首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Desorption of three oral bacterial strains from a salivary conditioning film on an indium tin oxide electrode during application of a positive (bacterial adhesion to the anode) or a negative electric current was studied in a parallel plate flow chamber. Bacterial adhesion was from a flowing suspension of high ionic strength, after which the bacterial suspension was replaced by a low ionic strength solution without bacteria and currents ranging from -800 to +800 microA were applied. Streptococcus oralis J22 desorbed during application of a positive and negative electric current with a desorption probability that increased with increasing electric current. Two actinomyces strains, however, could not be stimulated to desorb by the electric currents applied. The desorption forces acting on adhering bacteria are electroosmotic in origin and working parallel to the electrode surface in case of a positive current, whereas they are electrophoretic and electrostatic in origin and working perpendicular to the surface in case of a negative current. By comparison of the effect of positive and negative electric currents, it can be concluded that parallel forces are more effective in stimulating bacterial desorption than perpendicular forces. The results of this study point to a new pathway of cleaning industrial and biomedical surfaces without the use of detergents or biocides.  相似文献   

2.
Biomaterial-centered infections of orthopedic percutaneous implants are serious complications which can ultimately lead to osteomyelitis, with devastating effects on bone and surrounding tissues, especially since the biofilm mode of growth offers protection against antibiotics and since removal frequently is the only ultimate solution. Recently, it was demonstrated that as a possible pathway to prevent infections of percutaneous stainless steel implants, electric currents of 60 to 100 microA were effective at stimulating the detachment of initially adhering staphylococci from surgical stainless steel. However, initially adhering bacteria are known to adhere more reversibly than bacteria growing in the later stages of biofilm formation. Hence, the aim of this study was to examine whether a growing Staphylococcus epidermidis biofilm can be stimulated to detach from surgical stainless steel by the use of electric currents. In separate experiments, four currents, i.e., 60 and 100 microA of direct current (DC) and 60 and 100 microA of block current (50% duty cycle, 1 Hz), were applied for 360 min to stimulate the detachment of an S. epidermidis biofilm that had grown for 200 min. A 100-microA DC yielded 78% detachment, whereas a 100-microA block current under the same experimental conditions yielded only 31% detachment. The same trend was found for 60 microA, with 37% detachment for a DC and 24% for a block current. Bacteria remaining on the surface after the current application were less viable than they were prior to the current application, as demonstrated by confocal laser scanning microscopy. In conclusion, these results suggest that DCs are preferred for curing infections.  相似文献   

3.
The change in cell surface properties in the presence of electric currents is of critical concern when the potential to manipulate bacterial movement with electric fields is evaluated. In this study, the effects of different direct electric currents on the cell surface properties involved in bacterial adhesion were investigated by using a mixed phenol-degrading bacterial culture in the exponential growth phase. The traits investigated were surface hydrophobicity (measured by adherence to n-octane), net surface electrostatic charge (determined by measurement of the zeta potential), and the cell surface shape and polymers (determined by scanning electron microscope analysis). The results showed that a lower current (less than 20 mA) induced no significant changes in the surface properties of phenol-degrading bacteria, that an electric current of 20 mA could increase the surface hydrophobicity and flatten the cell shape, and that a higher current (40 mA) could increase the surface extracellular substances and the net negative surface electrostatic charge. The results also revealed that the electric current effects on cell hydrophobicity varied with the suspending medium. We suggest that an electric current greater than 20 mA is not suitable for use in manipulation of the movement of the phenol-degrading bacteria, although such a current might favor the electrophoretic movement of the bacterial species.  相似文献   

4.
The change in cell surface properties in the presence of electric currents is of critical concern when the potential to manipulate bacterial movement with electric fields is evaluated. In this study, the effects of different direct electric currents on the cell surface properties involved in bacterial adhesion were investigated by using a mixed phenol-degrading bacterial culture in the exponential growth phase. The traits investigated were surface hydrophobicity (measured by adherence to n-octane), net surface electrostatic charge (determined by measurement of the zeta potential), and the cell surface shape and polymers (determined by scanning electron microscope analysis). The results showed that a lower current (less than 20 mA) induced no significant changes in the surface properties of phenol-degrading bacteria, that an electric current of 20 mA could increase the surface hydrophobicity and flatten the cell shape, and that a higher current (40 mA) could increase the surface extracellular substances and the net negative surface electrostatic charge. The results also revealed that the electric current effects on cell hydrophobicity varied with the suspending medium. We suggest that an electric current greater than 20 mA is not suitable for use in manipulation of the movement of the phenol-degrading bacteria, although such a current might favor the electrophoretic movement of the bacterial species.  相似文献   

