In 10 anesthetized, paralyzed, supine dogs, arterial blood gases and CO2 production (VCO2) were measured after 10-min runs of high-frequency ventilation (HFV) at three levels of mean airway pressure (Paw) (0, 5, and 10 cmH2O). HFV was delivered at frequencies (f) of 3, 6, and 9 Hz with a ventilator that generated known tidal volumes (VT) independent of respiratory system impedance. At each f, VT was adjusted at Paw of 0 cmH2O to obtain a eucapnia. As Paw was increased to 5 and 10 cmH2O, arterial PCO2 (PaCO2) increased and arterial PO2 (PaO2) decreased monotonically and significantly. The effect of Paw on PaCO2 and PaO2 was the same at 3, 6, and 9 Hz. Alveolar ventilation (VA), calculated from VCO2 and PaCO2, significantly decreased by 22.7 +/- 2.6 and 40.1 +/- 2.6% after Paw was increased to 5 and 10 cmH2O, respectively. By taking into account the changes in anatomic dead space (VD) with lung volume, VA at different levels of Paw fits the gas transport relationship for HFV derived previously: VA = 0.13 (VT/VD)1.2 VTf (J. Appl. Physiol. 60: 1025-1030, 1986). We conclude that increasing Paw and lung volume significantly decreases gas transport during HFV and that this effect is due to the concomitant increase of the volume of conducting airways.  相似文献   

2.
High-frequency chest percussion (HFP) with constant fresh gas flow (VBF) at the tracheal carina is a variant of high-frequency ventilation (HFV) previously shown to be effective with extremely low tracheal oscillatory volumes (approximately 0.1 ml/kg). We studied the effects of VBF on gas exchange during HFP. In eight anesthetized and paralyzed dogs we measured arterial and alveolar partial pressures of CO2 (PaCO2) and O2 (PaO2) during total body vibration at a frequency of 30 Hz, amplitude of 0.17 +/- 0.019 cm, and tidal volume of 1.56 +/- 0.58 ml. VBF was incrementally varied from 0.1 to 1.2 l.kg-1.min-1. At low flows (0.1-0.4 l.kg-1.min-1), gas exchange was strongly dependent on flow rate but became essentially flow independent with higher VBF (i.e., hyperbolic pattern). At VBF greater than 0.4 l.kg-1.min-1, hyperventilatory blood gas levels were consistently sustained (i.e., PaCO2 less than 20 Torr, PaO2 greater than 90 Torr). The resistance to CO2 transport of the airways was 1.785 +/- 0.657 l-1.kg.min and was independent of VBF. The alveolar-arterial difference of O2 was also independent of the flow. In four of five additional dogs studied as a control group, where constant flow of O2 was used without oscillations, the pattern of PaCO2 vs. VBF was also hyperbolic but at substantially higher levels of PaCO2. It is concluded that, in the range of VBF used, intraairway gas exchange was limited by the 30-Hz vibration. The fresh gas flow was important only to maintain near atmospheric conditions at the tracheal carina.  相似文献   

3.
To investigate the mechanisms responsible for the difference in gas exchange during constant-flow ventilation (CFV) when using gases with different physical properties, we used mixtures of 70% N2-30% O2 (N2-O2) and 70% He-30% O2 (He-O2) as the insufflating gases in 12 dogs. All dogs but one had higher arterial PCO2 (PaCO2) with He-O2 compared with N2-O2. At a flow of 0.37 +/- 0.12 l/s, the mean PaCO2's with N2-O2 and He-O2 were 41.3 +/- 13.9 and 53.7 +/- 20.3 Torr, respectively (P less than 0.01); at a flow rate of 0.84 +/- 0.17 l/s, the mean PaCO2's were 29.1 +/- 11.3 and 35.3 +/- 13.6 Torr, respectively (P less than 0.01). The chest was then opened to alter the apposition between heart and the lungs, thereby reducing the extent of cardiogenic oscillations by 58.4 +/- 18.4%. This intervention did not significantly alter the difference in PaCO2 between N2-O2 and He-O2 from that observed in the intact animals, although the individual PaCO2 values for each gas mixture did increase. When the PaCO2 was plotted against stagnation pressure (rho V2), the difference in PaCO2 between N2-O2 and He-O2 was nearly abolished in both the closed- and open-chest animals. These findings suggest that the different PaCO2's obtained by insufflating gases with different physical properties at a fixed flow rate, catheter position, and lung volume result mainly from a difference in the properties of the jet.  相似文献   

