首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The capability of a two‐stage electrochemical treatment for the regeneration of acidic heavy‐metal containing process water was examined. The process water came from sediment bioleaching and was characterized by a wide spectrum of dissolved metals, a high sulfate content, and a pH of about 3. In the modular laboratory model cell used, the anode chamber and the cathode chamber were separated by a central chamber fitted with an ion exchanger membrane on either side. The experiments were carried out applying a platinum anode and a graphite cathode at a current density of 0.1 A/cm2. The circulation flow of the process water in the batch process amounted to 35 L/h, the electrolysis duration was 5.5 h at maximum and the total electrolysis current was about 1 A. In the first stage, the acidic process water containing metals passed through the cathode chamber. In the second stage, the cathodically pretreated process water was electrolyzed anodically. In the cathode chamber the main load of dissolved Cu, Zn, Cr and Pb was eliminated. The sulfuric acid surplus of 3–4 g/L decreased to about 1 g/L, the pH rose from initially 3.0 to 4–5, but the desired pH of 9–10 was not achieved. Precipitation in the proximity to the cathode evidently takes place at a higher pH than farther away. The dominant process in the anode chamber was the precipitation of amorphous MnO2 owing to the oxidation of dissolved Mn(II). The further depletion of the remaining heavy metals in the cathodically pretreated process water by subsequent anodic treatment was nearly exhaustive, more than 99 % of Cd, Cr, Cu, Mn, Ni, Pb, and Zn were removed from the leachate. The high depletion of heavy metals might be due to both the sorption on MnO2 precipitates and/or basic ferrous sulfate formed anodically, and the migration of metal ions through the cation exchanger membrane via the middle chamber into the cathode chamber. In the anode chamber, the sulfuric acid content increased to 6–7 g/L and the pH sank to 1.7. All heavy metals contained, with the exception of Zn, were removed to levels below the German limits for discharging industrial wastewaters into the receiving water. Moreover, the metal‐depleted and acid‐enriched process waters could be returned to the leaching process, hence reducing the output of wastewater. The results indicated that heavy metals could be removed from acidic process waters by two‐stage electrochemical treatment to a large extent. However, to improve the efficiency of metal removal and to establish the electrochemical treatment in practice, further work is necessary to optimize the operation of the process with respect to current density, energy consumption, discharging of metal precipitates deposited in the electrode chambers and preventing membrane clogging.  相似文献   

2.
Microbial fuel cells (MFCs) can be built with layered electrode assemblies, where the anode, proton exchange membrane (PEM), and cathode are pressed into a single unit. We studied the performance and microbial community structure of MFCs with layered assemblies, addressing the effect of materials and oxygen crossover on the community structure. Four MFCs with layered assemblies were constructed using Nafion or Ultrex PEMs and a plain carbon cloth electrode or a cathode with an oxygen-resistant polytetrafluoroethylene diffusion layer. The MFC with Nafion PEM and cathode diffusion layer achieved the highest power density, 381 mW/m2 (20 W/m3). The rates of oxygen diffusion from cathode to anode were three times higher in the MFCs with plain cathodes compared to those with diffusion-layer cathodes. Microsensor studies revealed little accumulation of oxygen within the anode cloth. However, the abundance of bacteria known to use oxygen as an electron acceptor, but not known to have exoelectrogenic activity, was greater in MFCs with plain cathodes. The MFCs with diffusion-layer cathodes had high abundance of exoelectrogenic bacteria within the genus Geobacter. This work suggests that cathode materials can significantly influence oxygen crossover and the relative abundance of exoelectrogenic bacteria on the anode, while PEM materials have little influence on anode community structure. Our results show that oxygen crossover can significantly decrease the performance of air-cathode MFCs with layered assemblies, and therefore limiting crossover may be of particular importance for these types of MFCs.  相似文献   

3.
The application of a rotating cathode in a river sediment microbial fuel cell increased the oxygen availability to the cathode, and therefore improved the cathode reaction rate, resulting in a higher power production (49 mW/m2) compared to a nonrotating cathode system (29 mW/m2). The increased dissolved oxygen in the water of our lab-scale sediment MFC, however, resulted in a less negative anode potential and a higher anodic charge transfer resistance, which constrained the maximum power density. Thus, an optimum balance between the superior cathode reaction rates and the inferior anode reaction rates due to higher dissolved oxygen levels must be ascertained.  相似文献   

