Within the last few years, there has been a significant amount of progress using EPR oximetry, which has resulted in the availability of instrumentation and paramagnetic materials capable of measuring pO(2) in tissues with an accuracy and sensitivity comparable to or greater than that available by any other method. While the results obtained with EPR so far indicate that criteria for the measurements of pO(2)-such as accuracy, sensitivity, repeatability, and noninvasiveness-can be met, some of the paramagnetic materials with optimum spectroscopic properties (i.e., strong simple signals which are appropriately responsive to changes in pO(2)) may have some undesirable interactions with tissues, causing reactions with and/or losing responsiveness to oxygen. In this paper, several approaches are discussed, such as encapsulation procedures, which can result in the availability of oxygen-sensitive materials in a suitable configuration for long-term studies (absence of toxicity and preservation of the responsiveness to oxygen).  相似文献   

2.
The synthesis and characterization of a new lithium octa-n-butoxy-substituted naphthalocyanine radical probe (LiNc-BuO) and its use in the determination of concentration of oxygen (oximetry) by electron paramagnetic resonance (EPR) spectroscopy are reported. The probe is synthesized as a needle-shaped microcrystalline particulate. The particulate shows a single-line EPR spectrum that is highly exchange-narrowed with a line-width of 210 mG. The EPR line-width is sensitive to molecular oxygen showing a linear relationship between the line-width and concentration of oxygen (pO(2)) with a sensitivity of 8.5 mG/mmHg. We studied a variety of physicochemical and biological properties of LiNc-BuO particulates to evaluate the suitability of the probe for in vivo oximetry. The probe is unaffected by biological oxidoreductants, stable in tissues for several months, and can be successfully internalized in cells. We used this probe to monitor changes in concentration of oxygen in the normal muscle and RIF-1 tumor tissue of mice as a function of tumor growth. The data showed a rapid decrease in the tumor pO(2) with increase of tumor volume. Human arterial smooth muscle cells, upon internalization of the LiNc-BuO probe, showed a marked oxygen gradient across the cell membrane. In summary, the newly synthesized octa-n-butoxy derivative of lithium naphthalocyanine has unique properties that are useful for determining oxygen concentration in chemical and biological systems by EPR spectroscopy and also for magnetic tagging of cells.  相似文献   

3.
Electron paramagnetic resonance (EPR) oximetry is being widely used to measure the oxygen consumption of cells, mitochondria, and submitochondrial particles. However, further improvement of this technique, in terms of data analysis, is required to use it as a quantitative tool. Here, we present a new approach for quantitative analysis of cellular respiration using EPR oximetry. The course of oxygen consumption by cells in suspension has been observed to have three distinct zones: pO(2)-independent respiration at higher pO(2) ranges, pO(2)-dependent respiration at low pO(2) ranges, and a static equilibrium with no change in pO(2) at very low pO(2) values. The approach here enables one to comprehensively analyze all of the three zones together-where the progression of O(2) diffusion zones around each cell, their overlap within time, and their potential impact on the measured pO(2) data are considered. The obtained results agree with previously established methods such as high-resolution respirometry measurements. Additionally, it is also demonstrated how the diffusion limitations can depend on cell density and consumption rate. In conclusion, the new approach establishes a more accurate and meaningful model to evaluate the EPR oximetry data on cellular respiration to quantify related parameters using EPR oximetry.  相似文献   

4.
The purpose of this study was to determine the rate of oxygen consumption in mouse aortic endothelial cells (MAECs) and to determine the effect of a variety of inhibitors and stimulators of oxygen consumption measured by electron paramagnetic resonance (EPR) spectroscopy utilizing a new particulate oximetry probe. We have previously demonstrated that the octa-n-butoxy derivative of naphthalocyanine neutral radical (LiNc-BuO) enables accurate, precise, and reproducible measurements of pO(2) in cellular suspensions. In the current study, we carried out measurements to provide an accurate determination of pO(2) in small volume with less number of cells (20,000 cells) that has not been possible with other techniques. To establish the reliability of this method, agents such as menadione, lipopolysaccharide (LPS), potassium cyanide, rotenone, and diphenyleneiodonium chloride (DPI) were used to modulate the oxygen consumption rate in the cells. We observed an increase in oxygen consumption by the cells upon treatment with menadione and LPS, whereas treatment with cyanide, rotenone, and DPI inhibited oxygen consumption. This study clearly demonstrated the utilization of EPR spectrometry with LiNc-BuO probe for determination of oxygen concentration in cultured cells.  相似文献   