4.
In five anesthetized patients with a Jarvik-7 artificial heart, pulmonary volume displacements generated by cardiogenic oscillations were measured using an indirect spirometric method. Consequences on gas exchange were also evaluated during a 15-min period of apnea by use of a tracheal insufflation of pure O2 at a constant flow rate of 20 l/min. The Jarvik-7 artificial heart generated a mean pulmonary volume displacement of 105 +/- 29 (SD) ml/heart beat. After 15 min of apnea, arterial PCO2 (PaCO2) significantly increased from 29 +/- 5 to 47 +/- 6 (SD) Torr. PaCO2 increased by 0.8 Torr/min from the 5th to the 15th min of apnea. Mean arterial PO2, mean pulmonary shunt, mean O2 consumption, and mean metabolic production of CO2 did not change significantly during the apnea period. Because cardiac output was kept constant during the study, O2 transport was adequately maintained throughout the apnea period. In patient 1, where the period of apnea was continued for 60 min, PaCO2 progressively increased until the 45th min and then remained stable at 61 Torr during the last 15 min of apnea. This "plateau" corresponded to an alveolar ventilation of 3,907 ml/min, representing 69% of the alveolar ventilation calculated during conventional mechanical ventilation. In conclusion, the Jarvik-7 artificial heart provides a potent respiratory support through the cardiogenic oscillations it generates.  相似文献   

5.
Pulmonary clearance of 99mTc-DTPA: influence of background activity   总被引:4,自引:0,他引:4  
To study the effects of circulatory occlusion on the time course and magnitude of postexercise O2 consumption (VO2) and blood lactate responses, nine male subjects were studied twice for 50 min on a cycle ergometer. On one occasion, leg blood flow was occluded with surgical thigh cuffs placed below the buttocks and inflated to 200 mmHg. The protocol consisted of a 10-min rest, 12 min of exercise at 40% peak O2 consumption (VO2 peak), and a 28-min resting recovery while respiratory gas exchange was determined breath by breath. Occlusion (OCC) spanned min 6-8 during the 12-min work bout and elicited mean blood lactate of 5.2 +/- 0.8 mM, which was 380% greater than control (CON). During 18 min of recovery, blood lactate after OCC remained significantly above CON values. VO2 was significantly lower during exercise with OCC compared with CON but was significantly higher during the 4 min of exercise after cuff release. VO2 was higher after OCC during the first 4 min of recovery but was not significantly different thereafter. Neither total recovery VO2 (gross recovery VO2 with no base-line subtraction) nor excess postexercise VO2 (net recovery VO2 above an asymptotic base line) was significantly different for OCC and CON conditions (13.71 +/- 0.45 vs. 13.44 +/- 0.61 liters and 4.93 +/- 0.26 vs. 4.17 +/- 0.35 liters, respectively). Manipulation of exercise blood lactate levels had no significant effect on the slow ("lactacid") component of the recovery VO2.  相似文献   