4.
Enzymatic biofuel cell based on enzyme modified anode and cathode electrodes are both powered by ethanol and operate at ambient temperature is described. The anode of the presented biofuel cell was based on immobilized quino-hemoprotein-alcohol dehydrogenase (QH-ADH), while the cathode on co-immobilized alcohol oxidase (AOx) and microperoxidase (MP-8). Two enzymes AOx and MP-8 acted in the consecutive mode and were applied in the design of the biofuel cell cathode. The ability of QH-ADH to transfer electrons directly towards the carbon-based electrode and the ability of MP-8 to accept electrons directly from the same type of electrodes was exploited in this biofuel cell design. Direct electron transfer (DET) to/from enzymes was the basis for generating an electric potential between the anode and cathode. Application of immobilized enzymes and the harvesting of the same type of fuel at both electrodes (cathode and anode) avoided the compartmentization of enzymatic biofuel cell. The maximal open circuit potential of the biofuel cell was 240mV.  相似文献   

5.
Mohan SV  Srikanth S 《Bioresource technology》2011,102(22):10210-10220
Microbially catalyzed treatment of wastewater was evaluated in both the anode and cathode chambers in dual chambered microbial fuel cell (MFC) under varying biocathode microenvironment. MFC operation with aerobic biocathode showed significant increment in both TDS (cathode, 90.2±1%; anode, 39.7±0.5%) and substrate (cathode, 98.07±0.06%; anode, 96.2±0.3%) removal compared to anaerobic biocathode and abiotic cathode operations (COD, 80.25±0.3%; TDS, 30.5±1.2%). Microbially catalyzed reduction of protons and electrons at cathode will be higher during aerobic biocathode operation which leads to gradual substrate removal resulting in stable bio-potential for longer periods facilitating salts removal. Bio-electro catalytic behavior showed higher exchange current density during aerobic biocathode operation resulting in induced electrochemical oxidation which supports the enhanced treatment. Anaerobic biocathode operation depicted relatively less TDS removal (anode, 16.35%; cathode, 16.04%) in both the chambers in spite of good substrate degradation (anode, 84%; cathode, 87.39%). Both the chambers during anaerobic biocathode operation competed as electron donors resulting in negligible bio-potential development.  相似文献   

6.
This study investigates the influence of anode and cathode size and arrangement on hydrogen production in a membrane-less flat-plate microbial electrolysis cell (MEC). Protein measurements were used to evaluate microbial density in the carbon felt anode. The protein concentration was observed to significantly decrease with the increase in distance from the anode-cathode interface. Cathode placement on both sides of the carbon felt anode was found to increase the current, but also led to increased losses of hydrogen to hydrogenotrophic activity leading to methane production. Overall, the best performance was obtained in the flat-plate MEC with a two-layer 10 mm thick carbon felt anode and a single gas-diffusion cathode sandwiched between the anode and the hydrogen collection compartments.  相似文献   

7.
8.
Pathologic tilt of subjective visual vertical (SVV) frequently has adverse functional consequences for patients with stroke and vestibular disorders. Repetitive transcranial magnetic stimulation (rTMS) of the supramarginal gyrus can produce a transitory tilt on SVV in healthy subjects. However, the effect of transcranial direct current stimulation (tDCS) on SVV has never been systematically studied. We investigated whether bilateral tDCS over the temporal-parietal region could result in both online and offline SVV misperception in healthy subjects. In a randomized, sham-controlled, single-blind crossover pilot study, thirteen healthy subjects performed tests of SVV before, during and after the tDCS applied over the temporal-parietal region in three conditions used on different days: right anode/left cathode; right cathode/left anode; and sham. Subjects were blind to the tDCS conditions. Montage-specific current flow patterns were investigated using computational models. SVV was significantly displaced towards the anode during both active stimulation conditions when compared to sham condition. Immediately after both active conditions, there were rebound effects. Longer lasting after-effects towards the anode occurred only in the right cathode/left anode condition. Current flow models predicted the stimulation of temporal-parietal regions under the electrodes and deep clusters in the posterior limb of the internal capsule. The present findings indicate that tDCS over the temporal-parietal region can significantly alter human SVV perception. This tDCS approach may be a potential clinical tool for the treatment of SVV misperception in neurological patients.  相似文献   

