首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p < 0.01). Method of measurement interacted with axial rotation in anterior/posterior tilt and protraction/retraction (p < 0.01). The AMC had strong agreement with the reference stylus than the locator for the majority of humeral elevations, planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations.  相似文献   

2.
This study determined the ratio between glenohumeral and three-dimensional scapular motion during arm elevation and lowering in 91 individuals without shoulder pain. Scapular kinematics were assessed using an electromagnetic tracking device. Individuals performed 3 repetitions of elevation and lowering of the arm in the sagittal plane. Two-way ANOVAs (interval: 30–60°, 60–90°, 90–120° x phase: elevation and lowering) and paired t-tests were used for data analysis. For scapular internal/external rotation, lesser scapular internal rotation contribution was found during the 60–90° interval as compared to the 90–60° interval. Lesser scapular external rotation was identified in the 60–30° interval of arm lowering. The ratio was greater during arm elevation (1.89) compared to lowering (1.74) across the entire motion arc. For scapular upward rotation, greater upward rotation contribution was observed during arm elevation at the 30–60° interval, and less scapular downward rotation contribution in the final range of arm lowering. For scapular tilt, lesser scapular posterior tilt contribution during arm elevation was observed compared to arm lowering. The ratios between glenohumeral elevation/lowering and each individual scapulothoracic motion showed either differences between intervals and/or between elevation and lowering during specific intervals in healthy individuals.  相似文献   

3.
Identification of scapular dyskinesis and evaluation of interventions depend on the ability to properly measure scapulothoracic (ST) motion. The most widely used measurement approach is the acromion marker cluster (AMC), which can yield large errors in extreme humeral elevation and can be inaccurate in children and patient populations. Recently, an individualized regression approach has been proposed as an alternative to the AMC. This technique utilizes the relationship between ST orientation, humerothoracic orientation and acromion process position derived from calibration positions to predict dynamic ST orientations from humerothoracic and acromion process measures during motion. These individualized regressions demonstrated promising results for healthy adults; however, this method had not yet been compared to the more conventional AMC. This study compared ST orientation estimates by the AMC and regression approaches to static ST angles determined by surface markers placed on palpated landmarks in typically developing adolescents performing functional tasks. Both approaches produced errors within the range reported in the literature for skin-based scapular measurement techniques. The performance of the regression approach suffered when applied to positions outside of the range of motion in the set of calibration positions. The AMC significantly underestimated ST internal rotation across all positions and overestimated posterior tilt in some positions. Overall, root mean square errors for the regression approach were smaller than the AMC for every position across all axes of ST motion. Accordingly, we recommend the regression approach as a suitable technique for measuring ST kinematics in functional motion.  相似文献   

4.
The aim of this study is to determine the errors of scapular localisation due to skin relative to bone motion with an optoelectronic tracking system. We compared three-dimensional (3D) scapular positions obtained with skin markers to those obtained through palpation of three scapular anatomical landmarks. The scapular kinematics of nine subjects were collected. Static positions of the scapula were recorded with the right arm elevated at 0°, 40°, 80°, 120° and 160° in the sagittal plane. Palpation and subsequent digitisation of anatomical landmarks on scapula and thorax were done at the same positions. Scapular 3D orientation was also computed during 10 repeated movements of arm elevation between 0° and 180°. Significant differences in scapular kinematics were seen between static positions and palpation when considering anterior/posterior tilt and upward/downward rotation at angles over 120° of humeral elevation and only at 120° for internal/external rotation. There was no significant difference between positions computed during static positions and during the movement for the three scapular orientations. A rotation correction model is presented in order to reduce the errors between static position and palpation measurement.  相似文献   

5.
IntroductionThe acromion marker cluster (AMC) is a non-invasive scapular motion tracking method. However, it lacks testing in clinical populations, where unique challenges may present. This investigation resolved the utility of the AMC approach in a compromised clinical population.MethodsThe upper body of breast cancer survivors (BCS) and controls were tracked via motion capture and scapular landmarks palpated and recorded using a digitizer at static neutral to maximum elevation postures. The AMC tracked the scapula during dynamic maximum arm abduction. Both single (SC) and double calibration (DC) methods were applied to calculate scapular angles. The influences of calibration method, elevation, and group on mean and absolute error with two-way fixed ANOVAs with interactions (p < 0.05). Root mean square errors (RMSE) were calculated and compared.ResultsDC improved AMC estimation of palpated scapular orientation over SC, especially at higher arm elevations; RMSE averaged 11° higher for SC than DC at maximum elevation, but the methods were only 2.2° different at 90° elevation. DC of the AMC yielded mean error values of ∼5–10°. These approximate errors reported for AMC with young, lean adults.ConclusionsThe AMC with DC is a non-invasive method with acceptable error for measuring scapular motion of BCS and age-matched controls.  相似文献   