6.
We aimed to test effects of altitude acclimatization on pulmonary gas exchange at maximal exercise. Six lowlanders were studied at sea level, in acute hypoxia (AH), and after 2 and 8 wk of acclimatization to 4,100 m (2W and 8W) and compared with Aymara high-altitude natives residing at this altitude. As expected, alveolar Po2 was reduced during AH but increased gradually during acclimatization (61 +/- 0.7, 69 +/- 0.9, and 72 +/- 1.4 mmHg in AH, 2W, and 8W, respectively), reaching values significantly higher than in Aymaras (67 +/- 0.6 mmHg). Arterial Po2 (PaO2) also decreased during exercise in AH but increased significantly with acclimatization (51 +/- 1.1, 58 +/- 1.7, and 62 +/- 1.6 mmHg in AH, 2W, and 8W, respectively). PaO2 in lowlanders reached levels that were not different from those in high-altitude natives (66 +/- 1.2 mmHg). Arterial O2 saturation (SaO2) decreased during maximum exercise compared with rest in AH and after 2W and 8W: 73.3 +/- 1.4, 76.9 +/- 1.7, and 79.3 +/- 1.6%, respectively. After 8W, SaO2 in lowlanders was not significantly different from that in Aymaras (82.7 +/- 1%). An improved pulmonary gas exchange with acclimatization was evidenced by a decreased ventilatory equivalent of O2 after 8W: 59 +/- 4, 58 +/- 4, and 52 +/- 4 l x min x l O2(-1), respectively. The ventilatory equivalent of O2 reached levels not different from that of Aymaras (51 +/- 3 l x min x l O2(-1)). However, increases in exercise alveolar Po2 and PaO2 with acclimatization had no net effect on alveolar-arterial Po2 difference in lowlanders (10 +/- 1.3, 11 +/- 1.5, and 10 +/- 2.1 mmHg in AH, 2W, and 8W, respectively), which remained significantly higher than in Aymaras (1 +/- 1.4 mmHg). In conclusion, lowlanders substantially improve pulmonary gas exchange with acclimatization, but even acclimatization for 8 wk is insufficient to achieve levels reached by high-altitude natives.  相似文献   

7.
Constant-flow ventilation in pigs   总被引:2,自引:0,他引:2  
Constant-flow ventilation (CFV) is a ventilatory technique in which physiological blood gases can be maintained in dogs by a constant flow of fresh gas introduced via two catheters placed in the main-stem bronchi (J. Appl. Physiol. 53: 483-489, 1982). High-velocity gas exiting from the catheters can create uneven pressure differences in adjacent lung segments, and these pressure differences could lead to gas flow through collateral channels. To examine this hypothesis, we studied CFV in pigs, animals known to have a high resistance to collateral ventilation. In three pigs we examined steady-state gas exchange, and in six others we studied unsteady gas exchange at three flow rates (20, 35, and 50 l/min) and three catheter positions (0.5, 1.5, and 2.5 cm distal to the tracheal carina). During steady-state runs we were unable to attain normocapnia; the arterial CO2 partial pressure (PaCO2) was approximately 300 Torr at all flow rates and all catheter positions, compared with 20-50 Torr at similar flows and positions in dogs studied previously. The initial unsteady gas-exchange experiments indicated no consistent effect of catheter position or flow rate on the rate of rise of PaCO2. In three other pigs, the rates of rise of PaCO2 were compared with the rates observed with apneic oxygenation (AO). At the maximum flow and deepest position, the rate of rise of PaCO2 was lower during CFV than during AO. These data suggest that flow through collateral channels might be important in producing adequate gas transport during CFV; however, other factors such as airway morphometry and the effects of cardiogenic oscillations may explain the differences between the results in pigs and dogs.  相似文献   

8.
The effects of mild hypoxia on brain oxyhemoglobin, cytochrome a,a3 redox status, and cerebral blood volume were studied using near-infrared spectroscopy in eight healthy volunteers. Incremental hypoxia reaching 70% arterial O2 saturation was produced in normocapnia [end-tidal PCO2 (PETCO2) 36.9 +/- 2.6 to 34.9 +/- 3.4 Torr] or hypocapnia (PETCO2 32.8 +/- 0.6 to 23.7 +/- 0.6 Torr) by an 8-min rebreathing technique and regulation of inspired CO2. Normocapnic hypoxia was characterized by progressive reductions in arterial PO2 (PaO2, 89.1 +/- 3.5 to 34.1 +/- 0.1 Torr) with stable PETCO2, arterial PCO2 (PaCO2), and arterial pH and resulted in increases in heart rate (35%) systolic blood pressure (14%), and minute ventilation (5-fold). Hypocapnic hypoxia resulted in progressively decreasing PaO2 (100.2 +/- 3.6 to 28.9 +/- 0.1 Torr), with progressive reduction in PaCO2 (39.0 +/- 1.6 to 27.3 +/- 1.9 Torr), and an increase in arterial pH (7.41 +/- 0.02 to 7.53 +/- 0.03), heart rate (61%), and ventilation (3-fold). In the brain, hypoxia resulted in a steady decline of cerebral oxyhemoglobin content and a decrease in oxidized cytochrome a,a3. Significantly greater loss of oxidized cytochrome a,a3 occurred for a given decrease in oxyhemoglobin during hypocapnic hypoxia relative to normocapnic hypoxia. Total blood volume response during hypoxia also was significantly attenuated by hypocapnia, because the increase in volume was only half that of normocapnic subjects. We conclude that cytochrome a,a3 oxidation level in vivo decreases at mild levels of hypoxia. PaCO is an important determinant of brain oxygenation, because it modulates ventilatory, cardiovascular, and cerebral O2 delivery responses to hypoxia.  相似文献   

