首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Recent reports have described the incidence of atrioesophageal fistulas (AEF), often resulting in death, from radiofrequency (RF) catheter ablation of atrial fibrillation (AF).1 Cases of esophageal perforation without concomitant AEF have not been described as extensively.1 The precise mechanisms leading to esophageal injury after catheter ablation without involvement of the left atrium are not fully understood. The surgical approach to treat esophageal perforation is strongly recommended.2 However, a unified surgical treatment approach has not yet been established. We describe a case of successful surgical repair of an esophageal perforation after ablation using surgical repair in combination with an omental wrap.  相似文献   

3.
黄浩  孙毅勇 《生物信息学》2019,17(2):102-110
为了进一步探究房颤患者心内不同位置信号的主导频率(Dominant frequency,简称DF)的关联性,本文对传统的Botteron’s算法进行了改进。当信号中含有较大幅值的室波时,该改进算法可以更好地提取DF。利用该算法对20例临床房颤消融手术的冠状静脉窦(Coronary sinus,简称CS)导管、环肺静脉(Pulmonary veins,简称PV)导管采集的信号进行了观察和分析。在大部分病例中都能观察到其CS和PV的信号里都存在相同频率的DF;同时发现CS的DF并不仅仅来自当前标测的PV。实验结果表明:房颤的潜在病灶区域不仅仅具有较高频率的DF,且其DF的频率应当与心房采集的DF频率存在对应关系。这或许可以为寻找房颤的潜在病灶区域提供参考。  相似文献   

4.
BackgroundCurrently, cryoballoon (CB) thawing after single stop is generally performed. Previous research had reported that long thawing time using a single stop affects pulmonary veins tissue injury. However, it is uncertain whether CB thawing after single stop affects clinical outcomes.ObjectiveThis study aimed to clarify clinical significance of CB thawing in patients with paroxysmal atrial fibrillation.MethodsTwo hundred ten patients with paroxysmal atrial fibrillation who underwent CB from January 2018 to October 2019 were analyzed. We compared the clinical outcomes of patients whose CB applications were completely stopped with only the double stop technique (DS group, n = 99) and patients with single stop (SS group, n = 111). In DS group, we performed double stop technique for all CB application regardless of phrenic nerve injury or the temperature of esophagus.ResultsThe atrial arrhythmia free-survival rate at 2 years after CB was significantly lower for the DS group than the SS group (76.8% vs 87.4%; p = 0.045). Complications occurred in 2 patients from the DS group and no complications were observed in patients from the SS group (p = 0.13). Mean procedural time was shorter in the DS group than in the SS group (53.1 vs 58.1 min; p = 0.046)ConclusionDS group had higher recurrence rate than SS group. There was no significant difference regarding safety between both the groups. We found that the thawing process after single stop is very important for CB application.  相似文献   

5.
IntroductionThe AcQMap High Resolution Imaging and Mapping System was recently introduced. This system provides 3D maps of electrical activation across an ultrasound-acquired atrial surface.MethodsWe evaluated the feasibility and the acute and short-term efficacy and safety of this novel system for ablation of persistent atrial fibrillation (AF) and atypical atrial flutter.ResultsA total of 21 consecutive patients (age (mean ± standard deviation) 62 ± 8 years, 23% female) underwent catheter ablation with the use of the AcQMap System. Fourteen patients (67%) were treated for persistent AF and 7 patients (33%) for atypical atrial flutter. Eighteen patients (86%) had undergone at least one prior ablation procedure. Acute success, defined as sinus rhythm without the ability to provoke the clinical arrhythmia, was achieved in 17 patients (81%). At 12 months, 4 patients treated for persistent AF (29%) and 4 patients treated for atypical flutter (57%) remained in sinus rhythm. Complications included hemiparesis, for which intra-arterial thrombolysis was given with subsequent good clinical outcome (n = 1), and complete atrioventricular block, for which a permanent pacemaker was implanted (n = 2). No major complications attributable to the mapping system occurred.ConclusionThe AcQMap System is able to provide fast, high-resolution activation maps of persistent AF and atypical atrial flutter. Despite a high acute success rate, the recurrence rate of persistent AF was relatively high. This may be due to the selection of the patients with therapy-resistant arrhythmias and limited experience in the optimal use of this mapping system that is still under development.Supplementary InformationThe online version of this article (10.1007/s12471-021-01636-w) contains supplementary material, which is available to authorized users.  相似文献   