5.
Methods currently available for the measurement of oxygen concentrations (oximetry) in viable tissues differ widely from each other in their methodological basis and applicability. The goal of this study was to compare two novel methods, particulate-based electron paramagnetic resonance (EPR) and OxyLite oximetry, in an experimental tumor model. EPR oximetry uses implantable paramagnetic particulates, whereas OxyLite uses fluorescent probes affixed on a fiber-optic cable. C3H mice were transplanted with radiation-induced fibrosarcoma (RIF-1) tumors in their hind limbs. Lithium phthalocyanine (LiPc) microcrystals were used as EPR probes. The pO(2) measurements were taken from random locations at a depth of approximately 3 mm within the tumor either immediately or 48 h after implantation of LiPc. Both methods revealed significant hypoxia in the tumor. However, there were striking differences between the EPR and OxyLite readings. The differences were attributed to the volume of tissue under examination and the effect of needle invasion at the site of measurement. This study recognizes the unique benefits of EPR oximetry in terms of robustness, repeatability and minimal invasiveness.  相似文献   

6.
A new electron paramagnetic resonance (EPR) oximetry probe, based on a naphthalocyanine macrocycle, is reported to exhibit high oxygen sensitivity and favorable EPR characteristics for biological applications. The free radical probe, lithium naphthalocyanine (LiNc), is synthesized as fine microcrystalline powder with particle size less than 1 microm and high spin density. It exhibits a single sharp EPR peak, whose width varies linearly with oxygen partial pressure (pO2). The EPR spectrum is nonsaturable at typical microwave power levels (< 25 mW at X-band). These unique characteristics make this probe ideal for measuring oxygen concentration in biological tissues, in vivo. The peak-to-peak width under anoxic conditions is 0.51 G (at X-band), and it increases linearly with increase in oxygen partial pressure and reaches 26.0 G for 100% oxygen (760 mmHg), showing an oxygen sensitivity of 34 mG/mmHg. The probe responds to changes in pO2 quickly and reproducibly, thus enabling dynamic measurements of regional oxygenation in real time. The application of this probe for oximetry is demonstrated in an in vivo biological system. The changes in pO2 were monitored in the leg muscle tissue of a living mouse breathing room air and carbogen (95% oxygen + 5% CO2), alternatively. The mean pO2 measured with this probe in muscle tissues was consistent with values reported previously using other methods. Overall, the probe shows very desirable characteristics for localized measurements of tissue oxygenation.  相似文献   

7.
Electron paramagnetic resonance imaging (EPRI) can be used to noninvasively and quantitatively obtain three-dimensional maps of tumor pO?. The paramagnetic tracer triarylmethyl (TAM), a substituted trityl radical moiety, is not toxic to animals and provides narrow isotropic spectra, which is ideal for in vivo EPR imaging experiments. From the oxygen-induced spectral broadening of TAM, pO? maps can be derived using EPRI. The instrumentation consists of an EPRI spectrometer and 7T magnetic resonance imaging (MRI) system both operating at a common radiofrequency of 300 MHz. Anatomic images obtained by MRI can be overlaid with pO? maps obtained from EPRI. With imaging times of less than 3 min, it was possible to monitor the dynamics of oxygen changes in tumor and distinguish chronically hypoxic regions from acutely hypoxic regions. In this article, the principles of pO? imaging with EPR and some relevant examples of tumor imaging are reviewed.  相似文献   

