1.

Purpose

To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopic astigmatism.

Methods

We examined 26 eyes of 26 patients undergoing FLEx and 26 eyes of 26 patients undergoing SMILE to correct myopic astigmatism (manifest astigmatism of 1 diopter (D) or more). Visual acuity, cylindrical refraction, the predictability of the astigmatic correction, and the astigmatic vector components using Alpin’s method, were compared between the two groups 3 months postoperatively.

Results

We found no statistically significant difference in manifest cylindrical refraction (p=0.74) or in the percentage of eyes within ± 0.50 D of their refraction (p=0.47) after the two surgical procedures. Moreover, no statistically significant difference was detected between the groups in astigmatic vector components, namely, surgically induced astigmatism (0.80), target induced astigmatism (p=0.87), astigmatic correction index (p=0.77), angle of error (p=0.24), difference vector (p=0.76), index of success (p=0.91), flattening effect (p=0.79), and flattening index (p=0.84).

Conclusions

Both FLEx and SMILE procedures are essentially equivalent in correcting myopic astigmatism using vector analysis, suggesting that the lifting or non-lifting of the flap does not significantly affect astigmatic outcomes after these surgical procedures.  相似文献   

2.

Purpose

To evaluate one-step topography-guided transepithelial ablation in the treatment of low to moderate myopic astigmatism using a 1KHz excimer laser.

Methods

Retrospective study of 117 consecutive eyes available for evaluation 12 months after surgery. Pre- and post-operative visual and refractive data as well as post-operative pain and haze were analyzed. A novel technique integrating custom refractive- and epithelial- ablation in a single uninterrupted procedure was used.

Results

The mean pre-operative spherical equivalent (SE) and the mean cylinder were: –3.22 diopters (D) ±1.54 (SD) (range –0.63 to –7.25 D) and –0.77 D ±0.65 (range 0 to –4.50 D), respectively. At 12 months after surgery: no eyes lost ≥2 lines of corrected distant visual acuity (CDVA). Safety and efficacy indexes were 1.27 and 1.09, respectively. Uncorrected distant visual acuity (UDVA) was ≥20/20 in 96.6% of the eyes. Manifest refraction spherical equivalent was within ±0.5 D of the desired refraction in 93.2% of the eyes. Average root mean square (RMS) wavefront error measured at central 6 mm, increased from 0.38 pre-operatively to 0.47 µm post-operatively. Refractive stability was achieved and sustained 1 month after surgery. No visually significant haze was registered during the observation period. Post-operative pain was reported in 4.5% of patients.

Conclusions

One-step transepithelial topography-guided treatment for low to moderate myopia and astigmatism performed with a 1 KHz laser, provided safe, effective, predictable and stable results with low pain and no visually significant haze.  相似文献   

3.

Purpose

To assess the characteristic findings and effects of laser capsulotomy in patients with late postoperative capsular bag distension syndrome (CBDS).

Methods

Twenty patients diagnosed with late postoperative CBDS between July 2010 and August 2013 were retrospectively reviewed. Before and 1 week after capsulotomy, changes in the anterior chamber depth (ACD) were assessed using ultrasound biomicroscopy. Changes in the refractive status and uncorrected visual acuity (UCVA) were also measured 1 week and 1 month after capsulotomy. For patients who received bilateral cataract surgery, preoperative ACD and axial length measured by IOLMaster were compared between the two eyes.

Results

Twenty-two eyes from 20 patients who had undergone laser capsulotomy showed a mean UCVA improvement of 0.27 ± 0.24 logMAR (range, 0.00–0.90). ACD was increased by an average of +0.04 mm (95% confidence interval, +0.01 to +0.06 mm, p = 0.034), equivalent to predicted refractive change of +0.10 D. The discrepancy between actual (+1.33 D) and predicted refractive change after capsulotomy suggests that refractive change may not be generated from IOL displacement in late postoperative CBDS. Preoperative ACD was deeper in the eye with late postoperative CBDS in all bilaterally pseudophakic patients (mean, 3.68 mm vs. 3.44 mm in the fellow eye, p = 0.068).