6.
For kinematic studies of the shoulder, electromagnetic sensors are commonly placed on the humerus, scapula, and trunk. The trunk sensor is used to describe humeral and scapular kinematics with respect to the trunk. There are two common trunk sensor placements, the sternum or third thoracic vertebrae (T3). It is currently unclear if placement of the trunk sensor affects kinematics, making it difficult to compare data across studies. The purpose of this study was to compare two trunk sensor placements (T3 and sternum) on trunk and scapular kinematics during arm elevation. An electromagnetic tracking system was used to collect kinematic data during five consecutive repetitions of ascending and descending arm elevation in the sagittal plane. The results indicate that trunk sensor placement had no significant effect on trunk kinematics or scapular upward/downward rotation and internal/external rotation. Scapular anterior/posterior tilt was significantly greater when the trunk sensor was on the sternum compared to the T3 vertebrae during ascending 30°–120°: mean difference = −3.51° (95%CI: −5.61, −1.40), and descending 120°–30°: mean difference = −3.27° (95%CI: −6.07, −0.48). However, the difference in anterior/posterior tilt did not exceed the error (minimal detectable change), and thus is likely not a meaningful difference. These results indicate the trunk sensors can be affixed on T3 or the sternum, depending on the needs of the study.  相似文献   

7.
This study described the three-dimensional shoulder motion during the arm elevation in individuals with isolated acromioclavicular osteoarthritis (ACO) and ACO associated with rotator cuff disease (RCD), as compared to controls. Seventy-four participants (ACO = 23, ACO + RCD = 25, Controls = 26) took part of this study. Disability was assessed with the DASH, three-dimensional kinematics were collected during arm elevation in the sagittal and scapular planes, and pain was assessed with the 11-point numeric pain rating scale. For each kinematic variable and demographic variables, separate linear mixed-model 2-way ANOVAs were performed to compare groups. Both ACO groups had higher DASH and pain scores. At the scapulothoracic joint, the isolated ACO group had greater internal rotation than control, and the ACO + RCD group had greater upward rotation than both other groups. At the sternoclavicular joint, both groups with ACO had less retraction, and the isolated ACO group had less elevation and posterior rotation. At the acromioclavicular joint, the isolated ACO group had greater upward rotation, and both ACO groups had greater posterior tilting. Patients with ACO had altered shoulder kinematics, which may represent compensatory responses to reduce pain and facilitate arm motion during arm elevation and lowering.  相似文献   

8.
Knowledge of three-dimensional scapular movements is essential to understand post-stroke shoulder pain. The goal of the present work is to determine the feasibility and the within and between session reliability of a movement protocol for three-dimensional scapular movement analysis in stroke patients with mild to moderate impairment, using an optoelectronic measurement system. Scapular kinematics of 10 stroke patients and 10 healthy controls was recorded on two occasions during active anteflexion and abduction from 0° to 60° and from 0° to 120°. All tasks were executed unilaterally and bilaterally. The protocol’s feasibility was first assessed, followed by within and between session reliability of scapular total range of motion (ROM), joint angles at start position and of angular waveforms. Additionally, measurement errors were calculated for all parameters. Results indicated that the protocol was generally feasible for this group of patients and assessors. Within session reliability was very good for all tasks. Between sessions, scapular angles at start position were measured reliably for most tasks, while scapular ROM was more reliable during the 120° tasks. In general, scapular angles showed higher reliability during anteflexion compared to abduction, especially for protraction. Scapular lateral rotations resulted in smallest measurement errors. This study indicates that scapular kinematics can be measured reliably and with precision within one measurement session. In case of multiple test sessions, further methodological optimization is required for this protocol to be suitable for clinical decision-making and evaluation of treatment efficacy.  相似文献   

