首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Diagnosing and quantifying plant-parasitic nematodes is critical for efficient nematode management. Several studies have been performed intending to demonstrate nematode quantification via real-time quantitative PCR. However, most of the studies used dilution of DNA templates to make standard curves, while few studies used samples with different nematode numbers to make the standard curve, resulting in a high standard error. The objective of the present study was to develop a high quality standard curve using samples containing different numbers of the root-knot nematode Meloidogyne incognita and evaluate the results of real time qPCR with maxRatio analysis. The results showed that a high quality standard curve was obtained with different nematode numbers using specific primers and cycle threshold (Ct)-PCR (R(2)=0.9962, P<0.001, n=9). With the maxRatio analysis, the fractional cycle number (FCN)-PCR cycle curve and adjusted FCN (FCNadj)-PCR cycle curve had similar patterns as those of the Ct-PCR cycle curve. For quantification of nematodes in field soil samples, qPCR estimations with a FCNadj-PCR cycle standard curve was very close to microscope counting of second-stage juveniles (R(2)=0.9064, P<0.001, n=10), qPCR estimations with a FCN-PCR cycle standard curve was comparably good (R(2)=0.8509, P<0.001, n=10), and the biases with a Ct-PCR cycle standard curve were large (R(2)=0.7154, P<0.001, n=10). Moreover, we found that the concentration of Triton X-100 had less of an effect on FCN as compared to Ct, with delta FCN 0.52, and delta Ct 3.94 at 0.8% Triton. The present study suggests, that combined with maxRatio methods, real time qPCR could be a practical approach for quantifying M. incognita in field samples.  相似文献   

2.
3.
同步PCR是一种集生化、光电和计算机技术于一体的封闭式DNA扩增系统,采用荧光染料将扩增与检测过程结合在一起,实现了在PCR过程中在线显示PCR反应,通过检测荧光强度来绝对定量起始模板的拷贝数.该技术大大简化和加速了核酸分子的定量过程,不仅快速、灵敏、准确、重复性好,而且很容易计算出待测样品中核酸分子的绝对起始拷贝数.同微阵列等分子生物技术一起,同步PCR技术将会在功能基因解析和病害分子诊断等方面发挥重要作用.本综述除了介绍同步PCR技术的原理和应用外,还介绍了定量拟南芥Aux/IAA基因的转录水平的实验,并就同步PCR操作过程中的问题进行了讨论.  相似文献   

