首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
基质辅助激光解吸电离飞行时间质谱技术(MALDI-TOF-MS)目前是一种快速而可靠的微生物鉴定方法.随着可鉴定真菌谱的完善,MALDI-TOF MS技术已逐步应用于临床常见致病酵母菌、酵母样真菌和丝状菌的鉴定中,本文将就此做一综述.  相似文献   

2.

Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) is widely used in clinical laboratories for routine identification of bacteria and yeasts. However, methodological difficulties are still apparent when applied to filamentous fungi. The liquid cultivation method recommended by Bruker Daltonics GmbH for identification of filamentous fungi by MALDI-TOF MS is labour intensive and time-consuming. In this study, growth of Aspergillus species on different (porous) surfaces was investigated with the aim to develop a more reliable, quicker and less laborious identification method using MALDI-TOF MS. Mycelial growth without sporulation mimicking liquid cultivation and reliable MALDI-TOF MS spectra were obtained when A. fumigatus strains were grown on and in between a polycarbonate membrane filter on Sabouraud dextrose agar. A database of in-house reference spectra was created by growing Aspergillus reference strains (mainly focusing on sections Fumigati and Flavi) under these selected conditions. A test set of 50 molecularly identified strains grown under different conditions was used to select the best growth condition for identification and to perform an initial validation of the in-house database. Based on these results, the cultivation method on top of a polycarbonate filter proved to be most successful for species identification. This method was therefore selected for the identification of two sets of clinical isolates that mainly consisted of Aspergilli (100 strains originating from Indonesia, 70 isolates from Qatar). The results showed that this cultivation method is reliable for identification of clinically relevant Aspergillus species, with 67% and 76% correct identification of strains from Indonesia and Qatar, respectively. In conclusion, cultivation of Aspergilli on top of a polycarbonate filter showed improved results compared to the liquid cultivation protocol recommended by Bruker in terms of percentage of correct identification, ease of MSP creation, time consumption, cost and labour intensity. This method can be reliably applied for identification of clinically important Aspergilli and has potential for identification of other filamentous fungi.

  相似文献   

3.
Until recently, microbial identification in clinical diagnostic laboratories has mainly relied on conventional phenotypic and gene sequencing identification techniques. The development of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) devices has revolutionized the routine identification of microorganisms in clinical microbiology laboratories by introducing an easy, rapid, high throughput, low-cost, and efficient identification technique. This technology has been adapted to the constraint of clinical diagnostic laboratories and has the potential to replace and/or complement conventional identification techniques for both bacterial and fungal strains. Using standardized procedures, the resolution of MALDI-TOF MS allows accurate identification at the species level of most Gram-positive and Gram-negative bacterial strains with the exception of a few difficult strains that require more attention and further development of the method. Similarly, the routine identification by MALDI-TOF MS of yeast isolates is reliable and much quicker than conventional techniques. Recent studies have shown that MALDI-TOF MS has also the potential to accurately identify filamentous fungi and dermatophytes, providing that specific standardized procedures are established for these microorganisms. Moreover, MALDI-TOF MS has been used successfully for microbial typing and identification at the subspecies level, demonstrating that this technology is a potential efficient tool for epidemiological studies and for taxonomical classification.  相似文献   

4.
MALDI-TOF MS is a recent technique, which revolutionized bacterial species identifications, due to its simplicity, accuracy and speed of analysis. The same efficiency of species identification for fungi is highly sought. This review aims to discuss the evolving role of MALDI-TOF MS in the laboratory diagnosis of fungal infections. Yeast identifications are increasingly being performed with MALDI-TOF MS in a routine setting with good results. A further extension of the libraries will further increase its potential. Direct identification of yeast in blood cultures and MALDI-TOF MS susceptibility testing are new promising applications. The identification of filamentous fungi on MALDI-TOF MS is still challenging, but knowledge and experience is taking huge leaps forward.  相似文献   

