首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Radiofrequency catheter ablations of anteroseptal (AS) accessory pathways (AP) in pediatric patients have higher incidence of atrioventricular (AV) block than other AP locations. We report our experience using cryoablation in pediatric patients where a His bundle electrogram was noted on the ablation catheter at the site of the successful ablation.

Methods and Results

We retrospectively reviewed all patients ≤21 years that underwent cryoablation for an AS AP from 2005 to 2012 at our institution (n=70). Patients with a His bundle electrogram noted on the cryoablation catheter at the location of the successful lesion were identified (n=6, 8.5%). All six patients had ventricular preexcitation. Median age of 15.9 years (7.2 - 18.2). AV nodal function was monitored during the cryoablation with intermittent rapid atrial pacing conducted through the AV node (n=2), with atrial extra-stimulus testing (n=2), or during orthodromic reentrant tachycardia (n=2). Acute success occurred in all patients. Two patients had early recurrence of AP conduction. Both patients underwent a second successful cryoablation, again with a His bundle electrogram on the cryoablation catheter. At a median follow-up of 13 months (3 to 37 months) there was no recurrence of accessory pathway conduction and AVN function was normal.

Conclusion

In a small number of pediatric patients with AS AP with a His bundle electrogram seen on the ablation catheter, the use of cryotherapy was safe and effective for elimination of AP conduction without impairment of AV nodal conduction.  相似文献   

2.
IntroductionCommon clinical teaching, for invasive electrophysiology, is that if the first year fellow cannulates the coronary sinus (CS) in his first attempt, the arrhythmia is more likely to be atrioventricular nodal reentry tachycardia (AVNRT). This general perception has not yet been clinically tested. We evaluated this theory in prospective patients undergoing an electrophysiological study (EPS) for paroxysmal supraventricular tachycardia (PSVT).MethodsCohort study. CS ease of cannulation (CSCS) was graded as: 1) 1st year fellow cannulates in first attempt; 2) 1st year fellow needs more than one attempt or maneuver to cannulate the CS; 3) staff physician cannulates in first attempt after the fellow was unsuccessful; 4) staff physician requires more than one maneuver to cannulate the CS; 5) staff physician judges that the cannulation process was extremely difficult.ResultsOf the 1361 patients undergoing EPS in our institution, 165 were selected. Age was 49 ± 15 years. AVNRT occurred in 77.6%, atrioventricular reentry tachycardia (AVRT) in 15.1% and atrial tachycardia (AT) in 7.3% of cases. The CSCS = 1 was more prevalent in AVNRT, 89% versus 68% AVRT and 58.3% of AT (P = 0.0005). Patients with CSCS = 1 have a higher chance of the PSVT being AVNRT (odds ratio: 4.41; 95CI: 1.84–10.56; P = 0.0009).ConclusionThe CSCS predicts the likelihood of the induced PSVT being AVNRT as compared to AVRT and AT. More studies are required to try to associate this finding to clinical patient characteristics to create a score for PSVT mechanism prediction.  相似文献   

3.
A 74-year old was considered for atrioventricular (AV) nodal ablation in view of atrial fibrillation (AF) with poorly controlled ventricular rate despite being on amiodarone. Targeted AV nodal ablation was successfully performed after identifying the target site for ablation by reviewing an ultra high-density map of the His region produced by automatic electrogram annotation.Key words: His bundle, atrioventricular node, cardiac mapping, catheter ablation  相似文献   