6.
BackgroundThere are limited data describing the experience of radiofrequency (RF) vs. cryoballoon (CB) ablation for atrial fibrillation (AF) among elderly patients in the United States.MethodsWe conducted a retrospective analysis of patients ≥75 years of age undergoing index RF vs. CB ablation between January 2014 and May 2020 at our center. The choice of ablation technique was left to the operator's discretion. Major complications and efficacy, defined as freedom from any atrial tachyarrhythmia (ATA) lasting ≥30 s after one year of follow-up, were assessed in patients with index RF vs. CB ablation.ResultsIn our cohort of 186 patients, the median age was 78 (76–81) years, 54.8% were men, and 39.2% had persistent AF. The median CHA2DS2-VASc score was 4 (3–4), while the median duration of AF was 3 (1–7) years. The majority (n = 112, 60.2%) underwent RF ablation. The median procedure time was significantly lower in CB group (197 vs 226.5 min, p=<0.01). The incidence of complications was similar in the two sub-groups (RF: 1.8% vs. CB: 2.7%, p = 0.67). Similarly, arrhythmia-free survival rate on antiarrhythmic drugs at 1-year follow-up remained statistically comparable (63.4% vs. 68.9%, p = 0.33) between patients receiving RF vs. CB ablation.ConclusionThe safety and efficacy of RF vs. CB ablation for AF remained comparable in our cohort of patients older than 75 years. CB ablation was associated with a shorter procedure time.  相似文献   

7.
IntroductionProspective studies on rivaroxaban and apixaban have shown the safety and efficacy of direct anticoagulation agents (DOAC)s used peri-procedurally during radiofrequency ablation (RFA) of atrial fibrillation (AF). Studies comparing the two agents have not been performed.MethodsConsecutive patients from a prospective registry who underwent RFA of AF between April 2012 and March 2015 and were on apixaban or rivaroxaban were studied. Clinical variables and outcomes were noted.ResultsThere were a total of 358 patients (n = 56 on apixaban and n = 302 on rivaroxaban). There were no differences in baseline characteristics between both groups. The last dose of rivaroxaban was administered the night before the procedure in 96% of patients. In patients on apixaban, 48% of patients whose procedure was in the afternoon took the medication on the morning of the procedure. TIA/CVA occurred in 2 patients (0.6%) in rivaroxaban group with none in apixaban group (p = 0.4). There was no difference in the rate of pericardial effusion between apixaban and rivaroxaban groups [1.7% vs 0.6% (p = 0.4)]. Five percent of patients in both groups had groin complications (p = 0.9). In apixaban group, all groin complications were small hematomas except one patient who had a pseudoaneurysm (1.6%). One pseudo-aneurysm, 1 fistula and 3 large hematomas were noted in patients on rivaroxaban (1.7%) with the rest being small hematomas. DOACs were restarted post procedure typically 4 h post hemostasis.ConclusionsPeri-procedural uninterrupted use of apixaban and rivaroxaban during AF RFA is safe and there are no major differences between both groups.  相似文献   

8.
The Wnt signaling pathway regulates physiological processes such as cell proliferation and differentiation, cell fate decisions, and stem cell maintenance and, thus, plays essential roles in embryonic development, but also in adult tissue homeostasis and repair. The Wnt signaling pathway has been associated with heart development and repair and has been shown to be crucially involved in proliferation and differentiation of progenitor cells into cardiomyocytes. The investigation of the role of the Wnt signaling pathway and the regulation of its expression/activity in atrial fibrillation has only just begun. The present minireview (I) provides original data regarding the expression of Wnt signaling components in atrial tissue of patients with atrial fibrillation or sinus rhythm and (II) summarizes the current state of knowledge of the regulation of Wnt signaling components’ expression/activity and the contribution of the various levels of the Wnt signal transduction pathway to the processes of the development, maintenance, and progression of atrial fibrillation.  相似文献   

9.

Objective

To assess the outcome and associated risks of atrial defragmentation for the treatment of long-standing persistent atrial fibrillation (LSP-AF).

