 共查询到20条相似文献,搜索用时 15 毫秒
1.
Three detection methods for Legionella species in water samples from cooling towers and a river were examined. Direct counting of bacteria stained with fluorescent antibody (FA) for L. pneumophila (serogroups 1 to 6) could detect the cell of 104 to 106 cell/100 ml in all 14 samples, while colony counting method detected 10 to 103 CFU/100 ml only in 8 samples from cooling towers. Polymerase chain reaction (PCR) assay with primers to amplify 16S ribosomal DNA sequence of most Legionella species (LEG primer) detected legionellae in 13 samples, while species-specific primers for L. pneumophila detected the DNAs from 3 samples. In laboratory examination, LEG primers could amplify DNAs of 29 species of genus Legionella with high sensitivity, even from 1 cell of L. pneumophila GIFU 9134. The PCR assay with LEG primers was specific and sensitive methods to be satisfied the survey of legionellae. Thus, PCR assay is a suitable method to detect and monitor Legionella species in an environment.  相似文献   

2.
Genotypic variability and clonal persistence are important concepts in molecular epidemiology as they facilitate the search for the source of sporadic cases or outbreaks of legionellosis. We studied the genotypic variability and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns over time (period > 6 months) in 34 positive cooling towers from two different areas. In area A, radius of 70 km, 52 indistinguishable PFGE patterns were differentiated among the 27 cooling towers. In 13 cooling towers we observed ≥ 2 PFGE patterns. Each cooling tower had its own indistinguishable Legionella PFGE pattern which was not shared with any other cooling tower. In area B, radius of 1 km, 10 indistinguishable PFGE patterns were obtained from the seven cooling towers. In four, we observed ≥ 2 PFGE patterns. Three of these 10 indistinguishable PFGE patterns were shared by more than one cooling tower. In 27 of 34 cooling towers the same PFGE pattern was recovered after 6 months to up to 5 years of follow-up. The large genotypic diversity of Legionella observed in the cooling towers aids in the investigation of community outbreaks of Legionnaires' disease. However, shared patterns in small areas may confound the epidemiological investigation. The persistence of some PFGE patterns in cooling towers makes the recovery of the Legionella isolate causing the outbreak possible over time.  相似文献   

3.
Aims: To optimize ethidium monoazide (EMA) coupled with real‐time quantitative PCR (qPCR) and to evaluate its environmental applicability on quantifying viable legionellae in water and biofilm of cooling towers and hot water systems. Methods and Results: EMA (0·9–45·5 μg ml?1) and propidium monoazide (PMA, 0·9 and 2·3 μg ml?1) combined with qPCR (i.e. EMA‐qPCR and PMA‐qPCR, respectively) were applied to unheated and heated (70°C for 30 min) Legionella pneumophila to quantify viable cells, which was also simultaneously determined by BacLight Bacterial Viability kit with epifluorogenic microscopic enumeration (BacLight‐EM). The effects of nontarget microflora and sample matrix on the performance of EMA‐qPCR were also evaluated. In comparison with BacLight‐EM results, qPCR with EMA at 2·3 μg ml?1 was determined as the optimal EMA‐qPCR assay, which performed equally well as PMA‐qPCR for unheated Leg. pneumophila but better than PMA‐qPCR for heated Leg. pneumophila (P < 0·05). Moreover, qPCR with EMA at 2·3 μg ml?1 accurately quantified viable Leg. pneumophila, Legionella anisa and Legionella‐like amoebal pathogens 6 (LLAP 6) without interferences by heated legionellae, unheated nonlegionellae cells and cooling tower water matrix (P > 0·05). As for water and biofilm samples collected from cooling towers and hot water systems, the viable legionellae counts determined by EMA‐qPCR were mostly greater than the culturable counts by culture assay but consistently lower than the total cell counts quantified by qPCR. Conclusions: The qPCR with EMA at 2·3 μg ml?1 may accurately quantify viable legionellae (including fastidious LLAP 6) and Leg. pneumophila pretreated with superheating and is applicable for water and biofilm samples obtained from cooling towers and hot water systems. Significance and Impact of the Study: The EMA‐qPCR assay may be useful in environmental surveillance for viable legionellae and in evaluation of superheating efficacy against legionellae.  相似文献   