5.
Biomaterial-centered infections of orthopedic percutaneous implants are serious complications which can ultimately lead to osteomyelitis, with devastating effects on bone and surrounding tissues, especially since the biofilm mode of growth offers protection against antibiotics and since removal frequently is the only ultimate solution. Recently, it was demonstrated that as a possible pathway to prevent infections of percutaneous stainless steel implants, electric currents of 60 to 100 μA were effective at stimulating the detachment of initially adhering staphylococci from surgical stainless steel. However, initially adhering bacteria are known to adhere more reversibly than bacteria growing in the later stages of biofilm formation. Hence, the aim of this study was to examine whether a growing Staphylococcus epidermidis biofilm can be stimulated to detach from surgical stainless steel by the use of electric currents. In separate experiments, four currents, i.e., 60 and 100 μA of direct current (DC) and 60 and 100 μA of block current (50% duty cycle, 1 Hz), were applied for 360 min to stimulate the detachment of an S. epidermidis biofilm that had grown for 200 min. A 100-μA DC yielded 78% detachment, whereas a 100-μA block current under the same experimental conditions yielded only 31% detachment. The same trend was found for 60 μA, with 37% detachment for a DC and 24% for a block current. Bacteria remaining on the surface after the current application were less viable than they were prior to the current application, as demonstrated by confocal laser scanning microscopy. In conclusion, these results suggest that DCs are preferred for curing infections.  相似文献   

6.
Shim S  Hong SH  Tak Y  Yoon J 《Biofouling》2011,27(2):217-224
The process of controlling bacterial adhesion using an electric current deserves attention because of its ease of automation and environmentally friendly nature. This study investigated the role of electric currents (negative, positive, alternating) for preventing adhesion of Pseudomonas aeruginosa and achieving bacterial inactivation. Indium tin oxide (ITO) film was used as a working electrode to observe adhesion and inactivation under electric polarization. Electric current types were classified into negative, positive, and alternating current. The working electrode acted as a cathode or anode by applying a negative or positive current, and an alternating current indicates that the negative current was combined sequentially with the positive current. The numbers of adhered cells were compared under a flow condition, and the in situ behavior of the bacterial cells and the extent of their inactivation were also investigated using time-lapse recording and live/dead staining, respectively. The application of a negative current prevented bacterial adhesion significantly (~81% at 15.0 μA cm(-2)). The positive current did not significantly inhibit adhesion (<20% at 15.0 μA cm(-2)), compared to the nonpolarized case. The alternating current had a similar effect as the negative current on preventing bacterial adhesion, but it also exhibited bactericidal effects, making it the most suitable method for bacterial adhesion control.  相似文献   

7.
The process of controlling bacterial adhesion using an electric current deserves attention because of its ease of automation and environmentally friendly nature. This study investigated the role of electric currents (negative, positive, alternating) for preventing adhesion of Pseudomonas aeruginosa and achieving bacterial inactivation. Indium tin oxide (ITO) film was used as a working electrode to observe adhesion and inactivation under electric polarization. Electric current types were classified into negative, positive, and alternating current. The working electrode acted as a cathode or anode by applying a negative or positive current, and an alternating current indicates that the negative current was combined sequentially with the positive current. The numbers of adhered cells were compared under a flow condition, and the in situ behavior of the bacterial cells and the extent of their inactivation were also investigated using time-lapse recording and live/dead staining, respectively. The application of a negative current prevented bacterial adhesion significantly (~81% at 15.0 μA cm?2). The positive current did not significantly inhibit adhesion (<20% at 15.0 μA cm?2), compared to the nonpolarized case. The alternating current had a similar effect as the negative current on preventing bacterial adhesion, but it also exhibited bactericidal effects, making it the most suitable method for bacterial adhesion control.  相似文献   