Conclusions

Late postoperative CBDS showed refractive changes that were resolved successfully after laser capsulotomy. The convex lens effects of opalescent material in the distended capsular bag may play a major role in myopic shift. A larger preoperative ACD is possibly associated with the development of late postoperative CBDS.  相似文献   

4.

Purpose

To investigate the association between ocular sensory dominance and interocular refractive error difference (IRED).

Methods

A total of 219 subjects were recruited. The refractive errors were determined by objective refraction with a fixation target located 6 meters away. 176 subjects were myopic, with 83 being anisometropic (IRED ≥ 0.75 D). 43 subjects were hyperopic, with 22 being anisometropic. Sensory dominance was measured with a continuous flashing technique with the tested eye viewing a Gabor increasing in contrast and the fellow eye viewing a Mondrian noise decreasing in contrast. The log ratio of Mondrian to Gabor’s contrasts was recorded when a subject just detected the tilting direction of the Gabor during each trial. T-test was used to compare the 50 values collected from each eye, and the t-value was used as a subject’s ocular dominance index (ODI) to quantify the degree of ocular dominance. A subject with ODI ≥ 2 (p < 0.05) had clear dominance and the eye with larger mean ratio was the dominant one. Otherwise, a subject had an unclear dominance.

Results

The anisometropic subjects had stronger ocular dominance in comparison to non-anisometropic subjects (rank-sum test, p < 0.01 for both myopic and hyperopic subjects). In anisometropic subjects with clear dominance, the amplitude of the anisometropia was correlated with ODI values (R = 0.42, p < 0.01 in myopic anisometropic subjects; R = 0.62, p < 0.01 in hyperopic anisometropic subjects). Moreover, the dominant eyes were more myopic in myopic anisometropic subjects (sign-test, p < 0.05) and less hyperopic in hyperopic anisometropic subjects (sign-test, p < 0.05).

Conclusion

The degree of ocular sensory dominance is associated with interocular refractive error difference.  相似文献   

5.

Purpose

To investigate the distribution of posterior corneal astigmatism in eyes with with-the-rule (WTR) and against-the-rule (ATR) anterior corneal astigmatism.

Methods

We retrospectively examined six hundred eight eyes of 608 healthy subjects (275 men and 333 women; mean age ± standard deviation, 55.3 ± 20.2 years). The magnitude and axis orientation of anterior and posterior corneal astigmatism were determined with a rotating Scheimpflug system (Pentacam HR, Oculus) when we divided the subjects into WTR and ATR anterior corneal astigmatism groups.

Results

The mean magnitudes of anterior and posterior corneal astigmatism were 1.14 ± 0.76 diopters (D), and 0.37 ± 0.19 D, respectively. We found a significant correlation between the magnitudes of anterior and posterior corneal astigmatism (Pearson correlation coefficient r = 0.4739, P<0.001). In the WTR anterior astigmatism group, we found ATR astigmatism of the posterior corneal surface in 402 eyes (96.6%). In the ATR anterior astigmatism group, we found ATR posterior corneal astigmatism in 82 eyes (73.9%). Especially in eyes with ATR anterior corneal astigmatism of 1 D or more and 1.5 D or more, ATR posterior corneal astigmatism was found in 28 eyes (59.6%) and 9 eyes (42.9%), respectively.

Conclusions

WTR anterior astigmatism and ATR posterior astigmatism were found in approximately 68% and 91% of eyes, respectively. The magnitude and the axis orientation of posterior corneal astigmatism were not constant, especially in eyes having high ATR anterior corneal astigmatism, as is often the case in patients who have undergone toric IOL implantation.  相似文献   

6.

Purpose

To test a pseudophakic eye model that allows for intraocular lens power (IOL) calculation, both in normal eyes and in extreme conditions, such as post-LASIK.

Methods

Participants: The model’s efficacy was tested in 54 participants (104 eyes) who underwent LASIK and were assessed before and after surgery, thus allowing to test the same method in the same eye after only changing corneal topography.

