首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for the determination of ulifloxacin, the active metabolite of prulifloxacin, in human plasma is described. After sample preparation by protein precipitation with methanol, ulifloxacin and ofloxacin (internal standard) were chromatographically separated on a C(18) column using a mobile phase consisting of methanol, water and formic acid (70:30:0.2, v/v/v) at a flow rate of 0.5 ml/min and then were detected using MS/MS by monitoring their precursor-to-product ion transitions, m/z 350-->m/z 248 for ulifloxacin and m/z 362-->m/z 261 for ofloxacin, in selected reaction monitoring (SRM) mode. Positive electrospray ionization was used for the ionization process. The linear range was 0.025-5.0 microg/ml for ulifloxacin with a lower limit of quantitation of 0.025 microg/ml. Within- and between-run precision was less than 6.6 and 7.8%, respectively, and accuracy was within 2.0%. The recovery ranged from 92.1 to 98.2% at the concentrations of 0.025, 0.50 and 5.0 microg/ml. Compared with the reported LC method, the present LC-MS/MS method can directly determine the ulifloxacin in human plasma without any need of derivatization. The present method has been successfully used for the pharmacokinetic studies of a prulifloxacin formulation product after oral administration to healthy volunteers.  相似文献   

2.
A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25–100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25–100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.  相似文献   

3.
A gas chromatographic method for the sensitive determination of midazolam in plasma volumes as low as 40 μl was developed, utilizing clinazolam as the internal standard. After liquid-liquid extraction at basic pH into 1-chlorobutane-dichloromethane (96:4) a 2- to 4-μl portion of the reconstituted extract was injected under electronic pressure control onto a 12 m × 0.2 mm I.D. methyl silicone capillary column, and was exposed to a three-step temperature program from 120 to 310°C, to separate the analytes from the plasma constituents. The compound of interest was identified and quantified by means of a mass-selective detector. The assay was linear from 10 to 500 ng/ml using 40 μl of plasma (limit of quantification: 10 ng/ml) and was linear from 0.25 to 100 ng/ml using 500 μl of plasma (limit of quantification: 0.25 ng/ml). The intra-day precision for the 40-μl aliquots varied from 2.2 to 6.6%, the corresponding accuracy from −7.4 to −4.4%; the inter-day precision ranged from 5 to 7.2% and the corresponding accuracy from −7.2 to −5.1%.  相似文献   

4.
A solid-phase extraction (SPE) procedure was developed for the quantification of nalbuphine in a small volume (500 μl) of human plasma with subsequent assay by high-performance liquid chromatography (HPLC) and electrochemical detection using 6-monoacetylmorphine as internal standard. Plasma was extracted using Bond Elute certified extraction columns (LCR: 10 ml, 130 mg) after conditioning with methanol and 0.2 M Tris buffer (pH 8). Elution was performed with a CH2Cl2-isopropanol-NH4OH (79:20:, v/v). The organic phase was evaporated to dryness and resuspended in HPLC mobile phase containing 2% isopropanol. Linearity was assessed over the 5–100 ng/ml concentration range and a straight line passing through the origin was obtained. Experiments with spiked plasma samples resulted in recoveries of 95±5.4% and 98±6.2% for nalbuphine and 6-monoacetylmorphine, respectively. The optimal pH conditions for the SPE were found at pH 8. The intra-day coefficients of variation (C.V.) for 5, 40, and 100 ng/ml were 5.3, 3.0 and 2.3% (n=8) and the inter-day C.V.s were 7.7, 3.2 and 3.5% (n=10), respectively. The detection limit for 500 μl plasma sample was 0.02 ng/ml and the limit of quantification 0.1 ng/ml (C.V.=12.4%). The ease of the proposed method of analysis, as well as its high accuracy and sensitivity allow its application to pharmacokinetic studies. A preliminary kinetic profile of nalbuphine after rectal administration in a pediatric patient is presented.  相似文献   

