定到空白芯片反应池内,以制备羊肉掺假鉴别快速荧光定量PCR芯片。同时,通过模拟掺假样品(在羊肉中掺入猪肉、鸡肉、鸭肉、鼠肉成分)检测实验,对所得芯片的性能进行了评价。从与ABI7500荧光定量PCR结果对比可知,基于芯片的快速荧光定量PCR检测方法可以准确检测5种动物源性成分,具有较高的准确性及可用性,且其PCR扩增时间较短,操作简单,满足了羊肉掺假快速鉴别的要求。该芯片的研制及快速检测方法的建立将有效的简化羊肉制品掺假检测的步骤、缩短检测时间,且成本较低,仪器便于携带,使现场检测成为可能。研究结果为我国肉类食品安全监管提供了有力保障。  相似文献   

15.
A continuous flow polymerase chain reaction (CF-PCR) device comprises a single fluidic channel that is heated differentially to create spatial temperature variations such that a sample flowing through it experiences the thermal cycling required to induce amplification. This type of device can provide an effective means to detect the presence of a small amount of nucleic acid in very small sample volumes. CF-PCR is attractive for global health applications due to its less stringent requirements for temperature control than for other designs. For mass production of inexpensive CF-PCR devices, fabrication via thermoplastic molding will likely be necessary. Here we study the optimization of a PCR assay in a polymeric CF-PCR device. Three channel designs, with varying residence time ratios for the three PCR steps (denaturation, annealing, and extension), were modeled, built, and tested. A standardized assay was run on the three different chips, and the PCR yields were compared. The temperature gradient profiles of the three designs and the residence times of simulated DNA molecules flowing through each temperature zone were predicted using computational methods. PCR performance predicted by simulation corresponded to experimental results. The effects of DNA template size and cycle time on PCR yield were also studied. The experiments and simulations presented here guided the CF-PCR chip design and provide a model for predicting the performance of new CF-PCR designs prior to actual chip manufacture, resulting in faster turn around time for new device and assay design. Taken together, this framework of combined simulation and experimental development has greatly reduced assay development time for CF-PCR in our lab.  相似文献   

16.
Here we describe a new procedure (cloning of polymorphisms, COP) for enrichment of single nucleotide polymorphisms (SNPs) that represent restriction fragment length polymorphisms (RFLPs). COP would be applicable to the isolation of SNPs from particular regions of the genome, e.g. CpG islands, chromosomal bands, YACs or PAC contigs. A combination of digestion with restriction enzymes, treatment with uracil-DNA glycosylase and mung bean nuclease, PCR amplification and purification with streptavidin magnetic beads was used to isolate polymorphic sequences from the genomes of two human samples. After only two cycles of enrichment, 80% of the isolated clones were found to contain RFLPs. A simple method for the PCR detection of these polymorphisms was also developed.  相似文献   

17.
To establish the rapid detection method of airborne bacterial spores, we examined Bacillus anthracis spores by real-time PCR. One hundred liters of air were trapped on a filter of an air monitor device. After it was suspended in PBS, spores of B. anthracis were artificially added. The suspension was also heated at 95 degrees C for 15 min and used for real-time PCR using anthrax-specific primers. A single cell of B. anthracis was detected by real-time PCR within 1 h. Our results provide evidence that anthrax spores from the atmosphere can be detected rapidly, suggesting that real-time PCR provides a flexible and powerful tool to prevent epidemics.  相似文献   

18.
Biodevices composed of biomolecular layer have been developed in various fields such as medical diagnosis, pharmaceutical screening, electronic device, photonic device, environmental pollution detection device, and etc. The biomolecules such as protein, DNA and pigment, and cells have been used to construct the biodevices such as biomolecular diode, biostorage device, bioelectroluminescence device, protein chip, DNA chip, and cell chip. Substantial interest has focused upon thin film fabrication or the formation of biomaterials mono- or multi-layers on the solid surfaces to construct the biodevices. Based on the development of nanotechnology, nanoscale fabrication technology for biofilm has been emerged and applied to biodevices due to the various advantages such as high density immobilization and orientation control of immobilized biomolecules. This review described the nanoscale fabrication of biomolecular film and its application to bioelectronic devices and biochips.  相似文献   

19.
A bilirubin imprinted polymer (BIP) was coated on a thiol pretreated Au electrode on a quartz crystal microbalance (QCM) chip. The BIP thin film was synthesized using 4-vinylpyridine (4-Vpy) as the monomer, divinylbenzene (DVB) as the cross-linker, and benzophenone as the initiator. By using a photo-graft surface polymerization technique with irradiation by ultra-violet (UV) light, a thin BIP film was prepared, from which a biomimetic sensor for the detection of bilirubin was developed. The sensor was able to discriminate bilirubin in solution owing to the specific binding of the imprinted sites. The BIP/QCM chip has been repeatedly used for more than 7 months in many continuous experiments. The detection signal of bilirubin from the BIP thin film/QCM was compared with the non-BIP thin film/QCM. Biliverdin, an analogue of bilirubin, was used for comparison. The analogue comparison confirmed the binding specificity of the BIP film toward bilirubin. The selectivity can be as high as 31.2. The effect of pH on the detection of bilirubin is also discussed. With proper solvent for elution and recovery, flow injection analysis (FIA) could be applied to the system. The performance of the BIP/QCM chip was evaluated. A linear calibration of the bilirubin concentration with respect to the frequency shift was successfully obtained. The reproducibility of measurements from the same BIP/QCM chip was confirmed. In addition, repeatability of detection was also confirmed from different BIP/QCM chips. In conclusion, a combined BIP thin film/QCM/FIA method was successfully established for the detection of bilirubin concentration using a molecularly imprinted film.  相似文献   

20.
A thin film transistor (TFT) photosensor fabricated by semiconductor integrated circuit (IC) technology was applied to DNA chip technology. The surface of the TFT photosensor was coated with TiO2 using a vapor deposition technique for the fabrication of optical filters. The immobilization of thiolated oligonucleotide probes onto a TiO2-coated TFT photosensor using gamma-aminopropyltriethoxysilane (APTES) and N-(gamma-maleimidobutyloxy) sulfosuccinimide ester (GMBS) was optimized. The coverage value of immobilized oligonucleotides reached a plateau at 33.7 pmol/cm2, which was similar to a previous analysis using radioisotope-labeled oligonucleotides. The lowest detection limits were 0.05 pmol/cm2 for quantum dot and 2.1 pmol/cm2 for Alexa Fluor 350. Furthermore, single nucleotide polymorphism (SNP) detection was examined using the oligonucleotide-arrayed TFT photosensor. A SNP present in the aldehyde dehydrogenase 2 (ALDH2) gene was used as a target. The SNPs in ALDH2*1 and ALDH2*2 target DNA were detected successfully using the TFT photosensor. DNA hybridization in the presence of both ALDH2*1 and ALDH2*2 target DNA was observed using both ALDH2*1 and ALDH2*2 detection oligonucleotides-arrayed TFT photosensor. Use of the TFT photosensor will allow the development of a disposable photodetecting device for DNA chip systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