Modelling

The Liou-Brennan eye model was used as a starting point, and biometric values were replaced by individual measurements. Detailed corneal surface data were obtained from topography (Orbscan®) and a grid of elevation values was used to define corneal surfaces in an optical ray-tracing software (Zemax®). To determine IOL power, optimization criteria based on values of the modulation transfer function (MTF) weighted according to contrast sensitivity function (CSF), were applied.

Results

Pre-operative refractive assessment calculated by our eye model correlated very strongly with SRK/T (r = 0.959, p<0.001) with no difference of average values (16.9±2.9 vs 17.1±2.9 D, p>0.05). Comparison of post-operative refractive assessment obtained using our eye model with the average of currently used formulas showed a strong correlation (r = 0.778, p<0.001), with no difference of average values (21.5±1.7 vs 21.8±1.6 D, p>0.05).

Conclusions

Results suggest that personalized pseudophakic eye models and ray-tracing allow for the use of the same methodology, regardless of previous LASIK, independent of population averages and commonly used regression correction factors, which represents a clinical advantage.  相似文献   

7.

Purpose

To investigate the association between maternal reproductive age and their children’ refractive error progression in Chinese urban students.

Methods

The Beijing Myopia Progression Study was a three-year cohort investigation. Cycloplegic refraction of these students at both baseline and follow-up vision examinations, as well as non-cycloplegic refraction of their parents at baseline, were performed. Student’s refractive change was defined as the cycloplegic spherical equivalent (SE) of the right eye at the final follow-up minus the cycloplegic SE of the right eye at baseline.

Results

At the final follow-up, 241 students (62.4%) were reexamined. 226 students (58.5%) with completed refractive data, as well as completed parental reproductive age data, were enrolled. The average paternal and maternal age increased from 29.4 years and 27.5 years in 1993–1994 to 32.6 years and 29.2 years in 2003–2004, respectively. In the multivariate analysis, students who were younger (β = 0.08 diopter/year/year, P<0.001), with more myopic refraction at baseline (β = 0.02 diopter/year/diopter, P = 0.01), and with older maternal reproductive age (β = -0.18 diopter/year/decade, P = 0.01), had more myopic refractive change. After stratifying the parental reproductive age into quartile groups, children with older maternal reproductive age (trend test: P = 0.04) had more myopic refractive change, after adjusting for the children''s age, baseline refraction, maternal refraction, and near work time. However, no significant association between myopic refractive change and paternal reproductive age was found.

Conclusions

In this cohort, children with older maternal reproductive age had more myopic refractive change. This new risk factor for myopia progression may partially explain the faster myopic progression found in the Chinese population in recent decades.  相似文献   

8.

Objective

Dogs, like humans, experience eye changes with aging: hardening and clouding of the lens and accumulated oxidative damage from UV sunlight. It has been debated whether such changes could be affecting the visual function of dogs. The objective of this study was to determine if autorefractometry could be used to measure visual function in dogs.

Animals and Methods

Nine Beagle dogs (ages 1 to 14 years) were examined by a veterinary ophthalmologist and their eyes determined to be free of cataracts. Spherical equivalent refractive error was measured by handheld autorefractor (Welch Allyn SureSight) under both indirect and direct lighting conditions with five measurements per condition, per eye. Measures were repeated on three different days for each dog within six weeks. Nonparametric statistics were used to detect differences among lighting conditions and test days, and between eyes. Spearmen correlation assessed the visual measurement outcomes’ association with age.

Results

There was no difference for day-to-day or between-eye measurements. Significantly, the Beagles showed a myopic shift with aging (average spherical equivalent ranged from plano to -3.00 diopters), suggesting that dogs become more near-sighted as they age (r = -0.48 and -0.73 under direct and indirect lights; p<0.05 both). Younger dogs were able to make larger accommodation changes from indirect light to direct light conditions, indicating a more flexible lens (r = -0.50, p<0.05).

Conclusions

Although designed for humans, the hand-held autorefractor technique is applicable to dogs and sensitive to light conditions. The age-associated myopic shift could be expected to compromise dogs’ visual functions.  相似文献   

9.

Objective

To determine six-year spherical refractive error change among white children and young adults in the UK and evaluate differences in refractive profiles between contemporary Australian children and historical UK data.

Design

Population-based prospective study.