9.
For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.  相似文献   

10.
Electrochemical impedance spectroscopy (EIS) was used to study the behavior of a microbial fuel cell (MFC) during initial biofilm growth in an acetate-fed, two-chamber MFC system with ferricyanide in the cathode. EIS experiments were performed both on the full cell (between cathode and anode) as well as on individual electrodes. The Nyquist plots of the EIS data were fitted with an equivalent electrical circuit to estimate the contributions of various intrinsic resistances to the overall internal MFC impedance. During initial development of the anode biofilm, the anode polarization resistance was found to decrease by over 70% at open circuit and by over 45% at 27 microA/cm(2), and a simultaneous increase in power density by about 120% was observed. The exchange current density for the bio-electrochemical reaction on the anode was estimated to be in the range of 40-60 nA/cm(2) for an immature biofilm after 5 days of closed circuit operation, which increased to around 182 nA/cm(2) after more than 3 weeks of operation and stable performance in an identical parallel system. The polarization resistance of the anode was 30-40 times higher than that of the ferricyanide cathode for the conditions tested, even with an established biofilm. For a two-chamber MFC system with a Nafion 117 membrane and an inter-electrode spacing of 15 cm, the membrane and electrolyte solution dominate the ohmic resistance and contribute to over 95% of the MFC internal impedance. Detailed EIS analyses provide new insights into the dominant kinetic resistance of the anode bio-electrochemical reaction and its influence on the overall power output of the MFC system, even in the high internal resistance system used in this study. These results suggest that new strategies to address this kinetic constraint of the anode bio-electrochemical reactions are needed to complement the reduction of ohmic resistance in modern designs.  相似文献   

11.
The elimination of heavy metals from bioleaching process waters (leachates) by electrolysis was studied in the anode and cathode region of a membrane electrolysis cell at current densities of 5–20 mA/cm2 using various electrode materials. The leaching waters containing a wide range of dissolved heavy metals, were high in sulfate, and had pH values of approx. 3. In preliminary tests using a rotating disc electrode the current density‐potential curve (CPK) was recorded at a rotation velocity of 0, 1000 and 2000 rpm and a scan rate of 10 mV/s in order to collect information on the influence of transport processes on the electrochemical processes taking place at the electrodes. The electrochemical deposition‐dissolution processes at the cathode are strongly dependent on the hydrodynamics. Detailed examination of the anodic oxidation of dissolved Mn(II) indicated that the manganese dioxide which formed adhered well to the electrode surface but in the cathodic return run it was again reduced. Electrode pairs of high‐grade steel, lead and coal as well as material combinations were used to investigate heavy metal elimination in a membrane electrolysis cell. Using high‐grade steel, lead and carbon electrode pairs, the reduction and deposition of Cu, Zn, Cr, Ni and some Cd in metallic or hydroxide form were observed in an order of 10–40 % in the cathode chamber. The dominant process in the anode chamber was the precipitation of manganese dioxide owing to the oxidation of dissolved Mn(II). Large amounts of heavy metals were co‐precipitated by adsorption onto the insoluble MnO2. High‐grade steel and to some extent lead anodes were dissolved and hence were proven unsuitable as an anode material. These findings were largely confirmed by experiments using combination electrodes of coal and platinized titanium as an anode material and steel as a cathode material. With both electrode combinations and current densities of 5 or 10 mA/cm2, in the cathode region low depositions of 10–20 % Cd, 2–10% Mn, 5–20 % Zn, 1–20 % Co and 5–15 % Ni were measured. By contrast, the elimination of other metals was substantially larger: Fe 40 –60 %, Cu 20–40 %, and Cr 40–60 %. In the anode region the removal of heavy metals was in the order of 30–50%, with Mn being as high as 80 %. The anode materials exhibit good resistance at the current densities tested. The precipitates deposited in both electrode regions contained as main components Al with 10–20 %, Mg with approximately 10 %, and SO4 with 5–20 %. The solid material in the cathode chamber consisted of relatively high proportions of Zn and Mn. Calcium in the solids indicated the co‐precipitation of calcium sulfate. The main components in the solids of the anode chamber were Mn in the form of pyrolusite, Al as basic sulfate, and Mg. The results indicate that electrochemical metal separation in the membrane electrolysis cell can represent a practical alternative to the metal separation by alkalization. Regarding the main heavy metals Zn, Mn and Ni in the process water, combination electrodes using steel as a cathode material and coal or platinized titanium as an anode material proved to be suitable for eliminating the heavy metals from the aqueous phase. However, for practical application, further work is necessary to improve the efficiency, applicability and costs of the process.  相似文献   

