共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,675(1):180-182
A rapid high-performance liquid chromatography assay has been developed for the drug atovaquone, which is currently being used to treat Pneumocystis carinii pneumonia and Taxoplasma gondii encephalitis associated with the acquired immunodeficiency syndrome (AIDS). Protein is precipitated from plasma with acetonitrile-aqueous 1% acetic acid (85:15). The supernatant is assayed on a C6 column using methanol-10 mM triethylamine in aqueous 0.2% trifluoroacetic acid (76:24) with detection at 254 nm. The working assay range was 0.5 to 50 μg/ml. Recovery was 97% and the between-day coefficients of variation were 2.1% at 50 μg/ml and 10.3% at 1 μg/ml. A number of drugs commonly used to treat AIDS and its complications did not interfere with the assay. 相似文献
2.
3.
Nathalie Bleyzac Philippe Barou Gilles Aulagner 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,742(2):3255
A reversed-phase liquid chromatographic method with ultraviolet detection has been developed to determine busulfan concentrations in plasma of children undergoing bone marrow transplantation. Plasma samples (200 μl) containing busulfan and 1,6-bis(methanesulfonyloxy)hexane as an internal standard were prepared by a simple derivatization method with diethyldithiocarbamate followed by extraction with ethyl acetate and solid-phase purification on C8 columns conditioned with methanol and water and eluted with acetonitrile (recovery 99%). Chromatography was accomplished using a Hypersil octadecylsilyl column (10 cm×4.6 mm I.D.) and a mobile phase of acetonitrile, tetrahydrofuran and distilled water (65:5:30, v/v). The limit of detection was 25 ng/ml (signal-to-noise ratio of 5). Calibration curves were linear up to 25 000 ng/ml. Intra-day and inter-day coefficients of variation of the assay were ≤5%. This method was used to analyse busulfan plasma concentrations after oral administration within the framework of therapeutic drug monitoring and pharmacokinetic studies in children. 相似文献
4.
5.
6.
Diana S. -L. Chow Harshal P. Bhagwatwar Sasima Phadungpojna Borje S. Andersson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,704(1-2)
A sensitive, specific and stability-indicating high-performance liquid chromatographic (HPLC) assay, involving pre-column derivatization and solid-phase extraction (SPE), was developed and validated for the quantitation of busulfan (BU) in aqueous and plasma samples. The linearity of the assay was in the concentration ranges of 0.15–10 μg/ml and 0.15–3 μg/ml for aqueous and plasma samples, respectively. The within-day and between-day variations were 2.90 and 3.31%, respectively, for the aqueous samples, and 9.24 and 14.56%, respectively, for the plasma samples. The overall recovery, derivatization yield and SPE efficiency of BU from plasma samples were 82.03, 108.01 and 86.69%, respectively. Forced degraded samples, either in highly acidic, neutral or basic medium, produced no interfering peaks in the chromatogram. The reported assay requires only 0.2 ml of plasma for the analysis, and its sensitivity is 150 ng/ml by monitoring samples at a wavelength of 254 nm, sufficient to study the plasma pharmacokinetics of BU in rats after a clinically relevant oral dose. Moreover, the sensitivity of the assay can be significantly increased to 30 ng/ml by monitoring samples at a wavelength of 278 nm. The applications of the assay were demonstrated with BU solubility measurements in two aqueous systems and with plasma samples from a Sprague–Dawley rat for an in vivo pharmacokinetic study. In addition, the assay has been employed in the development of a patented intravenous formulation, and in evaluations of stability, preclinical pharmacokinetics in rats and dogs, and clinical phase I trial of the formulation. The assay is readily adaptable to clinical therapeutic drug monitoring. 相似文献
7.
