首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
MS‐based strategies are key technologies for identifying proteins in proteomic research. Despite significant improvements in recent years efficient fractionation processes of target analytes remain major bottlenecks in MS‐based protein analysis. Immunoaffinity‐based sample fractionation strategies have shown their potential for the enrichment of analyte peptides of interest, but only small numbers of analytes can be quantified in one experiment. The lack of appropriate capture reagents limits the application of immunoaffinity‐based approaches and only biased biomarker discovery approaches are possible. This perspective discusses the current status of immunoaffinity MS‐based approaches and introduces a novel concept that uses group specific anti‐peptide antibodies – Triple X Proteomics Antibodies – for the enrichment of signature peptides. Classes of peptides with identical termini can be fractionated based on TXP immunoaffinity enrichment steps and can subsequently be identified using established tandem MS procedures. Based on bioinformatic algorithms minimal sets of TXP epitopes can be specified, that cover a wide range of given proteome landscapes of one or even several different species. This opens the possibility to use a minimal number of TXP antibodies as a universal toolbox for general immunoaffinity‐based approaches in proteome analysis.  相似文献   

2.
Biomarker discovery produces lists of candidate markers whose presence and level must be subsequently verified in serum or plasma. Verification represents a paradigm shift from unbiased discovery approaches to targeted, hypothesis-driven methods and relies upon specific, quantitative assays optimized for the selective detection of target proteins. Many protein biomarkers of clinical currency are present at or below the nanogram/milliliter range in plasma and have been inaccessible to date by MS-based methods. Using multiple reaction monitoring coupled with stable isotope dilution mass spectrometry, we describe here the development of quantitative, multiplexed assays for six proteins in plasma that achieve limits of quantitation in the 1-10 ng/ml range with percent coefficients of variation from 3 to 15% without immunoaffinity enrichment of either proteins or peptides. Sample processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate biomarker proteins were developed and optimized by addition of exogenous proteins to immunoaffinity depleted plasma from a healthy donor. Quantitative multiple reaction monitoring assays were designed and optimized for signature peptides derived from the test proteins. Based upon calibration curves using known concentrations of spiked protein in plasma, we determined that each target protein had at least one signature peptide with a limit of quantitation in the 1-10 ng/ml range and linearity typically over 2 orders of magnitude in the measurement range of interest. Limits of detection were frequently in the high picogram/milliliter range. These levels of assay performance represent up to a 1000-fold improvement compared with direct analysis of proteins in plasma by MS and were achieved by simple, robust sample processing involving abundant protein depletion and minimal fractionation by strong cation exchange chromatography at the peptide level prior to LC-multiple reaction monitoring/MS. The methods presented here provide a solid basis for developing quantitative MS-based assays of low level proteins in blood.  相似文献   

3.
Affinity separation and enrichment methods in proteomic analysis   总被引:2,自引:0,他引:2  
Protein separation or enrichment is one of the rate-limiting steps in proteomic studies. Specific capture and removal of highly-abundant proteins (HAP) with large sample-handling capacities are in great demand for enabling detection and analysis of low-abundant proteins (LAP). How to grasp and enrich these specific proteins or LAP in complex protein mixtures is also an outstanding challenge for biomarker discovery and validation. In response to these needs, various approaches for removal of HAP or capture of LAP in biological fluids, particularly in plasma or serum, have been developed. Among them, immunoaffinity subtraction methods based upon polyclonal IgY or IgG antibodies have shown to possess unique advantages for proteomic analysis of plasma, serum and other biological samples. In addition, other affinity methods that use recombinant proteins, lectins, peptides, or chemical ligands have also been developed and applied to LAP capture or enrichment. This review discusses in detail the need to put technologies and methods in affinity subtraction or enrichment into a context of proteomic and systems biology as "Separomics" and provides a prospective of affinity-mediated proteomics. Specific products, along with their features, advantages, and disadvantages will also be discussed.  相似文献   

