首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rapid, quantitative detection of tumor markers with high sensitivity and specificity is critical to clinical diagnosis and treatment of cancer. We describe here a novel portable fluorescent biosensor that integrates quantum dot (QD) with an immunochromatography test strip (ICTS) and a home-made test strip reader for detection of tumor markers in human serum. Alpha fetoprotein (AFP), which is valuable for diagnosis of primary hepatic carcinoma, is used as a model tumor marker to demonstrate the performance of the proposed immunosensor. The principle of this sensor is on the basis of a sandwich immunoreaction that was performed on an ICTS. The fluorescence intensity of captured QD labels on the test line and control line served as signals was determined by the home-made test strip reader. The strong luminescence and robust photostability of QDs combined with the promising advantages of an ICTS and sensitive detection with the test strip reader result in good performance. Under optimal conditions, this biosensor is capable of detecting as low as 1 ng/mL AFP standard analyte in 10 min with only 50 μL sample volume. Furthermore, 1000 clinical human serum samples were tested by both the QD-based ICTS and a commercial electrochemiluminescence immunoassay AFP kit simultaneously to estimate the sensitivity, specificity and concordance of the assays. Results showed high consistency except for 24 false positive cases (false positive rate 3.92%) and 17 false negative cases (false negative rate 4.38%); the error rate was 4.10% in all. This demonstrates that the QD-based ICTS is capable of rapid, sensitive, and quantitative detection of AFP and shows a great promise for point-of-care testing of other tumor markers.  相似文献   

2.
A polymer nanostructured Fabry–Perot interferometer (FPI) based biosensor is reported. Different from a conventional FPI, the nanostructured FPI has a layer of Au-coated nanopores inside its cavity. The Au-coated nanostructure layer offers significant enhancement of optical transducing signals due to the localized surface plasmon resonance effect and also due to the significantly increased sensing surface area, which is up to at least two orders of magnitude larger than that of a conventional FPI-based biosensor. Using this technical platform, the immobilization of captures proteins (protein A) on the nanostructure layer and their binding with immunoglobulin G (IgG) has been monitored in real time, resulting in the shift of the interference fringes of the optical transducing signals. Current results show that the limit-of-detection of the biosensor should be lower than 10 pg/mL for IgG-protein A binding.  相似文献   

3.
C-Reactive Protein (CRP) is an acute phase reactant routinely used as a biomarker to assess either infection or inflammatory processes such as autoimmune diseases. CRP also has demonstrated utility as a predictive marker of future risk of cardiovascular disease. A new method of immunoassay for the detection of C-Reactive Protein has been developed using Resonant Acoustic Profiling™ (RAP™) with comparable sensitivity to a high sensitivity CRP ELISA (hsCRP) but with considerable time efficiency (12 minutes turnaround time to result). In one method, standard solutions of CRP (0 to 231 ng/mL) or diluted spiked horse serum sample are injected through two sensor channels of a RAP™ biosensor. One contains a surface with sheep antibody to CRP, the other a control surface containing purified Sheep IgG. At the end of a 5-minute injection the initial rate of change in resonant frequency was proportional to CRP concentration. The initial rates of a second sandwich step of anti-CRP binding were also proportional to the sample CRP concentration and provided a more sensitive method for quantification of CRP. The lower limit of detection for the direct assay and the homogenous sandwich assay were both 20 ng/mL whereas for the direct sandwich assay the lower limit was 3 ng/mL. In a step towards a rapid clinical assay, diluted horse blood spiked with human CRP was passed over one sensor channel whilst a reference standard solution at the borderline cardiovascular risk level was passed over the other. A semi-quantities ratio was thus obtained indicative of sample CRP status. Overall, the present study revealed that CRP concentrations in serum that might be expected in both normal and pathological conditions can be detected in a time-efficient, label-free immunoassay with RAP™ detection technology with determined CRP concentrations in close agreement with those determined using a commercially available high sensitivity ELISA.  相似文献   

4.
Gold nanoshells (GNSs) were self-assembled on the surface of transparent glasses modified with 3-aminopropyltrimethoxysilane (APTES) to form GNS self-assembled monolayers (SAMs). Because the localized surface plasmon resonance (LSPR) of GNSs can be controlled in the near-infrared (NIR) region of the spectrum, where the optical transmission through tissue and whole blood is optimal, GNSs would be used as an effective signal transduction in whole blood. Accordingly, after modified with cystamine and biotin-NHS (N-hydroxy succinimide), GNS SAMs were used as a novel optical biosensor for real-time detection of streptavidin-biotin interactions in diluted human whole blood within short assay time, without any sample purification/separation. An UV-vis-NIR spectrophotometer was used to monitor the absorbance changes at 730 nm as a function of time for different concentrations of streptavidin in 20% whole blood, and the results showed that the biosensor displayed low detection limit of approximately 3 microg/mL and wide dynamic range of approximately 3-50 microg/mL. This approach provides an opportunity to construct LSPR biosensor for protein sensing and cellular analysis in diluted whole blood.  相似文献   