5.
We assessed the accuracy of species-level identification of two commercially available matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems (Bruker Biotyper and Vitek MS) and two conventional phenotypic methods (Phoenix 100 YBC and Vitek 2 Yeast ID) with that of rDNA gene sequencing analysis among 200 clinical isolates of commonly encountered yeasts. The correct identification rates of the 200 yeast isolates to species or complex (Candida parapsilosis complex, C. guilliermondii complex and C. rugosa complex) levels by the Bruker Biotyper, Vitek MS (using in vitro devices [IVD] database), Phoenix 100 YBC and Vitek 2 Yeast ID (Sabouraud''s dextrose agar) systems were 92.5%, 79.5%, 89%, and 74%, respectively. An additional 72 isolates of C. parapsilosis complex and 18 from the above 200 isolates (30 in each of C. parapsilosis, C. metapsilosis, and C. orthopsilosis) were also evaluated separately. Bruker Biotyper system could accurately identify all C. parapsilosis complex to species level. Using Vitek 2 MS (IVD) system, all C. parapsilosis but none of C. metapsilosis, or C. orthopsilosis could be accurately identified. Among the 89 yeasts misidentified by the Vitek 2 MS (IVD) system, 39 (43.8%), including 27 C. orthopsilosis isolates, could be correctly identified Using the Vitek MS Plus SARAMIS database for research use only. This resulted in an increase in the rate of correct identification of all yeast isolates (87.5%) by Vitek 2 MS. The two species in C. guilliermondii complex (C. guilliermondii and C. fermentati) isolates were correctly identified by cluster analysis of spectra generated by the Bruker Biotyper system. Based on the results obtained in the current study, MALDI-TOF MS systems present a promising alternative for the routine identification of yeast species, including clinically commonly and rarely encountered yeast species and several species belonging to C. parapsilosis complex, C. guilliermondii complex, and C. rugosa complex.  相似文献   

6.
In recent years, MALDI-TOF Mass Spectrometry (MS) method has emerged as a promising and a reliable tool for bacteria identification. In this study we compared Bruker MALDI-TOF MS and conventional phenotypic methods to identify a collection of 333 Gram-positive clinical isolates comprising 22 genera and 60 species. 16S rRNA sequencing was the reference molecular technique, and rpoB gene sequecing was used as a secondary gene target when 16Sr RNA did not allow species identification of Corynebacterium spp. We also investigate if score cut-offs values of ≥1,5 and ≥1,7 were accurate for genus and species-level identification using the Bruker system. Identification at species level was obtained for 92,49% of Gram-positive rods by MALDI-TOF MS compared to 85,89% by phenotypic method. Our data validates the score ≥1,5 for genus level and ≥1,7 for species-level identification in a large and diverse collection of Gram-positive rods. The present study has proved the accuracy of MALDI-TOF MS as an identification method in Gram-positive rods compared to currently used methods in routine laboratories.  相似文献   

7.
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid, highly accurate, and cost-effective method for routine identification of a wide range of microorganisms. We carried out a side by side comparative evaluation of the performance of Bruker Biotyper versus VITEK MS for identification of a large and diverse collection of microorganisms. Most difficult and/or unusual microorganisms, as well as commonly encountered microorganisms were selected, including Gram-positive and negative bacteria, mycobacteria, actinomycetes, yeasts and filamentous fungi. Six hundred forty two strains representing 159 genera and 441 species from clinical specimens previously identified at the Laboratoire de santé publique du Québec (LSPQ) by reference methods were retrospectively chosen for the study. They included 254 Gram-positive bacteria, 167 Gram-negative bacteria, 109 mycobacteria and aerobic actinomycetes and 112 yeasts and moulds. MALDI-TOF MS analyses were performed on both systems according to the manufacturer’s instructions. Of the 642 strains tested, the name of the genus and / or species of 572 strains were referenced in the Bruker database while 406 were present in the VITEK MS IVD database. The Biotyper correctly identified 494 (86.4%) of the strains, while the VITEK MS correctly identified 362 (92.3%) of the strains (excluding 14 mycobacteria that were not tested). Of the 70 strains not present in the Bruker database at the species level, the Biotyper correctly identified 10 (14.3%) to the genus level and 2 (2.9%) to the complex/group level. For 52 (74.2%) strains, we obtained no identification, and an incorrect identification was given for 6 (8.6%) strains. Of the 178 strains not present in the VITEK MS IVD database at the species level (excluding 71 untested mycobacteria and actinomycetes), the VITEK MS correctly identified 12 (6.8%) of the strains each to the genus and to the complex/group level. For 97 (54.5%) strains, no identification was given and for 69 (38.7%) strains, an incorrect identification was obtained. Our study demonstrates that both systems gave a high level (above 85%) of correct identification for a wide range of microorganisms. However, VITEK MS gave more misidentification when the microorganism analysed was not present in the database, compared to Bruker Biotyper. This should be taken into account when this technology is used alone for microorganism identification in a public health laboratory, where isolates received are often difficult to identify and/or unusual microorganisms.  相似文献   

8.