5.
Manumycin A is a natural antibiotic produced by Streptomyces parvulus that has antineoplastic activity against a variety of human cancers in nude mouse models. We have developed a highly sensitive reverse phase high-performance liquid chromatography (HPLC) method based on ultraviolet (UV) detection for the determination of manumycin A in mouse plasma. Manumycin A was isolated from mouse plasma by solid-phase extraction. A gradient elution of methanol and 0.05 M H(3)PO(4) with 0.2% triethylamine mobile phase was employed and separation was achieved with a C(18) analytical column. Manumycin A was detected by UV absorption at 345 nm. Retention time for manumycin A was 8.9+/-0.2 min. The manumycin A peak was baseline resolved, with the nearest peak at 1.5 min distance and no interfering peaks detected. Inter- and intra-day coefficients of variance were less than 6.1 and 5.1%, respectively. Based on an extracted manumycin A standard plasma sample of 0.25 microg/ml, the assay precision was 99.8% with a mean accuracy of 95.1%. At plasma concentrations of 0.5 and 5 microg/ml, the mean recovery rates of manumycin A were 59.64 and 60.28%, respectively. The lower limit of detection (LLD) for manumycin A was 0.1 microg/ml in mouse plasma. The lower limit of quantification (LLQ) for manumycin A was 0.125 microg/ml. Results of the stability study indicated that when frozen at -80 degrees C, manumycin A was stable in mouse plasma for up to 2 weeks. This method is useful in quantification of manumycin A in mouse plasma for clinical pharmacology studies in mice.  相似文献   

6.
A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.  相似文献   

7.
An analytical method was developed for the quantification of tezosentan in human plasma obtained in clinical studies. The method was linear in the range 1 to 512 ng/ml. After liquid-liquid extraction, the samples were analyzed by reversed-phase HPLC with tandem mass spectrometry. The limit of quantification was 1 ng/ml and the extraction recovery was at least 88.2%. Intra- and inter-assay coefficients of variation were below 10%. Stability tests revealed that tezosentan is stable under the different conditions tested.  相似文献   

8.
A selective and sensitive LC/MS/MS assay was developed for the quantification of d(2)-nicotine and d(2)-cotinine in plasma of current and past smokers administered d(2)-nicotine. After solid phase extraction and liquid-liquid extraction, HPLC separation was achieved on a capillary hydrophilic interaction chromatography phase column. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated for d(2)-nicotine (0.03-6.0 ng/ml plasma) and d(2)-cotinine (0.15-25 ng/ml plasma). The lower limits of quantitation were 0.15 ng/ml and 0.25 ng/ml for d(2)-nicotine and d(2)-cotinine, respectively. The coefficient of variation was 3.7% for d(2)-nicotine and 2.5% for d(2)-cotinine. The method was applied to two ongoing studies of d(2)-nicotine metabolism in prior and current smokers. Preliminary analysis of a subset of subjects from these studies detected a significantly lower rate of nicotine conversion to cotinine by past smokers compared to current smokers.  相似文献   

9.
A method for the determination of isosorbide-5-mononitrate (5-ISMN) in human plasma by capillary gas chromatography with electron-capture detection was developed and applied to clinical samples. 9-Fluorenone was used as an internal standard, ethyl acetate was employed for liquid-liquid extraction. The advantage of the extraction procedure is the possibility of a direct injection of the plasma extract, without solvent removal/reconstitution of the sample. The precision and accuracy of the method were satisfactory in the concentration range 10-1600 ng/ml. The lower limit of quantification was 10 ng/ml.  相似文献   

10.
Galantamine is an acetylcholinesterase inhibitor, recently approved for the treatment of mild-to-moderate Alzheimer's disease. To allow a higher throughput of samples, a new bioanalytical method for the determination of galantamine in human plasma was developed and validated. A stable isotope labelled internal standard was used. Sample preparation consisted of a simple one-step liquid-liquid extraction with toluene. The extracts were analysed with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS). The method was validated in the 1-500-ng/ml range. The accuracy, precision, selectivity, lower limit of quantification, upper limit of quantification, linearity and extraction recovery were evaluated, as well as the stability of the compound in plasma, blood, methanol and 2% BSA solutions under different conditions. The method proved very rugged during the analysis of large numbers of samples from clinical trials.  相似文献   