5.
A sensitive and label-free analytical approach for the detection of porcine circovirus type 2 (PCV2) instead of PCV2 antibody in serum sample was systematically investigated in this research based on surface plasmon resonance (SPR) with an establishment of special molecular identification membrane. The experimental device for constructing the biosensing analyzer is composed of an integrated biosensor, a home-made microfluidic module, and an electrical control circuit incorporated with a photoelectric converter. In order to detect the PCV2 using the surface plasmon resonance immunoassay, the mercaptopropionic acid has been used to bind the Au film in advance through the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. PCV2 antibodies were bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. For the purpose of evaluating the performance of this approach, the known concentrations of PCV2 Cap protein of 10 µg/mL, 7.5 µg/mL, 5 µg/mL, 2.5 µg/mL, 1 µg/mL, and 0.5 µg/mL were prepared by diluting with PBS successively and then the delta response units (ΔRUs) were measured individually. Using the data collected from the linear CCD array, the ΔRUs gave a linear response over a wide concentration range of standard known concentrations of PCV2 Cap protein with the R-Squared value of 0.99625. The theoretical limit of detection was calculated to be 0.04 µg/mL for the surface plasmon resonance biosensing approach. Correspondingly, the recovery rate ranged from 81.0% to 89.3% was obtained. In contrast to the PCV2 detection kits, this surface plasmon resonance biosensing system was validated through linearity, precision and recovery, which demonstrated that the surface plasmon resonance immunoassay is reliable and robust. It was concluded that the detection method which is associated with biomembrane properties is expected to contribute much to determine the PCV2 in sample solutions instead of PCV2 antibody in serum samples quantitatively.  相似文献   

6.
血清多肽是癌症诊断信息的重要来源,建立、优化了检测多肽标志物的直接ELISA法,并应用于肝癌血清中的多肽标志物的检测。制备及纯化针对多肽标志物Pep5的单克隆抗体并进行辣根过氧化物酶标记,用其建立检测相应抗原的直接ELISA法。方法线性范围为1.5-20 ng/mL,检测限为1.24 ng/mL;标准品批内及批间CV分别小于3.66%及4.89%,血清样本批内及批间CV分别小于11.69%及18.18%;线性范围内(9、12和15 ng/mL)的回收率分别为98.98%,99.61%和101.58%。应用该方法共检测160例正常血清、104例肝硬化及156例肝癌患者血清,正常组与肝硬化组及肝癌组间差异显著(P<0.001),Pep5诊断肝癌的敏感性和特异性分别为80.8%和96.2%。同时检测94例HCC血清中的AFP和Pep5,AFP检出率为63.8%,Pep5检出率为90.4%,AFP联合Pep5检测时,能将HCC的检出率提高至94.7%。  相似文献   

7.
In this paper the determination of Ochratoxin A (OTA) in low volumes of human blood serum by enzyme-linked immunosorbent assay (ELISA) is compared with an appropriate capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) method. In order to use ELISA for high-throughput analysis in epidemiological studies no sample cleanup was performed. Both methods showed a limit of detection (LOD) of 0.5 ng/mL. Comparing the precisions of both methods, the data show that the quantified concentrations in ELISA are higher than the corresponding concentrations in the CE-LIF method. Using a matrix calibration curve instead of a standard calibration curve the reproducibilities of both methods are comparable. No additional matrix effect could be observed by adding phenylalanine as probable matrix compound to the serum.  相似文献   