Purpose of Review

The diagnosis of invasive fungal disease remains challenging in the clinical laboratory. In this paper, the use of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) for the identification of filamentous fungi as well as its application for antifungal resistance testing and strain typing is evaluated.

Recent Findings

Most studies report very high accuracy for the identification of filamentous fungi by MALDI-TOF MS. Its cost effectiveness, short analysis time, and low error rate and the fact that it can also discriminate between closely related and cryptic species make it appropriate for implementation in the clinical routine. Two drawbacks remain in the availability of extended reference spectra databases and the fact that this technique can only be applied on isolates.

Summary

More work on (simultaneous) antifungal susceptibility testing and strain typing is needed. The application of MALDI-TOF MS directly on clinical specimens would further improve the diagnosis of invasive fungal disease and improve its successful management.
  相似文献   

9.
Identification of filamentous fungi, molds and dermatophytes, is currently based on the morphological study of colonies and therefore the experience of the mycologist. These techniques are not sufficiently precise to distinguish between different species within the same section. Furthermore, identification can be delayed for several weeks due to subcultures on specific media. MALDI-TOF MS allows correct identification of filamentous fungi until the species level in more than 95% of cases in most studies. MALDI-TOF MS is a fast and precise identification technique for filamentous fungi; however most of the different databases need to be further evaluated in routine and completed to broaden the spectrum of species identified.  相似文献   

10.
MALDI-TOF MS has become increasingly popular for microorganism identification in the routine laboratory. Compared with conventional morphology-based techniques, MALDI-TOF is relatively inexpensive (per-unit identification), involves a rapid result turnaround time and yields more accurate results without the need for highly qualified staff. However, this technology has been technically difficult to implement for filamentous fungi identification. Identification of dermatophytes, a type of filamentous fungi, remains particularly challenging, partly due to the lack of clear species definition for some taxa or within some species complexes. Review of the ten studies published between 2008 and 2015 shows that the accuracy of MALDI-TOF MS-based identification varied between 13.5 and 100 % for dermatophytes. This variability was partly due to inconsistencies concerning critical steps of the routine clinical laboratory process. Use of both a complete formic acid-acetonitrile protein extraction step and a manufacturer library supplemented with homemade reference spectra is essential for an accurate species identification. This technique is conversely unaffected by variations in other routine clinical laboratory conditions such as culture medium type, incubation time and type of mass spectrometry instrument. Provided that a reference spectra library is adequate for dermatophyte identification, MALDI-TOF MS identification is more economical and offers an accuracy comparable to that of DNA sequencing. The technique also represents an advantageous alternative to the protracted and labor-intensive dermatophyte identification via macroscopic and microscopic morphology in the routine clinical laboratory.  相似文献   

11.
ITS序列分析与MALDI-TOF MS质谱技术在丝状真菌鉴定中的应用   总被引:2,自引:0,他引:2  
丝状真菌常用的鉴定方法为形态方法和基因鉴定方法,前者限于检验人员的知识和技能,后者操作繁琐,费用略昂贵,不适合常规开展。因此,寻找丝状真菌快速鉴定方法势在必行。本文采用VITEK MALDI-TOF MS(基质辅助激光解析电离时间飞行质谱)IVD数据库(3.0版本)对临床分离的254株丝状真菌进行鉴定,并以ITS(internal transcribed spacer 内转录间隔区)序列分析为标准,验证MALDI-TOF MS质谱技术鉴定丝状真菌的准确性。结果表明MALDI-TOF MS质谱技术可以对大部分丝状真菌实现快速、准确的鉴定,其中对毛癣菌属(100%)、毛孢子菌属(100%)、毛霉菌属(100%)、曲霉菌属(96.5%)准确率很高,对犬小孢子菌(75%)、镰刀菌属(50%)、新月弯孢霉(46.2%)准确率较低,对丝状真菌鉴定的总体准确率为86.36%,与ITS测序分析符合率为83.97%。  相似文献   

12.