4.
Polymerase chain reaction (PCR) is a sensitive and rapid method for the diagnosis of canine Leishmania infection and can be performed on a variety of biological samples, including peripheral blood, lymph node, bone marrow and skin. Standard PCR requires electrophoretic analysis of the amplification products and is usually not suitable for quantification of the template DNA (unless competitor-based or other methods are developed), being of reduced usefulness when accurate monitoring of target DNA is required. Quantitative real-time PCR allows the continuous monitoring of the accumulation of PCR products during the amplification reaction. This allows the identification of the cycle of near-logarithmic PCR product generation (threshold cycle) and, by inference, the relative quantification of the template DNA present at the start of the reaction. Since the amplification product are monitored in "real-time" as they form cycle-by-cycle, no post-amplification handling is required. The absolute quantification is performed according either to an internal standard co-amplified with the sample DNA, or to an external standard curve obtained by parallel amplification of serial known concentrations of a reference DNA sequence. From the quantification of the template DNA, an estimation of the relative load of parasites in the different samples can be obtained. The advantages compared to standard and semi-quantitative PCR techniques are reduction of the assay's time and contamination risks, and improved sensitivity. As for standard PCR, the minimal components of the quantitative PCR reaction mixture are the DNA target of the amplification, an oligonucleotide primer pair flanking the target sequence, a suitable DNA polymerase, deoxynucleotides, buffer and salts. Different technologies have been set up for the monitoring of amplification products, generally based on the use of fluorescent probes. For instance, SYBR Green technology is a non-specific detection system based on a fluorescent dsDNA intercalator and it is applicable to all potential targets. TaqMan technology is more specific since performs the direct assessment of the amount of amplified DNA using a fluorescent probe specific for the target sequence flanked by the primer pair. This probe is an oligonucleotide labelled with a reporter dye (fluorescent) and a quencher (which absorbs the fluorescent signal generated by the reporter). The thermic protocol of amplification allows the binding of the fluorescent probe to the target sequence before the binding of the primers and the starting of the polymerization by Taq polymerase. During polymerization, 5'-3' exonuclease activity of Taq polymerase digests the probe and in this way the reporter dye is released from the probe and a fluorescent signal is detected. The intensity of the signal accumulates at the end of each cycle and is related to the amount of the amplification product. In recent years, quantitative PCR methods based either on SYBR Green or TaqMan technology have been set up for the quantification of Leishmania in mouse liver, mouse skin and human peripheral blood, targeting either single-copy chromosomal or multi-copy minicircle sequences with high sensitivity and reproducibility. In particular, real-time PCR seems to be a reliable, rapid and noninvasive method for the diagnosis and follow up of visceral leishmaniasis in humans. At present, the application of real-time PCR for research and clinical diagnosis of Leishmania infection in dogs is still foreseable. As for standard PCR, the high sensitivity of real-time PCR could allow the use of blood sampling that is less invasive and easily performed for monitoring the status of the dogs. The development of a real-time PCR assay for Leishmania infantum infection in dogs could support the standard and optimized serological and PCR methods currenly in use for the diagnosis and follow-up of canine leishmaniasis, and perhaps prediction of recurrences associated with tissue loads of residual pathogens after treatment. At this regard, a TaqMan Real Time PCR method developed for the quantification of Leishmania infantum minicircle DNA in peripheral blood of naturally infected dogs sampled before and at different time points after the beginning of a standard antileishmanial therapy will be illustrated.  相似文献   

5.
High-sensitivity quantitative PCR platform   总被引:1,自引:0,他引:1  
DeGraves FJ  Gao D  Kaltenboeck B 《BioTechniques》2003,34(1):106-10, 112-5
Real-time PCR methods have become widely used within the past few years. However, real-time PCR is rarely used to study chronic diseases with low pathogen loads, presumably because of insufficient sensitivity. In this report, we developed an integrated nucleic acid isolation and real-time PCR platform that vastly improved the sensitivity of the quantitative detection of the intracellular bacterium, Chlamydia spp., by fluorescence resonance energy transfer real-time PCR. Determinants of the overall detection sensitivity were analyzed by extracting nucleic acids from bovine milk specimens spiked with low amounts of chlamydial organisms. Nucleic acids were optimally preserved and recovered by collection in guanidinium stabilization buffer, binding to a matrix of glass fiber fleece, and elution in low volume. Step-down thermal cycling and an excess of hot-start Taq polymerase vastly improved the robustness and sensitivity of the real-time PCR while essentially maintaining 100% specificity. The amplification of Chlamydia 23S rRNA allowed for the differentiation of chlamydial species and was more robust at low target numbers than amplification of the omp1 gene. The best combined method detected single targets per a 100-microL specimen equivalent in a 5-microL real-time PCR input. In an initial application, this high-sensitivity real-time PCR platform demonstrated a high prevalence of chlamydial infection in cattle.  相似文献   

6.
Nucleic acid amplification and detection plays an increasingly important role in genetic analysis of clinical samples, medical diagnostics and drug discovery. We present a new quantitative PCR method that allows versatile and flexible nucleic acid target quantification. One of the PCR primers is modified by an oligonucleotide "tail" fluorescently labeled at the 5' end. An oligonucleotide complementary to this tail, carrying a 3'-quencher ("anti-primer"), is included in the PCR along with the two primers. Following primer extension, the reaction temperature is lowered such that the anti-primer hybridizes to and quenches the fluorescence of only the free primer and not the double-stranded PCR product, allowing real-time fluorescent quantification of the latter. This anti-primer-based quantitative real-time PCR (aQRT-PCR) allows simplex or multiplex quantification or single-nucleotide polymorphism genotyping in clinical samples of widely differing quality (e.g., fresh samples, formalin-fixed paraffin-embedded samples and plasma-circulating DNA) and provides a practical alternative to existing, more expensive approaches. The process of aQRT-PCR takes 1.5-2 h.  相似文献   