8.
A new approach toward the development of advanced immunosensors based on chemically functionalized core-shell-shell magnetic nanocomposite particles, and the preparation, characteristics, and measurement of relevant properties of the immunosensor useful for the detection of alpha-1-fetoprotein (AFP) in clinical immunoassays. The core-shell NiFe2O4/3-aminopropyltriethoxysilance (APTES) (NiFe2O4@APTES) was initially prepared by covalent conjugation, then gold nanoparticles were adsorbed onto the surface of NiFe2O4@APTES, and then anti-AFP molecules were conjugated on the gold nanoparticles. The core-shell-shell nanocomposite particles not only had the properties of magnetic nanoparticles, but also provided a good biocompatibility for the immobilization of biomolecules. The core-shell-shell nanostructure present good magnetic properties to facilitate and modulate the way it was integrated into a carbon paste. The analytical performance of the immunosensor was investigated by using an electrochemical method. Under optimal conditions, the resulting composite presents good electrochemical response for the detection of AFP, and exhibits wide linear range from 0.9 to 110 ng/mL AFP with a detection limit of 0.5 ng/mL. Moreover, the proposed immunosensors were used to analyze AFP in human serum specimens. Analytical results, obtained for the clinical serum specimen by the developed immunosensor, were in accordance with those assayed by the standard ELISA. Importantly, the proposed immunoassay system could be further developed for the immobilization of other antigens or biocompounds.  相似文献   

9.
We have developed a new method for highly selective determination of the ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) concentration using a surface plasmon resonance imaging (SPRI) technique and two different biosensors. UCH-L1 was captured from a solution by immobilized specific rabbit monoclonal antibody or specific LDN-57444 inhibitor due to formation of receptor–UCH-L1 complex on the biosensor surface. The analytically useful dynamic response range of both biosensors is between 0.1 and 2.5 ng/ml. The detection limit is 0.06 ng/ml for the biosensor with antibody and 0.08 ng/ml for the biosensor with inhibitor. Biosensors based on both antibody and inhibitor were found to be suitable for quantitative determination of the UCH-L1 and exhibit good tolerance to the potential interferents. Both biosensors gave comparable results in the range of 0 to 0.20 ng/ml for plasma samples and 0.30 to 0.49 ng/ml for cerebrospinal fluid samples. To validate the new methods, comparative determination of UCH-L1 by the commercial enzyme-linked immunosorbent assay (ELISA) kit was performed. In general, in terms of UCH-L1 concentration, a good correlation between SPRI and ELISA was found. The developed biosensors can be used successfully for the determination of UCH-L1 in body fluids.  相似文献   

10.
This paper describes the direct label-free detection of antibodies against the Epstein-Barr virus (anti-EBNA) using a surface plasmon resonance (SPR) biosensor. The antibody detection was performed using the immunoreaction between anti-EBNA and a respective synthetic peptide (EBNA-1), which was conjugated with bovine serum albumin (BSA-EBNA) and immobilized on the sensor surface. Three immobilization chemistries for the attachment of BSA-EBNA were investigated to optimize ligand density and minimize loss of EBNA-1 immunoreactivity. The developed SPR biosensor functionalized with the optimal immobilization method was calibrated and characterized in terms of detection limit, reproducibility, regenerability and storability. It was demonstrated that the sensor is capable of detecting concentrations of anti-EBNA as low as 0.2 ng/ml (approximately 1 pM) both in buffer and 1% human serum and can be stored and regenerated for repeated use.  相似文献   

11.
In order to explore the clinical application of the nanobiosensor based on localized surface plasmon resonance (LSPR), we used our LSPR biosensor to detect the microalbuminuria in this work. The sliver nanoparticles were fabricated by using nanosphere lithography. The anti-human albumin antibody was immobilized on the sensor surface by amine coupling method. The different concentrations of commercial albumin and albumin in urine samples from three mild preeclampsia patients were determined according to the peak of LSPR extinction spectra. Under optimum conditions, our results showed that the biosensor displayed a detection limit of 1 ng/ml and wide dynamic range of 1 ng/ml to 1 μg/ml. Furthermore, the microalbuminuria of three patients was determined by our biosensor within a short assay time, without sample purification. This biosensor proposed herein is easy to prepare and could be used for low-cost, rapid, label-free, and sensitive screening of the microalbuminuria. This approach provides a promising platform for developing clinical diagnostic applications.  相似文献   

12.
A fiber optic surface plasmon resonance (SPR) biosensor for detection of Staphylococcal enterotoxin B (SEB) is reported. The sensor is based on spectral interrogation of surface plasmons in a miniature sensing element based on a side-polished single-mode optical fiber with a thin metal overlayer. For specific detection of SEB, the SPR sensor is functionalized with a covalently crosslinked double-layer of antibodies against SEB. The SPR biosensor is demonstrated to be able to detect ng/ml concentrations of SEB in less than 10 min.  相似文献   