Background

Multilocus PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS) is a new strategy for pathogen identification, but information about its application in fungal identification remains sparse.

Methods

One-hundred and twelve strains and isolates of clinically important fungi and Prototheca species were subjected to both rRNA gene sequencing and PCR/ESI-MS. Three regions of the rRNA gene were used as targets for sequencing: the 5′ end of the large subunit rRNA gene (D1/D2 region), and the internal transcribed spacers 1 and 2 (ITS1 and ITS2 regions). Microbial identification (Micro ID), acquired by combining results of phenotypic methods and rRNA gene sequencing, was used to evaluate the results of PCR/ESI-MS.

Results

For identification of yeasts and filamentous fungi, combined sequencing of the three regions had the best performance (species-level identification rate of 93.8% and 81.8% respectively). The highest species-level identification rate was achieved by sequencing of D1/D2 for yeasts (92.2%) and ITS2 for filamentous fungi (75.8%). The two Prototheca species could be identified to species level by D1/D2 sequencing but not by ITS1 or ITS2. For the 102 strains and isolates within the coverage of PCR/ESI-MS identification, 87.3% (89/102) achieved species-level identification, 100% (89/89) of which were concordant to Micro ID on species/complex level. The species-level identification rates for yeasts and filamentous fungi were 93.9% (62/66) and 75% (27/36) respectively.

Conclusions

rRNA gene sequencing provides accurate identification information, with the best results obtained by a combination of ITS1, ITS2 and D1/D2 sequencing. Our preliminary data indicated that PCR/ESI-MS method also provides a rapid and accurate identification for many clinical relevant fungi.  相似文献   

13.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has emerged as a reliable tool for fast identification and classification of microorganisms. In this regard, it represents a strong challenge to microscopic and molecular biology methods. Nowadays, commercial MALDI systems are accessible for biological research work as well as for diagnostic applications in clinical medicine, biotechnology and industry. They are employed namely in bacterial biotyping but numerous experimental strategies have also been developed for the analysis of fungi, which is the topic of the present review. Members of many fungal genera such as Aspergillus, Fusarium, Penicillium or Trichoderma and also various yeasts from clinical samples (e.g. Candida albicans) have been successfully identified by MALDI-TOF MS. However, there is no versatile method for fungi currently available even though the use of only a limited number of matrix compounds has been reported. Either intact cell/spore MALDI-TOF MS is chosen or an extraction of surface proteins is performed and then the resulting extract is measured. Biotrophic fungal phytopathogens can be identified via a direct acquisition of MALDI-TOF mass spectra e.g. from infected plant organs contaminated by fungal spores. Mass spectrometric peptide/protein profiles of fungi display peaks in the m/z region of 1000–20 000, where a unique set of biomarker ions may appear facilitating a differentiation of samples at the level of genus, species or strain. This is done with the help of a processing software and spectral database of reference strains, which should preferably be constructed under the same standardized experimental conditions.  相似文献   

14.
The prompt and accurate identification of bacterial pathogens is fundamental to patient health and outcome. Recent advances in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) have revolutionized bacterial identification in the clinical laboratory, but uniform incorporation of this technology in the U.S. market has been delayed by a lack of FDA-cleared systems. In this study, we conducted a multicenter evaluation of the MALDI Biotyper CA (MBT-CA) System (Bruker Daltonics Inc, Billerica, MA) for the identification of aerobic gram-negative bacteria as part of a 510(k) submission to the FDA. A total of 2,263 aerobic gram negative bacterial isolates were tested representing 23 genera and 61 species. Isolates were collected from various clinical sources and results obtained from the MBT-CA System were compared to DNA sequencing and/or biochemical testing. Isolates that failed to report as a "high confidence species ID" [log(score) ≥2.00] were re-tested using an extraction method. The MBT-CA System identified 96.8% and 3.1% of isolates with either a "high confidence" or a "low confidence" [log(score) value between 1.70 and <2.00] species ID, respectively. Two isolates did not produce acceptable confidence scores after extraction. The MBT-CA System correctly identified 99.8% (2,258/2,263) to genus and 98.2% (2,222/2,263) to species level. These data demonstrate that the MBT-CA System provides accurate results for the identification of aerobic gram-negative bacteria.  相似文献   