9.
High-frequency external body vibration, combined with constant gas flow at the tracheal carina, was previously shown to be an effective method of ventilation in normal dogs. The effects of frequency (f) and amplitude of the vibration were investigated in the present study. Eleven anesthetized and paralyzed dogs were placed on a vibrating table (4-32 Hz). O2 was delivered near the tracheal carina at 0.51.kg-1.min-1, while mean airway pressure was kept at 2.4 +/- 0.9 cmH2O. Table vertical displacement (D) and acceleration (a), esophageal (Pes), and tracheal (Ptr) peak-to-peak pressures, and tidal volume (VT) were measured as estimates of the input amplitude applied to the animal. Steady-state arterial PCO2 (PaCO2) and arterial PO2 (PaO2) values were used to monitor overall gas exchange. Typically, eucapnia was achieved with f greater than 16 Hz, D = 1 mm, a = 1 G, Pes = Ptr = 4 +/- 2 cmH2O, and VT less than 2 ml. Inverse exponential relationships were found between PaCO2 and f, a, Pes, and Ptr (exponents: -0.69, -0.38, -0.48, and -0.54, respectively); PaCO2 decreased linearly with increased displacement or VT at a fixed frequency (17 +/- 1 Hz). PaO2 was independent of both f and D (393 +/- 78 Torr, mean +/- SD). These data demonstrate the very small VT, Ptr, and Pes associated with vibration ventilation. It is clear, however, that mechanisms other then those described for conventional ventilation and high-frequency ventilation must be evoked to explain our data. One such possible mechanism is forcing of flow oscillation between lung regions (i.e., forced pendelluft).  相似文献   

10.
In five patients with hypoxic chronic bronchitis and emphysema we measured ear O2 saturation (SaO2), chest movement, oronasal airflow, arterial and mixed venous gas tensions, and cardiac output during nine hypoxemic episodes (HE; SaO2 falls greater than 10%) in rapid-eye-movement (REM) sleep and during preceding periods of stable oxygenation in non-REM sleep. All nine HE occurred with recurrent short episodes of reduced chest movement, none with sleep apnea. The arterial PO2 (PaO2) fell by 6.0 +/- 1.9 (SD) Torr during the HE (P less than 0.01), but mean arterial PCO2 (PaCO2) rose by only 1.4 +/- 2.4 Torr (P greater than 0.4). The arteriovenous O2 content difference fell by 0.64 +/- 0.43 ml/100 ml of blood during the HE (P less than 0.05), but there was no significant change in cardiac output. Changes observed in PaO2 and PaCO2 during HE were similar to those in four normal subjects during 90 s of voluntary hypoventilation, when PaO2 fell by 12.3 +/- 5.6 Torr (P less than 0.05), but mean PaCO2 rose by only 2.8 +/- 2.1 Torr (P greater than 0.4). We suggest that the transient hypoxemia which occurs during REM sleep in patients with chronic bronchitis and emphysema could be explained by hypoventilation during REM sleep but that the importance of changes in distribution of ventilation-perfusion ratios cannot be assessed by presently available techniques.  相似文献   