9.
Characterization of scapular kinematics under demanding load conditions might aid to distinguish between physiological and clinically relevant alterations. Previous investigations focused only on submaximal external load situations. How scapular movement changes with maximal load remains unclear. Therefore, the present study aimed to evaluate 3D scapular kinematics during unloaded and maximal loaded shoulder flexion and extension. Twelve asymptomatic individuals performed shoulder flexion and extension movements under unloaded and maximal concentric and eccentric loaded isokinetic conditions. 3D scapular kinematics assessed with a motion capture system was analyzed for 20° intervals of humeral positions from 20° to 120° flexion. Repeated measures ANOVAs were used to evaluate kinematic differences between load conditions for scapular position angles, scapulohumeral rhythm and scapular motion extent. Increased scapular upward rotation was seen during shoulder flexion and extension as well as decreased posterior tilt and external rotation during eccentric and concentric arm descents of maximal loaded compared to unloaded conditions. Load effects were further seen for the scapulohumeral rhythm with greater scapular involvement at lower humeral positions and increased scapular motion extent under maximal loaded shoulder movements. With maximal load applied to the arm physiological scapular movement pattern are induced that may imply both impingement sparing and causing mechanisms.  相似文献   

10.
11.
Through the onset of post-stroke motor disorders, the normal scapular function is compromised. As a result, shoulder pain and associated upper limb dysfunctions frequently arise after stroke.This review aimed to provide a systematic overview of available literature on scapular function, i.e. scapular three-dimensional (3D) kinematics and muscle activity during elevation, in healthy persons, persons with primary shoulder disorders and post-stroke patients. 3D scapular kinematics have been widely reported in healthy persons and persons with primary shoulder disorders, whereby a general pattern of upward rotation and posterior tilt during elevation has been agreed upon. Results on scapular internal/external rotation are inconsistent. In a post-stroke population, 3D scapular kinematics are less frequently reported. Scapular muscle activity has thus far been studied to very limited extend and firm conclusions could not be drawn.Although 3D scapular kinematics and muscle activity registrations are being increasingly used, some general methodological aspects should be considered. While the International Society of Biomechanics already proposed recommendations on the definition of upper limb joint coordinate systems and rotation sequences, proper result comparison necessitates further guidelines on other methodological aspects, i.e. data collection, processing, analyzing, and reporting.  相似文献   

12.
The most recent non-invasive methods for the recording of scapular motion are based on an acromion marker (AM) set and a single calibration (SC) of the scapula in a resting position. However, this method fails to accurately measure scapular kinematics above 90° of arm elevation, due to soft tissue artifacts of the skin and muscles covering the acromion. The aim of this study was to evaluate the accuracy, and inter-trial and inter-session repeatability of a double calibration method (DC) in comparison with SC. The SC and DC data were measured with an optoelectronic system during arm flexion and abduction at different angles of elevation (0-180°). They were compared with palpation of the scapula using a scapula locator. DC data was not significantly different from palpation for 5/6 axes of rotation tested (Y, X, and Z in abduction and flexion), where as SC showed significant differences for 5/6 axes. The root mean square errors ranged from 2.96° to 4.48° for DC and from 6° to 9.19° for SC. The inter-trial repeatability was good to excellent for SC and DC. The inter-session repeatability was moderate to excellent for SC and moderate to good for DC. Coupling AM and DC is an easy-to-use method, which yields accurate and reliable measurements of scapular kinematics for the complete range of arm motion. It can be applied to the measurement of shoulder motion in many fields (sports, orthopaedics, and rehabilitation), especially when large ranges of arm motion are required.  相似文献   

13.
Scapular kinematics in healthy adults is well described in the literature but little is known on typical children. This study aimed to compare the three-dimensional (3-D) scapular kinematics and scapulohumeral rhythm during the elevation and lowering of the arm in the scapular plane in typical children and healthy adults. Twenty-six healthy adults (35.34 ± 11.65 years, 1.70 ± 0.10 m, 70.00 ± 12.30 kg) and 33 typical children (9.12 ± 1.51 years, 1.40 ± 0.10 m, 35.40 ± 10.45 kg) participated in this study. 3-D scapular kinematics were obtained using an electromagnetic tracking device. The subjects were asked to elevate and lower their arm in the scapular plane. Children showed less scapular protraction compared to adults at 120° during arm elevation, more anterior tilt than adults in the elevation and also at 60°, 90° and 120° during lowering of the arm. Children also showed higher scapulohumeral rhythm during lowering of the arm compared to adults from 90° to 60°. It was also found a low to little correlation between scapular position and age. The study showed small but significant differences in scapular kinematics and scapulohumeral rhythm between children and adults. These results can help clinicians to improve diagnosis and treatment protocols directed to children with dysfunction, as reference values on scapular kinematics in healthy children are also provided in this study.  相似文献   