8.
Low-level direct current (0.2–1.8 mA) was demonstrated to be an antitumor agent on two different murine tumor models (fibrosarcoma Sa-1 and melanoma B-16), and has been suggested for regional cancer treatment. Its antitumor effect was achieved by introduction of single or multiple–array needle electrodes (Pt-Ir alloy) in the tumor and (an)other electrode(s) subcutaneously in its vicinity. The electrode inserted in the tumor was made anodic (anodic electrotherapy, ET) or cathodic (cathodic ET). In control groups, animals were subjected to exactly the same procedures with needle electrodes inserted at usual sites without current. In single-stimulus ET performed after the tumors have reached approximately 50 mm3 in volume with 0.2, 0.6, and 1.O mA for 30, 60, and 90 min, cathodic ET exhibited better antitumor effect than anodic ET. In both cases and at all ET durations, the antitumor effect depended proportionally on the current level applied. The antitumor effect was evaluated by following tumor growth and by microscopic estimation of the necrotization of the tumor area immediately after ET, and 24, 48, and 72 h posttreatment.

Necrotization produced by cathodic ET was observed to be immediate and extensive whereas anodic ET resulted in increased necrotization only at 24 h posttreatment. In both cases the extent of necrosis was significantly higher than in control and was centrally located (site of electrode), whereas in controls it was sporadic, distributed randomly over the whole tumor area. When current was delivered via multiple–array electrode ET, the antitumor effect was slightly better in cathodic ET compared to single-electrode ET. Employing cathodic multiple-array electrode ET and using higher currents, i.e., 1.0, 1.4, and 1.8 mA in melanoma B-16, 20% and 40% cures were achieved by 1.4 and 1.8 mA single-shot ET of 1 h duration, respectively, whereas in fibrosarcoma Sa-1 no cures were accomplished. In general, different susceptibility of the two tumor models to ET was noticeable. Comparing tumor growth and necrotization after the application of direct current (0.6 mA) and alternating current (0.0 mA mean, 0.6 mA RMS), it appeared that alternating current had no impact either on necrotization of tumor tissue or on tumor growth. ET was performed on normal tissues as well. In subcutaneous tissue, thigh muscle, and liver of healthy mice immediately after 1 h of treatment using 0.6 mA in both cathodic and anodic modes, local necrotization at the site of electrode insertion was evident, with signs of acute inflammation in the vicinity. In anodic ET, vacuolization around the electrode was noticed.  相似文献   

9.
Franklin M  White DC  Little B  Ray R  Pope R 《Biofouling》2000,15(1-3):13-23
Pit propagation in carbon steel exposed to a phosphate-containing electrolyte required either stagnant conditions or microbial colonization of anodic regions. A scanning vibrating electrode (SVE) was used to resolve formation and inactivation of anodic and cathodic sites on carbon steel. In sterile, continuously aerated medium, pits initiated and repassivated, while in the absence of aeration, pits initiated and propagated. Pit propagation was also observed in continuously aerated medium inoculated with a heterotrophic bacterium, originally isolated from a corrosion tubercle formed on a steel pipe in a fresh water environment. Autoradiography of bacteria following uptake of (14)C-acetate into cellular material in combination with SVE analysis demonstrated that sites of anodic activity coincided with sites of bacterial activity. Prelabeled bacteria also preferentially attached to corrosion products over the anodic sites. Confocal laser scanning microscopy demonstrated that attraction to anodic sites did not depend on bacterial viability and was not specific for iron as a substratum. The results suggest that bacteria may preferentially attach to the corrosion products formed over corrosion pits. The biofilms over these anodic sites may create stagnant conditions within corrosion pits that result in pit propagation.  相似文献   