11.
Arterial-alveolar equilibration of CO2 during exercise was studied by normoxic CO2 rebreathing in six dogs prepared with a chronic tracheostomy and exteriorized carotid loop and trained to run on a treadmill. In 153 simultaneous measurements of PCO2 in arterial blood (PaCO2) and end-tidal gas (PE'CO2) obtained in 46 rebreathing periods at three levels of mild-to-moderate steady-state exercise, the mean PCO2 difference (PaCO2-PE'CO2) was -1.0 +/- 1.0 (SD) Torr and was not related to O2 uptake or to the level of PaCO2 (30-68 Torr). The small negative PaCO2-PE'CO2 is attributed to the lung-to-carotid artery transit time delay which must be taken into account when both PaCO2 and PE'CO2 are continuously rising during rebreathing (average rate 0.22 Torr/s). Assuming that blood-gas equilibrium for CO2 was complete, a lung-to-carotid artery circulation time of 4.6 s accounts for the observed uncorrected PaCO2-PE'CO2 of -1.0 Torr. The results are interpreted to indicate that in rebreathing equilibrium PCO2 in arterial blood and alveolar gas are essentially identical. This conclusion is at variance with previous studies in exercising humans during rebreathing but is in full agreement with our recent findings in resting dogs.  相似文献   

12.
We studied the effect of mean airway pressure (Paw) on gas exchange during high-frequency oscillatory ventilation in 14 adult rabbits before and after pulmonary saline lavage. Sinusoidal volume changes were delivered through a tracheostomy at 16 Hz, a tidal volume of 1 or 2 ml/kg, and inspired O2 fraction of 0.5. Arterial PO2 and PCO2 (PaO2, PaCO2), lung volume change, and venous admixture were measured at Paw from 5 to 25 cmH2O after either deflation from total lung capacity or inflation from relaxation volume (Vr). The rabbits were lavaged with saline until PaO2 was less than 70 Torr, and all measurements were repeated. Lung volume change was measured in a pressure plethysmograph. Raising Paw from 5 to 25 cmH2O increased lung volume by 48-50 ml above Vr in both healthy and lavaged rabbits. Before lavage, PaO2 was relatively insensitive to changes in Paw, but after lavage PaO2 increased with Paw from 42.8 +/- 7.8 to 137.3 +/- 18.3 (SE) Torr (P less than 0.001). PaCO2 was insensitive to Paw change before and after lavage. At each Paw after lavage, lung volume was larger, venous admixture smaller, and PaO2 higher after deflation from total lung capacity than after inflation from Vr. This study shows that the effect of increased Paw on PaO2 is mediated through an increase in lung volume. In saline-lavaged lungs, equal distending pressures do not necessarily imply equal lung volumes and thus do not imply equal PaO2.  相似文献   

13.
In this study, the rapid (within 2 h) effects of acute anaemia on blood gas and acid-base status, as well as cardiorespiratory variables, were examined in brown bullhead (Ameiurus nebulosus). Anaemia was induced by blood withdrawal coupled to volume replacement with saline. Lowering haematocrit from the control value of 23.5+/-1.0% (mean+/-S.E.M.; N=37) to 5.9+/-0.3% (N=37) resulted in a significant increase (by 2.63+/-0.51 torr; N=7) in arterial CO(2) tension (PaCO(2)) over the subsequent 2-h period in the absence of a change in arterial O(2) tension (PaO(2)). Treatment with bovine carbonic anhydrase (CA) reduced the extent of the PaCO(2) increase to the point where it was not statistically significant. In both control and CA-treated fish, arterial pH decreased during acute anaemia; the acidosis was of mixed respiratory and metabolic origin in control fish and primarily metabolic in CA-treated fish. Inducing anaemia caused increases in both cardiac output (V*b) and heart rate that were similar in control and CA-treated fish. Experimental elevation of V*b equivalent to that observed during anaemia, but in the absence of lowered haematocrit, increased PaCO(2) significantly by 1.49+/-0.74 to 1.64+/-0.78 torr (N=5) without affecting PaO(2). These findings suggest that CO(2) excretion in bullhead, as in rainbow trout, is effectively diffusion-limited, and that approximately half of the increase in PaCO(2) measured during the initial 2 h of anaemia results from the impact of increased blood flow (hence decreased gill transit time) in a diffusion-limited system.  相似文献   