Participants

The Northern Ireland Childhood Errors of Refraction (NICER) study Phase 1 examined 1068 children in two cohorts aged 6–7 years and 12–13 years. Prospective data for six-year follow-up (Phase 3) are available for 212 12–13 year olds and 226 18–20 year olds in each cohort respectively.

Methods

Cycloplegic refractive error was determined using binocular open-field autorefraction (Shin-Nippon NVision-K 5001, cyclopentolate 1%). Participants were defined by spherical equivalent refraction (SER) as myopic SER ≤-0.50D, emmetropic -0.50D<SER<+2.00 or hyperopic SER≥+2.00D.

Main Outcome Measures

Proportion and incidence of myopia.

Results

The proportion of myopes significantly increased between 6–7 years (1.9%) and 12–13 years (14.6%) (p<0.001) but not between 12–13 and 18–20 years (16.4% to 18.6%, p = 0.51). The estimated annual incidence of myopia was 2.2% and 0.7% for the younger and older cohorts respectively. There were significantly more myopic children in the UK at age 12–13 years in the NICER study (16.4%) than reported in Australia (4.4%) (p<0.001). However by 17 years the proportion of myopia neared equivalence in the two populations (NICER 18.6%, Australia 17.7%, p = 0.75). The proportion of myopic children aged 12–13 years in the present study (2006–2008) was 16.4%, significantly greater than that reported for children aged 10–16 years in the 1960’s (7.2%, p = 0.01). The proportion of hyperopes in the younger NICER cohort decreased significantly over the six year period (from 21.7% to 14.2%, p = 0.04). Hyperopes with SER ≥+3.50D in both NICER age cohorts demonstrated persistent hyperopia.

Conclusions

The incidence and proportion of myopia are relatively low in this contemporary white UK population in comparison to other worldwide studies. The proportion of myopes in the UK has more than doubled over the last 50 years in children aged between 10–16 years and children are becoming myopic at a younger age. Differences between the proportion of myopes in the UK and in Australia apparent at 12–13 years were eliminated by 17 years of age.  相似文献   

10.

Purpose

To evaluate the effectiveness of Spot photoscreener in detecting amblyopia risk factors meeting 2013 the American Association of Pediatric Ophthalmology and Strabismus (AAPOS) criteria in Chinese preschool and school-age children.

Methods

One hundred and fifty-five children (310 eyes), aged between 4 to 7 years (5.74 ± 1.2 years) underwent complete ophthalmologic examination, photoscreening, and cycloplegic retinoscopy refraction. The agreement of the results obtained with the photoscreening and retinoscopy was evaluated by linear regression and Bland-Altman plots. The sensitivity and specificity of detecting amblyopia risk factors were calculated based on the AAPOS 2013 guidelines. The overall effectiveness of detecting amblyopia risk factors was analyzed with Receiver Operating Characteristic (ROC) curves.

Result

The mean refractive errors measured with the Spot were: spherical equivalent (SE) = 0.70 ± 1.99 D, J0 = 0.87 ± 1.01 D, J45 = 0.09 ± 0.60 D. The mean results from retinoscopy were: SE = 1.19 ± 2.22 D, J0 = 0.77 ± 1.00 D, J45 = -0.02 ± 0.45 D. There was a strong linear agreement between results obtained from those two methods (R2 = 0.88, P<0.01). Bland–Altman plot indicated a moderate agreement of cylinder values between the two methods. Based on the criteria specified by the AAPOS 2013 guidelines, the sensitivity and specificity (in respective order) for detecting hyperopia were 98.31% and 97.14%; for detecting myopia were 78.50% and 88.64%; for detecting astigmatism were 90.91% and 80.37%; for detecting anisometropia were 93.10% and 85.25%; and for detection of strabismus was 77.55% and 88.18%.

Conclusion

The refractive values measured from Spot photoscreener showed a moderate agreement with the results from cycloplegic retinoscopy refraction, however there was an overall myopic shift of -0.49D. The performance in detecting individual amblyopia risk factors was satisfactory, but could be further improved by optimizing criteria based on ROC curves.  相似文献   

11.

