首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

2.
A single method is described for quantitation of 14 retinoids found in biological material. The method consists of reversed-phase HPLC, internal standardization, and carrier extraction procedures with three synthetic retinoids. Primary standardization of HPLC uv detector is achieved using tritiated all-trans-retinoic acid, all-trans-retinol, all-trans-retinyl palmitate, and all-trans-retinyl acetate. Extraction methods are standardized by correlating the uv absorbance of retinoids at 340 nm with radioactivity of tritiated retinoids of known specific activity. Quantitation of 10 pg of tritiated or 5 ng of nonradioactive retinoid per 0.1 g sample in a polarity range from 4-oxo-retinoic acid to retinyl stearate can be achieved in a single, 50-min chromatographic run. A single HPLC pump, a C18 reversed-phase analytical column, a multistep three-solvent gradient, and inexpensive solvents based on methanol, water, and chloroform comprise this cost-effective chromatographic system. Our primary standardization method allows investigators employing different procedures to compare results between laboratories by standardizing the HPLC uv detector with commercially available tritiated retinoids. With this method we were able to quantitate nanomolar amounts of endogenous retinoic acids and retinyl esters, that "HPLC uv only" conditions usually would not detect in the circulation and liver of rats under physiological conditions.  相似文献   

3.
In this study, a method for partly automated sample preparation and fully automated solid-phase extraction method for plasma, kidney and liver samples for various retinoids like all-trans-4-oxo-retinoic acid, 13-cis-4-oxo-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid, all-trans-retinoic acid, retinol and retinyl palmitate was established. Plasma, embryo-, kidney-and liver-homogenates were automatically mixed and extracted on multiple usage solid-phase (C2) extraction cartridges immediately before HPLC analysis. Automated cleaning, preconditioning and incorporation of the loaded cartridge to fully automated HPLC separation and quantification of the various retinoids in a single HPLC run was established. The recovery of the retinoids was generally between 80 and 90%. Intra-day repeatability was < 11.7%. As little as 1.2 ng/ml could be quantified in lipid-mixture standard samples. This method allows a highly automated sample preparation and a fully automated solid-phase extraction with good selectivity for the study of endogenous retinoids and retinoids after nutritional supplementations and pharmacological applications in several biological samples.  相似文献   

4.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

5.
A method for the determination of I, a peptide-doxorubicin conjugate that was evaluated for the treatment of prostate cancer, and two of its active metabolites, doxorubicin and leucine-doxorubicin is described. Blood samples were chilled immediately after being drawn in order to prevent ex vivo entry of the metabolites into red blood cells. EDTA (10 mg/ml final concentration) was used to prevent plasma-mediated degradation of the peptide portion of the prodrug. After the addition of internal standard, plasma was prepared for analysis using a C-8 solid-phase extraction column. In order to overcome secondary ionic interactions with the silica-based extraction column, the analytes were eluted with ammonium hydroxide in methanol. The extracts were evaporated to dryness, reconstituted, and assayed by step change, gradient, reverse phase HPLC with fluorescence detection. Two interfering metabolites found in post dose plasma were chromatographically separated by an adjustment of the mobile phase pH. The within-day reproducibility of the doxorubicin and leucine-doxorubicin chromatographic retention times was improved by a brief washing of the analytical column with 90% acetonitrile after each injection. The range of the standard curve was 12.5-1250 ng/ml for doxorubicin and 25-2500 ng/ml for I and leucine-doxorubicin.  相似文献   

6.
An isocratic high-performance liquid chromatography method for the simultaneous determination of various fat-soluble vitamins and carotenoids is reported. The method utilizes a Radial-Pak C-18, 5-microns column and an elution solvent composed of methanol:acetonitrile:chloroform (25:60:15). Only 100 microliters of plasma sample is required for one determination. Retinol, alpha-tocopherol, alpha-carotene, beta-carotene, lycopene, zeaxanthin, and two other unidentified carotenoids can be clearly separated and quantified in one HPLC run using alpha-tocopheryl acetate or tocol as the internal standard. The eluted peaks are quantified by either a photodiode-array detector at preprogrammed wavelengths at the absorption maxima of the compounds or a dual-wavelength detector at 280 and 436 nm. The total run time is 16 min. With an automatic injector and a programmable detector, the system allows unattended operation. The within-run and day-to-day coefficients of variation range from 1 to 8%. The lower limits of determination are 2, 40, and 2 ng for retinol, alpha-tocopherol, and carotenes, respectively. In addition, the system monitors the absorption spectra of the eluant during the HPLC run; this allows the spectral identification of various compounds separated in the same run.  相似文献   

7.
8.
A reversed-phase, column-switching high-performance liquid chromatographic (HPLC) method is described for the determination of a new thymidylate synthase inhibitor in human plasma. The compound and an internal standard are extracted from plasma using a Certify II solid-phase cartridge. Extracts are evaporated to dryness and the residue is reconstituted with mobile phase buffer. The analytes are separated from polar interferences and buffer salts originating from the elution step on a 4-mm YMC Basic pre-column. The fraction containing the analytes is further separated on a 25-cm YMC Basic column. The analytes are detected by their absorbance at 250 nm. The limit of quantitation is 10 ng/ml. The method is linear from 10 ng/ml to 80 μg/ml using three standard curve ranges. Validation studies for all three ranges show the method to be reproducible. The method has been successfully used to support pharmacokinetic studies.  相似文献   