11.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

12.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

13.
A chiral capillary electrophoresis method has been developed for the quantification of 0.1% of the enantiomeric impurity (dextrocetirizine) in levocetirizine and determination of both in pharmaceuticals using sulfated-β-cyclodextrins (CDs) as chiral selector. Several parameters affecting the separation were studied such as the type and concentration of chiral selectors, buffer composition and pH, organic modifier, mixtures of two CDs in a dual system, voltage, and temperature. The optimal separation conditions were obtained using a 50 mM tetraborate buffer (pH 8.2) containing 1% (w/v) sulfated-β-CDs on a fused-silica capillary. Under these conditions, the resolution of two enantiomers was higher than 3. To validate the method, the stability of the solutions, robustness (two level half fraction factorial design for 5 factors using 19 experiments [2(n-1)+3]), precision, linearity (dextrocetirizine 0.25-2.5 μg/ml, R(2) = 0.9994, y = 0.0375x + 0.0008; levocetirizine 15-100 μg/ml, R(2) = 0.9996, y = 0.0213x + 0.0339), limit of detection (0.075 μg/ml, 0.03% m/m), limit of quantification (0.25 μg/ml, 0.1% m/m), accuracy (dextrocetirizine 84-109%, levocetirizine 97.3-103.1%), filter effect, and different CD batches were examined. The validated method was further applied to bulk drug and tablets of levocetirizine.  相似文献   

14.
A sensitive high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) assay was developed to determine raltitrexed in human plasma. After addition of benazeprilat as the internal standard (IS), methanol was used to produce a protein-free extract. Chromatographic separation was achieved with a Zorbax SB-C18 column (Narrow-Bore 2.1 mmx150 mm, 5-microm) using a mobile phase of acetonitrile-water containing 0.1% formic acid and 2% methanol (21.9:78.1, v/v). Raltitrexed was determined with electrospray ionization-mass spectrometry. HPLC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M+H]+ m/z 459.1 for raltitrexed and [M+H]+ m/z 397.1 for IS. Calibration curves were linear over the range of 2.0-3000 ng/ml. The lower limit of quantification was 2.0 ng/ml. The intra- and inter-batch variability values were less than 6.7% and 10.3%, respectively. The mean plasma extraction recovery of raltitrexed was in the range of 85.2-91.1%. The method was successfully applied to determine the plasma concentrations of raltitrexed in eight Chinese colorectal cancer patients.  相似文献   

15.
Solid-phase microextraction (SPME) was tested as a sample preparation for the simultaneous assay of ten antidepressant drugs and metabolites (TADs) in human plasma. Aqueous NaOH (0.5 ml, 1 M) and chloramitriptyline (50 μl, 40 μg/ml) as internal standard (I.S.) were added to a 2-ml plasma sample. This mixture was extracted with a 100-μm polydimethylsiloxane SPME fiber (Supelco) for 10 min. After washing in water and methanol (50%) and subsequent drying at room temperature, desorption of the fiber was performed in the injection port of a gas chromatograph at 260°C for 1 min (HP 5890, DB-17 30 m×0.25 mm I.D., 0.25 μm capillary; 0.7 ml/min nitrogen; nitrogen-phosphorus selective detection). The recovery was found to be very low from plasma (0.3% to 0.8%) but considerably higher from water (about 15%). Therefore, the high protein binding of antidepressants appears to be the main limiting mechanism for a better extraction. However, the analytes were well separated and the calibrations were linear between 125 ng/ml and 2000 ng/ml. The limits of quantification were about 90 ng/ml for imipramine and desipramine, 125 ng/ml for amitriptyline, trimipramine, doxepine, nortriptyline and mianserine and about 200 ng/ml for maprotiline, clomipramine and desmethylclomipramine. The recovery was improved by increasing the extraction time. The influence of the concentrations of the sum of proteins and of α-acid glycoprotein on the peak-area ratios ATAD/AI.S. and on absolute peak areas was studied. Peak-area ratios increased with decreasing protein concentration but were found to be independent on α-acid glycoprotein. A simple model for the explanation of the effect is presented. Measures for the improvement of sensitivity are discussed. As presented in this paper, which first describes SPME for the analysis of drugs in plasma, SPME with a short extraction time can be of only very limited value for therapeutic drug monitoring. Lower concentrations than the limit of quantification are usually found at therapeutic doses. The method can be useful for toxicological analysis after the accidental or suicidal intake of higher doses. However, an about 10-fold improvement of the sensitivity of the method seems to be possible.  相似文献   