Stereospecific high-performance liquid chromatographic assay of ketoprofen in human plasma and urine
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,668(1):175-181
A high-performance liquid chromatographic (HPLC) assay suitable for the analysis of the enantiomers of ketoprofen (KT), a 2-arylpropionic acid (2-APA) non-steroidal antiinflammatory drug (NSAID), in plasma and urine was developed. Following the addition of racemic fenoprofen as internal standard (I.S.), plasma containing the KT enantiomers and I.S. was extracted by liquid-liquid extraction at an acidic pH. After evaporation of the organic layer, the drug and I.S. were reconstituted in mobile phase and injeted into the HPLC system. The enantiomers were separated at ambient temperature on a commercially available 250 × 4.3 mm amylose carbamate-packed chiral column (Chiralpak AD) column with hexane-isopropyl alcohol-trifluoroacetic acid (80:19.9:0.1, v/v/v) as the mobile phase pumped at 1.0 ml/min. The enantiomers of KT were quantified by ultraviolet detection with the wavelength set at 254 nm. The assay described allows for the direct quantification of KT enantiomers without pre-column derivatization, and is suitable for clinical studies of KT enantiomers in human plasma and urine after administration of therapeutic doses. 相似文献
8.
M. Masood Bhatti Robert T. Foster 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,579(2)
A valid, sensitive high-performance liquid chromatographic technique is reported for the separation of the two enantiomers of metoprolol in human plasma. The procedure involves pre-column derivatization with the homochiral reagent S-(+)-1-(1-naphthyl)-ethyl isocyanate. Once formed, the diastereomers are separated using normal-phase high-performance liquid chromatography. Fluorescence detection (220 nm excitation; no emission filter) was utilized, resulting in baseline resolution (Rs > 1.5). The peaks corresponding to metoprolol enantiomers were free from interference throughout the examined range of 5–500 ng/ml; accuracy and precision were within approximately 10%. Analysis of a plasma sample collected from a healthy volunteer demonstrated that the assay is applicable to clinical studies. 相似文献
9.
Robert A. Parise Dale R. Miles Merrill J. Egorin 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,749(2)
We present new HPLC methods for the quantitation in human plasma of two investigative metallotexaphyrin agents, motexafin gadolinium (Gd-Tex) and motexafin lutetium (Lu-Tex). Each assay uses: the other texaphyrin analogue as an internal standard; protein precipitation with acetonitrile:methanol (50:50, v/v); an ODS reversed-phase column; an isocratic mobile phase of 100 mM ammonium acetate, pH 4.3:acetonitrile:methanol (59:21:20, v/v/v); and absorbance detection at 470 nm. The Gd-Tex assay has a lower limit of quantitation (LLOQ) of 0.01 μM and is linear between 0.01and 30 μM. The Lu-Tex assay has an LLOQ of 0.1 μM and is linear between 0.1 and 30 μM. The assays are suited for in vivo preclinical studies and clinical trials because they require minimal amounts of plasma, are sensitive, and involve a 30-min run time. These assays are important tools for evaluating the potential of Gd-Tex and Lu-Tex as a radiation enhancer and photosensitizer, respectively. 相似文献
10.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,754(1):121-126
A column-switching high-performance liquid chromatography (HPLC) method for the determination of aloesin in rat plasma using column-switching and ultraviolet (UV) absorbance detection is described. Plasma was directly injected onto the HPLC system consisting of a clean-up column, a concentrating column, and an analytical column, which were connected with a six-port switching valve. The determination of aloesin was accurate and repeatable, with a limit of quantitation of 10 ng/ml in plasma. The standard calibration curve for aloesin was linear (r=0.998) over the concentration range of 10–1000 ng/ml in rat plasma. The intra- and inter-day assay variabilities of aloesin ranged from 1.0 to 4.7% and 1.1 to 8.8%, respectively. This highly sensitive and simple method has been successfully applied to a pharmacokinetic study after oral administration of aloesin to rats. 相似文献
11.
Phillip A. Reece Irene Cozamanis Rudolf Zacest 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1981,225(1):151-160
Endralazine (I) is a new antihypertensive which is chemically and pharmacologically related to hydralazine and dihydralazine. A sensitive high-performance liquid chromatographic-fluorescence assay for the drug and two of its metabolites [methyltriazoloendralazine (VII) and hydroxymethyltriazoloendralazine (VIII)] in human plasma was developed. After conversion of I and its internal standard to triazolopyridopyridazine derivatives the latter and metabolites were separated by high-performance liquid chromatography and detected using their fluorescence. The limits of detection of the assay were 1 nmol/l for I and VII and 0.1 nmol/l for VIII. Intra-assay coefficients of variation were 2.5–5.1% for I (range 1000–10 nmol/l), 4.2–4.5% for VII (range 100–5 nmol/l) and 3.4–5.7% for VIII (range 100–1 nmol/l). Following oral administration of 5 and 10 mg of I to two normal volunteers (slow acetylators) peak plasma levels of I occurred between 0.75 and 1 h after the dose, and declined in a biexponential fashion. The terminal half-life ranged from 2.8–3.7 h. These results contrast with those obtained for hydralazine in plasma where in vitro and in vivo half-lives were 30 min. 相似文献
12.