Objective

To evaluate changes in corneal astigmatism in patients undergoing orbital decompression surgery.

Methods

This retrospective, non randomized comparative study involved 42 eyes from 21 patients with thyroid ophthalmopathy who underwent orbital decompression surgery between September 2011 and September 2014. The 42 eyes were divided into three groups: control (9 eyes), two-wall decompression (25 eyes), and three-wall decompression (8 eyes). The control group was defined as the contralateral eyes of nine patients who underwent orbital decompression surgery in only one eye. Corneal topography (Orbscan II), Hertel exophthalmometry, and intraocular pressure were measured at 1 month before and 3 months after surgery. Corneal topographic parameters analyzed were total astigmatism (TA), steepest axis (SA), central corneal thickness (CCT), and anterior chamber depth (ACD).

Results

Exophthalmometry values and intraocular pressure decreased significantly after the decompression surgery. The change (absolute value (|x|) of the difference) in astigmatism at the 3 mm zone was significantly different between the decompression group and the controls (p = 0.025). There was also a significant change in the steepest axis at the 3 mm zone between the decompression group and the controls (p = 0.033). An analysis of relevant changes in astigmatism showed that there was a dominant tendency for incyclotorsion of the steepest axis in eyes that underwent decompression surgery. Using Astig PLOT, the mean surgically induced astigmatism (SIA) was 0.21±0.88 D with an axis of 46±22°, suggesting that decompression surgery did change the corneal shape and induced incyclotorsion of the steepest axis.

Conclusions

There was a significant change in corneal astigmatism after orbital decompression surgery and this change was sufficient to affect the optical function of the cornea. Surgeons and patients should be aware of these changes.  相似文献   

12.

Purpose

A primary task of the eye care professional is determining the refraction, or optical correction, of a patient. The duochrome red-green test is a standard tool for verification of the final refraction. Traditionally, it is recommended for use both prior to and subsequent to determining the cylindrical or astigmatic component of the refraction. In order for it to be effective when used before correcting the cylinder it is necessary that the COLC (Circle of Least Confusion) be on the retina. This study examined whether it is necessarily true that the duochrome response in uncorrected astigmatism will be as trust-worthy as it is with corrected cylinders.

Methods

The red-green examination was performed monocularly under the following three conditions: a. fully corrected refraction for the subgroup of eyes that had spherical refractions and for the subgroup of eyes with sphero-cylindrical refractions. b. best sphere-only correction without cylinder correction in sphero-cylindrical eyes c. an induced cylinder error in spherical eyes. The interval between the last “red” response and the first “green” response for the right eyes as a group and separately for the physiological cylinder and induced cylinder correction sub-groups was calculated and compared using a paired, two-tailed t-test.

Results

The intervals between “red” and “green” responses were not significantly different in the population as a whole and in the uncorrected physiological cylinder and induced cylinder subgroups examined.

Conclusion

Based on the finding that the interval of red-green equality with fully corrected cylinder and without the cylindrical correction are not significantly different, the red-green duochrome test can indeed be used both before and after cylindrical correction.  相似文献   

13.

Aims

To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA)

Methods

MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in this study.

Results

17 patients fulfilled the inclusion criterion. In all 17 patients IOP measurements were performed with RT (34 eyes) and ORA (33 eyes), while PAT measurement was possible in only 12 (24 eyes) patients. The RT, corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) differed relevantly from IOP assessed with PAT. Corneal clouding in MPS patients correlated positively with PAT, RT and IOPg (r = 0.3, 0.5, and 0.5 respectively), but not with IOPcc (r = 0.07). The MPS-related corneal clouding correlated positively with biomechanical corneal parameters assessed with ORA: corneal hysteresis (r = 0.77) and corneal resistance factor (r = 0.77) either.

Conclusions

RT and ORA measurements were tolerated better than applanation tonometry in MPS patients. IOP measurements assessed with RT and ORA differed relevantly from PAT. Corneal-compensated IOP assessed with ORA seems to be less affected by the MPS-related corneal clouding than applanation or rebound tonometry. RT and ORA measurements should be preferred for IOP assessment in patients with MPS.  相似文献   

14.