8.
Acute nodularin-induced hepatotoxicity was assessed in vivo, in rats using magnetic resonance (MR) techniques, including MR imaging (MRI), MR spectroscopy (MRS), and electron paramagnetic resonance (EPR) oximetry. Nodularin is a cyclic hepatotoxin isolated from the cyanobacterium Nodularia spumigena. Three hours following the intraperitoneal (i.p.) administration of nodularin (LD50), a region of 'damage', characterized by an increase in signal intensity, was observed proximal to the porta hepatis (PH) region in T2-weighted MR images of rat liver. Image analysis of these regions of apparent 'damage' indicated a statistically significant increase in signal intensity around the PH region following nodularin administration, in comparison with controls and regions peripheral to the PH region. An increase in signal intensity was also observed proximal to the PH region in water chemical shift selective images (CSSI) of nodularin-treated rat livers, indicating that the increased signal observed by MRI is an oedematous response to the toxin. Microscopic assessment (histology and electron microscopy) and serum liver enzyme function tests (aminotransferase (ALT) and aspartate ALT (AST)) confirmed the nodularin-induced tissue injury observed by MRI. In vivo and in vitro MRS was used to detect alterations in metabolites, such as lipids, Glu+Gln, and choline, during the hepatotoxic response (2-3 h post-exposure). Biochemical assessment of perchloric acid extracts of nodularin-treated rat livers were used to confirm the MRS results. In vivo EPR oximetry was used to monitor decreasing hepatic pO2 (approximately 2-fold from controls) 2-3 h following nodularin exposure. In vivo MR techniques (MRI, MRS and EPR oximetry) are able to highlight effects that may not have been evident in single end point studies, and are ideal methods to follow tissue injury progression in longitudinally, increasing the power of a study through repeated measures, and decreasing the number of animals to perform a similar study using histological or biochemical techniques.  相似文献   

9.
We describe a technique that utilizes electron paramagnetic resonance (EPR) to measure NO(*) and pO(2) directly, and non-invasively, from tissue in vivo. Diethyldithiocarbamate (DETC) was injected with iron so as to complex with NO(*) in the tissue. Gloxy (an oxygen-sensitive, paramagnetic material) was also implanted into the tissue of interest (brain or liver). Because the signals arising from gloxy and NO-Fe-(DETC)(2) did not overlap, they could be monitored and measured simultaneously in vivo. The gloxy was not responsive to NO(*) and/or DETC. As model systems we either injected SNP (an NO(*) donor) into animals and monitored NO(*) and pO(2) simultaneously from brain, or endotoxin (lipopolysaccharide; LPS) was injected in order to induce a septic episode and NO(*) and pO(2) measured from liver. We found a close correlation between levels of SNP-derived NO(*) and brain pO(2) in vivo. During sepsis, liver pO(2) decreased dramatically at 300-360 min after endotoxin injection, and this coincided with decreases in mean arterial blood pressure and increased tissue NO(*) detected. These studies demonstrate the potential usefulness of this technique for making direct in vivo measurements of NO(*) and pO(2) simultaneously from tissue.  相似文献   

10.
The development of an injectable probe formulation, consisting of perchlorotriphenylmethyl triester radical dissolved in hexafluorobenzene, for in vivo oximetry and imaging of oxygen concentration in tissues using electron paramagnetic resonance (EPR) imaging is reported. The probe was evaluated for its oxygen sensitivity, biostability, and distribution in a radiation-induced fibrosarcoma tumor transplanted into C3H mice. Some of the favorable features of the probe are: a single narrow EPR peak (anoxic linewidth, 41 microT), high solubility in hexafluorobenzene (>12 mM), large linewidth sensitivity to molecular oxygen ( approximately 1.8 microT/mmHg), good stability in tumor tissue (half-life: 3.3 h), absence of spin-spin broadening (up to 12 mM), and lack of power saturation effects (up to 200 mW). Three-dimensional spatial and spectral-spatial (spectroscopic) EPR imaging measurements were used to visualize the distribution of the probe, as well as to obtain spatially resolved pO(2) information in the mice tumor subjected to normoxic and hyperoxic treatments. The new probe should enable unique opportunities for measurement of the oxygen concentration in tumors using EPR methods.  相似文献   