10.
In marine sediments cathodic oxygen reduction at the sediment surface can be coupled to anodic sulfide oxidation in deeper anoxic layers through electrical currents mediated by filamentous, multicellular bacteria of the Desulfobulbaceae family, the so-called cable bacteria. Until now, cable bacteria have only been reported from marine environments. In this study, we demonstrate that cable bacteria also occur in freshwater sediments. In a first step, homogenized sediment collected from the freshwater stream Giber Å, Denmark, was incubated in the laboratory. After 2 weeks, pH signatures and electric fields indicated electron transfer between vertically separated anodic and cathodic half-reactions. Fluorescence in situ hybridization revealed the presence of Desulfobulbaceae filaments. In addition, in situ measurements of oxygen, pH, and electric potential distributions in the waterlogged banks of Giber Å demonstrated the presence of distant electric redox coupling in naturally occurring freshwater sediment. At the same site, filamentous Desulfobulbaceae with cable bacterium morphology were found to be present. Their 16S rRNA gene sequence placed them as a distinct sister group to the known marine cable bacteria, with the genus Desulfobulbus as the closest cultured lineage. The results of the present study indicate that electric currents mediated by cable bacteria could be important for the biogeochemistry in many more environments than anticipated thus far and suggest a common evolutionary origin of the cable phenotype within Desulfobulbaceae with subsequent diversification into a freshwater and a marine lineage.  相似文献   

11.
Several anaerobic metal-reducing bacteria have been shown to be able to donate electrons directly to an electrode. This property is of great interest for microbial fuel cell development. To date, microbial fuel cell design requires avoiding O(2) diffusion from the cathodic compartment to the sensitive anodic compartment. Here, we show that Acidiphilium sp. strain 3.2 Sup 5 cells that were isolated from an extreme acidic environment are able to colonize graphite felt electrodes. These bacterial electrodes were able to produce high-density electrocatalytic currents, up to 3 A/m(2) at a poised potential of +0.15 V (compared to the value for the reference standard calomel electrode) in the absence of redox mediators, by oxidizing glucose even at saturating air concentrations and very low pHs.  相似文献   

12.
Recent progress in electrodes for microbial fuel cells   总被引:3,自引:0,他引:3  
Wei J  Liang P  Huang X 《Bioresource technology》2011,102(20):9335-9344
The performance and cost of electrodes are the most important aspects in the design of microbial fuel cell (MFC) reactors. A wide range of electrode materials and configurations have been tested and developed in recent years to improve MFC performance and lower material cost. As well, anodic electrode surface modifications have been widely used to improve bacterial adhesion and electron transfer from bacteria to the electrode surface. In this paper, a review of recent advances in electrode material and a configuration of both the anode and cathode in MFCs are provided. The advantages and drawbacks of these electrodes, in terms of their conductivity, surface properties, biocompatibility, and cost are analyzed, and the modification methods for the anodic electrode are summarized. Finally, to achieve improvements and the commercial use of MFCs, the challenges and prospects of future electrode development are briefly discussed.  相似文献   

13.
The literature shows that the effects of direct electric currents on biological material are numerous, including bactericidal, fungicidal, parasiticidal, and anti‐tumoral, among others. Non‐pathogenic trypanosomatids, such as Herpetomonas samuelpessoai, have emerged as important models for the study of basic biological processes performed by a eukaryotic cell. The present study reports a dose‐dependent anti‐protozoan effect of direct electric treatment with both cathodic and anodic current flows on H. samuelpessoai cells. The damaging effects can be attributable to the electrolysis products generated during electric stimulation. The pH of the cell suspension was progressively augmented from 7.4 to 10.5 after the cathodic treatment. In contrast, the anodic treatment caused a pH decrease varying from 7.4 to 6.5. Transmission electron microscopy analyses revealed profound alterations in vital cellular structures (e.g., mitochondrion, kinetoplast, flagellum, flagellar pocket, nucleus, and plasma membrane) after exposure to both cathodic and anodic current flows. Specifically, cathodic current flow treatment induced the appearance of autophagic‐like structures on parasite cells, while those submitted to an anodic current flow presented marked disorganization of plasma membrane and necrotic appearance. However, parasites treated in the intermediary chamber (without contact with the electrodes) did not present significant changes in viability or morphology, and no pH variation was detected in this system. The use of H. samuelpessoai as a biological model and the direct electric current experimental approach used in our study provide important information for understanding the mechanisms involved in the cytotoxic effects of this physical agent. Bioelectromagnetics 33:334–345, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