7.
The real-time polymerase chain reaction   总被引:20,自引:0,他引:20  
The scientific, medical, and diagnostic communities have been presented the most powerful tool for quantitative nucleic acids analysis: real-time PCR [Bustin, S.A., 2004. A-Z of Quantitative PCR. IUL Press, San Diego, CA]. This new technique is a refinement of the original Polymerase Chain Reaction (PCR) developed by Kary Mullis and coworkers in the mid 80:ies [Saiki, R.K., et al., 1985. Enzymatic amplification of beta-globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia, Science 230, 1350], for which Kary Mullis was awarded the 1993 year's Nobel prize in Chemistry. By PCR essentially any nucleic acid sequence present in a complex sample can be amplified in a cyclic process to generate a large number of identical copies that can readily be analyzed. This made it possible, for example, to manipulate DNA for cloning purposes, genetic engineering, and sequencing. But as an analytical technique the original PCR method had some serious limitations. By first amplifying the DNA sequence and then analyzing the product, quantification was exceedingly difficult since the PCR gave rise to essentially the same amount of product independently of the initial amount of DNA template molecules that were present. This limitation was resolved in 1992 by the development of real-time PCR by Higuchi et al. [Higuchi, R., Dollinger, G., Walsh, P.S., Griffith, R., 1992. Simultaneous amplification and detection of specific DNA-sequences. Bio-Technology 10(4), 413-417]. In real-time PCR the amount of product formed is monitored during the course of the reaction by monitoring the fluorescence of dyes or probes introduced into the reaction that is proportional to the amount of product formed, and the number of amplification cycles required to obtain a particular amount of DNA molecules is registered. Assuming a certain amplification efficiency, which typically is close to a doubling of the number of molecules per amplification cycle, it is possible to calculate the number of DNA molecules of the amplified sequence that were initially present in the sample. With the highly efficient detection chemistries, sensitive instrumentation, and optimized assays that are available today the number of DNA molecules of a particular sequence in a complex sample can be determined with unprecedented accuracy and sensitivity sufficient to detect a single molecule. Typical uses of real-time PCR include pathogen detection, gene expression analysis, single nucleotide polymorphism (SNP) analysis, analysis of chromosome aberrations, and most recently also protein detection by real-time immuno PCR.  相似文献   

8.
Single nucleotide polymorphisms (SNPs) are often determined using TaqMan real-time PCR assays (Applied Biosystems) and commercial software that assigns genotypes based on reporter probe signals at the end of amplification. Limitations to the large-scale application of this approach include the need for positive controls or operator intervention to set signal thresholds when one allele is rare. In the interest of optimizing real-time PCR genotyping, we developed an algorithm for automatic genotype calling based on the full course of real-time PCR data. Best cycle genotyping algorithm (BCGA), written in the open source language R, is based on the assumptions that classification depends on the time (cycle) of amplification and that it is possible to identify a best discriminating cycle for each SNP assay. The algorithm is unique in that it classifies samples according to the behavior of blanks (no DNA samples), which cluster with heterozygous samples. This method of classification eliminates the need for positive controls and permits accurate genotyping even in the absence of a genotype class, for example when one allele is rare. Here, we describe the algorithm and test its validity, compared to the standard end-point method and to DNA sequencing.  相似文献   