Methods

Thirty-seven consecutive patients (60.4 ± 7.3 years; 28 male) suffering from LSP-AF who underwent pulmonary vein isolation (PVI) and linear ablation were compared. All patients were treated with the Stereotaxis magnetic navigation system (MNS). Two groups were distinguished: patients with (n = 20) and without (n = 17) defragmentation. The primary endpoint of the study was freedom of AF after 12 months. Secondary endpoints were AF termination, procedure time, fluoroscopy time and procedural complications. Complications were divided into two groups: major (infarction, stroke, major bleeding and tamponade) and minor (fever, pericarditis and inguinal haematoma).

Results

No difference was seen in freedom of AF between the defragmentation and the non-defragmentation group (56.2 % vs. 40.0 %, P = 0.344). Procedure times in the defragmentation group were longer; no differences in fluoroscopy times were observed. No major complications occurred. A higher number of minor complications occurred in the defragmentation group (45.0 % vs. 5.9 %, P = 0.009). Mean hospital stay was comparable (4.7 ± 2.2 vs. 3.4 ± 0.8 days, P = 0.06).

Conclusion

Our study suggests that complete defragmentation using MNS is associated with a higher number of minor complications and longer procedure times and thus compromises efficiency without improving efficacy.  相似文献   

10.
11.

Background

Obesity is an important risk factor for atrial fibrillation (AF). Leptin is an important adipokine. However, it is not clear whether leptin directly modulates the electrophysiological characteristics of atrial myocytes.

Results

Whole cell patch clamp and indo-1 fluorescence were used to record the action potentials (APs) and ionic currents in isolated rabbit left atrial (LA) myocytes incubated with and without (control) leptin (100 nM) for 1 h to investigate the role of leptin on atrial electrophysiology. Leptin-treated LA myocytes (n = 19) had longer 20% of AP duration (28 ± 3 vs. 21 ± 2 ms, p < 0.05), but similar 50% of AP duration (51 ± 4 vs. 50 ± 3 ms, p > 0.05), and 90% of AP duration (89 ± 5 vs. 94 ± 4 ms, p > 0.05), as compared to the control (n = 22). In the presence of isoproterenol (10 nM), leptin-treated LA myocytes (n = 21) showed a lower incidence (19% vs. 54.2%, p < 0.05) of delayed afterdepolarization (DAD) than the control (n = 24). Leptin-treated LA myocytes showed a larger sodium current, but a smaller ultra-rapid delayed rectifier potassium current, and sodium-calcium exchanger current than the control. Leptin-treated and control LA myocytes exhibited a similar late sodium current, inward rectifier potassium current, transient outward current and L-type calcium current. In addition, the leptin-treated LA myocytes (n = 38) exhibited a smaller intracellular Ca2+ transient (0.21 ± 0.01 vs. 0.26 ± 0.01 R410/485, p < 0.05) and sarcoplasmic reticulum Ca2+ content (0.35 ± 0.02 vs. 0.43 ± 0.03 R410/485, p < 0.05) than the control LA myocytes (n = 42).

Conclusions

Leptin regulates the LA electrophysiological characteristics and attenuates isoproterenol-induced arrhythmogenesis.  相似文献   

12.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

13.

Objective

Reconduction across an ablation line is a common reason for arrhythmia recurrence over time. The hybrid procedure combines epicardial ablation of the pulmonary vein (PV) and creation of a box lesion with endocardial touch-ups for any electrical gaps. A high contact force (CF) between the ablation tip and cardiac tissue may increase the risk of thrombus formation, catheter tip charring, steam pop formation, and even cardiac perforation. CF monitoring is a significant new parameter for titration of the CF for creating an adequate lesion.

Methods

Thirty-eight consecutive patients underwent epicardial ablation using bipolar radiofrequency devices. After checking electrical bidirectional block of the ablation lines, an endocardial CF catheter was used for further ablation (if needed) to complete the isolation of PVs, box lesion, cavotricuspid isthmus (CTI), and complex fractionated atrial electrograms (CFAE).

Results

Endocardial touch-up was needed for 2 PVs (1.3 %) and 10 (26.3 %) box lesions. It was also used for the CTI line in 7 (18.4 %) patients, atrial tachycardia in 3 (7.9 %) patients, and additional CFAE ablation in 17 (44.7 %) patients. All 5 patients with arrhythmia recurrence had a mean CF < 10 g (p = 0.03). Procedure duration was significantly shorter in the CF group (223 ± 57 vs. 256 ± 60 min, p = 0.03) compared with control group.

