首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
人类呼出气体中的各种化合物能提供各种疾病和健康状况的重要信息。近年来,由于红外、电化学、化学发光等新技术的重大突破和质谱仪的使用,使得在极低浓度下精确测量呼出的挥发性有机化合物(VOCs)和气溶胶颗粒成为可能,呼吸检测领域因而取得了重大进展:,呼吸检测因其可以作为一种实时、快速和无创的方法来评估和监测各种疾病与健康状况信息,在科学研究、临床运用中引起了广泛关注。本综述主要概述呼出气体成分分析方法及在疾病诊断中的研究与应用情况,旨在为将来疾病的实时、快速和无创诊断提供一种新的策略.  相似文献   

2.
Breath analysis, including measurement of nitric oxide (NO), is a noninvasive diagnostic tool that may help evaluate cetacean health. This is the first report on the effects of breath hold duration, feeding, and lung disease on NO in dolphin exhaled breath. Three healthy dolphins were trained to hold their breath for 30, 60, 90, and 120 s and then exhale into an underwater funnel. Exhaled NO values from 157 breath samples were compared among three healthy dolphins by breath hold time and after fasting and feeding. Exhaled NO values were also measured in two dolphins with pulmonary disease. NO in dolphin breath was higher compared to ambient air; healthy dolphins had higher NO concentrations in their breath after feeding compared to after overnight fasting; and there were no significant differences in exhaled NO levels by breath hold duration. A dolphin with Mycoplasma‐associated pneumonia and chronic gastrointestinal disease had higher postprandial exhaled NO levels compared to healthy controls. This study demonstrates, contrary to previous publications, that dolphins exhale NO. Given the high standard deviations present in exhaled breath NO values, future studies are needed to further standardize collection methods or identify more reliable samples (e.g., blood).  相似文献   

3.
The study was designed to investigate whether exhaled breath condensate, obtained by cooling exhaled air in spontaneous breathing, could be a suitable matrix for toluene quantitative analyses. Nine healthy subjects were exposed for a short period (20 min) to a known concentration of toluene. Exhaled breath condensate samples were collected before and at the end of the exposure, while the environmental concentration of toluene was continuously monitored. Toluene was analysed by head-space gas-chromatography mass spectrometry, and assay repeatability was also estimated in vitro. Baseline and post-exposure measurement of hippuric acid, the urinary toluene metabolite, was performed to assess current toluene exposure. Before the exposure toluene concentrations in the exhaled breath condensate were lower than the detectable limit in all subjects, while after the exposure toluene was detectable with a median value 0.35 µg l-1 (range 0.15-0.55 µg l-1) in all the exhaled breath condensate samples. As compared with the standard calibration in distilled water, the curves obtained by exhaled breath condensate were linear and comparable with the range examined in vivo for toluene. A significant correlation was found between the environmental toluene levels and toluene in the exhaled breath condensate at the end of exposure. Furthermore, a significant relationship between increased exhaled breath condensate toluene levels and urinary hippuric acid after the exposure was found. In conclusion, exhaled breath condensate is a promising matrix for toluene assessment, although its application in humans requires further investigations.  相似文献   

4.
Abstract

The study was designed to investigate whether exhaled breath condensate, obtained by cooling exhaled air in spontaneous breathing, could be a suitable matrix for toluene quantitative analyses. Nine healthy subjects were exposed for a short period (20 min) to a known concentration of toluene. Exhaled breath condensate samples were collected before and at the end of the exposure, while the environmental concentration of toluene was continuously monitored. Toluene was analysed by head-space gas-chromatography mass spectrometry, and assay repeatability was also estimated in vitro. Baseline and post-exposure measurement of hippuric acid, the urinary toluene metabolite, was performed to assess current toluene exposure. Before the exposure toluene concentrations in the exhaled breath condensate were lower than the detectable limit in all subjects, while after the exposure toluene was detectable with a median value 0.35 µg l?1 (range 0.15–0.55 µg l?1) in all the exhaled breath condensate samples. As compared with the standard calibration in distilled water, the curves obtained by exhaled breath condensate were linear and comparable with the range examined in vivo for toluene. A significant correlation was found between the environmental toluene levels and toluene in the exhaled breath condensate at the end of exposure. Furthermore, a significant relationship between increased exhaled breath condensate toluene levels and urinary hippuric acid after the exposure was found. In conclusion, exhaled breath condensate is a promising matrix for toluene assessment, although its application in humans requires further investigations.  相似文献   