11.
Electron paramagnetic resonance (EPR) oximetry is a powerful technology that allows the monitoring of oxygenation in tissues. The measurement of tissue oxygenation can be achieved using lithium phthalocyanine (LiPc) crystals as oxygen reporters. In order to have biocompatibility for the sensing system and to assure long-term stability in the responsiveness of the system, we developed films of Teflon AF 2400 with embedded LiPc crystals. These systems can be used as retrievable inserts or parts of an implantable resonator or catheter. Atomic force microscopy studies revealed that the surface of the films was regular and planar. The response to oxygen of the sensor (EPR linewidth as a function of pO(2)) remained unchanged after implantation in mice, and was not affected by sterilization or irradiation. The use of resonators, holding LiPc embedded in Teflon AF 2400, implanted in the gastrocnemius muscle of rabbits allowed the monitoring of oxygen during several weeks. Several assays also demonstrated the biocompatibility of the system: (1) no hemolytic effect was noted; (2) no toxicity was found using the systemic injection test of extracts; (3) histological analysis in rabbit muscle in which the films were implanted for 1 week or 3 months was similar to standard polyethylene biocompatible devices. These advanced oxygen sensors are promising tools for future pre-clinical and clinical developments of EPR oximetry. These developments can be applied for other applications of biosensors where there is a need for oxygen permeable membranes.  相似文献   

12.
The presence of oxygen-deficient tumor cells is a critical issue in cancer therapy. To identify tumor hypoxia, tissue partial oxygen pressure (pO2) can be measured directly. The OxyLite system allows determination of pO2 in tumors and permits continuous measurements of pO2 at a fixed point. In this study, this system was used to continuously measure pO2 in R3327-AT tumors in animals anesthetized with isoflurane. In addition, continuous pO2 measurement was performed in the muscle in non-tumor-bearing animals. In animals breathing isoflurane balanced by air, tumor pO2 at fixed positions decreased rapidly within 1-2 min of probe positioning but remained stable thereafter. In animals breathing isoflurane balanced by pure oxygen, tumor pO2 was higher and remained high. We also measured pO2 values at multiple positions in R3327-AT tumors of various sizes, with anesthetized animals breathing either air or pure oxygen. Our data showed that the frequency of pO2 measurements below 2.5 or 5.0 mmHg was significantly higher in animals breathing air than in animals breathing pure oxygen. Measurements in different-sized tumors showed that the mean pO2 value decreased as tumor volume increased, with the largest change occurring between tumor volumes of 100 and 200 mm3. Our data demonstrate that the OxyLite system, when used with isoflurane anesthesia, is a valuable tool in the study of tumor hypoxia.  相似文献   

13.
The effects of the antibacterial peptide PR-39 on nitric oxide (NO) and liver oxygenation (pO(2)) in a mouse model of endotoxaemia have been explored. In vivo electron paramagnetic resonance (EPR) spectroscopy was used to make direct measurements of liver NO and pO(2). Measurements of pO(2) were made at two different anatomical locations within hepatic tissue to assess effects on blood supply (hence oxygen supply) and lobule oxygenation; selectively from the liver sinusoids or an average pO(2) across the liver lobule. PR-39 induced elevated levels of liver NO at 6 h following injection of lipopolysaccharide (LPS) as a result of increased iNOS expression in liver, but had no effect on eNOS or circulatory NO metabolites. Sinusoidal oxygenation was preserved, and pO(2) across the hepatic tissue bed improved with PR-39 treatment. We propose that the beneficial effects of PR-39 on liver in this septic model were mediated by increased levels of local NO and preservation of oxygen supply to the liver sinusoids.  相似文献   