4.
5.
6.
Phosphorylation of protein tyrosine residues regulates important cell functions and is, when dysregulated, often crucially involved in oncogenesis. It is therefore important to develop and evaluate methods for identifying and studying tyrosine phosphorylated (P-Tyr) proteins. P-Tyr proteins are present at very low concentrations within cells, requiring highly selective enrichment methods to be detected. In this study, we applied immunoaffinity as enrichment step for P-Tyr proteins. Five selected anti-phosphotyrosine antibodies (monoclonal antibodies 4G10, PY100, PYKD1, 13F9 and one polyclonal antiserum) were evaluated with respect to their capability to enrich P-Tyr proteins from cell extracts of the K562 leukemia cell line. The enrichment resulted in the detection of a group of proteins that potentially were tyrosine-phosphorylated (putative P-Tyr proteins). High accuracy identification of actual P-Tyr sites were performed using a highly selective and sensitive liquid chromatography Fourier transform mass spectrometer (LC-FTMS) setup with complementary collision activated dissociation (CAD) and electron capture dissociation (ECD) fragmentations. 4G10 and PY100 antibodies recognized the greatest number of putative P-Tyr proteins in initial screening experiments and were therefore further evaluated and compared in immunoaffinity enrichment of both P-Tyr proteins and peptides. Using the 4G10 antibody for enrichment of proteins, we identified 459 putative P-Tyr proteins by MS. Out of these proteins, 12 were directly verified as P-Tyr proteins by MS analysis of the actual site. Using the PY100 antibody for enrichment of peptides, we detected 67 P-Tyr peptides (sites) and 89 putative P-Tyr proteins. Generally, enrichment at the peptide level made it difficult to reliably determine the identity of the proteins. In contrast, protein identification following immunoaffinity enrichment at the protein level gave greater sequence coverage and thus a higher confidence in the protein identification. By combining all available information, 40 proteins were identified as true P-Tyr proteins from the K562 cell line. In conclusion, this study showed that a combination of immunoaffinity enrichment using multiple antibodies of both intact and digested proteins in parallel experiments is required for best possible coverage of all possible P-Tyr proteins in a sample.  相似文献   

7.
Mass spectrometry and peptide-centric approaches are powerful techniques for the identification of differentially expressed proteins. Despite enormous improvements in MS technologies, sample preparation and efficient fractionation of target analytes are still major bottlenecks in MS-based protein analysis. The complexity of tryptically digested whole proteomes needs to be considerably reduced before low abundance proteins can be effectively analyzed using MS/MS. Sample preparation strategies that use peptide-specific antibodies are able to reduce the complexity of tryptic digests and lead to a substantial increase in throughput and sensitivity; however, the number of peptide-specific capture reagents is low, and consequently immunoaffinity-based approaches are only capable of detecting small sets of protein-derived peptides. In this proof-of-principle study, special anti-peptide antibodies were used to enrich peptides from a complex mixture. These antibodies recognize short amino acid sequences that are found directly at the termini of the peptides. The recognized epitopes consist of three or four amino acids only and include the terminally charged group of the peptide. Because of its limited length, antibodies recognizing the epitope will enrich not only one peptide but a whole class of peptides that share this terminal epitope. In this study, β-catenin-derived peptides were used to demonstrate that it is possible (i) to effectively generate antibodies that recognize short C-terminal peptide epitopes and (ii) to enrich and identify peptide classes from a complex mixture using these antibodies in an immunoaffinity MS approach. The expected β-catenin peptides and a set of 38 epitope-containing peptides were identified from trypsin-digested cell lysates. This might be a first step in the development of proteomics applications that are based on the use of peptide class-specific antibodies.  相似文献   

8.
Separation of complex protein mixtures that have a wide dynamic range of concentration, such as plasma or serum, is a challenge for proteomic analysis. Sample preparation to remove high-abundant proteins is essential for proteomics analysis. Immunoglobulin yolk (IgY) antibodies have unique and advantageous features that enable specific protein removal to aid in the detection of low-abundant proteins and biomarker discovery. This report describes the efficiency and effectiveness of IgY microbeads in separating 12 abundant proteins from plasma with an immunoaffinity spin column or LC column. The protein separation and sample preparation process was monitored via SDS-PAGE, 2-DE, LC-MS/MS, or clinical protein assays. The data demonstrate the high specificity of the protein separation, with removal of 95-99.5% of the abundant proteins. IgY microbeads against human proteins can also selectively remove orthologous proteins of other mammals such as mouse, rat, etc. Besides the specificity and reproducibility of the IgY microbeads, the report discusses the factors that may cause potential variations in protein separation such as protein-protein interactions (known as "Interactome"), binding and washing conditions of immunoaffinity reagents, etc. A novel concept of Seppromics is introduced to address methodologies and science of protein separation in a context of proteomics.  相似文献   