Purpose

To compare the anterior chamber depth (ACD), keratometry (K) and astigmatism measurements taken by IOLMaster and Pentacam HR in normal and high myopic (HM) eyes.

Design

A prospective observational case series.

Methods

Sixty-six normal eyes and 59 HM eyes underwent ACD, keratometry and astigmatism measurements with both devices. Axial length (AL) was measured on IOLMaster. The interdevice agreement was evaluated using the Bland-Altman analysis and paired t-test. The correlations between age and AL & ACD were analyzed. Vector analysis was used to compare astigmatism measurements.

Results

The ACD from IOLMaster and Pentacam HR was different for the normal group (P = 0.003) but not for the HM group (P = 0.280). IOLMaster demonstrated higher steep K and mean K values than Pentacam HR for both normal and HM groups (P<0.001 for all). IOLMaster also have higher flat K values for the HM groups (P<0.001) but were statistically equivalent with Pentacam HR for the normal group (P = 0.119) IOLMaster and Pentacam HR were different in astigmatism measurements for the normal group but were statistically equivalent for the HM group. For the normal group, age was negatively correlated with AL, IOLMaster ACD and Pentacam HR ACD (r = -0.395, P = 0.001; r = -0.715, P < 0.001; r = -0.643, P < 0.001). For the HM group, age was positively correlated with AL but negatively correlated with IOLMaster ACD and Pentacam HR ACD (r = 0.377, P = 0.003; r = -0.392, P = 0.002; r = -0.616, P < 0.001).

Conclusions

The IOLMaster and Pentacam HR have significant difference in corneal power measurements for both normal and HM groups. The two instruments also differ in ACD and astigmatism measurement for the normal group. Therefore, a single instrument is recommended for studying longitudinal changes in anterior segment biometric measurements. Age should be considered as an influencing factor for both AL and ACD values in the normal and HM group.  相似文献   

15.

Purpose

To investigate the changes of posterior corneal elevation after small incision lenticule extraction (SMILE) for moderate and high myopia.

Methods

In this prospective study, fifty consecutive eyes of thirty patients (10 male, 20 female) who underwent SMILE for myopia and myopic astigmatism were included. Eyes were divided in two groups based on the preoperative spherical equivalent refraction: high myopia group (32 eyes, range -6.25D to -10.00D) and moderate myopia group (18 eyes, range -3.00D to -6.00D). Posterior corneal surfaces were measured by a Scheimpflug camera (Pentacam, Oculus Germany) preoperatively and 1 month, 3 months, 6 months and 12 months postoperatively. Posterior central elevation (PCE) and posterior mean elevation (PME) at 17 predetermined points in the central-4mm area above the best-fit sphere were analyzed.

Results

No significant difference in the amount of posterior corneal elevation changes in the high myopia group was noted over time (P = 0.23 and P = 0.94 for PCE and PME, respectively). Similarly, the changes in the moderate myopia group before and after SMILE were not significant either (P = 0.34 and P = 0.40 for PCE and PME). A statistically significant correlation was found between the residual bed thickness and the shift of the PCE in the high myopia group at 12 months postoperatively (r = 0.53, P = 0.01).

Conclusions

The results of this study suggest that the posterior corneal surface remain stable within one year after SMILE for both moderate and high myopia. The changes of PCE correlate to the residual bed thickness for high myopia. Long-term changes of posterior corneal surface need further investigation.  相似文献   