Robbin B. Burns Leanne Embree 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,744(2)
Validation of two HPLC assays for the quantitation of carboplatin in human plasma ultrafiltrate is described. Both assay methods employed a YMC ODS-AQ 3.9×150 mm (3 μm) column for the chromatographic separation. The first method utilized direct UV detection, the second method utilized UV detection following post-column derivatization with sodium bisulfite. Structural analogues of carboplatin were synthesized and used as internal standards for the assays. With direct UV detection, sample clean-up using solid-phase extraction on amino cartridges was required prior to injection, with extraction recoveries ranging from 80 to 90%. This extraction procedure was not necessary with the post-column reaction method, which employed a more selective analytical wavelength. Unfortunately, instability of the post-column reagent was a problem and led to greater variability in predicted concentration values. For standard curves, a weighted (1/y2) regression approach was used for plots of peak area or peak height ratio (carboplatin/internal standard) vs. carboplatin concentration. The limit of detection of both assays was 0.025 μg/ml and both were validated for carboplatin concentrations from 0.05 to 40 μg/ml. Accuracy and precision data were generated using three batches of validation samples, each batch consisting of a standard curve and five sets of quality control samples. Stability of carboplatin in blood, plasma, plasma ultrafiltrate, and reconstituted extracts was evaluated. The assay methods were employed for the pharmacokinetic analysis of blood samples drawn from a pediatric patient that received a 400 mg/m2 dose of carboplatin. 相似文献
13.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1991,566(2):327-332
High-performance liquid chromatography (HPLC) is a powerful technique which enables a reliable and quantitative determination of enzyme activities. The purpose of the work reported here was to develop an automatic assay of enzymatic activity. Using an automatic sample processor and injector, a program was developed which allows the complete automation of each step of analysis (calibration, enzymatic reaction, HPLC determination). This program can be adapted to different experimental requirements as each step can be performed independently and each input (time, volume, number of standards) is made by answering questions asked by instrument. Using this approach both kinetic and single-point determinations can be carried out, and in the latter case different samples can be analysed sequentially. This paper reports the automated analysis of trypsin. 相似文献
14.
S. Laganire E. Kwong D. D. Shen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1989,488(2)
A simple and sensitive stereoselective high-performance liquid chromatographic assay for the quantitation of propranolol enantiomers in serum is described. The method involves conversion of the propranolol enantiomers to diastereomeric urea derivatives by reaction with the chiral reagent (+)-phenylethylisocyanate, followed by chromatographic separation of the diastereomeric products. Conditions of the derivatization reaction were optimized to achieve rapid and quantitative yield with either of the enantiomers. Baseline resolution of the diastereomers was achieved on a reversed phase C8 column with an isocratic mobile phase. Fluorescence detection afforded an absolute on-column detection limit of 100 pg. The assay has been applied to pharmacokinetic studies in humans and small laboratory animals. 相似文献
15.
Mohammed S. Hussain Vern Chukwumaeze-Obiajunwa Ronald G. Micetich 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,663(2)
A rapid, sensitive and reproducible reversed-phase high-performance liquid chromatographic assay was developed for the determination of norfloxacin. Following protein precipitation with 10% trichloroacetic acid, norfloxacin and the internal standard enoxacin were extracted from plasma with chloroform, dried and reconstituted in the mobile phase. The chromatographic separation of norfloxacin and the internal standard enoxacin was achieved on a C8 column with fluorescence detection set at 280 and 418 nm for excitation and emission, respectively. The peaks with a resolution factor greater than 1.5 were free from interferences. Excellent linearity (r2 0.998) was observed over the concentration range 0.025–5.0 μg/ml in plasma. The inter-assay variability was 13.6% or less at all concentrations examined. The suitability of the assay for pharmacokinetic studies was determined by measuring norfloxacin concentration in rat plasma after administration of a single intravenous 10 mg/kg dose. 相似文献
16.