9.
The enormous dynamic range of human bodily fluid proteomes poses a significant challenge for current MS-based proteomics technologies as it makes it especially difficult to detect low abundance proteins in human biofluids such as blood plasma, which is an essential aspect for successful biomarker discovery efforts. Here we present a novel tandem IgY12-SuperMix immunoaffinity separation system for enhanced detection of low abundance proteins in human plasma. The tandem IgY12-SuperMix system separates approximately 60 abundant proteins from the low abundance proteins in plasma, allowing for significant enrichment of low abundance plasma proteins in the SuperMix flow-through fraction. High reproducibility of the tandem separations was observed in terms of both sample processing recovery and LC-MS/MS identification results based on spectral count data. The ability to quantitatively measure differential protein abundances following application of the tandem separations was demonstrated by spiking six non-human standard proteins at three different levels into plasma. A side-by-side comparison between the SuperMix flow-through and IgY12 flow-through samples analyzed by both one- and two-dimensional LC-MS/MS revealed a 60-80% increase in proteome coverage as a result of the SuperMix separations, suggesting significantly enhanced detection of low abundance proteins. A total of 695 plasma proteins were confidently identified in a single analysis (with a minimum of two peptides per protein) by coupling the tandem separation strategy with two-dimensional LC-MS/MS, including 42 proteins with reported normal concentrations of approximately 100 pg/ml to 100 ng/ml. The concentrations of two selected proteins, macrophage colony-stimulating factor 1 and matrix metalloproteinase-8, were independently validated by ELISA as 202 pg/ml and 12.4 ng/ml, respectively. Evaluation of binding efficiency revealed that 45 medium abundance proteins were efficiently captured by the SuperMix column with >90% retention. Taken together, these results illustrate the potential broad utilities of this tandem IgY12-SuperMix strategy for proteomics applications involving human biofluids where effectively addressing the dynamic range challenge of the specimen is imperative.  相似文献   

10.
To develop methods for studying phosphorylation of protein tyrosine residues is an important task since this protein modification regulates many cellular functions and often is involved in oncogenesis. An optimal protocol includes enrichment of tyrosine phosphorylated (pTyr) peptides or proteins, followed by a high resolving analytical method for identification of the enriched components. In this Methods paper, we describe a working strategy on how immunoaffinity enrichments, using anti-pTyr antibodies, combined with mass spectrometric (MS) analysis can be used to study the pTyr proteome. We describe in detail how our procedure was used to characterize the pTyr proteome of K562 leukemia cells. Important questions concerning the use of different anti-pTyr antibodies, enrichments performed at the peptide and/or the protein level, pooling of enrichments and requirements for the MS characterization are discussed.  相似文献   

11.
For the direct interrogation of peptides harboring covalently modified serines in nonribosomal peptide synthetases, streamlined methodologies described here employ proteolysis and reporter-coenzyme A analogues of four types. The chromophoric and fluorescent coenzyme A analogues pyrene-maleimidyl-S-CoA and BODIPY-FL-N-(2-aminoethyl)maleimidyl-S-CoA were enzymatically loaded onto the active site serines harbored in the ArCP, PCP1, and PCP2 thiolation domains of PchE and PchF, the nonribosomal peptide synthetases responsible for the biosynthesis of the siderophore pyochelin. During the chromatographic separation of cyanogen bromide digests, observation of the absorbance (at 338 and 504 nm) or fluorescence (after irradiation at 365 nm) enabled the selective detection of peptides containing each active site serine. This resulted in quick detection of each active site peptide by Fourier transform mass spectrometry in the fully reconstituted pyochelin system. The loading of short acyl chain reporters in equimolar quantities permitted further insights into digestion heterogeneity and side reactions by virtue of a mass shift signature on each active site peptide. The chromatographic shift of the reporter-loaded peptides relative to peptides carrying on pathway intermediates was 2 min at 7 kDa, providing a general strategy for efficient localization of "carrier" peptides in complex digests of thiotemplate enzymes. Also, the use of the affinity reporter, biotin-maleimidyl-S-coenzyme A, permitted the isolation of intact synthetases at high purity via removal of contaminating Escherichia coli proteins.  相似文献   