5.
At present drugs of abuse testing using exhaled breath as specimen is only possible for alcohol. However, we recently discovered that using modern liquid chromatography–mass spectrometry technique amphetamine and methamphetamine is detectable in exhaled breath following intake in drug addicts. We therefore undertook to develop a method for determination of methadone in exhaled breath from patients undergoing methadone maintenance treatment. Exhaled breath was collected from 13 patients after intake of the daily methadone dose. The compounds were trapped by filtering the air through a C18 modified silica surface. After elution of any trapped methadone the extract was analysed by a combined liquid chromatography–tandem mass spectrometry method. Recovery of trapped methadone from the filter surface was 96%, no significant matrix effect was observed, and the quantification using methadone-d3 as an internal standard was accurate (<10% bias) and precise (coefficient of variation 1.6–2.0%). Methadone was indisputably identified by means of the mass spectrometry technique in exhaled breath samples from all 13 patients. Identification was based on monitoring two product ions in selected reaction monitoring mode with correct relative ratio (±20%) and correct retention time. Excretion rates ranged from 0.39 to 78 ng/min. No methadone was detected in 10 control subjects. This finding confirms that breath testing is a new possibility for drugs of abuse testing. Collection of exhaled breath specimen is likely to be more convenient and safe as compared to other matrices presently in use.  相似文献   

6.
Effects of ventilation on the collection of exhaled breath in humans.   总被引:1,自引:0,他引:1  
A computerized system has been developed to monitor tidal volume, respiration rate, mouth pressure, and carbon dioxide during breath collection. This system was used to investigate variability in the production of breath biomarkers over an 8-h period. Hyperventilation occurred when breath was collected from spontaneously breathing study subjects (n = 8). Therefore, breath samples were collected from study subjects whose breathing were paced at a respiration rate of 10 breaths/min and whose tidal volumes were gauged according to body mass. In this "paced breathing" group (n = 16), end-tidal concentrations of isoprene and ethane correlated with end-tidal carbon dioxide levels [Spearman's rank correlation test (r(s)) = 0.64, P = 0.008 and r(s) = 0.50, P = 0.05, respectively]. Ethane also correlated with heart rate (r(s) = 0.52, P < 0.05). There was an inverse correlation between transcutaneous pulse oximetry and exhaled carbon monoxide (r(s) = -0.64, P = 0.008). Significant differences were identified between men (n = 8) and women (n = 8) in the concentrations of carbon monoxide (4 parts per million in men vs. 3 parts per million in women; P = 0.01) and volatile sulfur-containing compounds (134 parts per billion in men vs. 95 parts per billion in women; P = 0.016). There was a peak in ethanol concentration directly after food consumption and a significant decrease in ethanol concentration 2 h later (P = 0.01; n = 16). Sulfur-containing molecules increased linearly throughout the study period (beta = 7.4, P < 0.003). Ventilation patterns strongly influence quantification of volatile analytes in exhaled breath and thus, accordingly, the breathing pattern should be controlled to ensure representative analyses.  相似文献   

7.
Abstract

Air pollution and cigarette smoke are recognized health risks. A method was developed for the measurement of the deposition fraction (DF) of polydisperse particulate matter (PM) in human airways. Ten normal volunteers [three females, age range 18–67 years, mean age (SD) 43.9 (14)] made single breath exhalations after inhalation to total lung capacity. The exhaled breath was diverted to a multichannel laser diffraction chamber where the particulate profiler measured 0.3–1.0-µm particles. DF was inversely related to expiration flow-rate, 0.69 (0.02) at 4 l min?1 and 0.5 (0.01) at 13 l min?1, respectively (p<0.05), and was influenced by the inhalation flow-rate [0.70 (0.02) at 3 l min?1 and 0.59 (0.02) at 13 l min?1, respectively (p<0.05)], while no differences were found between nasal and oral inhalation (0.68 (0.05) versus 0.67 (0.06), p>0.05). Higher breath holding times were associated with elevated DF [0.74 (0.02) at 20 s, and 0.62 (0.05) without breath holding (p<0.01)]. When the expiratory flow was controlled and the breath hold time standardized, DF was reproducible (CV?=?4.85%). PM can be measured in the exhaled breath and its DF can be quantified using a portable device. These methods may be useful in studies investigating the health effects of air pollution and tobacco smoke.  相似文献   