12.
A compact, three‐in‐one, flow‐through, porous, electrode design with minimal electrode spacing and minimal dead volume was implemented to develop a microbial fuel cell (MFC) with improved anode performance. A biofilm‐dominated anode consortium enriched under a multimode, continuous‐flow regime was used. The increase in the power density of the MFC was investigated by changing the cathode (type, as well as catholyte strength) to determine whether anode was limiting. The power density obtained with an air‐breathing cathode was 56 W/m3 of net anode volume (590 mW/m2) and 203 W/m3 (2160 mW/m2) with a 50‐mM ferricyanide‐based cathode. Increasing the ferricyanide concentration and ionic strength further increased the power density, reaching 304 W/m3 (3220 mW/m2, with 200 mM ferricyanide and 200 mM buffer concentration). The increasing trend in the power density indicated that the anode was not limiting and that higher power densities could be obtained using cathodes capable of higher rates of oxidation. The internal solution resistance for the MFC was 5–6 Ω, which supported the improved performance of the anode design. A new parameter defined as the ratio of projected surface area to total anode volume is suggested as a design parameter to relate volumetric and area‐based power densities and to enable comparison of various MFC configurations. Published 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

13.
Results are presented from experimental studies of a high-current electric discharge operating between an St45 steel cathode and a service water anode in a wide range of air pressures. Peculiarities of discharge ignition and specific features of cathode and anode spots were revealed. The behavior of the current density on a service water anode was investigated for the first time. Comparison of the current densities j on the steel cathode and service water anode shows that, in the parameter range under study, Hehl’s law is not satisfied on the water anode. The two-dimensional distribution of the potential inside and on the surface of the service water anode was measured.  相似文献   

14.
Mechanisms of tumor electrochemical treatment (ECT) were studied using normal dog liver. Five physical and chemical methods were used. Two platinum electrodes were inserted into an anesthetized dog's liver at 3 cm separation. A voltage of 8.5 V direct current (DC) at an average current of 30 mA was applied for 69 min; total charge was 124 coulombs. Concentrations of selected ions near the anode and cathode were measured. The concentrations of Na+ and K+ ions were higher around the cathode, whereas the concentration of Cl ions was higher around the anode. Water contents and pH were determined near the anode and the cathode at the midpoint between the two electrodes and in an untreated area away from the electrodes. Hydration occurred around the cathode, and dehydration occurred around the anode. The pH values were 2.1 near the anode and 12.9 near the cathode. Spectrophotometric scans of the liver sample extract were obtained, and the released gases were identified by gas chromatography as chlorine at the anode and hydrogen at the cathode. These results indicate that a series of electrochemical reactions take place during ECT. The cell metabolism and its environment are severely disturbed. Both normal and tumor cells are rapidly and completely destroyed in this altered environment. We believe that the above reactions are the ECT mechanisms for treating tumors. Bioelectromagnetics 18:2–7, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

15.
Ammonia losses during swine wastewater treatment were examined using single- and two-chambered microbial fuel cells (MFCs). Ammonia removal was 60% over 5 days for a single-chamber MFC with the cathode exposed to air (air-cathode), versus 69% over 13 days from the anode chamber in a two-chamber MFC with a ferricyanide catholyte. In both types of systems, ammonia losses were accelerated with electricity generation. For the air-cathode system, our results suggest that nitrogen losses during electricity generation were increased due to ammonia volatilization with conversion of ammonium ion to the more volatile ammonia species as a result of an elevated pH near the cathode (where protons are consumed). This loss mechanism was supported by abiotic tests (applied voltage of 1.1 V). In a two-chamber MFC, nitrogen losses were primarily due to ammonium ion diffusion through the membrane connecting the anode and cathode chambers. This loss was higher with electricity generation as the rate of ammonium transport was increased by charge transfer across the membrane. Ammonia was not found to be used as a substrate for electricity generation, as intermittent ammonia injections did not produce power. The ammonia-oxidizing bacterium Nitrosomonas europaea was found on the cathode electrode of the single-chamber system, supporting evidence of biological nitrification, but anaerobic ammonia-oxidizing bacteria were not detected by molecular analyses. It is concluded that ammonia losses from the anode chamber were driven primarily by physical-chemical factors that are increased with electricity generation, although some losses may occur through biological nitrification and denitrification.  相似文献   

16.
Decolorization of dye wastewater before discharge is pivotal because of its immense color and toxicities. In this study, a granular activated carbon based microbial fuel cell (GACB-MFC) was used without using any expensive materials like Nafion membrane and platinum catalyst for simultaneous decolorization of real dye wastewater and bioelectricity generation. After 48 hours of GACB-MFC operation, 73% color was removed at anode and 77% color was removed at cathode. COD removal was 71% at the anode and 76% at the cathode after 48 hours. Toxicity measurements showed that cathode effluent was almost nontoxic after 24 hours. The anode effluent was threefold less toxic compared to original dye wastewater after 48 hours. The GACB-MFC produced a power density of 1.7 W/m(3) with an open circuit voltage 0.45 V. One of the advantages of the GACB-MFC system is that pH was automatically adjusted from 12.4 to 7.2 and 8.0 at the anode and cathode during 48 hours operation.  相似文献   