4.
BackgroundMapping of cardiac electrical activity can be difficult when electrogram morphology is complex. Complex morphology (multiple and changing deflections) causes activation maps to vary when constructed by different analysts, particularly at areas with spatially varying conduction pattern. An algorithm was developed to automatically detect electrogram activation time which is robust to complex morphology.MethodElectrograms, many of which were complex, were collected from 320 canine epicardial border zone sites in five experiments. A library of electrogram activation times were manually marked a priori by two expert analysts. Then an algorithm which combined correlation and error functions was used to compare each input electrogram to library electrogram patterns. The closest match of input to library electrogram was used to estimate activation time. Once activation times at 320 sites were determined, activation maps were automatically constructed on a computerized grid. The algorithm was validated by comparison with activation times determined by the analysts.ResultsThe mean difference between manual and automated marking of activation time in electrograms acquired during reentrant ventricular tachycardia was 2.1 ± 3.9 ms. The mean sensitivity and positive predictive value were 95.9% and 83.8% respectively. The computer-automated marking process was completed within a few seconds and was robust to fractionated electrograms. Measurement error was mostly attributable to 60 Hz noise, which can be rectified with filtering.ConclusionsThe automated algorithm is useful for rapid and accurate automatic marking of multichannel electrograms, some of which may be fractionated, as well as for real-time display of activation maps in clinical electrophysiology or research studies.  相似文献   

5.
BackgroundCryoablation for atrioventricular nodal reentrant tachycardia (AVNRT) is effective and safe with a reported limitation of lower success and higher recurrence rates. We have observed cases in which slow pathway conduction was eliminated as demonstrated by atrial extra-stimulus testing within 1 min of cryo-energy delivery but returned following tissue rewarming. Frequently, slow pathway conduction persisted despite multiple acutely successful lesions over a broad anatomic region. We aimed to determine if return of slow pathway conduction after elimination during cryoablation represents a risk for recurrent AVNRT with the same intermediate term results as slow pathway ablation. We hypothesize that remnant single echo beats in the absence of sustained slow pathway conduction and inducible AVNRT is an acceptable end point after clear slow pathway elimination during cryoablation.MethodsRetrospective chart review of patients undergoing attempted slow pathway ablation for AVNRT using solely cryoablation between January 2015–January 2018.ResultsForty-four patients met inclusion criteria with at-least 2 features of dual AVN physiology. 19 patients had return of slow pathway conduction shortly after clear elimination during cryoablation (Group A) while 25 did not (Group B). All in Group A had recurrent single echo beats but none had sustained slow pathway conduction at the end of the procedure nor AVNRT recurrence at 1 year.ConclusionRecurrent single echo beats with absent sustained slow pathway conduction and non-inducible AVNRT may be an acceptable endpoint for slow pathway ablation of AVNRT using cryoablation when there is elimination of slow pathway demonstrated during energy delivery.  相似文献   

6.
BackgroundVoltage mapping is critical to define substrate during ablation. In ventricular tachycardia, abnormal potentials may be targets. However, wavefront of activation could impact local signal characteristics. This may be particularly true when comparing sinus rhythm versus paced rhythms. We sought to determine how activation wavefront impacts electrogram characteristics.MethodsPatients with ischemic cardiomyopathy, ventricular tachycardia, and without fascicular or bundle branch block were included. Point by point mapping was done and at each point, one was obtained during an atrial paced rhythm and one during a right ventricular paced rhythm. Signals were adjudicated after ablation to define late potentials, fractionated potentials, and quantify local voltage. Areas of abnormal voltage (defined as <1.5 mV) were also determined.Results9 patients were included (age 61.3 ± 9.2 years, 56% male, mean LVEF 34.9 ± 8.6%). LV endocardium was mapped with an average 375 ± 53 points/rhythm. Late potentials were more frequent during right ventricular pacing (51 ± 21 versus 32 ± 15, p < 0.01) while overall scar area was higher during atrial pacing (22 ± 11% vs 13 ± 7%, p < 0.05). In 1/9 patients, abnormal potentials were seen during a right ventricular paced rhythm that were not apparent in an atrial paced rhythm, ablation of which resulted in non-inducibility.ConclusionRhythm in which mapping is performed has an impact on electrogram characteristics. Whether one rhythm is preferable to map in remains to be determined. However, it is possible defining local signals during normal conduction as well as variable paced rhythms may impart a greater likelihood of elucidating arrhythmogenic substrate.  相似文献   