Conclusion

Use of CF catheters is safe, feasible, and complementary to a hybrid procedure setup for atrial fibrillation ablation. Its real-time monitoring may predict future arrhythmia recurrence, and decrease procedure time.  相似文献   

14.
IntroductionThe endoscopic laser balloon ablation system (EAS) is a relatively novel technique to perform pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF). The present study aimed to report the results of the first 50 patients treated in the Netherlands with the EAS in terms of procedural characteristics and AF-free survival.MethodsFifty patients successfully underwent EAS PVI. Median follow-up was 17 months. Mean age was 56 years, 82 % had paroxysmal AF.Results99 % of the pulmonary veins were successfully isolated with the EAS. Mean procedure time was 171 min and mean fluoroscopy time was 36 min. One procedure was complicated by a temporary phrenic nerve palsy (2 %). During follow-up, 58 % of patients remained free of AF without the use of antiarrhythmic drugs.ConclusionPVI with EAS is associated with a low risk of complications and a medium-term AF-free survival comparable with other PVI techniques.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-014-0624-y) contains supplementary material, which is available to authorized users.  相似文献   

15.
Convergent atrial fibrillation ablation involves extensive epicardial as well as endocardial ablation of the left atrium. We examined whether it changes the morphology of the surface P wave. We reviewed electrocardiograms of 29 patients who underwent convergent ablation for atrial fibrillation. In leads V1, II and III, we measured P wave duration, area and amplitude before ablation, and at 1, 3 and 6 months from ablation.After ablation, there were no significant changes in P wave amplitude, area, or duration in leads II and III. There was a significant reduction in the area of the terminal negative deflection of the P wave in V1 from 0.38 mm2 to 0.13 mm2 (p = 0.03). There is also an acute increase in the amplitude and duration of the positive component of the P wave in V1 followed by a reduction in both by 6 months. Before ablation, 62.5% of the patients had biphasic P waves in V1. In 6 months, only 39.2% of them had biphasic P waves.Hybrid ablation causes a reduction of the terminal negative deflection of the P wave in V1 as well as temporal changes in the duration and amplitude of the positive component of the P wave in V1. This likely reflects the reduced electrical contribution of the posterior left atrium after ablation as well as anatomical and autonomic remodeling. Recognition of this altered sinus P wave morphology is useful in the diagnosis of atrial arrhythmias in this patient population.  相似文献   

16.
IntroductionThe efficacy of catheter ablation in patients with low cardiac function has been previously reported; however, only a few studies have included mid-range ejection fraction (mrEF). This study aimed to evaluate the efficacy and safety of atrial fibrillation (AF) ablation in patients with left ventricular ejection fraction (LVEF) < 50%.MethodsThis study retrospectively analyzed 79 patients (reduced ejection fraction [rEF]/mrEF, 38/41; paroxysmal/persistent, 37/42; heart failure hospitalizations within one year before ablation, 36 [45.6%]) who underwent the first ablation procedure at our hospital from April 2017 to December 2021. Radiofrequency ablation and cryoablation were performed for 69 and 10 patients, respectively.ResultsComplications included pacemaker implantation for postoperative sick sinus syndrome in one patient and inguinal hematoma in one patient. Regarding efficacy, there were significant postoperative improvements in echocardiographic data, blood test values, and diuretic use. After a mean follow-up of 60 months, 86.1% patients had no AF recurrence. There were 9 heart failure hospitalizations (11.4%) and 5 all-cause deaths (6.3%); no significant differences were found between the rEF and mrEF groups. No significant predictors of AF recurrence were found in preoperative patient characteristics.ConclusionAF ablation in patients with LVEF <50% significantly improved cardiac and renal functions with few complications, resulting in a high non-recurrence rate and reduced heart failure.  相似文献   

17.
Mechano-electric feedback and atrial fibrillation   总被引:4,自引:0,他引:4  
Atrial fibrillation frequently occurs under conditions associated with atrial dilatation suggesting a role of mechano-electric feedback in atrial arrhythmogenesis. Although atrial arrhythmias may be due both to abnormal focal activity and reentrant mechanisms, the majority of sustained atrial arrhythmias have been ascribed to reentrant activity. Atrial stretch may contribute to focal arrhythmias by inducing afterdepolarizations and to reentrant arrhythmias by increasing the atrial surface, by shortening the refractory period and/or slowing the conduction velocity and by increasing their spatial dispersion. Experimental and clinical studies have demonstrated that changes in mechanical loading conditions may modulate the electrophysiological properties of the atria. These studies have, for the most part, involved the effects of acute stretch on atrial refractoriness. While studies in humans and intact animals yield divergent results due to the variety of loading conditions and neurohumoral influences, experimental studies in isolated preparations clearly show that atrial refractory period and action potential duration at early levels of repolarization shorten by acute atrial dilatation. Both experimental and human studies have shown that acute atrial stretch is arrhythmogenic and may induce triggered premature beats and atrial fibrillation.  相似文献   