17.
Scaling up microbial fuel cells (MFCs) requires a better understanding the importance of the different factors such as electrode surface area and reactor geometry relative to solution conditions such as conductivity and substrate concentration. It is shown here that the substrate concentration has significant effect on anode but not cathode performance, while the solution conductivity has a significant effect on the cathode but not the anode. The cathode surface area is always important for increasing power. Doubling the cathode size can increase power by 62% with domestic wastewater, but doubling the anode size increases power by 12%. Volumetric power density was shown to be a linear function of cathode specific surface area (ratio of cathode surface area to reactor volume), but the impact of cathode size on power generation depended on the substrate strength (COD) and conductivity. These results demonstrate the cathode specific surface area is the most critical factor for scaling-up MFCs to obtain high power densities.  相似文献   

18.
This study demonstrates for the first time a room temperature sodium–sulfur (RT Na–S) full cell assembled based on a pristine hard carbon (HC) anode combined with a nanostructured Na2S/C cathode. The development of cells without the demanding, time‐consuming and costly pre‐sodiation of the HC anode is essential for the realization of practically relevant RT Na–S prototype batteries. New approaches for Na2S/C cathode fabrication employing carbothermal reduction of Na2SO4 at varying temperatures (660 to 1060 °C) are presented. Initial evaluation of the resulting cathodes in a dedicated cell setup reveals 36 stable cycles and a capacity of 740 mAh gS?1, which correlates to ≈85% of the maximum value known from literature on Na2S‐based cells. The Na2S/C cathode with the highest capacity utilization is implemented into a full cell concept applying a pristine HC anode. Various full cell electrolyte compositions with fluoroethylene carbonate (FEC) additive have been combined with a special charging procedure during the first cycle supporting in situ solid electrolyte interphase (SEI) formation on the HC anode to obtain increased cycling stability and cathode utilization. The best performing cell setup has delivered a total of 350 mAh gS?1, representing the first functional full cell based on a Na2S/C cathode and a pristine HC anode today.  相似文献   

19.
本实验对臭鼩的血清蛋白及心肌、骨骼肌、肾脏、脾脏、肝脏,睾丸6种组织器官的乳酸脱氢酶(LDH)同工酶进行了聚丙烯酰胺凝胶盘状电泳的分析研究。臭鼩血清蛋白存在15—17条带,各组织的LDH同工酶均由5条带构成,其中心肌LDH-1、LDH-2和肾脏LDH-1各出现1条亚带。  相似文献   

20.
A new one-compartment fuel cell was composed of a rubber bunged bottle with a center-inserted anode and a window-mounted cathode containing an internal, proton-permeable porcelain layer. This fuel cell design was less expensive and more practical than the conventional two-compartment system, which requires aeration and a ferricyanide solution in the cathode compartment. Three new electrodes containing bound electron mediators including a Mn(4+)-graphite anode, a neutral red (NR) covalently linked woven graphite anode, and an Fe(3+)-graphite cathode were developed that greatly enhanced electrical energy production (i.e., microbial electron transfer) over conventional graphite electrodes. The potentials of these electrodes measured by cyclic voltametry at pH 7.0 were (in volts): +0.493 (Fe(3+)-graphite); +0.15 (Mn(4+)-graphite); and -0.53 (NR-woven graphite). The maximal electrical productivities obtained with sewage sludge as the biocatalyst and using a Mn(4+)-graphite anode and a Fe(3+)-graphite cathode were 14 mA current, 0.45 V potential, 1,750 mA/m(2) current density, and 788 mW/m(2) of power density. With Escherichia coli as the biocatalyst and using a Mn(4+)-graphite anode and a Fe(3+)-graphite cathode, the maximal electrical productivities obtained were 2.6 mA current, 0.28 V potential, 325 mA/m(2) current density, and 91 mW/m(2) of power density. These results show that the amount of electrical energy produced by microbial fuel cells can be increased 1,000-fold by incorporating electron mediators into graphite electrodes. These results also imply that sewage sludge may contain unique electrophilic microbes that transfer electrons more readily than E. coli and that microbial fuel cells using the new Mn(4+)-graphite anode and Fe(3+)-graphite cathode may have commercial utility for producing low amounts of electrical power needed in remote locations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号