14.
Electrochemical impedance spectroscopy was tested to monitor the cell attachment and the biofilm proliferation in order to identify characteristic events induced on the metal surface by Gram-negative (Pseudomonas aeruginosa PAO1) and Gram-positive (Bacillus subtilis) bacteria strains. Electrochemical impedance spectra of AISI 304 electrodes during cell attachment and initial biofilm growth for both strains were obtained. It can be observed that the resistance increases gradually with the culture time and decreases with the biofilm detachment. So, the applicability of electric cell-substrate impedance sensing (ECIS) for studying the attachment and spreading of cells on a metal surface has been demonstrated. The biofilm formation was also characterized by the use of scanning electron microscopy and confocal laser scanning microscopy and COMSTAT image analysis. The electrochemical results roughly agree with the microscope image observations. The ECIS technique used in this study was used for continuous real-time monitoring of the initial bacterial adhesion and the biofilm growth. It provides a simple and non-expensive electrochemical method for in vitro assessment of the presence of biofilms on metal surfaces.  相似文献   

15.
In this study, we examine bacterial attachment and survival on a titanium (Ti) cathode coated with various carbon nanomaterials (CNM): pristine carbon nanotubes (CNT), oxidized carbon nanotubes (O-CNT), oxidized-annealed carbon nanotubes (OA-CNT), carbon black (CB), and reduced graphene oxide (rGO). The carbon nanomaterials were dispersed in an isopropyl alcohol-Nafion solution and were then used to dip-coat a Ti substrate. Pseudomonas fluorescens was selected as the representative bacterium for environmental biofouling. Experiments in the absence of an electric potential indicate that increased nanoscale surface roughness and decreased hydrophobicity of the CNM coating decreased bacterial adhesion. The loss of bacterial viability on the noncharged CNM coatings ranged from 22% for CB to 67% for OA-CNT and was dependent on the CNM dimensions and surface chemistry. For electrochemical experiments, the total density and percentage of inactivation of the adherent bacteria were analyzed semiquantitatively as functions of electrode potential, current density, and hydrogen peroxide generation. Electrode potential and hydrogen peroxide generation were the dominant factors with regard to short-term (3-h) bacterial attachment and inactivation, respectively. Extended-time electrochemical experiments (12 h) indicated that in all cases, the density of total deposited bacteria increased almost linearly with time and that the rate of bacterial adhesion was decreased 8- to 10-fold when an electric potential was applied. In summary, this study provides a fundamental rationale for the selection of CNM as cathode coatings and electric potential to reduce microbial fouling.  相似文献   

16.
The concept of micelle-supported electroenzymology is demonstrated using a system consisting of the membrane enzyme Escherichia coli fumarate reductase (FRD), the amphiphilic coenzyme analogue decylubiquinone (DU), the micelle-forming surfactant n-octyl glucoside (OG), and a gold electrode. The OG micelles provide a hydrophobic, membrane mimetic medium for FRD and DU to exchange electrons while the gold electrode serves to regenerate DU. When succinate is presented to the FRD/DU/OG micelle system, electroenzymatic oxidation of succinate to fumarate occurs as evidenced using cyclic voltammetry. DU is shown to be the only electroactive species in the system; and as increasing amounts of succinate are added, the expected increase in the peak anodic (oxidative) current and decrease in the peak cathodic (reductive) current are observed. The peak anodic current approaches a limiting value with succinate concentration in qualitative agreement with simple Michaelis-Menten enzyme kinetics. When the strong competitive inhibitor oxaloacetate is added, enzymatic oxidation of succinate is inhibited as indicated by no change in the peak anodic and cathodic currents with increasing succinate concentration. (c) 1993 John Wiley & Sons, Inc.  相似文献   