14.
Fetal breathing adaptation to prolonged hypoxaemia in sheep   总被引:1,自引:0,他引:1  
Prolonged (6 days) fetal hypoxaemia was produced by placing pregnant ewes in an environmental chamber. A constant flow of N2 into the chamber reduced the fraction of inspired oxygen (Fi02) to 0.139 +/- 0.001, simulating an altitude of 4270 m. This reduced maternal PaO2 by about 39 mmHg and PaCO2 by nearly 5 mmHg, which produced a hypocapnic (delta PaCO2 = -5 mmHg) hypoxaemia (delta PaO2 = -8 mmHg) in the fetus. An analysis of the first 4 h of breathing recorded each day (1800-2200 h; start of hypoxaemia: 1200 h) showed that the incidence (12 +/- 2.0 min/day) during the first day of hypoxaemia was significantly less (P less than 0.05) than that (24 +/- 3.1 min/h) during the same time of the control day. By the second day, breathing had returned to normal. Further analysis indicated that a normal incidence of breathing may have occurred as early as 14 h after starting hypoxaemia. These results suggest that fetal breathing movements adapt rather quickly to this degree of hypocapnic hypoxaemia.  相似文献   

15.
The factors that determine maximal O2 uptake (VO2max) and muscle performance during severe, acute hypoxemia were studied in isolated, in situ dog gastrocnemius muscle. Our hypothesis that VO2max is limited by O2 diffusion in muscle predicts that decreases in VO2max, caused by hypoxemia, will be accompanied by proportional decreases in muscle effluent venous PO2 (PvO2). By altering the fraction of inspired O2, four levels of arterial PO2 (PaO2) [21 +/- 2, 28 +/- 1, 44 +/- 1, and 80 +/- 2 (SE) Torr] were induced in each of eight dogs. Muscle arterial and venous circulation was isolated and arterial pressure held constant by pump perfusion. Each muscle worked maximally (3 min at 5-6 Hz, isometric twitches) at each PaO2. Arterial and venous samples were taken to measure lactate, [H+], PO2, PCO2, and muscle VO2. Muscle biopsies were taken to measure [H+] (homogenate method) and lactate. VO2max decreased with PaO2 and was linearly (R = 0.99) related to both PVO2 and O2 delivery. As PaO2 fell, fatigue increased while muscle lactate and [H+] increased. Lactate release from the muscle did not change with PaO2. This suggests a barrier to lactate efflux from muscle and a possible cause of the greater fatigue seen in hypoxemia. The gas exchange data are consistent with the hypothesis that VO2max is limited by peripheral tissue diffusion of O2.  相似文献   

16.
目的:探讨不同体位对严重肥胖者血氧饱和度的影响。方法:16名平均体重指数(BMI)为40±5肥胖者和16名年龄匹配的正常体重者被纳入研究。分别在不同体外下(坐位、仰卧位、侧卧位)对所有参与者进行动脉血气监测。结果:肥胖者于坐位时动脉Pa O_2为75±4 mm Hg,Pa CO_2为37±3 mm Hg;仰卧位时动脉Pa O_2为62±5 mm Hg,Pa CO_2为47±5 mm Hg;侧卧位时Pa O_2为73±3 mm Hg,Pa CO_2为39±2 mm Hg;而正常体重者无明显变化。结论:严重肥胖者于平卧位时更容易出现低氧及高碳酸血症。  相似文献   

17.
Ten free-ranging female sika deer (Cervus nippon) were captured to obtain the reference values for acid-base status and blood gas when immobilized with the combination of medetomidine and ketamine. The mean +/- SE of PaCO2, PaO2, and HCO3- were 58.1 +/- 6.1 mmHg, 58.8 +/- 6.4 mmHg, and 36.0 +/- 4.4 mmol/l, respectively. Although acidosis and alkalosis occurred in three and two animals, respectively, no serious conditions were observed. The blood values, however, suggest that some degree of hypoxemia and respiratory acidosis with metabolic alkalosis are developed. The trapped deer showed a significantly higher than normal rectal temperature reflective of exertion.  相似文献   