14.
Scapular kinematics during sports performances can be recorded using skin-mounted trackers attached to the skin overlying the acromion for continuous data collection without restricting natural motions of the subject relative to medical imaging analyses limiting its use for wide-range or high-speed motions. This study aimed to describe the existence of a directional bias in the translational and rotational errors of skin-mounted trackers using a 3D magnetic resonance imaging (3D-MRI) protocol. 3D-MRI scans of the healthy right shoulders of 19 males were acquired in 12 arm positions. The relative transformation of the scapular configuration determined to be the measurement error, as recorded by the configuration of the small cuboid imitating a skin-mounted tracker relative to the actual scapular configuration measured by the voxel-based registration. These measurement errors were expressed with either positive or negative values to describe the bias. Overall translational errors in the lateral, anterior, and superior directions were 3.7 ± 8.4 mm, 9.5 ± 6.4 mm, and 6.2 ± 4.6 mm, respectively. Overall rotational errors in protraction, upward rotation, and posterior tilt were 7.8 ± 8.4°, 0.2 ± 7.4°, and − 4.0 ± 7.5°, respectively. The skin-mounted tracker displayed a high probability of displacement in antero-superior (93% and 91%) directions and rotates in a protracting manner (82%) relative to the position of the underlying bone with the gradual nature of its change. The existence of the directional bias with its gradual change suggests a statistical predictability in measurement errors, which can be used to predict accurate scapular translation and rotation.  相似文献   

15.
Pain and tenderness of the upper trapezius are the major complaints among people with chronic neck and shoulder disorders. Hyper-activation and increased muscle tension of the upper trapezius during arm elevation will cause imbalance of the scapular muscle force and contribute to neck and shoulder disorders. Assessing the elasticity of the upper trapezius in different arm positions is therefore important for identifying people at risk so as to give preventive programmes or for monitoring the effectiveness of the intervention programmes for these disorders. This study aimed to establish the reliability of supersonic shear imaging (SSI) in quantifying upper trapezius elasticity/shear elastic modulus and its ability to measure the modulation of muscle elasticity during arm elevation. Twenty-eight healthy adults (15 males, 13 females; mean age = 29.6 years) were recruited to participate in the study. In each participant, the shear elastic modulus of the upper trapezius while the arm was at rest and at 30° abduction was measured by two operators and twice by operator 1 with a time interval between the measurements. The results showed excellent within- and between-session intra-operator (ICC = 0.87–0.97) and inter-observer (ICC = 0.78–0.83) reliability for the upper trapezius elasticity with the arm at rest and at 30° abduction. An increase of 55.23% of shear elastic modulus from resting to 30° abduction was observed. Our findings demonstrate the possibilities for using SSI to quantify muscle elasticity and its potential role in delineating the modulation of upper trapezius elasticity, which is essential for future studies to compare the differences in shear elastic modulus between normal elasticity and that of individuals with neck and shoulder disorders.  相似文献   

16.
PurposeThis study aimed to investigate the effect of elastic taping on kinematics, muscle activity and strength of the scapular region in baseball players with shoulder impingement.ScopeSeventeen baseball players with shoulder impingement were recruited from three amateur baseball teams. All subjects received both the elastic taping (Kinesio TexTM) and the placebo taping (3 M Micropore tape) over the lower trapezius muscle. We measured the 3-dimensional scapular motion, electromyographic (EMG) activities of the upper and lower trapezius, and the serratus anterior muscles during arm elevation. Strength of the lower trapezius was tested prior to and after each taping application. The results of the analyses of variance (ANOVA) with repeated measures showed that the elastic taping significantly increased the scapular posterior tilt at 30° and 60° during arm raising and increased the lower trapezius muscle activity in the 60–30° arm lowering phase (p < 0.05) in comparison to the placebo taping.ConclusionsThe elastic taping resulted in positive changes in scapular motion and muscle performance. The results supported its use as a treatment aid in managing shoulder impingement problems.  相似文献   

17.