16.
The purpose of this study is to develop a 3D patient-specific finite element model (FEM) of the cornea and sclera to compare predicted and in vivo refractive outcomes and to estimate the corneal elastic property changes associated with each procedure. Both eyes of a patient who underwent laser-assisted in situ keratomileusis (LASIK) for myopic astigmatism were modeled. Pre- and postoperative Scheimpflug anterior and posterior corneal elevation maps were imported into a 3D corneo-scleral FEM with an unrestrained limbus. Preoperative corneal hyperelastic properties were chosen to account for meridional anisotropy. Inverse FEM was used to determine the undeformed corneal state that produced <0.1% error in anterior elevation between simulated and in vivo preoperative geometries. Case-specific 3D aspheric ablation profiles were simulated, and corneal topography and spherical aberration were compared at clinical intraocular pressure. The magnitude of elastic weakening of the residual corneal bed required to maximize the agreement with clinical axial power was calculated and compared with the changes in ocular response analyzer (ORA) measurements. The models produced curvature maps and spherical aberrations equivalent to in vivo measurements. For the preoperative property values used in this study, predicted elastic weakening with LASIK was as high as 55% for a radially uniform model of residual corneal weakening and 65% at the point of maximum ablation in a spatially varying model of weakening. Reductions in ORA variables were also observed. A patient-specific FEM of corneal refractive surgery is presented, which allows the estimation of surgically induced changes in corneal elastic properties. Significant elastic weakening after LASIK was required to replicate clinical topographic outcomes in this two-eye pilot study.  相似文献   

17.

Purpose

Refraction in the peripheral visual field is believed to play an important role in the development of myopia. The purpose of this study was to investigate the differences in peripheral refraction among anisomyopia, isomyopia, and isoemmetropia for schoolchildren.

Methods

Thirty-eight anisomyopic children were recruited and divided into two groups: (1) both eyes were myopic (anisomyopic group, AM group) and (2) one eye was myopic and the contralateral eye was emmetropic (emmetropic anisomyopic group, EAM group). As controls, 45 isomyopic and isoemmetropic children were also recruited with age and central spherical equivalent (SE) matched to those of the AM and EAM groups. The controls were divided into three groups: (1) intermediate myopia group (SE matched to the more myopic eye of AM group), (2) low myopia group (SE matched to the less myopic eye of AM group and the more myopic eye of EAM group), and (3) emmetropia group (SE matched to the less myopic eye of EAM group). Peripheral refraction at 7 points across the central ±30° on the horizontal visual field with a 10° interval was measured with an autorefractor. Axial length (AL), corneal curvature (CC), and anterior chamber depth (ACD) were also determined by using the Zeiss IOL-Master.

Results

The relative peripheral spherical equivalent [RPR(M)] and relative peripheral spherical value [RPR(S)] of the more myopic eye was shifted more hyperopically than the contralateral eye in both the AM and the EAM groups (both p<0.0001). The RPR(M, S) of the less myopic eyes in the AM and EAM groups showed a relatively flat trend across the visual field and were not significantly different from the emmetropia group. The RPR(M, S) of less myopic eyes in the AM group were shifted less hyperopically than in the isomyopic low myopia group and the more myopic eye of the EAM group [RPR(M), p = 0.007; RPR(S), p = 0.001], although the central SEs of the three groups were not significantly different from each other. However, RPR(M, S) of the more myopic eyes were not different from the corresponding isomyopic groups. There was also no significant difference in the relative peripheral astigmatism [RPR(J0, J45)] between the more and the less myopic eyes in either the AM or the EAM group.

Conclusion

Refraction of anisomyopia differs between the two eyes not only at the central visual field but also at the off-axis periphery. The relative peripheral refraction of the more myopic eye of anisomyopia was shifted hyperopically, as occurs in isomyopia with similar central subjective SE values. Less myopic eyes were much less hyperopically shifted in relative peripheral refraction than the corresponding isomyopic eyes, but are comparable to emmetropic eyes. This emmetropia-like relative peripheral refraction in less myopic eyes might be a factor responsible for slowing down the progression of myopia.  相似文献   

18.

Background

The visual system adjusts to changes in the environment, as well as to changes within the observer, adapting continuously to maintain a match between visual coding and visual environment. We evaluated whether the perception of oriented blur is biased by the native astigmatism, and studied the time course of the after-effects following spectacle correction of astigmatism in habitually non-corrected astigmats.