8.
Biomarkers of some pulmonary diseases in exhaled breath   总被引:16,自引:0,他引:16  
Analysis of various biomarkers in exhaled breath allows completely non-invasive monitoring of inflammation and oxidative stress in the respiratory tract in inflammatory lung diseases, including asthma, chronic obstructive pulmonary disease (COPD), cystic fibrosis (CF), bronchiectasis and interstitial lung diseases. The technique is simple to perform, may be repeated frequently, and can be applied to children, including neonates, and patients with severe disease in whom more invasive procedures are not possible. Several volatile chemicals can be measured in the breath (nitric oxide, carbon monoxide, ammonia), and many non-volatile molecules (mediators, oxidation and nitration products, proteins) may be measured in exhaled breath condensate. Exhaled breath analysis may be used to quantify inflammation and oxidative stress in the respiratory tract, in differential diagnosis of airway disease and in the monitoring of therapy. Most progress has been made with exhaled nitric oxide (NO), which is increased in atopic asthma, is correlated with other inflammatory indices and is reduced by treatment with corticosteroids and antileukotrienes, but not (β2-agonists. In contrast, exhaled NO is normal in COPD, reduced in CF and diagnostically low in primary ciliary dyskinesia. Exhaled carbon monoxide (CO) is increased in asthma, COPD and CF. Increased concentrations of 8-isoprostane, hydrogen peroxide, nitrite and 3-nitrotyrosine are found in exhaled breath condensate in inflammatory lung diseases. Furthermore, increased levels of lipid mediators are found in these diseases, with a differential pattern depending on the nature of the disease process. In the future it is likely that smaller and more sensitive analysers will extend the discriminatory value of exhaled breath analysis and that these techniques may be available to diagnose and monitor respiratory diseases in the general practice and home setting.  相似文献   

9.
《Biomarkers》2013,18(6):476-484
Context: Pregnancy-linked accelerated metabolism and oxidative stress may alter the exhaled volatile compound pattern (“breathprint”). Electronic noses can distinguish “breathprints” associated with different disorders.

Objective: This is the first study assessing alterations in “breathprint” during gestation.

Material and methods: 130 women participated in our study (78 pregnant vs. 52 non-pregnant). Breath samples were processed by an electronic nose and analyzed using principal component analysis.

Results: Significant differences were found in exhaled breath pattern between pregnant and non-pregnant women (p?=?0.001).

Conclusion: Pregnancy-induced changes in exhaled gases need to be considered when pregnant women with respiratory disorders carry out breath tests.  相似文献   

10.

Background

Exhaled breath gases are becomingly increasingly investigated for use as non-invasive measurements for clinical diagnosis, prognosis and therapeutic monitoring. Exhaled volatile organic compounds (VOCs) in the breath, which make up the exhaled volatilome, offer a rich sample medium that provides both information to external exposures as well as endogenous metabolism. For these reasons, exhaled breath analyses can be extended further beyond disease-based investigations, and used for wider biomarker measurement purposes. The use of a rapid, non-invasive (and potentially non-physically demanding) test in an exercise and/or sporting situation may provide additional information for translation to performance sport, recreational exercise/fitness and clinical exercise health.

Aim of review

This review intends to provide an overview into the initial exploration of exhaled VOC measurements in sport and exercise science, and understand current limitations in knowledge and instrumentation that have restricted these methodologies in becoming common practice.

Key scientific concepts of review

Exhaled VOCs have been applied to sport/exercise investigations with a current emphasis on measurement of chemical exposure during and/or following exercise. This includes the measurement of disinfection by-products from chlorine-disinfected swimming pools, as well as exposure to petrochemicals from combustion engines (e.g. vehicle fumes). However, exhaled VOC measurements have been less employed in the context of performance sport. For example, the application of exhaled VOCs to map biochemical/physiological processes of intense exercise is currently under explored and warrants further study. Nevertheless, there is promise for exhaled VOC testing in the development of rapid/on-line anti-doping screens, with initial steps taken in this field.
  相似文献   

11.
A method is described for rapidly measuring the ethane concentration in exhaled human breath. Ethane is considered a volatile marker for lipid peroxidation. The breath samples are analyzed in real time during single exhalations by means of infrared cavity leak-out spectroscopy. This is an ultrasensitive laser-based method for the analysis of trace gases on the sub-parts per billion level. We demonstrate that this technique is capable of online quantifying of ethane traces in exhaled human breath down to 500 parts per trillion with a time resolution of better than 800 ms. This study includes what we believe to be the first measured expirograms for trace fractions of ethane. The expirograms were recorded after a controlled inhalation exposure to 1 part per million of ethane. The normalized slope of the alveolar plateau was determined, which shows a linear increase over the first breathing cycles and ends in a mean value between 0.21 and 0.39 liter-1. The washout process was observed for a time period of 30 min and was modelled by a threefold exponential decay function, with decay times ranging from 12 to 24, 341 to 481, and 370 to 1770 s. Our analyzer provides a promising noninvasive tool for online monitoring of the oxidative stress status.  相似文献   