7.
A 60-year-old man presented with sustained supraventricular tachycardia. Atrial tachycardia (AT), with the earliest atrial activation (EAA) occurring at the ostium of the coronary sinus, was reproducibly induced.Three-dimensional electroanatomical mapping (3DEAM) using a 3.5-mm distal electrode tip linear catheter (Thermocool) and radiofrequency energy (RF) was performed at the fractionated atrial electrogram site. It preceded at 30 ms to the EAA but did not terminate AT. Further 3DEAM using a multielectrode mapping catheter (Pentaray) demonstrated a centrifugal propagation pattern at the boundary zone between the right atrium and inferior vena cava. RF application here terminated AT, which then became non-inducible.  相似文献   

8.
IntroductionIntraprocedural coronary angiography is recommeded in patients undergoing ablation in aortic cusps to assess the relation of catheter tip and coronary ostia. In this report, we present our experience in selective coronary angiography through the radiofrequency catheter during premature ventricular contraction (PVC) ablation.Methods and resultsWe prospectively recruited 43 consecutive patients who underwent PVC ablation in the aortic cusps between March 2018 and April 2021. We performed coronary angiography through the contact force (CF)-sensing ablation catheter at the ablation site. Successful ablation was achieved in 38 (88%) of patients. No technical problems occurred after the contrast injection and ablation parameters were within the normal values, without any change of impedance and CF-sensing values and neither electrogram signal quality after contrast injection. No complications occurred during the procedure, hospital stay, and during one-year follow-up (15.3 ± 3.1 months).ConclusionSelective coronary angiography through the CF-sensing ablation catheter to assess the relation between the ablation site and the coronary ostia is feasible and no minor or major complications occurred in our experience.  相似文献   

9.
IntroductionAblating the slow pathway (SP) is the superior treatment for atrioventricular nodal reentrant tachycardia (AVNRT) with a low complication rate. However, the ablation of the SP could result in either complete elimination or modification of the SP. We aimed to investigate whether the duration of AH jump pre-ablation associated with the outcome of elimination of SP.MethodsWe included 56 patients with typical AVNRT (slow-fast), 20 males and 36 females, aged 44.2 ± 15.1 years. Slow pathway ablation was performed using classical approach. Univariate and multivariate analysis was performed for potential predictors of SP elimination.ResultsTypical AVNRT was inducible in all patients. Post-ablation, non-inducibility of AVNRT was obtained in all 56 (100%) patients, with SP elimination in 33 (61%) patients and SP modification in 23 (39%) patients. Patients with SP elimination had significantly longer AH jump than patients with SP modification. Cox regression analysis showed that AH jump duration was the independent predictor of SP elimination, in which every 20 ms increase in AH jump duration was associated with 1.30 higher rate of SP elimination. Furthermore, ROC curve analysis indicated that the AH jump duration of ≥100 ms had 6.14 times higher probability for complete elimination of the SP with a sensitivity of 79%, specificity of 70%, PPV of 79% and NPV of 70%.ConclusionsAH jump duration pre-ablation is associated with complete elimination of slow pathway during AVNRT ablation.  相似文献   

10.
BackgroundOesophageal changes and injuries were recorded after atrial fibrillation(AF) ablation procedures. The reduction of power in the posterior left atrial(LA) wall(closest to the oesophagus) and the monitoring of temperature in the oesophagus(OE) reduced oesophageal injuries. The intracardiac-echocardiography(ICE) with a Cartosound module provides two-dimensional imaging (2D) to assess detailed cardiac anatomy and its relationship with the OE. The aim of this study was to highlight the safety and feasibility of 3D-reconstruction of the oesophageal course in left atrial catheter ablation(CA) procedures without OE temperature probe or quadripolar catheter to guide ICE OE reconstruction.Methods180 patients(PT) underwent left atrial ablation. AF ablation were 125(69.5%); incisional left atrial tachycardias(IAFL) were 37(20.6%); left atrial tachycardias(LAT) were 19(10.6%). The LA and pulmonary vein anatomies were rendered by traditional electroanatomic mapping(EAM) and merged with an ICE anatomic map. In 109 PT ICE imaging was used to create a geometry of the OE(group A). A quadripolar catheter was used in 71 PT to show OE course associated to ICE(group B).ResultsAblation energy delivery was performed outside the broadest OE anatomy borders. The duration of procedures was longer in group B vs group A Fluoroscopy time was lower in Group A than Group B(Group A 7 ± 3.2 vs 19.2 ± 2.4 min; p < 0.01).ConclusionsOE monitoring with ICE is safe and feasible. Oesophageal anatomy is complex and variable. Many PT will have a broad oesophageal boundary, which increases the risk of untoward thermal injury during posterior LA ablation. ICE with 3D construction of the OE enhances border detection of the OE, and as such, should decrease the risk of oesophageal injury by improving avoidance strategies without intra-oesophageal catheter visualization.  相似文献   