Zhang M Moore GA Gardiner SJ Begg EJ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,830(2):245-248
A rapid and simple HPLC assay was developed for the determination of celecoxib in human plasma and breast milk. After proteins were precipitated with acetonitrile, celecoxib was resolved on a C18 column and detected by UV detection at 254 nm. Standard curves were linear over the concentration range 10-2000 microg/L (r(2)>0.99). Bias was =+/-15% from 20 to 2000 microg/L in both matrices, intra- and inter-day coefficients of variation (imprecision) were <10%, and the limit of quantification was 10 microg/L. 相似文献
17.
Alan R. Brown Charles D. James Richard M. Welch Jane Croft Harrelson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,578(2)
A high-performance liquid chromatographic assay with fluorometric detection was developed for the analysis of the stereoisomers of mivacurium, a new short-acting neuromuscular blocker, in plasma. The isomers were isolated from plasma by solid-phase extraction with C18 and anion-exchange cartridges. The extracts were chromatographed on a LiChrosphere 60 RP Select B column (125 mm × 4.6 mm I.D.) using a mobile phase of acetonitrile—water (4:6, v/v) containing 0.005 M octanesulfonic acid. The fluorescence excitation and emission wavelengths were 202 and 320 nm, respectively. The accuracy and precision of the assay, expressed as the percentage deviation of measured values from true values and the percentage coefficient of variation, respectively, were ≤ 10% at all concentrations except for the percentage coefficient of variation at the lower limit of quantitation (5 ng/ml). The assay has been successfully used for the analysis of plasma samples from a pharmacokinetic study in human volunteers. 相似文献
18.
Koks CH Sparidans RW Lucassen G Crommentuyn KM Beijnen JH 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,767(1):103-110
A sensitive and selective reversed-phase liquid chromatographic assay for itraconazole and hydroxyitraconazole in human plasma has been developed and validated. Itraconazole and hydroxyitraconazole were extracted from the matrix using solid-phase extraction on a strong cation-exchange sorbent. All compounds were detected using fluorescence at 265 and 363 nm for excitation and emission, respectively. The assay has been validated over the range 10-1,000 ng/ml for both compounds, 10 ng/ml being the lower limit of quantification. Accuracies ranged from 104 to 113% for itraconazole and from 91 to 103% for hydroxyitraconazole. The intra-assay precisions were all below 9% for itraconazole and below 8% for hydroxyitraconazole. The selectivity has been evaluated with respect to all registered anti-human immunodeficiency virus (HIV) drugs and other potential co-medications and a few of their metabolites, commonly used by HIV-infected individuals. Both itraconazole and hydroxyitraconazole were stable under relevant conditions for HIV-inactivation and storage of samples. The applicability of the assay was demonstrated for samples collected from a treated HIV-infected patient. 相似文献
19.
Zhang M Moore GA Gardiner SJ Begg EJ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,807(2):217-221
A rapid and simple HPLC assay was developed for the determination of rofecoxib in human plasma and breast milk. After solid-phase extraction, rofecoxib was resolved on a C18 column and detected by UV detection at 272 nm. Standard curves were linear over the concentration range 10-2000 microg/L (r2 >0.99). Intra- and inter-day coefficients of variation for both matrices were <10% and the limit of quantification was around 10 microg/L. 相似文献
20.
Yu Yamaguchi Masaru Kunitomo Jun Haginaka 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,716(1-2)
A fast, accurate and precise high-performance liquid chromatographic assay method has been developed for plasma lipoproteins of experimental animals, rabbits, rats and mice. The method includes complete separation of high, low and very low density lipoproteins from one another within 20 min by a DEAE–glucomannan gel using stepwise elution, and determination by postcolumn reaction with an enzymatic cholesterol reagent as the total cholesterol level. The relative standard deviation of each lipoprotein assay was highly reproducible, being less than 2.0 and 2.4% for repeatability and intermediate precision, respectively. The method was successfully applied to the assays of plasma lipoproteins in three species of normolipidemic and hyperlipidemic animals. 相似文献