12.
Brand J  Haslberger T  Zolg W  Pestlin G  Palme S 《Proteomics》2006,6(11):3236-3242
The selective removal of high-abundance proteins is considered to be an important prerequisite for a sensitive proteome analysis in plasma. In this study, we examined the "multiaffinity removal system", an immunoaffinity depletion column targeted against six plasma proteins. As determined by sandwich ELISA, the depletion rate for each target protein is >99% over 200 cycles of regeneration. Our data give evidence that two column antibodies are slowly inactivated during the repeated use of the column; however, the individual depletion rate meets the specification of the manufacturer. To estimate a potential loss of analytes after the immunodepletion, we performed spiking/recovery experiments with a selection of tumor markers at concentrations in the lower to medium ng/mL range. The average recovery of 9 out of 11 markers is 78%. A significant proportion of two other markers binds to the column. Based on the average marker recovery and a depletion of ;85% of the total protein we estimate a five-fold enrichment of a potential biomarker by the use of this depletion column. We conclude that the selective depletion of plasma proteins by immunoaffinity chromatography is a valid strategy for the enrichment of potential biomarkers sought by proteomics methodologies.  相似文献   

13.
Targeted quantitative proteomics by mass spectrometry aims to selectively detect one or a panel of peptides/proteins in a complex sample and is particularly appealing for novel biomarker verification/validation because it does not require specific antibodies. Here, we demonstrated the application of targeted quantitative proteomics in searching, identifying, and quantifying selected peptides in human cerebrospinal spinal fluid (CSF) using a matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometer (MALDI TOF/TOF)-based platform. The approach involved two major components: the use of isotopic-labeled synthetic peptides as references for targeted identification and quantification and a highly selective mass spectrometric analysis based on the unique characteristics of the MALDI instrument. The platform provides high confidence for targeted peptide detection in a complex system and can potentially be developed into a high-throughput system. Using the liquid chromatography (LC) MALDI TOF/TOF platform and the complementary identification strategy, we were able to selectively identify and quantify a panel of targeted peptides in the whole proteome of CSF without prior depletion of abundant proteins. The effectiveness and robustness of the approach associated with different sample complexity, sample preparation strategies, as well as mass spectrometric quantification were evaluated. Other issues related to chromatography separation and the feasibility for high-throughput analysis were also discussed. Finally, we applied targeted quantitative proteomics to analyze a subset of previously identified candidate markers in CSF samples of patients with Parkinson's disease (PD) at different stages and Alzheimer's disease (AD) along with normal controls.  相似文献   

14.
Perchlorate is a known health hazard for humans, fish, and other species. Therefore, it is important to assess the response of an ecosystem exposed to perchlorate contamination. The data reported here show that a liquid chromatography-mass spectrometry-based proteomics approach for the detection of perchlorate-reducing enzymes can be used to measure the ability of microorganisms to degrade perchlorate, including determining the current perchlorate degradation status. Signature peptides derived from chlorite dismutase (CD) and perchlorate reductase can be used as biomarkers of perchlorate presence and biodegradation. Four peptides each derived from CD and perchlorate reductase subunit A (PcrA) and seven peptides derived from perchlorate reductase subunit B (PcrB) were identified as signature biomarkers for perchlorate degradation, as these sequences are conserved in the majority of the pure and mixed perchlorate-degrading microbial cultures examined. However, chlorite dismutase signature biomarker peptides from Dechloromonas agitata CKB were found to be different from those in other cultures used and should also be included with selected CD biomarkers. The combination of these peptides derived from the two enzymes represents a promising perchlorate presence/biodegradation biomarker system. The biomarker peptides were detected at perchlorate concentrations as low as 0.1 mM and at different time points both in pure cultures and within perchlorate-reducing environmental enrichment consortia. The peptide biomarkers were also detected in the simultaneous presence of perchlorate and an alternate electron acceptor, nitrate. We believe that this technique can be useful for monitoring bioremediation processes for other anthropogenic environmental contaminants with known metabolic pathways.  相似文献   