12.
《Biomarkers》2013,18(7):583-593
Asthma-related symptoms can manifest in children during the early years, but only some of the children will develop the disease. This feasibility study showed that it is possible to apply non-invasive markers (in urine, exhaled nitric oxide (FENO) and exhaled breath condensate (EBC)) in 3-year-old children, and evaluated the biomarkers in relation to health outcomes and potential modifiers. FENO was correlated with respiratory allergy, and was borderline significantly correlated with wheezing, but not with the asthma predictive index (mAPI). EBC pH and urinary 8-oxo-deoxyguanosine were not significantly correlated with these clinical outcomes. An EBC proteolytic peptide pattern was developed, which could distinguish between mAPI-positive and -negative children. Non-invasive biomarkers may become a promising tool for investigating respiratory health in children but further research is needed.  相似文献   

13.
Deep inspiration breath hold (DIBH) is an effective technique to reduce cardiac and pulmonary dose during breast radiotherapy (RT). However, as a result of expense and the technical challenges of program implementation, DIBH has not been widely adopted in clinical practice.This report describes a program for DIBH this is relatively inexpensive to implement and has little impact on patient throughput. Multiple redundant mechanisms are incorporated to assure accurate and safe delivery of RT during DIBH. Laser alignment verifies that chest wall excursion is reliably reproduced and maintained during treatment. Chest wall excursion is also monitored independently using an infrared camera trained on a reflective marker on the chest wall. This system automatically triggers “beam off” in the event of movement of the target beyond pre-determined thresholds. Finally, physician review of cine imaging obtained during treatment provides an off-line verification of accurate RT delivery. The approach described herein lowers the investment necessary for implementation of DIBH and may facilitate broader adoption of this valuable technique.  相似文献   

14.
We report a simple gaseous sensor for the sensitive detection of trace 2‐propanol in exhaled breath using in situ enrichment and cataluminescence detection method on the surface of nanomaterials. The influences of heating voltage and absorption time on the CTL intensity were discussed, respectively. In the selected conditions, the linear range of 2‐propanol concentration is 60–600 ppbv and the detection of limit is 11 ppbv. Moreover, the lifetime and selectivity of the sensor were also investigated. It has the potential to diagnostic volatile organic compounds in human breath. Copyright © 2010 John Wiley & Sons, Ltd  相似文献   

15.
The metabolic phenotype varies widely due to external factors such as diet and gut microbiome composition, among others. Despite these temporal fluctuations, urine metabolite profiling studies have suggested that there are highly individual phenotypes that persist over extended periods of time. This hypothesis was tested by analyzing the exhaled breath of a group of subjects during nine days by mass spectrometry. Consistent with previous metabolomic studies based on urine, we conclude that individual signatures of breath composition exist. The confirmation of the existence of stable and specific breathprints may contribute to strengthen the inclusion of breath as a biofluid of choice in metabolomic studies. In addition, the fact that the method is rapid and totally non-invasive, yet individualized profiles can be tracked, makes it an appealing approach.  相似文献   

16.
Volatile breath constituents such as acetone and ammonia have been linked to dextrose, fat, and protein metabolism. Non-invasive breath analysis, therefore, may be used for metabolic monitoring, identification of fuel sources actually used for energy production and determination of the anaerobic threshold (AT). This study was intended to assess correlations between exhaled volatile organic compound (VOC) concentrations, metabolism, and physiological parameters. In addition, we tried to find out whether AT could be determined by means of non-invasive analysis of VOCs in breath. Exhaled concentrations of acetone, ammonia, and isoprene were determined in 21 healthy volunteers under controlled ergometric exercise by means of continuous real time Proton Transfer Reaction Mass Spectrometry (PTR-MS). In parallel, spiro-ergometric parameters ( $ {\dot{\text{V}}} $ O2, $ {\dot{\text{V}}} $ CO2, respiratory rate and minute ventilation) and hemodynamic data such as heart rate were recorded. AT was determined from serum lactate, by means of respiratory exchange rate and by means of exhaled acetone concentrations. Exhaled acetone concentrations mirrored exercise induced changes of dextrose metabolism and lipolysis. Bland?CAltman statistics showed good agreement between lactate threshold, respiratory compensation point (RCP), and determination of AT by means of exhaled acetone. Exhaled ammonia concentration seemed to be linked to protein metabolism and changes of pH under exercise. Isoprene concentrations showed a close correlation to cardiac output and minute ventilation. Breath biomarkers represent a promising alternative for metabolic monitoring under exercise as they can be determined non-invasively and continuously. In addition, these markers may add complementary information on biochemistry, energy production and fuel consumption.  相似文献   