9.
A high-performance liquid chromatographic method is described for determination of sub-anaesthetic concentrations of the enantiomers of ketamine and its metabolite norketamine in plasma. The samples are purified by reversed-phase solid-phase extraction. The enantiomers are separated on a Chiral AGP column with a mobile phase containing 16% methanol and a 10 mM phosphate buffer at pH 7.0, and measured by UV-detection at a wavelength of 220 nm. Linear calibration curves with correlation coefficients better than 0.995 have been obtained in the range 10–320 ng/ml. Minimum detectable concentrations were about 2 ng/ml.  相似文献   

10.
High-performance liquid chromatography (HPLC) was used for simultaneous quantitation of carbamazepine (CBZ) and carbamazepine 10,11-epoxide (CBZ-EP) in plasma and saliva. Because concentrations of CBZ can greatly exceed those of CBZ-EP after single doses, two internal standards, lorazepam and N-desmethyldiazepam were added to all samples. Following extraction with chloroform, the components are separated on a μBondapak CN column with a mobile phase composed of 30% acetonitrile in water. Total chromatography time is 10 min. Concentrations of CBZ and CBZ-EP as low as 18 and 56 ng/ml, respectively, can be detected using 0.5 ml of plasma or saliva. The maximum within-day and day-to-day coefficients of variation for both compounds are 6.3 and 7.0%, respectively. Specificity of the method was supported by a significant correlation (r = 0.99) between assay results of the present method and those of a previously published HPLC assay. Application of the method to protein binding and salivary measurements in a single-dose CBZ disposition study is demonstrated.  相似文献   

11.
A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2–200 ng/ml. No chromatographic interferences were detected.  相似文献   

12.
A reversed-phase gradient high-performance liquid chromatographic (HPLC) procedure, which utilizes gradient elution and detection by a photodiode-array detector, has been developed to analyze simultaneously very polar retinoids, such as 4-oxo-retinoyl-β-glucuronide, retinoyl β-glucuronide and 4-oxo-retinoic acid; polar retinoids, such as retinoic acid and retinol; nonpolar retinoids, such as retinyl esters; along with xanthophylls, monohydroxy carotenoids, hydrocarbon carotenoids, and tocopherols. The procedure has been applied to the simultaneous analysis of retinoids, carotenoids, and tocopherols present in human serum and liver, rat serum and tissues, and for carotenoids in a number of fruits and vegetables. Bilirubin present in human serum can also be simultaneously analyzed. By this gradient HPLC procedure, 3,4-didehydroretinyl ester (vitamin A2 ester) has been identified as a minor constituent in a human liver sample. Lycopene was identified as a major carotenoid in one specimen of papaya fruit, and 5,6,5′,6′-diepoxy-β-carotene was characterized as a major carotenoid in one specimen of mango fruit.  相似文献   

13.
A new method of high-performance liquid chromatography (HPLC) analysis to quantify isomers of retinol, retinal and retinoic acid simultaneously was established. The HPLC system consisted of a silica gel absorption column and a linear gradient with two kinds of solvents containing n-Hexane, 2-propanol, and glacial acetic acid in different ratios. It separated six retinoic acid isomers (13-cis, 9-cis, all-trans, all-trans-4-oxo, 9-cis-4-oxo, 13-cis-4-oxo), three retinal isomers (13-cis-, 9-cis-, and all-trans) and two retinol isomers (13-cis- and all-trans). Human serum samples were subjected to this HPLC analysis and at least, all-trans retinol, 13-cis retinol, and all-trans retinoic acid were detectable. This HPLC system is useful for evaluating retinoic acid formation from retinol via a two-step oxidation pathway. Moreover, it could be applied to monitoring the concentrations of various retinoids, including all-trans retinoic acid in human sera.  相似文献   

14.
Puerarin, an isoflavone C-glycoside, has been identified as the major active component isolated from Pueraria lobata (Kudzu) responsible for suppression of alcohol drinking. In order to conduct clinical studies of Kudzu's efficacy, a method for measuring its bioavailability and pharmacokinetic profile is needed. We have developed a gradient reversed-phase HPLC system for pharmacokinetic study of puerarin in human plasma. Solid-phase extraction was performed on an abselut Nexus cartridge (60 mg/3 ml) possessing adsorbent function with a recovery of >97% and 4-hydroxybenzoic acid was used as an internal standard. The HPLC assay was performed on a YMC ODS-A column (150 mm x 4.6mm i.d., 5 microm particle size). The HPLC mobile phase consisted of methanol/0.5% acetic acid with 20-35% methanol gradient at a flow-rate of 0.8 ml/min. The UV wavelength was set at 254 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a puerarin concentration range of 5-500 ng/ml in human plasma. The lower limit of quantification was ca. at 8 ng/ml of puerarin in plasma. The detection limit (defined as signal-to-noise ratio of about 3) was approximately 3 ng/ml. The preliminary pharmacokinetic study after oral administration of the Kudzu capsules containing 400mg of puerarin to a healthy volunteer confirmed that the present method was suitable for determining puerarin in human plasma.  相似文献   