Methods and Findings

We tested potential shifts of the perceptual judgments of blur orientation in 21 subjects. The psychophysical test consisted on a single interval orientation identification task in order to measure the perceived isotropic point (astigmatism level for which the image did not appear oriented to the subject) from images artificially blurred with constant blur strength (B = 1.5 D), while modifying the orientation of the blur according to the axis of natural astigmatism of the subjects. Measurements were performed after neutral (gray field) adaptation on naked eyes under full correction of low and high order aberrations. Longitudinal measurements (up to 6 months) were performed in three groups of subjects: non-astigmats and corrected and uncorrected astigmats. Uncorrected astigmats were provided with proper astigmatic correction immediately after the first session. Non-astigmats did not show significant bias in their perceived neutral point, while in astigmatic subjects the perceived neutral point was significantly biased, typically towards their axis of natural astigmatism. Previously uncorrected astigmats shifted significantly their perceived neutral point towards more isotropic images shortly (2 hours) after astigmatic correction wear, and, once stabilized, remained constant after 6 months. The shift of the perceived neutral point after correction of astigmatism was highly correlated with the amount of natural astigmatism.

Conclusions

Non-corrected astigmats appear to be naturally adapted to their astigmatism, and astigmatic correction significantly changes their perception of their neutral point, even after a brief period of adaptation.  相似文献   

19.

Purpose

To evaluate intraocular lens (IOL) tilt and decentration by anterior segment optical coherence tomography (AS-OCT) using 3-dimensional (3D) reconstruction method.

Design

Prospective observational case series.

Participants

Thirty-nine patients (39 eyes) were included.

Methods

The IOL positions of all eyes were examined by AS-OCT. Images were obtained in 4 axes (0–180 degrees, 45–225 degrees, 90–270 degrees, and 135–315 degrees) using the quadrant-scan model. The cross-sectional images were analyzed with MATLAB software.

Main Outcome Measures

The angle (θ) between the reference pupillary plane and the IOL plane, the distances between the center points of the pupil circle and the IOL on the x-axis (dx) and y-axis (dy) and the spatial distance (ds) were calculated after 3D-reconstruction.

Results

The mean angle (θ) between the pupillary plane and the IOL plane was 2.94±0.99 degrees. The mean IOL decentration of dx and dy was 0.32±0.26 mm and 0.40±0.27 mm, respectively. The ds of the IOL decentration was 0.56±0.31 mm. There was no significant correlation between the ocular residual astigmatism (ORA) and the tilted angle or the decentration distance. There was a significant correlation between the ORA and total astigmatism (r = 0.742, P<0.001). There was no significant correlation between the postoperative best corrected visual acuity (BCVA) and the ORA (r = 0.156; P = 0.344), total astigmatism (r = 0.012; P = 0.942), tilted angle (θ; r = 0.172; P = 0.295) or decentration distance (dx: r = 0.191, P = 0.244; dy: r = 0.253, P = 0.121; ds: r = 0.298, P = 0.065).

Conclusions

AS-OCT can be used as an alternative for the analysis of IOL tilt and decentration using 3D-reconstruction.  相似文献   

20.

Purpose

To assess the clinical outcomes of femtosecond laser-assisted keratoplasty (FLAK) using the VisuMax femtosecond laser system, and to compare them with those of conventional penetrating keratoplasty (PK).

Methods

We retrospectively examined 20 eyes of 20 consecutive patients undergoing FLAK and 20 eyes of 20 age- and diagnosis-matched patients undergoing conventional PK. We quantitatively assessed corneal astigmatism, refractive astigmatism, and corrected visual acuity, 1, 3, and 6 months postoperatively, and endothelial cell density 6 months postoperatively.

Results

Corneal and refractive astigmatism after FLAK were significantly lower after FLAK than that after conventional PK at 3 and 6 months postoperatively (p = 0.04 and p = 0.03, respectively, Mann-Whitney U test). FLAK provided significantly faster visual recovery than conventional PK at 1 month postoperatively (p = 0.02), but not at 3 and 6 months postoperatively (p = 0.52 and p = 0.80, respectively). We found no significant differences in the change in endothelial cell density between the two groups (p = 0.30).

Conclusions

FLAK using the VisuMax femtosecond laser system induces significantly less corneal and refractive astigmatism than conventional PK, and provides significantly faster visual recovery in the early postoperative period, possibly because the geometry of the donor-recipient matching is more physiological and requires less tight sutures. It is suggested that FLAK has advantages over conventional PK, in terms of astigmatism and fast visual recovery.  相似文献   