17.
Effective management of diabetes mellitus, affecting tens of millions of patients, requires frequent assessment of plasma glucose. Patient compliance for sufficient testing is often reduced by the unpleasantness of current methodologies, which require blood samples and often cause pain and skin callusing. We propose that the analysis of volatile organic compounds (VOCs) in exhaled breath can be used as a novel, alternative, noninvasive means to monitor glycemia in these patients. Seventeen healthy (9 females and 8 males, 28.0 ± 1.0 yr) and eight type 1 diabetic (T1DM) volunteers (5 females and 3 males, 25.8 ± 1.7 yr) were enrolled in a 240-min triphasic intravenous dextrose infusion protocol (baseline, hyperglycemia, euglycemia-hyperinsulinemia). In T1DM patients, insulin was also administered (using differing protocols on 2 repeated visits to separate the effects of insulinemia on breath composition). Exhaled breath and room air samples were collected at 12 time points, and concentrations of ~100 VOCs were determined by gas chromatography and matched with direct plasma glucose measurements. Standard least squares regression was used on several subsets of exhaled gases to generate multilinear models to predict plasma glucose for each subject. Plasma glucose estimates based on two groups of four gases each (cluster A: acetone, methyl nitrate, ethanol, and ethyl benzene; cluster B: 2-pentyl nitrate, propane, methanol, and acetone) displayed very strong correlations with glucose concentrations (0.883 and 0.869 for clusters A and B, respectively) across nearly 300 measurements. Our study demonstrates the feasibility to accurately predict glycemia through exhaled breath analysis over a broad range of clinically relevant concentrations in both healthy and T1DM subjects.  相似文献   

18.

Background

The effects of changes in cooling temperature on biomarker levels in exhaled breath condensate have been little investigated. The aim of the study was to test the effect of condensation temperature on the parameters of exhaled breath condensate and the levels of selected biomarkers.

Methods

Exhaled breath condensate was collected from 24 healthy subjects at temperatures of -10, -5, 0 and +5 C degrees. Selected parameters (condensed volume and conductivity) and biomarkers (hydrogen peroxide, malondialdehyde) were measured.

Results

There was a progressive increase in hydrogen peroxide and malondialdehyde concentrations, and condensate conductivity as the cooling temperature increased; total condensate volume increased as the cooling temperature decreased.

Conclusion

The cooling temperature of exhaled breath condensate collection influenced selected biomarkers and potential normalizing factors (particularly conductivity) in different ways ex vivo. The temperature of exhaled breath condensate collection should be controlled and reported.  相似文献   

19.
This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the 'ECoScreen' in healthy calves (body weight 63-98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system 'ECoCheck'. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138-624 nmol l-1 EBC or 0.10-0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC-H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC-pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC-pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

20.
BACKGROUND: The nondispersive isotope-selective infrared spectroscopy (NDIRS) is a valid method for the measurement of the 13CO2:12CO2 ratio in breath samples. Methodical influences have to be considered to obtain valid results. AIM: To evaluate the effect of oxygen supply to patients on the measurement of 13C:12C ratio in breath samples by NDIRS. METHODS: Breath samples of 26 healthy volunteers were taken before, immediately after, and 5 minutes after inhalation of 100% oxygen via a continuous positive air pressure (CPAP) mask. Analysis of breath samples was performed by NDIRS. RESULTS: Delta per thousand before oxygen inhalation was -25.8 +/- 0.2. Immediately after 5 minutes of 100% oxygen inhalation, delta per thousand increased to -14.8 +/- 0.5 (delta over baseline [DOB] 11.0 +/- 0.4) and after additional 5 minutes of room air inhalation, delta per thousand normalized to -25.6 +/- 0.2 (DOB 0.2 +/- 0.1). CONCLUSIONS: Oxygen supply to patients and, therefore, changes in gas composition in breath samples clearly influence 13CO2 measurement by NDIRS. This has to be taken into account in the clinical setting. Thus, oxygen supply during measurement of exhaled 13CO2 by NDIRS has to be avoided or maintained at a strictly constant level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号