4.
Our survey of cooling tower water demonstrated that the highest density of legionellae, ≥104 CFU/100 ml, appeared in water containing protozoa, ≥102 MPN/100 ml, and heterotrophic bacteria, ≥106 CFU/100 ml, at water temperatures between 25 and 35°C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 105 CFU/100 ml, occurs in summer. The counts of legionellae correlated positively with increases in water temperature, pH, and protozoan counts, but not with heterotrophic bacterial counts. The water temperature of cooling towers may promote increases in the viable counts of legionellae, and certain microbes, e.g., protozoa or some heterotrophic bacteria, may be a factor stimulating the propagation of legionellae.  相似文献   

5.
Investigation of epidemic outbreaks of Legionnaires disease by Center for Disease Control personnel has resulted in the isolation of Legionella pneumophila from water in the air-conditioning cooling towers or evaporative condensers at the site of the outbreak. It is suspected that improperly maintained open, recirculating water systems may play a role in the growth and dissemination of this pathogen. The objective of this study was to determine the antimicrobial activity of three chemically different, commercially available, cooling tower microbicides against L. pneumophila. Using two in vitro test systems, a combination of N-alkyl dimethyl benzyl ammonium chloride and bis (tri-n-butyltin) oxide was found to kill L. pneumophila at a concentration 25 times less than the minimum recommended use concentration, whereas N-alkyl 1,3-propanediamine and methylene bis (thiocyanate) were active at concentrations equal to or greater than the concentrations recommended for use by the manufacturer.  相似文献   

6.
Legionnaires' disease (LD) outbreaks are often traced to colonized potable water systems. We collected water samples from potable water systems of 96 buildings in Pinellas County, Florida, between January and April 2002, during a time when chlorine was the primary residual disinfectant, and from the same buildings between June and September 2002, immediately after monochloramine was introduced into the municipal water system. Samples were cultured for legionellae and amoebae using standard methods. We determined predictors of Legionella colonization of individual buildings and of individual sampling sites. During the chlorine phase, 19 (19.8%) buildings were colonized with legionellae in at least one sampling site. During the monochloramine phase, six (6.2%) buildings were colonized. In the chlorine phase, predictors of Legionella colonization included water source (source B compared to all others, adjusted odds ratio [aOR], 6.7; 95% confidence interval [CI], 2.0 to 23) and the presence of a system with continuously circulating hot water (aOR, 9.8; 95% CI, 1.9 to 51). In the monochloramine phase, there were no predictors of individual building colonization, although we observed a trend toward greater effectiveness of monochloramine in hotels and single-family homes than in county government buildings. The presence of amoebae predicted Legionella colonization at individual sampling sites in both phases (OR ranged from 15 to 46, depending on the phase and sampling site). The routine introduction of monochloramine into a municipal drinking water system appears to have reduced colonization by Legionella spp. in buildings served by the system. Monochloramine may hold promise as community-wide intervention for the prevention of LD.  相似文献   

7.
The effects of biocidal treatments for cooling towers were examined through the use of chemicals and ultraviolet irradiation to inhibit the growth of legionellae and other microorganisms. In the water of cooling towers without continuous biocidal treatments, heterotrophic bacteria and bacterivorous protozoan first appeared, and then legionellae increased up to 10(4) CFU/100 ml. When a UV sterilizer was connected to the cooling tower, the legionellae count was 1/10 or 1/100 of that in the nontreated tower water. In the water of towers supplemented continuously with the biocidal chemicals, legionellae were not found during a 4-month period. The biocidal treatments tested were proved to suppress the increase of legionellae in cooling-tower water, and thus are useful in preventing the outbreak of legionellosis due to inhalation of contaminated aerosol from the cooling tower system.  相似文献   