9.
A PCR primer bank for quantitative gene expression analysis   总被引:8,自引:0,他引:8       下载免费PDF全文
  相似文献   

10.
The optimal 6-carboxy-X-rhodamine (ROX) concentration, which is used as a passive reference dye for real-time quantitative polymerase chain reaction (PCR) with molecular beacon chemistry, was determined with the Mx4000 Multiplex Quantitative PCR System. Additionally, the effects of changing ROX concentrations on PCR reproducibility, Ct values, and efficiency were investigated with this system by using the PCR data obtained from amplification of the Escherichia coli shiga toxin 2 (stx2) gene and the Campylobacter jejuni luxS gene. This study indicated that different ROX concentrations influence many aspects of the real-time PCR reaction. ROX concentration variation could have consequences in the analysis of quantitative data and may lead to erroneous results. This study further indicated that the optimal ROX concentration is 60 nmol/L for real-time PCR, using molecular beacon chemistry for PCR assay of luxS and stx2 genes.  相似文献   

11.
We evaluated the robustness of loop-mediated isothermal amplification (LAMP) of DNA for bacterial diagnostic applications. Salmonella enterica serovar Typhi was used as the target organism and compared with a real-time quantitative PCR (qPCR) for testing assay performance and reproducibly, as well as the impact of pH and temperature stability. This isothermal amplification method appeared to be particularly robust across 2 pH units (7.3-9.3) and temperature values (57-67 °C). The detection limit was comparable to that observed using optimized home-brew qPCR assays. The specificity of the amplification reaction remained high even at temperatures markedly different from the optimal one. Exposing reagents to the ambient temperature during the preparation of the reaction mixture as well as prolonging times for preparing the amplification reaction did not yield false-positive results. LAMP remained sensitive and specific despite the addition of untreated biological fluids such as stool or urine that commonly inhibit PCR amplification. Whereas the detection of microorganisms from whole blood or a blood-culture medium typically requires extensive sample purification and removal of inhibitors, LAMP amplification remained more sensitive than conventional qPCR when omitting such preparatory steps. Our results demonstrate that LAMP is not only easy to use, but is also a very robust, innovative and powerful molecular diagnostic method for both industrialized and developing countries.  相似文献   

12.
Quantitative real-time PCR has revolutionized many aspects of genetic research, biomedical diagnostics and pathogen detection. Nevertheless, the full potential of this technology has yet to be realized, primarily due to the limitations of the threshold-based methodologies that are currently used for quantitative analysis. Prone to errors caused by variations in reaction preparation and amplification conditions, these approaches necessitate construction of standard curves for each target sequence, significantly limiting the development of high-throughput applications that demand substantive levels of reliability and automation. In this study, an alternative approach based upon fitting of fluorescence data to a four-parametric sigmoid function is shown to dramatically increase both the utility and reliability of quantitative real-time PCR. By mathematically modeling individual amplification reactions, quantification can be achieved without the use of standard curves and without prior knowledge of amplification efficiency. Combined with provision of quantitative scale via optical calibration, sigmoidal curve-fitting could confer the capability for fully automated quantification of nucleic acids with unparalleled accuracy and reliability.  相似文献   

13.
The current methods for the detection of pathogenic Yersinia enterocolitica bacteria in food are time consuming and inefficient. Therefore, we have developed and evaluated in-house a TaqMan probe-based real-time PCR method for the detection of this pathogen. The complete method comprises overnight enrichment, DNA extraction, and real-time PCR amplification. Also included in the method is an internal amplification control. The selected primer-probe set was designed to use a 163-bp amplicon from the chromosomally located gene ail (attachment and invasion locus). The selectivity of the PCR method was tested with a diverse range (n = 152) of related and unrelated strains, and no false-negative or false-positive PCR results were obtained. The sensitivity of the PCR amplification was 85 fg purified genomic DNA, equivalent to 10 cells per PCR tube. Following the enrichment of 10 g of various food samples (milk, minced beef, cold-smoked sausage, fish, and carrots), the sensitivity ranged from 0.5 to 55 CFU Y. enterocolitica. Good precision, robustness, and efficiency of the PCR amplification were also established. In addition, the method was tested on naturally contaminated food; in all, 18 out of 125 samples were positive for the ail gene. Since no conventional culture method could be used as a reference method, the PCR products amplified from these samples were positively verified by using conventional PCR and sequencing of the amplicons. A rapid and specific real-time PCR method for the detection of pathogenic Y. enterocolitica bacteria in food, as presented here, provides a superior alternative to the currently available detection methods and makes it possible to identify the foods at risk for Y. enterocolitica contamination.  相似文献   