18.
Pulmonary gas exchange in panting dogs   总被引:1,自引:0,他引:1  
Pulmonary gas exchange during panting was studied in seven conscious dogs (32 kg mean body wt) provided with a chronic tracheostomy and an exteriorized carotid artery loop. The animals were acutely exposed to moderately elevated ambient temperature (27.5 degrees C, 65% relative humidity) for 2 h. O2 and CO2 in the tracheostomy tube were continuously monitored by mass spectrometry using a special sample-hold phase-locked sampling technique. PO2 and PCO2 were determined in blood samples obtained from the carotid artery. During the exposure to heat, central body temperature remained unchanged (38.6 +/- 0.6 degrees C) while all animals rapidly switched to steady shallow panting at frequencies close to the resonant frequency of the respiratory system. During panting, the following values were measured (means +/- SD): breathing frequency, 313 +/- 19 breaths/min; tidal volume, 167 +/- 21 ml; total ventilation, 52 +/- 9 l/min; effective alveolar ventilation, 5.5 +/- 1.3 l/min; PaO2, 106.2 +/- 5.9 Torr; PaCO2, 27.2 +/- 3.9 Torr; end-tidal-arterial PO2 difference [(PE' - Pa)O2], 26.0 +/- 5.3 Torr; and arterial-end-tidal PCO2 difference, [(Pa - PE')CO2], 14.9 +/- 2.5 Torr. On the basis of the classical ideal alveolar air approach, parallel dead-space ventilation accounted for 54% of alveolar ventilation and 66% of the (PE' - Pa)O2 difference. But the steepness of the CO2 and O2 expirogram plotted against expired volume suggested a contribution of series in homogeneity due to incomplete gas mixing.  相似文献   

19.
Isocapnic hypoxaemia (delta PaO2 = -8.0 +/- 0.5 mmHg; delta CaO2 = -2.86 +/- 0.20 ml/dl) was produced in fetal sheep by having the ewe breathe for one hour a gas mixture (v/v) of 10.5% O2 and 1.5% CO2 in N2. Mean fetal heart rate, blood pressure, and incidence of low voltage electrocortical activity were not affected. However, the incidence of rapid-eye-movements and breathing activity was reduced by about 40%. Breathing movements during hypoxaemia had a mean inspiratory time, breath interval, and tracheal pressure amplitude which did not differ significantly from those during control experiments in which the ewe breathed air from the plastic bag. These observations suggest that hypoxia decreases the incidence of breathing movements but does not affect the amplitude or pattern of breathing activity and that it may reduce the incidence of eye movements and breathing activity through a common mechanism.  相似文献   

20.
The objective of this study was to determine whether arterial PCO2 (PaCO2) decreases or remains unchanged from resting levels during mild to moderate steady-state exercise in the dog. To accomplish this, O2 consumption (VO2) arterial blood gases and acid-base status, arterial lactate concentration ([LA-]a), and rectal temperature (Tr) were measured in 27 chronically instrumented dogs at rest, during different levels of submaximal exercise, and during maximal exercise on a motor-driven treadmill. During mild exercise [35% of maximal O2 consumption (VO2 max)], PaCO2 decreased 5.3 +/- 0.4 Torr and resulted in a respiratory alkalosis (delta pHa = +0.029 +/- 0.005). Arterial PO2 (PaO2) increased 5.9 +/- 1.5 Torr and Tr increased 0.5 +/- 0.1 degree C. As the exercise levels progressed from mild to moderate exercise (64% of VO2 max) the magnitude of the hypocapnia and the resultant respiratory alkalosis remained unchanged as PaCO2 remained 5.9 +/- 0.7 Torr below and delta pHa remained 0.029 +/- 0.008 above resting values. When the exercise work rate was increased to elicit VO2 max (96 +/- 2 ml X kg-1 X min-1) the amount of hypocapnia again remained unchanged from submaximal exercise levels and PaCO2 remained 6.0 +/- 0.6 Torr below resting values; however, this response occurred despite continued increases in Tr (delta Tr = 1.7 +/- 0.1 degree C), significant increases in [LA-]a (delta [LA-]a = 2.5 +/- 0.4), and a resultant metabolic acidosis (delta pHa = -0.031 +/- 0.011). The dog, like other nonhuman vertebrates, responded to mild and moderate steady-state exercise with a significant hyperventilation and respiratory alkalosis.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   