8.
Legionnaires' disease (LD) outbreaks are often traced to colonized potable water systems. We collected water samples from potable water systems of 96 buildings in Pinellas County, Florida, between January and April 2002, during a time when chlorine was the primary residual disinfectant, and from the same buildings between June and September 2002, immediately after monochloramine was introduced into the municipal water system. Samples were cultured for legionellae and amoebae using standard methods. We determined predictors of Legionella colonization of individual buildings and of individual sampling sites. During the chlorine phase, 19 (19.8%) buildings were colonized with legionellae in at least one sampling site. During the monochloramine phase, six (6.2%) buildings were colonized. In the chlorine phase, predictors of Legionella colonization included water source (source B compared to all others, adjusted odds ratio [aOR], 6.7; 95% confidence interval [CI], 2.0 to 23) and the presence of a system with continuously circulating hot water (aOR, 9.8; 95% CI, 1.9 to 51). In the monochloramine phase, there were no predictors of individual building colonization, although we observed a trend toward greater effectiveness of monochloramine in hotels and single-family homes than in county government buildings. The presence of amoebae predicted Legionella colonization at individual sampling sites in both phases (OR ranged from 15 to 46, depending on the phase and sampling site). The routine introduction of monochloramine into a municipal drinking water system appears to have reduced colonization by Legionella spp. in buildings served by the system. Monochloramine may hold promise as community-wide intervention for the prevention of LD.  相似文献   

9.
Survival of protozoa in cooling tower biocides   总被引:2,自引:0,他引:2  
Protozoa from cooling towers may serve as hosts for legionellae, but such protozoa have not been examined with respect to effects of cooling tower biocides. In this study, two ciliate species,Tetrahymena sp andColpoda sp, and two amoebae species,Vannella miroides andAcanthamoeba hatchetti, were isolated from a cooling tower and tested for survival in the presence of four cooling tower biocides. The protozoa were exposed for 24 h to a thiocarbamate compound, an isothiazolone compound, quaternary ammonium compounds (QAC), and tributyltin neodecanoate with quarternary ammonium compounds (TBT/QAC). After exposure, cells were examined for viability. The highest concentration of each biocide in which cells could survive was compared to the manufacturers' recommended maintenance dosage (MRMD) of the biocides.Tetrahymena andColpoda survived concentrations within the range of the MRMD of thiocarbamate and QAC.Vannella andAcanthamoeba survived concentrations within the MRMD of thiocarbamate, isothiazolone, and QAC.Colpoda cysts andAcanthamoebae cysts remained viable after exposure to concentrations much greater than the MRMD of thiocarbamate, isothiazolone, and QAC. None of the protozoa in any stage could survive the MRMD of TBT/QAC. These results show that protozoa indigenous to cooling towers may survive the recommended concentration of certain biocides, and this information may be important in devising procedures for eradicating hosts for legionellae.  相似文献   

10.
AIMS: Legionella pneumophila is a contaminant of man-made water systems, including potable water, cooling towers, water systems of large buildings, etc. It is the most common causative agent of legionellosis, a respiratory infection, which may give rise to restricted outbreaks. To survey environmental water samples from hospitals and private habitations in Bologna, we developed a species-specific nested and a TaqMan real-time PCR for the detection of L. pneumophila. We compared the two assays and both to cultural isolation. METHODS AND RESULTS: The targeted gene was macrophage infectivity potentiator (mip), conserved in L. pneumophila, and divergent in other legionellae. One assay was based on a nested PCR and the other on a TaqMan real-time PCR protocol. Their sensitivities were 14 % or 5% higher than that of cultural isolation respectively. The detection limits were 1-2 genome equivalents per 50-microl reaction. Specificity was assessed using DNA from nine target and 20 nontarget organisms. CONCLUSIONS: When applied to water samples, both assays detected L. pneumophila at 80% or higher frequency. SIGNIFICANCE AND IMPACT OF THE STUDY: The species-specific molecular diagnosis of L. pneumophila by means of nested PCR does not require a specific instrumentation, exhibits a high sensitivity, and is advantageous over the cultural isolation and real-time PCR detection. It allows to quickly monitor water samples for the risk assessment of environmental contaminations.  相似文献   

11.
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

12.
Protocol for sampling environmental sites for legionellae.   总被引:4,自引:2,他引:2       下载免费PDF全文
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