15.
Stable isotope standards and capture by antipeptide antibodies (SISCAPA) couples affinity enrichment of peptides with stable isotope dilution and detection by multiple reaction monitoring mass spectrometry to provide quantitative measurement of peptides as surrogates for their respective proteins. In this report, we describe a feasibility study to determine the success rate for production of suitable antibodies for SISCAPA assays in order to inform strategies for large-scale assay development. A workflow was designed that included a multiplex immunization strategy in which up to five proteotypic peptides from a single protein target were used to immunize individual rabbits. A total of 403 proteotypic tryptic peptides representing 89 protein targets were used as immunogens. Antipeptide antibody titers were measured by ELISA and 220 antipeptide antibodies representing 89 proteins were chosen for affinity purification. These antibodies were characterized with respect to their performance in SISCAPA-multiple reaction monitoring assays using trypsin-digested human plasma matrix. More than half of the assays generated were capable of detecting the target peptide at concentrations of less than 0.5 fmol/μl in human plasma, corresponding to protein concentrations of less than 100 ng/ml. The strategy of multiplexing five peptide immunogens was successful in generating a working assay for 100% of the targeted proteins in this evaluation study. These results indicate it is feasible for a single laboratory to develop hundreds of assays per year and allow planning for cost-effective generation of SISCAPA assays.  相似文献   

16.
The diversity and complexity of proteins and peptides in biological systems requires powerful liquid chromatography-based separations to optimize resolution and detection of components. Proteomics strategies often combine two orthogonal separation modes to meet this challenge. In nearly all cases, the second dimension is a reverse phase separation interfaced directly to a mass spectrometer. Here we report on the use of hydrophilic interaction chromatography (HILIC) as part of a multidimensional chromatography strategy for proteomics. Tryptic peptides are separated on TSKgel Amide-80 columns using a shallow inverse organic gradient. Under these conditions, peptide retention is based on overall hydrophilicity, and a separation truly orthogonal to reverse phase is produced. Analysis of tryptic digests from HeLa cells yielded numbers of protein identifications comparable to that obtained using strong cation exchange. We also demonstrate that HILIC represents a significant advance in phosphoproteomics analysis. We exploited the strong hydrophilicity of the phosphate group to selectively enrich and fractionate phosphopeptides based on their increased retention under HILIC conditions. Subsequent IMAC enrichment of phosphopeptides from HILIC fractions showed better than 99% selectivity. This was achieved without the use of derivatization or chemical modifiers. In a 300-microg equivalent of HeLa cell lysate we identified over 1000 unique phosphorylation sites. More than 700 novel sites were added to the HeLa phosphoproteome.  相似文献   

17.
Døskeland AP 《Amino acids》2006,30(1):99-103
Summary. A simple method is described to identify signature peptides derived from polyubiquitin (polyUb) chains. The method is based on MALDI-TOF MS/MS analysis after chemically assisted fragmentation, and works on peptides isolated from polyacrylamide gels. PolyUb chains branched at K48 and K63 were chosen as models for Ub-protein conjugates. They were resolved by SDS-PAGE, and their tryptic peptides (in-gel-trypsinolysis) derivatized with 3-sulfopropinic acid NHSester to obtain chemically assisted fragmentation during the MS/MS analysis. PolyUb-K63 produced a single peptide identified as 55TLSDYNIQK63 (GG)ESTLHLVLR72. PolyUb-K48 produced two branched signature peptides identified as 43LIFAGK48(GG)QLEDGR54 and 43LIFAGK48(LRGG)QLEDGR54. The recovery of signature peptide with LRGG as branched chain underscores the need to take limited proteolysis into account in the search for detection of ubiquitinated peptides in proteomics studies. In conclusion, a simple method has been described allowing the identification of signature peptides, which are diagnostic markers of the majority of polyUb-conjugated proteins. In principle, the method should be applicable also for other more rare signature peptides.  相似文献   