Background

The success of Total Shoulder Arthroplasty (TSA) is believed to depend on the restoration of the natural anatomy of the joint and a key development has been the introduction of modular humeral components to more accurately restore the patient’s anatomy. However, there are no peer-reviewed studies that have reported the degree of glenoid component mal-position achieved in clinical practice and the clinical outcome of such mal-position. The main purpose of this study was to assess the accuracy of glenoid implant positioning during TSA and to relate it to the radiological (occurrence of radiolucent lines and osteolysis on CT) and clinical outcomes.

Methods

68 TSAs were assessed with a mean follow-up of 38+/−27 months. The clinical evaluation consisted of measuring the mobility as well as of the Constant Score. The radiological evaluation was performed on CT-scans in which metal artefacts had been eliminated. From the CT-scans radiolucent lines and osteolysis were assessed. The positions of the glenoid and humeral components were also measured from the CT scans.

Results

Four position glenoid component parameters were calculated The posterior version (6°±12°; mean ± SD), the superior tilt (12°±17°), the rotation of the implant relative to the scapular plane (3°±14°) and the off-set distance of the centre of the glenoid implant from the scapular plane (6±4 mm). An inferiorly inclined implant was found to be associated with higher levels of radiolucent lines while retroversion and non-neutral rotation were associated with a reduced range of motion.

Conclusion

this study demonstrates that glenoid implants of anatomic TSA are poorly positioned and that this malposition has a direct effect on the clinical and radiological outcome. Thus, further developments in glenoid implantation techniques are required to enable the surgeon to achieve a desired implant position and outcome.  相似文献   

18.
19.
An analysis of secondary shoulder motions (humeral rotation, humeral head anterior/posterior translation, scapular tipping, and scapular upward/downward rotation) in subjects with anterior/posterior shoulder tightness provides the opportunity to examine the role of tightness as a means of affecting shoulder motions. Subjects with shoulder tightness (anterior, n = 12; posterior, n = 12) elevated their arms in the scapular plane. Three replicated movements were performed to the maximum motions. Kinematics data were collected by FASTRAK 3D electromagnetic system. To determine if a significant difference of the secondary motions existed between anterior/posterior shoulder tightness, two-factor mixed ANOVA models with the repeated factor of elevation angle (five elevation angles) and the independent factor of group were calculated. The relationships between the self-reported functional scores (Flexilevel Scale of Shoulder Function, FLEX-SF) and abnormal shoulder kinematics were assessed. For humeral head anterior/posterior translation, the subjects with posterior tightness demonstrated anterior humeral head translation (10 mm, p = 0.019) compared to subjects with anterior tightness. The subjects with anterior tightness demonstrated less posterior tipping (2.2°, p = 0.045) compared to subjects with posterior tightness. The humeral anterior translation had moderate relationships with FLEX-SF scores (r = ?0.535) in subjects with posterior tightness. The scapular tipping had moderate relationships with FLEX-SF scores (r = 0.432) in subjects with anterior tightness. In conclusion, the secondary motions were different between subjects with anterior and posterior shoulder tightness. During arm elevation, less scapular posterior tipping and less posterior humeral head translation in subjects with anterior and posterior shoulder tightness, respectively, are significantly related to self-reported functional disability in these subjects.  相似文献   

20.
BackgroundScapular taping is frequently used in the management of shoulder pain and as a part of injury prevention strategies in sports. It is believed to alter scapular kinematics and restore normal motion. However, there is little evidence to support its use. The aim of the study was to investigate the effect of shoulder taping on the scapular kinematics of asymptomatic subjects.MethodThirteen asymptomatic subjects performed elevations in the sagittal and scapular planes with no tape and after the application of tape. A motion tracking system and a scapula locator method were used to measure the shoulder movement. Co-ordinate frames were defined for the thorax, humerus and scapula and Euler angles were used to calculate joints rotations.ResultsScapular taping increased the scapular external and upward rotations and posterior tilt in elevations in the sagittal plane (p < 0.001). In the scapular plane, taping increased scapular external rotation (p < 0.05).ConclusionsTaping affects scapulothoracic kinematics in asymptomatic subjects. The effect may be different for different planes of movement. The findings have implications on the use of taping as a preventive measure in high-risk groups. Further work is needed to assess the effect of taping on symptomatic populations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号