14.
Adenoviruses 40 and 41 have been recognized as important etiological agents of gastroenteritis in children. A real-time PCR method (TaqMan assay) was developed for rapid quantification of adenovirus 40 (Ad40) by amplifying an 88 bp sequence from the hexon gene. To establish a quantification standard curve, a 1090 bp hexon region of Ad40 was amplified and cloned into the pGEM-T Vector. A direct correlation was observed between the fluorescence threshold cycle number (Ct) and the starting quantity of Ad40 hexon gene. The quantification was linear over 6-log units and the amplification efficiency averaged greater than 95%. Seeding studies using various environmental matrices (including sterile water, creek water, brackish estuarine water, ocean water, and secondary sewage effluent) suggest that this method is applicable to environmental samples. However, real-time PCR was sensitive to inhibitors present in the environmental samples. Lower efficiency of PCR amplification was found in secondary sewage effluent and creek waters. Application of the method to fecal contaminated waters successfully quantified the presence of Ad40. The sensitivity of the real-time PCR is comparable to the traditional nested PCR assay for environmental samples. In addition, the real-time PCR assay offers the advantage of speed and insensitivity to contamination during PCR set up. The real-time PCR assay developed in this study is suitable for quantitative determination of Ad40 in environmental samples and represents a considerable advancement in pathogen quantification in aquatic environments.  相似文献   

15.
Prompted by increasing interest in proportional analysis of genetic types, we developed a simple assay technique for determining the ratio of a specific target gene in the total genes that can be amplified with the same PCR primer. The key feature of this method is that the following two tasks are performed in a single-tube real-time PCR system: task 1, PCR amplification of the total genes including the target using a labeled PCR primer, with concurrent monitoring of the total copy number of the PCR product; task 2, detection of the signal of the target gene at each cycle of amplification, using a labeled nucleotide probe. In principle, the ratio of the target gene to the total genes is represented by the signal detected in 'task 2' at the cycle in which the PCR product reached a prescribed copy number (assessed by 'task 1').  相似文献   

16.
Titer determination is a prerequisite for the study of viruses. However, the current available methods are tedious and time-consuming. To improve the efficiency of titer determination, we have developed a rapid and simple method for the routine detection of baculovirus titers using a quantitative real-time PCR. This method is based on the amplification of approximately 150-bp fragments located in the coding regions of selected genes. The PCR was found to be quantitative in a range of 10(3) to 10(9) virus particles per 200 microL of supernatant, and the results were closely correlated with titers detected from 50% tissue culture infectious doses (TCID(50)) of baculovirus. This quantitative real-time PCR requires only 30 min to perform, and the entire titer determination can be accomplished within 1 h without the need for cell seeding or further virus dilution and infection. Because this technology is easy to operate, generates data with high precision, and most importantly is very quick, it will certainly be broadly applied for titer determination of baculoviruses in the future.  相似文献   

17.
In this paper we describe optimization of SYBR Green I-based real-time PCR parameters and testing of a large number of microbial species with vvh-specific oligonucleotide primers to establish a rapid, specific, and sensitive method for detection of Vibrio vulnificus in oyster tissue homogenate and Gulf of Mexico water (gulf water). Selected oligonucleotide primers for the vvh gene were tested for PCR amplification of a 205-bp DNA fragment with a melting temperature of approximately 87 degrees C for 84 clinical and environmental strains of V. vulnificus. No amplification was observed with other vibrios or nonvibrio strains with these primers. The minimum level of detection by the real-time PCR method was 1 pg of purified genomic DNA or 10(2) V. vulnificus cells in 1 g of unenriched oyster tissue homogenate or 10 ml of gulf water. It was possible to improve the level of detection to one V. vulnificus cell in samples that were enriched for 5 h. The standard curves prepared from the real-time PCR cycle threshold values revealed that there was a strong correlation between the number of cells in unenriched samples and the number of cells in enriched samples. Detection of a single cell of V. vulnificus in 1 g of enriched oyster tissue homogenate is in compliance with the recent Interstate Shellfish Sanitation Conference guidelines. The entire detection method, including sample processing, enrichment, and real-time PCR amplification, was completed within 8 h, making it a rapid single-day assay. Rapid and sensitive detection of V. vulnificus would ensure a steady supply of postharvest treated oysters to consumers, which should help decrease the number of illnesses or outbreaks caused by this pathogen.  相似文献   