18.
This report describes an integrated and modular microsystem providing rapid analyses of trace-level tryptic digests for proteomics applications. This microsystem includes an autosampler, a microfabricated device comprising a large channel (2.4 microl total volume), an array of separation channels, together with a low dead volume enabling the interface to nanoelectrospray mass spectrometry. The large channel of this microfluidic device provides a convenient platform to integrate C(18) reverse phase packing or other type of affinity media such as immobilized antibodies or immobilized metal affinity chromatography beads thus enabling affinity selection of target peptides prior to electrophoretic separation and mass spectrometry analyses on a quadrupole/time-of-flight instrument. Sequential injection, preconcentration, and separation of peptide standards and tryptic digests are achieved with a throughput of up to 12 samples/per h and a concentration detection limit of approximately 5 nM (25 fmol on chip). Replicate injections of peptide mixtures indicated that reproducibility of migration time was 1.2-1.8%, whereas relative standard deviation ranging from 9.2 to 11.8% are observed on peak heights. The application of this device for trace-level protein identification is demonstrated for two-dimensional gel spots obtained from extracts of human prostatic cancer cells (LNCap) using both peptide mass-fingerprint data base searching and on-line tandem mass spectrometry. Enrichment of target peptides prior to mass spectral analyses is achieved using c-myc-specific antibodies immobilized on protein G-Sepharose beads and facilitates the identification of antigenic peptides spiked at a level of 20 ng/ml in human plasma. Affinity selection is also demonstrated for gel-isolated protein bands where tryptic phosphopeptides are captured on immobilized metal affinity chromatography beads and subsequently separated and characterized on this microfluidic system.  相似文献   

19.
An alternative strategy for mitochondrial proteomics is described that is complementary to previous investigations using 2D PAGE techniques. The strategy involves (a) obtaining highly purified preparations of human heart mitochondria using metrizamide gradients to remove cytosolic and other subcellular contaminant proteins; (b) separation of mitochondrial protein complexes using sucrose density gradients after solubilization with n-dodecyl-beta-D-maltoside; (c) 1D electrophoresis of the sucrose gradient fractions; (d) high-throughput proteomics using robotic gel band excision, in-gel digestion, MALDI target spotting and automated spectral acquisition; and (e) protein identification from mixtures of tryptic peptides by high-precision peptide mass fingerprinting. Using this approach, we rapidly identified 82 bona fide or potential mitochondrial proteins, 40 of which have not been previously reported using 2D PAGE techniques. These proteins include small complex I and complex IV subunits, as well as very basic and hydrophobic transmembrane proteins such as the adenine nucleotide translocase that are not recovered in 2D gels. The technique described here should also be useful for the identification of new protein-protein associations as exemplified by the validation of a recently discovered complex that involves proteins belonging to the prohibitin family.  相似文献   

20.
Trypsin is the most frequently used proteolytic enzyme in mass spectrometry-based proteomics. Beside its good availability, it also offers some major advantages such as an optimal average peptide length of ~ 14 amino acids, and typically the presence of at least two defined positive charges at the N-terminus as well as the C-terminal Arg/Lys, rendering tryptic peptides well suited for CID-based LC-MS/MS. Here, we conducted a systematic study of different types of commercially available trypsin in order to qualitatively and quantitatively compare cleavage specificity, efficiency as well as reproducibility and the potential impact on quantitation and proteome coverage. We present a straightforward strategy applied to complex digests of human platelets, comprising (1) digest controls using a monolithic column HPLC-setup, (2) SCX enrichment of semitryptic/nonspecific peptides, (3) targeted MRM analysis of corresponding full cleavage/missed cleavage peptide pairs as well as (4) LC-MS analyses of complete digests with a three-step data interpretation. Thus, differences in digest performance can be readily assessed, rendering these procedures extremely beneficial to quality control not only the trypsin of choice, but also to effectively compare as well as optimize different digestion conditions and to evaluate the reproducibility of a dedicated digest protocol for all kinds of quantitative proteome studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号