18.
BackgroundThe present study was to evaluate the value of CHADS2 and CHA2DS2VASC scores on predicting left atrial (LA) or left atrial appendage (LAA) thrombus in atrial fibrillation (AF) patients prior to ablation in the real world of China.Methods and resultsA total of 397 patients with non-valvular AF were analyzed to determine the relationship between CHADS2 and CHA2DS2VASC scores and LA/LAA thrombus identified on transesophageal echocardiography prior to radiofrequency ablation(RFA). LA/LAA thrombus was present in 38 patients (9.6%). There was a strong association between higher CHADS2 score or CHA2DS2VASC score and LA/LAA thrombus. No thrombus was identified in patients with CHA2DS2VASC score of 0 regardless of anticoagulation status. However, LA/LAA thrombus was detected in 2.9% patients with CHADS2 score of 0 without adequate anticoagulation, while no thrombus was present in the patients with CHADS2 score of 0 with adequate anticoagulation. Univariate analysis showed that heart failure (LVEF<50%), LA≥40 mm, diabetes mellitus, previous stroke or TIA, CAD, hypertension, inadequate anticoagulation therapy, CHADS2 score of ≥2 and CHA2DS2VASC score of ≥2 were significantly associated with LA/LAA thrombus. Multivariable Cox regression analysis demonstrated that CHA2DS2VASC score of ≥2 (p = 0.02) and previous stroke or TIA (p = 0.04) were independently associated with LA/LAA thrombus regardless of anticoagulation status. ROC curve analysis showed that higher CHADS2 score and CHA2DS2VASC score could be similarly used to predict the presence of LA thrombus.ConclusionsBoth higher CHA2DS2VASC and CHADS2 scores were associated with LA/LAA thrombus in non-valvular AF patients prior to ablation. Although CHA2DS2VASC score and CHADS2 score had similar value to predict LA/LAA thrombus, CHA2DS2VASc score was better to identify low-risk patients for LA/LAA thrombus than CHADS2 score without anticoagulation. There will be a possibility of performing AF ablation or cardioversion in patients with a CHA2DS2VASC of 0 without TEE or anticoagulation therapy. The safety need to be verified by more multicentre randomized controlled clinical trails.  相似文献   

19.
Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF.

Methods and results

Seventeen patients (16 males, mean age 73?±?6 years, mean EF 25?±?5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103?±?22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up.

Conclusion

Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population.  相似文献   

20.
BackgroundThis review aims to determine if patients who undergo atrial fibrillation (AF) ablation with heart failure with preserved ejection fraction (HFpEF) do better, or worse or the same compared to patients with heart failure with reduced ejection fraction (HFrEF).MethodsA search of MEDLINE and EMBASE was performed using the search terms: “atrial fibrillation”, “ablation” and terms related to HFpEF and HFrEF in order to identify studies that evaluated one or more of i) AF recurrence, ii) periprocedural complications and iii) adverse outcomes at follow up for patients with HFpEF and HFrEF who underwent AF ablation. Data was extracted from included studies and statistically pooled to evaluate adverse events and AF recurrence.Results5 studies were included in this review and the sample size of the studies ranged from 91 to 521 patients with heart failure. There was no significant difference in the pooled rate for no AF or symptom recurrence after AF ablation comparing patients with HFpEF vs HFrEF (RR 1.07 95%CI 0.86–1.33, p = 0.15). The most common complications were access site complications/haematoma/bleeding which occurred in similar proportion in each group; HFpEF (3.1%) and HFrEF (3.1%). In terms of repeat ablations, two studies were pooled to yield a rate of 78/455 (17.1%) for HFpEF vs 24/279 (8.6%) for HFrEF (p = 0.001.ConclusionsHeart failure patients with preserved or reduced ejection fraction have similar risk of AF or symptom recurrence after AF ablation but two studies suggest that patients with HFpEF are more likely to have repeat ablations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