11.
BackgroundLeft-sided ablation, targeting left inferior AV nodal extensions, is thought to be necessary for success in a small proportion of atrioventricular nodal re-entrant tachycardia (AVNRT) ablations; however Indian data are scarce in this regard.MethodsConsecutive cases of AVNRT undergoing slow pathway ablation in a single centre over an 18-month period were retrospectively analyzed. Left-sided ablation at the posteroseptal mitral annulus was performed if right-sided ablation failed to abolish AVNRT.ResultsFrom January 2017 to June 2018, out of 215 consecutive supraventricular tachycardia (SVT) cases, 154 (71.6%) were AVNRT (47.1 ± 13.1 years, 46.1% male). Trans-septal ablation was required in 5 (3.2%) cases (mean age 48.8 ± 9.4 years; 4 female, 1 male); all with typical (slow-fast) form of AVNRT. Compared with cases needing only right-sided ablation, radiofrequency time (50.8 ± 16.9 vs. 9.9 ± 8.5 min; p = 0.005) and procedure time (166.0 ± 35.0 vs 79.6 ± 35.9 min; p = 0.004) were significantly longer for trans-septal cases, while baseline intervals and tachycardia cycle length were not significantly different. Junctional ectopy was seen in only 2 of the 5 cases during left-sided ablation, but acute success (non-inducibility) was obtained in 3 cases. There were no instances of AV block. Over mean follow-up of 12.2 ± 4.0 months, clinical recurrence of AVNRT occurred in one case, while others remained arrhythmia-free without medication.ConclusionLeft-sided ablation was required in a small proportion of AVNRT ablations. Trans-septal approach targeting the posteroseptal mitral annulus was safe and yielded good mid-term clinical success.  相似文献   

12.
33 year old gentleman has undergone an electrophysiology study for recurrent paroxysmal palpitation. During one of the episodes of palpitation a regular narrow QRS tachycardia was documented which has terminated with intravenous adenosine. Baseline electrocardiogram did not show any pre-excitation. Atrial-His (AH) and His-Ventricular (HV) intervals were normal at baseline. There was no evidence of dual atrioventricular (AV) nodal physiology. Earliest atrial electrogram during ventricular pacing was recorded at coronary sinus (CS) 9,10 dipoles placed at CS OS region. Narrow QRS tachycardia with cycle length (TCL) of 400 ms and earliest retrograde atrial activation at CS 9,10 dipoles was induced with programmed ventricular stimulation. Ventricular overdrive (VOD) pacing was performed at 30 ms shorter than TCL during the tachycardia (Fig: 1). What is the mechanism of tachycardia?  相似文献   

13.

The hydrophobic fractionation of extracellular polymeric substances (EPS) extracted from anaerobic granular sludge was performed on the DAX-8 resin (two elution pH conditions, i.e., pH 2 and pH 5 were tested). The impact of seven different EPS extraction methods on EPS hydrophobicity features was assessed. The results showed that the extraction methods and bulk solution pH influenced dramatically the biochemical composition of the EPS, and in turn, the hydrophobicity determined. Besides, EPS extracting reagents i.e., formaldehyde, ethanol, sodium dodecyl sulfate (SDS), and Tween 20 not only introduced extra carbon content in the total organic carbon (TOC) measurement but also interacted with the DAX-8 resin. By comparing the apparent molecular weight (aMW) distribution of untreated and pH-adjusted EPS samples, more complete EPS aMW information was preserved at pH 5. Thus, elution at pH 5 was preferred in this study for the qualitative analysis of EPS hydrophobic features. The hydrophobic fraction of EPS retained by the resin at pH 5 was ascribed to a wide aMW range, ranging from >440 to 0.3 kDa. Within this range, EPS molecules ranging from 175 to 31 kDa were mostly retained by the DAX-8 resin, which indicates that these EPS molecules are highly hydrophobic.