14.
Electron paramagnetic resonance (EPR) spectroscopy can be applied to measure oxygen concentrations in cells and tissues. Oxygen is paramagnetic, and thus it interacts with a free radical label resulting in a broadening of the observed linewidth. Recently we have developed instrumentation in order to enable the performance of EPR spectroscopy and EPR oximetry in the intact beating heart. This spectrometer consists of 1–2-GHz microwave bridge with the source locked to the resonant frequency of a specially designed lumped circuit resonator. This technique is applied to measure the kinetics of the uptake and clearance of different free radical labels. It is demonstrated that this technique can be used to noninvasively measure tissue oxygen concentration. In addition, rapid scan EPR measurements can be performed enabling gated millisecond measurements of oxygen concentrations to be performed over the cardiac cycle. Thus, low-frequency EPR spectroscopy offers great promise in the study of tissue oxygen concentrations and the role of oxygen in metabolic control.  相似文献   

15.
The efficacy of radiation treatment depends upon local oxygen concentration. We postulated that the variability in responsiveness of tumor xenografts to a fixed dose of radioimmunotherapy might be related to the tumor pO2 at the time that radioimmunotherapy was administered. We evaluated the growth of xenografts of CALU-3 tumors, a non-small cell lung carcinoma, in response to an 8.9-MBq dose of 131I-RS-7-anti-EGP-1 and correlated tumor growth rate with initial tumor pO2 measured by EPR oximetry. The greatest growth delay in response to radioimmunotherapy had the highest initial pO2, and the fastest-growing tumors had the lowest initial pO2. We then determined the dynamic effect of radioimmunotherapy on tumor pO2 by serial measurements of pO2 for 35 days after radioimmunotherapy. This information could be important for ascertaining the likelihood that a tumor will respond to additional doses as part of a multiple dose scheme. Serial tumor pO2 measurements may help identify a window of opportunity when the surviving tumor regions will be responsive to a second round of radioimmunotherapy or a second therapeutic modality such as chemotherapy or an anti-vascular agent. After radioimmunotherapy, there was an increase in tumor pO2 followed by a decrease below initial levels in most mice. Thus defined times may exist when a tumor is more or less radiosensitive after radioimmunotherapy.  相似文献   

16.
The oxygen consumption rate of tumor cells affects tumor oxygenation and response to therapies. Highly sensitive methods for determining cellular oxygen consumption are, therefore, needed to identify treatments that can modulate this parameter. We compared the performances of three different methods for measuring cellular oxygen consumption: electron paramagnetic resonance (EPR) oximetry, the Clark electrode, and the MitoXpress fluorescent assay. To compare the assays, we used K562 cells in the presence of rotenone and hydrocortisone, compounds that are known to inhibit the mitochondrial electron transport chain to different extents. The EPR method was the only one that could identify both rotenone and hydrocortisone as inhibitors of tumor cell oxygen consumption. The Clark electrode and the fluorescence assay demonstrated a significant decrease in cellular oxygen consumption after administration of the most potent inhibitor (rotenone) but failed to show any significant effect of hydrocortisone. EPR oximetry is, therefore, the most sensitive method for identifying inhibitors of oxygen consumption on cell assays, whereas the Clark electrode offers the unique opportunity to add external compounds during experiments and still shows great sensitivity in studying enzyme and chemical reactions that consume oxygen (non-cell assays). Finally, the MitoXpress fluorescent assay has the advantage of a high-sample throughput and low bulk requirements but at the cost of a lower sensitivity.  相似文献   

17.

Background

Paclitaxel (PTX) is a potent anti-cancer chemotherapeutic agent and is widely used in the treatments of solid tumors, particularly of the breast and ovaries. An effective and safe micellar formulation of PTX was used to administer higher doses of PTX than Taxol® (the current commercialized drug). We hypothesize that PTX-loaded micelles (M-PTX) may enhance tumor radiosensitivity by increasing the tumor oxygenation (pO2). Our goals were (i) to evaluate the contribution of the “oxygen effect” to the radiosensitizing effect of PTX; (ii) to demonstrate the therapeutic relevance of the combination of M-PTX and irradiation and (iii) to investigate the underlying mechanisms of the observed oxygen effect.