13.
A preliminary survey of water systems in hospitals and hotels showed that Legionella pneumophila may be found in water storage and distribution systems as well as in the recirculating cooling water of air-conditioning plants. Altogether 42 isolates of L pneumophila were made from 31 establishments, six of which were associated with cases of legionnaires'' disease but in 25 of which there was no known association with disease. In the six establishments implicated epidemiologically as the source of legionnaires'' disease, these organisms were found in each of their water-distribution systems and also in the cooling water from each of the three with cooling towers. In establishments not associated with cases, water from three out of nine cooling towers, four out of 24 taps or showers, and one out of 15 storage tanks was found to contain legionellae. The organisms were isolated by guinea-pig inoculation and subsequent culture of their peritoneal fluid, liver, and spleen. Finding L pneumophila in water systems in the absence of cases of legionnaires'' disease should not at present be an indication for attempts at eradication.  相似文献   

14.
Laboratory studies of disinfectants against Legionella pneumophila   总被引:5,自引:0,他引:5  
Legionella pneumophila suspended in tap water was exposed to biocides recommended for inhibiting biological growth in cooling towers and evaporative condensers of air-conditioning systems. Chlorine, 2,2-dibromo-3-nitrilopropionamide, and a compound containing didecyldimethylammonium chloride and isopropanol were effective in destroying concentratiois of 10(5) to 10(6) viable cells per ml. Formulations consisting of 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one, disodium ethylene bis(thiocarbamate) and sodium dimethyl dithiocarbamate, and a phenolic with pentachlorophenate and sodium salts of other chlorophenols were less effective.  相似文献   

15.
Laboratory studies of disinfectants against Legionella pneumophila.   总被引:10,自引:9,他引:1       下载免费PDF全文
Legionella pneumophila suspended in tap water was exposed to biocides recommended for inhibiting biological growth in cooling towers and evaporative condensers of air-conditioning systems. Chlorine, 2,2-dibromo-3-nitrilopropionamide, and a compound containing didecyldimethylammonium chloride and isopropanol were effective in destroying concentratiois of 10(5) to 10(6) viable cells per ml. Formulations consisting of 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one, disodium ethylene bis(thiocarbamate) and sodium dimethyl dithiocarbamate, and a phenolic with pentachlorophenate and sodium salts of other chlorophenols were less effective.  相似文献   

16.
We surveyed by use of medical questionnaires and blood tests 21 maintenance workers involved with cleaning and servicing cooling towers and evaporative condensers at a large company to determine the frequency of pneumonia and antibody levels against Legionella pneumophila serogroup 1. The 21 high-risk workers were compared with 27 low-risk workers, persons who were not directly involved in service or maintenance for the company. The overall prevalence of titers greater than or equal to 128 for the 21 high-risk workers was 19.0% compared with 22.2% for the low-risk group. There were no significant differences in the history of pneumonia between these groups. Possible explanations for these findings are discussed.  相似文献   

17.
18.
Aims: To perform an international trial to derive alert and action levels for the use of quantitative PCR (qPCR) in the monitoring of Legionella to determine the effectiveness of control measures against legionellae. Methods and Results: Laboratories (7) participated from six countries. Legionellae were determined by culture and qPCR methods with comparable detection limits. Systems were monitored over ≥10 weeks. For cooling towers (232 samples), there was a significant difference between the log mean difference between qPCR (GU l?1) and culture (CFU l?1) for Legionella pneumophila (0·71) and for Legionella spp. (2·03). In hot and cold water (506 samples), the differences were less, 0·62 for Leg. pneumophila and 1·05 for Legionella spp. Results for individual systems depended on the nature of the system and its treatment. In cooling towers, Legionella spp. GU l?1 always exceeded CFU l?1, and usually Legionella spp. were detected by qPCR when absent by culture. The pattern of results by qPCR for Leg. pneumophila followed the culture trend. In hot and cold water, culture and qPCR gave similar results, particularly for Leg. pneumophila. There were some marked exceptions with temperatures ≥50°C, or in the presence of supplementary biocides. Action and alert levels for qPCR were derived that gave results comparable to the application of the European Guidelines based on culture. Algorithms are proposed for the use of qPCR for routine monitoring. Conclusions: Action and alert levels for qPCR can be adjusted to ensure public health is protected with the benefit that remedial actions can be validated earlier with only a small increase in the frequency of action being required. Significance and Impact of the Study: This study confirms it is possible to derive guidelines on the use of qPCR for monitoring the control of legionellae with consequent improvement to response and public health protection.  相似文献   

19.
Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and time series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests. Received: 19 January 2000 / Accepted: 9 May 2000  相似文献   

20.
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.  相似文献   