  相似文献   

14.
BackgroundSecond-generation cryoballoon ablation is safe and effective in patients with paroxysmal (PAF) and persistent atrial fibrillation (AF).ObjectiveThis study aimed to assess the long-term clinical outcomes and freedom from AF in patients undergoing thermal-guided cryoablation without the use of an electrical mapping catheter.MethodsAll patients who had undergone thermal-guided second-generation cryoablation without electrical mapping between January 2015 and April 2018 at Eastbourne District General Hospital were retrospectively analysed. Success was defined as freedom from atrial arrhythmia lasting >30 s during the follow up period.ResultsThe study included 234 patients with a mean age of 65.3 ± 10.6 years. There were 134 (57.0%) and 100 (42.7%) patients who had PAF and persistent AF respectively.Arrhythmia recurrence occurred in 38 of 134 (28.4%) PAF and 42 of 100 (42.0%) persistent AF patients after mean follow up of 40 ± 9.2 months. The patients with PAF had a significantly greater freedom from arrhythmia than patients with persistent AF (p = .040). The mean procedure time was 55.5 ± 12.2 min and the mean fluoroscopy time was 10.9 ± 4.8 min 73.5% of patients were discharged on the same day.ConclusionThermal-guided cryoablation is feasible, safe and results in freedom from arrhythmia in the majority of paroxysmal and persistent AF patients in the long term. Randomised controlled trials are required to confirm the findings of this study.  相似文献   

15.
BackgroundHigh-power short-duration (HPSD) and cryoballoon ablation (CBA) has been used for pulmonary vein isolation (PVI).ObjectiveWe aimed to compare the efficacy of PVI between CBA and HPSD ablation in patients with paroxysmal atrial fibrillation (PAF).MethodsWe retrospectively analyzed 251 consecutive PAF patients from January 2018 to July 2020. Of them, 124 patients (mean age 57.2 ± 10.1 year) received HPSD and 127 patients (mean age 59.6 ± 9.4 year) received CBA. In HPSD group, the radiofrequency energy was set as 50 W/10 s at anterior wall and 40 W/10 s at posterior wall. In CBA group, 28 mm s generation cryoballoon was used for PVI according the guidelines.ResultsThere was no significant difference in baseline characteristics between these 2 groups. The time to achieve PVI was significantly shorter in cryoballoon ablation group than in HPSD group (20.6 ± 1.7 min vs 51.8 ± 36.3, P = 0.001). The 6-month overall recurrence for atrial tachyarrhythmias was not significantly different between the two groups (HPSD:14.50% vs CBA:11.0%, P = 0.40). There were different types of recurrent atrial tachyarrhythmia between these 2 groups. Recurrence as atrial flutter was significantly more common in CBA group compared to HPSD group (57.1% vs 12.5%, P = 0.04).ConclusionIn PAF patients, CBA and HPSD had a favourable and comparable outcome. The recurrence pattern was different between CBA and HPSD groups.  相似文献   