15.
邵锦  万喆  李若瑜  余进 《菌物学报》2019,38(8):1277-1286
基质辅助激光解析电离飞行时间质谱(matrix-assisted laser desorption/ionization time-of-flight mass spectrometry,MALDI-TOF MS)是近年来新兴的微生物检测技术,通过核糖体蛋白分析实现对真菌快速、准确鉴定。本文针对MALDI-TOF MS用于致病真菌鉴定、分类、体外抗真菌药物敏感性检测以及临床微生物样本直接检测等方面作一综述。  相似文献   

16.
The increasing diversity of opportunistic fungi causing serious invasive fungal infections (IFI) has been documented. Accurate identification (ID) is important in guiding therapy, determining prognosis for IFIs and in epidemiological surveys. We assessed the utility of PCR-based methods for the ID of yeasts and moulds that either were uncommon, failed conventional ID, or represented unusual biochemical or phenotypic profiles of common species. Among 1,790 viable fungal clinical isolates received during the SENTRY Program in 2010, 322 strains from 40 study sites had ID confirmed by molecular methods. Isolates were previously identified in participant institutions. Yeasts that were not confirmed by morphology on CHROMagar, growth at 45?°C (Candida albicans/dubliniensis), or assimilation of trehalose (C. glabrata) as well as non-Candida yeasts and all moulds were amplified and sequenced using primers amplifying one or more of the following genes: ITS, 28S, β-tubulin (Aspergillus spp.), TEF (Fusarium spp.), IGS (Trichosporon spp.). The isolates selected for molecular ID included 149 isolates of Candida species, 77 of Aspergillus species, 73 non-Candida yeasts, and 23 other moulds (a total of 41 different species). Overall, the ID determined by the submitting site was confirmed for 189 isolates (58.7?%): Aspergillus spp. (64.1?% correct); Candida spp. (60.1?% correct); non-Candida yeasts (58.9?% correct); non-Aspergillus moulds (30.4?% correct). Species with high levels of concordance between conventional and molecular ID included A. fumigatus (95.0 %), C. lusitaniae (100?%), C. dubliniensis (92.3?%), C. kefyr (100?%), and C. neoformans (90.2?%). Only 50.0?% of isolates of C. albicans and 59.1?% of C. glabrata selected due to unusual phenotypic or biochemical features were found to be correctly identified by the submitting site. Molecular methods for the identification of fungal pathogens are an important adjunct to the conventional identification of many less common clinically relevant yeasts and moulds including species of Candida with unusual or erroneous phenotypic or biochemical profiles. Molecular confirmation of fungal identification is essential in epidemiological surveys such as SENTRY.  相似文献   

17.
Species of the family Pasteurellaceae play an important role as primary or opportunistic animal pathogens. In veterinary diagnostic laboratories identification of this group of bacteria is mainly done by phenotypic assays while genetic identification based on housekeeping genes is mostly used for research and particularly important diagnostic samples. MALDI-TOF MS seems to represent a promising alternative to the currently practiced cumbersome, phenotypic diagnostics carried out in many veterinary diagnostic laboratories. We therefore assessed its application for animal associated members of the family Pasteurellaceae. The Bruker Biotyper 3.0 database was complemented with reference spectra of clinically relevant as well as commensal animal Pasteurellaceae species using generally five strains per species or subspecies and tested for its diagnostic potential with additional, well characterized field isolates. About 250 strains comprising 15 genera and more than 40 species and subspecies were included in the study, covering most representatives of the family. A high discrimination at the genus and species level was observed. Problematic discrimination was only observed with some closely related species and subspecies. MALDI-TOF MS was shown to represent a highly potent method for the diagnosis of this group of animal pathogens, combining speed, precision and low running costs.  相似文献   

18.
MALDI-TOF mass spectrometry (MS) is becoming essential in most clinical microbiology laboratories throughout the world. Its successful use is mainly attributable to the low operational costs, the universality and flexibility of detection, as well as the specificity and speed of analysis. Based on characteristic protein spectra obtained from intact cells – by means of simple, rapid and reproducible preanalytical and analytical protocols – MALDI-TOF MS allows a highly discriminatory identification of yeasts and filamentous fungi starting from colonies. Whenever used early, direct identification of yeasts from positive blood cultures has the potential to greatly shorten turnaround times and to improve laboratory diagnosis of fungemia. More recently, but still at an infancy stage, MALDI-TOF MS is used to perform strain typing and to determine antifungal drug susceptibility. In this article, the authors discuss how the MALDI-TOF MS technology is destined to become a powerful tool for routine mycological diagnostics.  相似文献   