Methodology and Principal Findings

We used (PEG-p-(CL-co-TMC)) polymeric micelles to solubilize PTX. pO2 was measured on TLT tumor-bearing mice treated with M-PTX (80 mg/kg) using electron paramagnetic resonance (EPR) oximetry. The regrowth delay following 10 Gy irradiation 24 h after M-PTX treatment was measured. The tumor perfusion was assessed by the patent blue staining. The oxygen consumption rate and the apoptosis were evaluated by EPR oximetry and the TUNEL assay, respectively. EPR oximetry experiments showed that M-PTX dramatically increases the pO2 24 h post treatment. Regrowth delay assays demonstrated a synergy between M-PTX and irradiation. M-PTX increased the tumor blood flow while cells treated with M-PTX consumed less oxygen and presented more apoptosis.

Conclusions

M-PTX improved the tumor oxygenation which leads to synergy between this treatment and irradiation. This increased pO2 can be explained both by an increased blood flow and an inhibition of O2 consumption.  相似文献   

18.
We investigated the vocalizations produced by adult pine voles during various social interactions by presenting an experimental animal with either an anesthetized or awake (unanesthetized) conspecific. Ultrasonic vocalizations (USVs) occurred frequently during tests in which an awake male was present, but were rarely detected in tests involving only awake females, or when a female was presented with an anesthetized conspecific. Higher rates of USVs were produced when males were tested with a familiar female than when tested with an unfamiliar male or female. Equivalent rates were produced when males were presented with either anesthetized or awake animals, but female-soiled bedding failed to elicit USVs from males. Sonic vocalizations (SVs) were produced by both sexes and were associated with aggressive behavior, but occurred only in tests between awake, unfamiliar animals. Castration greatly reduced and testosterone therapy restored USVs emitted by males in response to anesthetized conspecifics. Our results suggest that (i) USVs are emitted predominantly by males; (ii) familiarity enhances USV response; (iii) SVs are produced during aggressive interactions; and (iv) androgens regulate the production of USVs by males. Possible roles for pine vole vocalizations are discussed.  相似文献   

19.
Szeto HH  Soong Y  Wu D  Olariu N  Kett A  Kim H  Clapp JF 《Peptides》1999,20(1):101-105
We compared the effects of three micro-(DAMGO, DALDA, TNPO) and three delta-(DPDPE, DELT, SNC-80) opioid agonists on arterial blood gas after IV administration in awake sheep. None of the mu agonists altered pO2, pCO2 or pH. All three mu agonists decreased pO2 increased pCO2 and decreased pO2, and this effect was not sensitive to naloxone or TIPPpsi, a delta-antagonist, suggesting that it is not mediated by beta-opioid receptors. When administered to pregnant animals, there were significant changes in fetal pCO2 and pH. It may be possible to develop delta-selective opioid agonists which do not produce respiratory depression.  相似文献   

20.
The question whether decapitation is a humane method of euthanasia in awake animals is being debated. To gather arguments in this debate, obsolete rats were decapitated while recording the EEG, both of awake rats and of anesthetized rats. Following decapitation a fast and global loss of power of the EEG was observed; the power in the 13-100 Hz frequency band, expressing cognitive activity, decreased according to an exponential decay function to half the initial value within 4 seconds. Whereas the pre-decapitation EEG of the anesthetized animals showed a burst suppression pattern quite different from the awake animals, the power in the postdecapitation EEG did not differ between the two groups. This might indicate that either the power of the EEG does not correlate well with consciousness or that consciousness is briefly regained in the anesthetized group after decapitation. Remarkably, after 50 seconds (awake group) or 80 seconds (anesthetized group) following decapitation, a high amplitude slow wave was observed. The EEG before this wave had more power than the signal after the wave. This wave might be due to a simultaneous massive loss of membrane potentials of the neurons. Still functioning ion channels, which keep the membrane potential intact before the wave, might explain the observed power difference. Two conclusions were drawn from this experiment. It is likely that consciousness vanishes within seconds after decapitation, implying that decapitation is a quick and not an inhumane method of euthanasia. It seems that the massive wave which can be recorded approximately one minute after decapitation reflects the ultimate border between life and death. This observation might have implications in the discussions on the appropriate time for organ donation.  相似文献   