16.
A rapid and feasible method was developed for the analysis of carbamazepine and its five metabolites (10,11-dihydro-10,11-epoxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine, 10,11-dihydro-10-hydroxycarbamazepine, 2-hydroxycarbamazepine and 3-hydroxycarbamazepine) in human plasma. Separation of the analytes is based on micellar electrokinetic chromatography, in untreated fused-silica capillary (48.5/40.0 cm length, 50 microm I.D.) with phosphate buffer (30 mM, pH 8.00) as background electrolyte, containing 50 mM sodium dodecylsulfate, and methanol (15%, v/v) as organic modifier. Clean up of human plasma samples was carried out by means of a solid-phase extraction procedure, which gave a high extraction yield for all six carbamazepines (>88%). The overall precision of the method gives a mean RSD of about 1.8%. The limit of quantitation for all analytes is < or = 0.30 microg ml(-1), the limit of detection < or = 0.12 microg ml(-1).  相似文献   

17.
A sensitive and specific method using liquid chromatography with electrospray ionization mass spectrometry (LC-ESI-MS) has been developed and validated for the identification and quantification of indapamide in human plasma. A simple liquid-liquid extraction procedure was followed by injection of the extracts on to a C18 column with gradient elution and detection using a single quadrupole mass spectrometer in selected ion monitoring (SIM) mode. The method was tested using six different plasma batches. Linearity was established for the concentration range 0.5-100.0 ng/ml, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (RSD%) was lower than 10%, and accuracy ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.2 ng/ml with 0.2 ml plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pre-clinical and clinical studies.  相似文献   

18.
A gas chromatographic—mass fragmentographic method using ammonia chemical ionization for the determination of dimethindene in human plasma is described. The drug was isolated from plasma by liquid—liquid extraction with hexane—2-methylbutanol. Plasma components were separated on a capillary column coated with chemically bonded methyl silicone. For detection of dimethindene, its quasi-molecular ion (M + H+) was mass fragmentographically monitored after chemical ionization with ammonia as reagent gas. Dimethindene was quantified using methaqualone as the internal standard: the quantification limit in plasma was 0.2 ng/ml, the within-run precision was 8.0% and the inter-run precision 5.6%. The plasma concentration—time profile was established after a single dose of 4 mg of dimethindene with an average maximum concentration of 5.5 ng/ml, detectable up to 48 h post application.  相似文献   

19.
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-day and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 microl plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 microl of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively.  相似文献   

20.
A method is described for the measurement of 5,5-diphenylbarbituric acid in plasma using high-performance liquid chromatography with UV detection. Briefly, the compounds are separated on a C18 reversed-phase column using a mobile phase of 50 mM sodium acetate (pH 4.5) and methanol. The flow-rate is 1.0 ml/min and 25 μl are injected and detected at 215 nm. The method is specific and sensitive in the range of concentrations tested, with a limit of quantification of 0.25 μg/ml. The calibration curves are linear for concentrations between 0.25 and 10 μg/ml. Intra-day and inter-day coefficients of variation are less than 8.5 and 10.5%, respectively, over the linear range. Intra-day and inter-day bias are less than 7.0 and 8.0%, respectively. A pharmacokinetic study conducted in male Beagle dogs administered 10 mg/kg of 1,3-dimethoxymethyl-5,5-diphenylbarbituric acid or 8 mg/kg of 5,5-diphenylbarbituric acid intravenously demonstrates the utility of this method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号