19.
目的探讨MALDI-TOF MS对肺炎链球菌鉴定和质谱分型的应用价值。方法收集2009年1月至2013年5月温州医科大学附属第二医院临床分离的112株肺炎链球菌标本,采用Optochin敏感试验和全自动细菌分析仪对收集的菌株进行鉴定验证,并用Microflex MALDI-TOF质谱仪进行分析鉴定。根据质谱图的相似性进行细菌同源聚类树分析并构建质谱分型模型,采用荚膜肿胀试验对参与分型的菌株进行血清型比较。结果除20株不符合检测条件之外,92株临床菌株和1株标准株经质谱分析均为肺炎链球菌,选取的60株菌株以0.5的差异水平,将60株肺炎链球菌分为18个质谱型别,在这些菌株的血清分型中有19F、19A、23F、23A、3和14六个血清型别,分布于不同的MALDI-TOF MS分型中,其中19F有18株,占30%(18/60),分布在6种不同的MALDI-TOF MS分型中,也有3型血清型较为集中地分布于相应的MALDI-TOF MS一个型别里。结论 MALDI-TOF MS能快速、准确、简便地鉴定肺炎链球菌,且能达到种的水平。对比血清型,按照0.5差异水平,建立的18个质谱分型部分的型别与血清型有一致性,但也存有差异。  相似文献   

20.
目的评价直接使用基质辅助激光解析电离飞行时间质谱(MALDI-TOF MS)联合Sepsityper Kit试剂盒法(简称试剂盒法)、SELTERS法和血清分离胶法(简称分离胶法)鉴定阳性血培养瓶血中细菌的符合率,并对SELTERS方法进行改进,以缩短样本处理时间。方法对656例临床血培养阳性标本,应用试剂盒法、SELTERS方法或分离胶法处理后,直接使用质谱仪快速鉴定菌株,同时进行传统培养,比较分析二者之间的差异。结果656例血培养阳性标本共分离出626株单种菌感染和30株多种菌感染标本。MALDI-TOF MS联合试剂盒法、SELTERS法或分离胶法可在1 h内快速鉴定血培养阳性标本。在单种细菌感染中,MALDI-TOF MS联合试剂盒法直接鉴定革兰阳性菌的种、属符合率分别是66.8%(141/211)、21.3%(45/211),革兰阴性菌的种、属符合率分别是97.1%(367/378)、0.8%(3/378),真菌的种、属符合率分别是32.4%(12/37)、0.0%(0/37);MALDI-TOF MS联合SELTERS法直接鉴定革兰阳性菌的种、属符合率分别是66.8%(141/211)、21.3%(45/211),革兰阴性菌的种、属符合率分别是96.3%(364/378)、2.4%(9/378),真菌的种、属符合率分别是32.4%(12/37)、2.7%(1/37);MALDI-TOF MS联合分离胶法直接鉴定革兰阳性菌的种、属符合率分别是51.2%(108/211)、20.9%(44/211),革兰阴性菌的种、属符合率分别是93.4%(353/378)、1.6%(6/378),真菌的种、属符合率分别是13.5%(5/37)、2.7%(1/37);MALDI-TOF MS联合改良SELTERS法直接鉴定革兰阳性菌的种、属符合率分别是59.1%(13/22)、18.2%(4/22),革兰阴性菌的种、属符合率分别是88.5%(23/26)、3.8%(1/26),真菌的种、属符合率分别是0.0%(0/2)、50.0%(1/2)。而对于多种菌感染的血培养瓶,3种方法鉴定率均较低。结论MALDI-TOF MS联合试剂盒法、SELTERS法或分离胶直接鉴定阳性血标本中的病原菌,其结果可在1 h内获得,并与传统培养结果相比具有较高的符合率。但是这些方法检测更快速、操作更简便,同时改良SELTERS法样本处理时间缩短,成本降低,且符合率与前3种方法没有区别。这4种方法均能满足临床快速诊断和及时有效抗菌治疗的需求,临床可根据自身情况选择。  相似文献   