13.
At the Institute of Sera and Vaccines, Praha, was invented and tested on clinical samples a kit for detection and quantification of alpha 1 fetoprotein in human serum. It is a heterogeneous EIA on the "sandwich" principle. Rabbit antibody to alpha 1 fetoprotein (further AFP) was used for coating the solid surface and goat horse-radish peroxidase labelled antibody to AFP was used as the tracer. Microtitration plate of Czechoslovak manufacture (KOH-I-NOOR, Dalecín) type P with 96 wells was used as the solid phase. The range of an approximately linear part of the calibration curve was intentionally chosen between 10 and 400 ng/ml, since in this way it fills the detection gap in AFP determination between 10 and 200 ng/ml, which is, on the one hand, a physiological value of AFP in human serum and, on the other hand, the bottom limit of sensitivity of counter immunoelectrophoresis (CIEP). Attention was devoted both to reproducibility of the method, i.e. results of intra- and interassays, and comparability with other foreign ELISA Kits. According to the correlation analysis, the kit was ascertained to be very well comparable with kits of foreign provenance. The coefficient of variation (CV) for the interassays varied between 11 and 16% and for intraassays it equalled 15%.  相似文献   

14.
The detection performance of conventional surface plasmon resonance (SPR) biosensors is limited to a 1 pg/mm(2) surface coverage of biomolecules, and consequently, such sensors struggle to detect the interaction of small molecules in low concentrations. The present study is attempted to propose the use of a novel SPR biosensor with Au nanoclusters embedded in a dielectric film to achieve a 10-fold improvement in the resolution performance. A co-sputtering method utilizing a multi-target sputtering system is used to fabricate the present dielectric films (SiO(2)) with embedded Au nanoclusters. It is shown that the sensitivity of the developed SPR biosensor can be improved by adjusting the size and volume fraction of the embedded Au nanoclusters in order to control the surface plasmon effect. The present gas detection and DNA hybridization experimental results confirm that the proposed Au nanocluster-enhanced SPR biosensor provides the potential to achieve an ultrahigh-resolution detection performance of approximately 0.1 pg/mm(2) surface coverage of biomolecules.  相似文献   

15.
The relatively high detection limit of the Enzyme-linked immunosorbent assay (ELISA) prevents its application for detection of low concentrations of antigens. To increase the sensitivity for detection of HIV-1 p24 antigen, we developed a highly sensitive nuclease-linked fluorescence oligonucleotide assay (NLFOA). Two major improvements were incorporated in NLFOA to amplify antibody-antigen interaction signals and reduce the signal/noise ratio; a large number of nuclease molecules coupled to the gold nanoparticle/streptavidin complex and fluorescent signals generated from fluorescent-labeled oligonucleotides by the nuclease. The detection limit of p24 by NLFOA was 1 pg/mL, which was 10-fold more sensitive than the conventional ELISA (10 pg/mL). The specificity was 100% and the coefficient of variation (CV) was 7.8% at low p24 concentration (1.5 pg/mL) with various concentrations of spiked p24 in HIV-1 negative sera. Thus, NLFOA is highly sensitive, specific, reproducible and user-friendly. The more sensitive detection of low p24 concentrations in HIV-1-infected individuals by NLFOA could allow detection of HIV-1 infections that are missed by the conventional ELISA at the window period during acute infection to further reduce the risk for HIV-1 infection due to the undetected HIV-1 in the blood products. Moreover, NLFOA can be easily applied to more sensitive detection of other antigens.  相似文献   

16.
In this study, we attempted to develop a surface plasmon resonance (SPR)-based immunoassay sensor to detect alpha-fetoprotein (AFP) in human plasma at the nanogram level, as is required for clinical diagnosis of hepatocellular tumors. A self-assembled monolayer (SAM) surface of tri(ethylene glycol) (TEG) and carboxyl group-terminated hexa(ethylene glycol) (HEG) was employed to suppress the nonspecific adsorption of plasma components onto the sensor surface. AFP was detected by a sandwich-type immunoassay using two kinds of antibodies, primary and secondary, in this system. The SPR signal shift was further enhanced by applying an antibody (polyclonal) against the second antibody. With this method, the SPR signals were highly intensified, and so nanogram levels (ng/ml) of AFP could be easily detected with a high signal/noise ratio, as is necessary for clinical diagnosis. It is expected that our SPR-based immunoassay method can also be applicable to the detection of several other tumor markers that are present in low concentrations in human blood.  相似文献   