16.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   

17.
IntroductionConflicting results regarding the impact of left common pulmonary vein (LCPV) on clinical outcome of atrial fibrillation (AF) ablation with cryoballoon technology have been reported.MethodsWe systematically searched PubMed and Cochrane library for articles that compared the arrhythmia recurrence rate after cryoballoon ablation between patients with normal pattern PVs and patients with LCPV. Studies of first ablation for persistent and paroxysmal AF using the 28 mm Arctic Front Advance, Medtronic cryoballoon (CB-A) reporting clinical success rates at a mean follow-up of ≥12 months were included. Data were analyzed by applying a random effects model.ResultsA total of 5 studies with a total of 1178 patients met our predefined inclusion criteria. After a mean follow-up of 18.4 months, the overall success rate of CB-A ablation among patients with persistent and paroxysmal AF was 57%; in the LCPV group the success rate was 46% and in the normal anatomical pattern group it was 61%. No significant heterogeneity was noted among the studies (I2 = 35.8%; Q (df = 3) = 6.23 p-value = 0.18). Arrhythmia recurrence after CB-A ablation was not statistically significant between the two groups (LogOR 0.24; 95% CI [-0.16-0.63]; p-value = 0.23). No significant difference in PNI was observed between the two groups (p-value = 0.693).ConclusionThe presence of LCPV does not affect the long-term outcome of paroxysmal and persistent atrial fibrillation ablation with 28 mm CB-A compared to normal left PVs pattern.  相似文献   

18.
BackgroundIn early luminal breast cancer, the Oncotype DX® Recurrence Score (RS) prognostic and predictive value with regards to chemotherapy (CHT) application benefit has been broadly validated. In older patients its value has not been deeply addressed. This study aimed to evaluate the benefits of RS testing and to look at differences in treatment allocation for these patients when compared with younger ones.MethodsWe included data from consecutive patients with early luminal HER2-negative breast cancer, treated between 2010 and 2022 at the University Hospital Basel and Cantonal Hospital Baselland, Switzerland. The older cohort included 63 (19%) patients aged ≥70, and the younger cohort 263 (81%) patients aged <70.ResultsOlder breast cancer patients had more co-morbidities (N = 36, 57% vs. N = 92, 35%, p = 0.002) and a higher clinical risk status (N = 49, 78% vs. N = 155, 59%; p = 0.01) when compared to younger patients. Histopathologic characteristics were significantly different between the two cohorts. Although older patients had a higher clinical risk status (78% vs. 59%) (p = 0.01), most of them (74%) received no CHT. Specifically, adjuvant CHT was administered less frequently in older than in younger patients (13% vs. 22%; p = 0.01). Moreover, older patients were less likely to complete CHT (>4 cycles: 78% vs. 97%).ConclusionBreast cancer patients aged ≥70 have higher clinical risk status, more co-morbidities, higher clinical stage (driven by larger tumor size), and more often RS ≥26. However, they receive fewer adjuvant RT and CHT than those aged <70. RS maintains its independent prognostic value in older patients. However, assessing the predictive value of additional CHT benefit remains challenging due to significant differences in CHT administration. Although therapy decision-making in older patients with breast cancer still follows RS-based guidelines, clinical practice indicates an individualized treatment approach.  相似文献   

19.
20.
IntroductionAim of this study was to evaluate efficacy and safety of ventricular tachycardia (VT) catheter ablation in patients with structural heart disease (SHD) in relation to the presence of an intramural septal substrate.MethodsConsecutive patients undergoing VT ablation between January 2019 and October 2020 were included. All patients were stratified based on the presence of relevant septal substrate and freedom from VT recurrences were analyzed.ResultsIn total, 199 consecutive patients (64.2 ± 13.0 years; 89% male; 55% ischemic cardiomyopathy (ICM)) undergoing VT ablation were included. 129/199 patients (65%) showed significant septal substrate (55/90 patients (61%) with non-ischemic cardiomyopathy (NICM) compared to 74/109 patients (68%) with ICM; p = 0.37). Acute procedural success with elimination of all inducible VTs was achieved in 66/70 patients (94%) without and in 103/129 patients (80%) with a septal substrate (p = 0.007). In the cohort including patients with a clinical FU, 15/60 patients (25%) without a septal substrate and 48/123 patients (39%) with a septal substrate experienced VT recurrence during a FU of 8.1 ± 5.9 months (p = 0.069).ConclusionPresence of septal VT substrate in patients with a structural heart disease or coronary artery disease is common. Acute success of VT catheter ablation was significantly higher and mid-term success tended to be higher in patients without a septal substrate.  相似文献   