15.
A fast liquid chromatographic method with tandem diode array-fluorescence detection for the simultaneous determination of in total 17 opium alkaloids and opioids is presented. Blank blood and urine samples (1 ml) were spiked with different concentrations of a standard mixture, as well as with the internal standard, butorphanol (2000 ng/ml). After solid-phase extraction, based on weak cation exchange (Bond Elut CBA SPE columns), the extracts were examined by HPLC-DAD-FL. By using a "high-speed" phenyl column (53 x 7.0 mm I.D., particle size 3 microm) eluted with a gradient system (A: water-methanol (90:10, v/v), B: methanol, both containing 25 mM triethylammoniumformate (pH(A) = 4.5)) all compounds could be baseline separated within 12 min. The method was validated and its applicability was demonstrated by the analysis of real-time forensic cases.  相似文献   

16.
A high-performance liquid chromatography (HPLC) method was developed for quantification of both isomers of the thioxanthene neuroleptic flupentixol and of the butyrophenone derivative haloperidol in human serum. After extraction with diethyl ether–n-heptane (50:50, v/v), an isocratic normal-phase HPLC system with a Hypersil cyanopropyl silica column (250×4.6 mm, 5 μm particle size) was used with ultraviolet detection at 254 nm and elution with a mixture of 920 ml acetonitrile, 110 ml methanol, 30 ml 0.1 M ammonium acetate, and 50 μl triethylamine. The limit of quantitation of 0.5 ng/ml and 0.3 ng/ml for flupentixol and haloperidol, respectively, was sufficient to quantify both compounds in serum after administration of clinically adjusted doses. The suitability of the described method for therapeutic drug monitoring and clinical pharmacokinetic studies was assessed by analysis of more than 100 trough level serum samples.  相似文献   

17.
A high-performance liquid chromatographic method for the determination of miconazole in human plasma is described. A solid-phase extraction was performed on an octadecyl (C18) cartridge. Miconazole was eluted with methanol, separated on a reversed-phase column and was measured by ultraviolet detection at 230 nm. The absolute extraction recovery from plasma samples was 85%. The limit of detection was established as 5 ng/ml. The coefficient of variation of the determination of plasma levels by this method over the standard curve concentration range was less than 10%, except with the concentration of 10 ng/ml. The plasma levels of miconazole in twelve healthy volunteers given a 250-mg oral dose of two tablet forms were determined by this method.  相似文献   

18.
Sanguinarine is a quaternary benzo[c]phenanthridine alkaloid, extracted from the argemone oil, which produced severe human intoxications. To investigate the sanguinarine biotransformation, we develop a simple extraction process and a high performance liquid chromatographic separation coupled to a sensitive fluorometric detection of sanguinarine in cell culture medium, as well as in rat urine and plasma. After extraction with an acidified organic solvent, sanguinarine elution is performed within 15 min on a Nucleosil C18 column with a gradient using 0.2% formic acid/water/acetonitrile as mobile phase. Extracted and standard sanguinarine are characterized by mass spectrometry. The extraction recovery of sanguinarine is about 80% in cell culture medium and in rat urine, but lower in plasma. This convenient high performance liquid chromatography (HPLC) method allows to quantify sanguinarine over concentrations ranged 10-2000 ng ml(-1). The limit of fluorometric detection is 0.5 ng. Under these conditions, the lower limit of quantification of sanguinarine is 50 ng ml(-1) in cell culture medium and in rat urine and 100 ng ml(-1) in rat plasma. This analytical HPLC method is specific, linear and reproducible in all media and is suitable for quantitative determination of sanguinarine in biological fluids.  相似文献   

19.
Pirenzepine was considered as a pharmacologic agent of preventing form-deprivation myopia. To assess the ocular bioavailability of pirenzepine, a HPLC method for determination of pirenzepine in rabbit aqueous humor was developed. An HPLC system was used in the reverse phase mode for the determination of pirenzepine. A Luna RP18 5 microm 4.6 mm x 150 mm column was employed at 35 degrees C. The mobile phase was methanol/0.02 M KH2PO4/sodium 1-pentanesulfonate (350/650/1, v/v/m, pH was adjusted to 8.0 by dropping 1M NaOH). The flow rate was 1 ml/min. Pirenzepine was monitored at 280 nm. Sample treatment procedure consists of deproteinisation with methanol. Calibration curves fitted by plotting the peak area versus concentration were linear in the range 20-400 ng/ml. The limit of quantification (LOQ) of present method was 20 ng/ml. Within-day and inter-day coefficient of variation was lower than 10%. Analytical recoveries were determined as 92.4, 95.4 and 101.4% at concentrations of 40, 200 and 400 ng/ml. In conclusion, this HPLC method using a simple sample treatment procedure appears suitable for monitoring ocular concentration of pirenzepine.  相似文献   

20.
Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid-liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 microg/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号