17.
In this article, a conspicuously simple and highly sensitive amperometric immunosensor based on the sequential electrodeposition of Prussian blue (PB) and gold nanoparticles (GNPs) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrode (GCE) surface is proposed for the detection of α-fetoprotein (AFP). By comparison with PB, the MWCNT/PB composite film had been proven to show much better electrochemical stability and a larger response current. The electrodeposited GNP film can be used not only to immobilize biomolecules but also to avoid the leakage of PB and to prevent shedding of MWCNT/PB composite film from the electrode surface. The performance and factors influencing the performance of the immunosensor were investigated. Under optimal experimental conditions, the proposed immunosensor for AFP was observed with an ultralow limit of detection (LOD) equal to 3 pg/ml (at 3δ), and the linear working range spanned the concentrations of AFP from 0.01 to 300 ng/ml. Moreover, the immunosensor, as well as a commercially available kit, was examined for use in the determination of AFP in real human serum specimens. More significant, the assay mentioned here is simpler than the traditional enzyme-linked immunosorbent assay (ELISA), and an excellent correlation of levels of AFP measured was obtained, indicating that the developed immunoassay could be a promising alternative approach for detection of AFP and other tumor markers in the clinical diagnosis.  相似文献   

18.
Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) combines enhanced field platform and fluorescence detection. Its advantages are the strong intensity of the electromagnetic field and the high signal/noise (S/N) ratio due to the localized evanescent field at the water/metal interface. However, the energy transfer from the fluorophore to the metal surface diminishes the fluorescence intensity, and this reduces the sensitivity. In this study, we tested whether polystyrene (PSt) could act as a dielectric layer to suppress the energy transfer from the fluorophore to the metal surface. We hypothesized that this would improve the sensitivity of SPFS-based immunoassays. We used α-fetoprotein (AFP) as a model tumor biomarker in the sandwich-type immunoassay. We determined the relationship between fluorescent signal intensity and PSt layer thickness and compared this to theoretical predictions. We found that the fluorescence signal increased by optimally controlling the thickness of the PSt layer. Our results indicated that the SPFS-based immunoassay is a promising clinical diagnostic tool for quantitatively determining the concentrations of low-level biomarkers in blood samples.  相似文献   

19.
A suite of biosensors for rapid detection of inducible nitric oxide synthase (iNOS) is described. First, a metal-enhanced electrochemical detection (MED) sensor, which relied on the redox properties of a silver monolayer, was developed. The linear detection range was between 8.64 × 10−2 and 5.4 × 101 ng/ml with a detection limit of 1.69 × 10−4 ng/ml. This method was compared with surface plasmon resonance (SPR) biosensors in which polyclonal mouse anti-iNOS was covalently immobilized onto a gold surface using an iNOS antigen. The linear detection range recorded was between 3.37 × 101 and 5.4 × 10−2 ng/ml with a detection limit of 2 × 10−3 ng/ml. Finally, an ultrasensitive portable capillary (UPAC) fluorescence immunosensor, in which a mouse anti-iNOS antibody was covalently immobilized onto the inner surface of a capillary and a rabbit anti-iNOS antibody was employed as the secondary antibody, was developed. The resulting signals were found to be directly proportional to iNOS concentrations between 1.52 × 10−1 and 1.52 × 10−2 ng/ml with a detection limit of 1.05 × 10−3 ng/ml. These immunosensors exhibit low cross-reactivity toward potential interferents such as human serum albumin and ovalbumin. The SPR and UPAC biosensors were validated using simulated blood spiked with recombinant iNOS, resulting in recoveries of 85% and 88.5%, respectively. The research presented in this article could potentially provide new ways of detecting NO for diagnostic and biomarker purposes in medical research.  相似文献   

20.
This paper reports the application of differential phase surface plasmon resonance (SPR) imaging in two-dimensional (2D) protein biosensor arrays. Our phase imaging approach offers a distinct advantage over the conventional angular SPR technique in terms of utilization efficiency of optical sensor elements in the imaging device. In the angular approach, each biosensor site in the biosensor array requires a linear array of optical detector elements to locate the SPR angular dip. The maximum biosensor density that a two-dimensional imaging device can offer is a one-dimensional SPR biosensor array. On the other hand, the phase-sensitive SPR approach captures data in the time domain instead of the spatial domain. It is possible that each pixel in the captured interferogram represents one sensor site, thus offering high-density two-dimensional biosensor arrays. In addition, our differential phase approach improves detection resolution through removing common-mode disturbances. Experimental results demonstrate a system resolution of 8.8 x 10(-7)RIU (refractive index unit). Real-time monitoring of bovine serum albumin (BSA)/anti-BSA binding interactions at various concentration levels was achieved using a biosensor array. The detection limit was 0.77 microg/ml. The reported two-dimensional SPR biosensor array offers a real-time and non-labeling detection tool for high-throughput protein array analysis. It may find promising applications in protein therapeutics, drug screening and clinical diagnostics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号