18.
Real-time PCR data analysis for quantification has been the subject of many studies aimed at the identification of new and improved quantification methods. Several analysis methods have been proposed as superior alternatives to the common variations of the threshold crossing method. Notably, sigmoidal and exponential curve fit methods have been proposed. However, these studies have primarily analyzed real-time PCR with intercalating dyes such as SYBR Green. Clinical real-time PCR assays, in contrast, often employ fluorescent probes whose real-time amplification fluorescence curves differ from those of intercalating dyes. In the current study, we compared four analysis methods related to recent literature: two versions of the threshold crossing method, a second derivative maximum method, and a sigmoidal curve fit method. These methods were applied to a clinically relevant real-time human herpes virus type 6 (HHV6) PCR assay that used a minor groove binding (MGB) Eclipse hybridization probe as well as an Epstein-Barr virus (EBV) PCR assay that used an MGB Pleiades hybridization probe. We found that the crossing threshold method yielded more precise results when analyzing the HHV6 assay, which was characterized by lower signal/noise and less developed amplification curve plateaus. In contrast, the EBV assay, characterized by greater signal/noise and amplification curves with plateau regions similar to those observed with intercalating dyes, gave results with statistically similar precision by all four analysis methods.  相似文献   

19.
基于荧光定量PCR扩增反应的SNP测定法   总被引:4,自引:0,他引:4  
建立一种利用荧光定量PCR扩增反应进行单核苷酸多态性(SNP)快速测定的方法.以人β肾上腺素受体2基因中的Arg16Gly为研究对象,利用荧光染料SYBRGreenⅠ标记定量PCR产物,通过PCR生长曲线和融解曲线分析结果进行SNP分型.为提高SNP测定的特异性,分别在野生型和突变型等位基因的特异性引物3′端倒数第3个碱基位置,引入了一个人为错配碱基,使引物的错误延伸率显著降低,大大提高了SNP分析的准确性.通过DNA测序验证荧光定量PCR对β肾上腺素受体2基因中Arg16Gly分型结果的准确率.实验结果表明,所建立的方法操作简便,结果准确,适合进行大规模样品的SNP检测工作.  相似文献   

20.
An environmental DNA (eDNA) analysis method has been recently developed to estimate the distribution of aquatic animals by quantifying the number of target DNA copies with quantitative real-time PCR (qPCR). A new quantitative PCR technology, droplet digital PCR (ddPCR), partitions PCR reactions into thousands of droplets and detects the amplification in each droplet, thereby allowing direct quantification of target DNA. We evaluated the quantification accuracy of qPCR and ddPCR to estimate species abundance and biomass by using eDNA in mesocosm experiments involving different numbers of common carp. We found that ddPCR quantified the concentration of carp eDNA along with carp abundance and biomass more accurately than qPCR, especially at low eDNA concentrations. In addition, errors in the analysis were smaller in ddPCR than in qPCR. Thus, ddPCR is better suited to measure eDNA concentration in water, and it provides more accurate results for the abundance and biomass of the target species than qPCR. We also found that the relationship between carp abundance and eDNA concentration was stronger than that between biomass and eDNA by using both ddPCR and qPCR; this suggests that abundance can be better estimated by the analysis of eDNA for species with fewer variations in body mass.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号