17.
Biofilm formed on carbon steel by various species of bacterial cells causes serious problems such as corrosion of steel, choking of flow in the pipe, deterioration of the heat-transfer efficiency, and so on. Cathodic protection is known to be a reliable method for protecting carbon steel from corrosion. However, the initial attachment of bacteria to the surface and the effects of cathodic protection on bacterial viability in the biofilm have not been clarified. In this study, cathodic protection was applied to an artificial biofilm containing Pseudomonas aeruginosa (PAO1), a biofilm constituent, on carbon steel. The aims of this study were to evaluate the inhibition effect of cathodic protection on biofilm formation and to reveal the inhibition mechanisms. The viability of PAO1 in artificial biofilm of 5 mm thickness on cathodically protected steel decreased to 1% of the initial cell concentration. Analysis of pH distribution in the artificial biofilm by pH microelectrode revealed that pH in proximity to carbon steel increased to approximately 11 after cathodic protection for 5 h. Moreover, 99% of region in the artificial biofilm was under the pH conditions of over nine. A simulation of pH profile was shown to correspond to experimental values. These results indicate cells in the artificial biofilm were killed or damaged by cathodic protection due to pH increase.  相似文献   

18.
Bacterial cell surface hydrophobicity is one of the most important factors that influence bacterial adhesion. A new method, microsphere adhesion to cells, for measuring bacterial cell surface hydrophobicity was developed. Microsphere adhesion to cells is based on microscopic enumeration of hydrophobic, fluorescent microspheres attaching to the bacterial surface. Cell surface hydrophobicity estimated by microsphere adhesion to cells correlates well with adhesion of bacteria to hydrocarbons or hydrophobic interaction chromatography for a set of hydrophilic and hydrophobic bacteria (linear correlation coefficients, R2, were 0.845 and 0.981 respectively). We also used microsphere adhesion to cells to investigate the in situ properties of individual free-living bacteria directly in activated sludge. Results showed that the majority of the bacteria were hydrophilic, indicating the importance of cell surface hydrophobicity for bacterial adhesion in sludge, and for the overall success of the wastewater treatment process.  相似文献   

19.
Receptor-mediated adhesion of bacteria to biological surfaces is a significant step leading to infection. Due to an increase in bacterial antibiotic resistance, novel methods to block and disrupt these specific interactions have gained considerable interest as possible therapeutic strategies. Recently, several monoclonal antibodies specific for the Staphylococcus aureus collagen receptor demonstrated specialized ability to displace attached cells from collagen in static assays. In this study, we experimentally examine the monoclonal antibody detachment functionality under physiological shear conditions to evaluate the role of this parameter in the detachment process. The detachment of staphylococci from collagen was quantified in real-time using a parallel plate flow chamber, phase contrast video-microscopy and digital image processing. The results demonstrate a unimodal dependence of detachment on fluid wall shear rate. The observed decrease in effective detachment rate with increasing force at the highest shear levels evaluated is counterintuitive and has not been previously demonstrated. Several possible mechanisms of this result are discussed.  相似文献   

20.
Four types of titanium (Ti)-based electrodes were tested in the same microbial fuel cell (MFC) anodic compartment. Their electrochemical performances and the dominant microbial communities of the electrode biofilms were compared. The electrodes were identical in shape, macroscopic surface area, and core material but differed in either surface coating (Pt- or Ta-coated metal composites) or surface texture (smooth or rough). The MFC was inoculated with electrochemically active, neutrophilic microorganisms that had been enriched in the anodic compartments of acetate-fed MFCs over a period of 4 years. The original inoculum consisted of bioreactor sludge samples amended with Geobacter sulfurreducens strain PCA. Overall, the Pt- and Ta-coated Ti bioanodes (electrode-biofilm association) showed higher current production than the uncoated Ti bioanodes. Analyses of extracted DNA of the anodic liquid and the Pt- and Ta-coated Ti electrode biofilms indicated differences in the dominant bacterial communities. Biofilm formation on the uncoated electrodes was poor and insufficient for further analyses. Bioanode samples from the Pt- and Ta-coated Ti electrodes incubated with Fe(III) and acetate showed several Fe(III)-reducing bacteria, of which selected species were dominant, on the surface of the electrodes. In contrast, nitrate-enriched samples showed less diversity, and the enriched strains were not dominant on the electrode surface. Isolated Fe(III)-reducing strains were phylogenetically related, but not all identical, to Geobacter sulfurreducens strain PCA. Other bacterial species were also detected in the system, such as a Propionicimonas-related species that was dominant in the anodic liquid and Pseudomonas-, Clostridium-, Desulfovibrio-, Azospira-, and Aeromonas-related species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号