首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Molecular beacons are stem-loop hairpin oligonucleotide probes labeled with a fluorescent dye at one end and a fluorescence quencher at the other end; they can differentiate between bound and unbound probes in homogeneous hybridization assays with a high signal-to-background ratio and enhanced specificity compared with linear oligonucleotide probes. However, in performing cellular imaging and quantification of gene expression, degradation of unmodified molecular beacons by endogenous nucleases can significantly limit the detection sensitivity, and results in fluorescence signals unrelated to probe/target hybridization. To substantially reduce nuclease degradation of molecular beacons, it is possible to protect the probe by substituting 2'-O-methyl RNA for DNA. Here we report the analysis of the thermodynamic and kinetic properties of 2'-O-methyl and 2'-deoxy molecular beacons in the presence of RNA and DNA targets. We found that in terms of molecular beacon/target duplex stability, 2'-O-methyl/RNA > 2'-deoxy/RNA > 2'-deoxy/DNA > 2'-O-methyl/DNA. The improved stability of the 2'-O-methyl/RNA duplex was accompanied by a slightly reduced specificity compared with the duplex of 2'-deoxy molecular beacons and RNA targets. However, the 2'-O-methyl molecular beacons hybridized to RNA more quickly than 2'-deoxy molecular beacons. For the pairs tested, the 2'-deoxy-beacon/DNA-target duplex showed the fastest hybridization kinetics. These findings have significant implications for the design and application of molecular beacons.  相似文献   

2.
Quantitation of poly(A)-RNA, time-dependent visualization of intracellular poly(A)(+)-RNA localization in living mammalian cells, and time-resolved intracellular binding dynamics of molecular beacons at the single-molecule level using a fluorescence resonance energy transfer (FRET)-based molecular beacon are described. FRET-based molecular beacons were designed as poly(A)-targeting probes to be oligonucleotides that contained Cy5 and Cy3 fluorescent dyes at the strand ends and a poly(A)-targeting sequence inside the strand. Our ratiometric analysis using poly(A)-targeting probes allowed for highly specific and wide-ranging detection (from 1.25nM to 0.5μM) of poly(A)-RNA, as well as for determination of K(d) values, and revealed a distribution of the probe itself and localization of the target RNA sequence in cells. Furthermore, time-dependent FRET-mediated fluorescence changes at the single-molecule level caused by the folding-induced gradual conformation changes in live cells were observed.  相似文献   

3.
We describe a method for the quantitative, real-time measurement of DNA glycosylase and AP endonuclease activities in cell nuclear lysates using base excision repair (BER) molecular beacons. The substrate (beacon) is comprised of a deoxyoligonucleotide containing a single base lesion with a 6-Carboxyfluorescein (6-FAM) moiety conjugated to the 5''end and a Dabcyl moiety conjugated to the 3'' end of the oligonucleotide. The BER molecular beacon is 43 bases in length and the sequence is designed to promote the formation of a stem-loop structure with 13 nucleotides in the loop and 15 base pairs in the stem1,2. When folded in this configuration the 6-FAM moiety is quenched by Dabcyl in a non-fluorescent manner via Förster Resonance Energy Transfer (FRET)3,4. The lesion is positioned such that following base lesion removal and strand scission the remaining 5 base oligonucleotide containing the 6-FAM moiety is released from the stem. Release and detachment from the quencher (Dabcyl) results in an increase of fluorescence that is proportionate to the level of DNA repair. By collecting multiple reads of the fluorescence values, real-time assessment of BER activity is possible. The use of standard quantitative real-time PCR instruments allows the simultaneous analysis of numerous samples. The design of these BER molecular beacons, with a single base lesion, is amenable to kinetic analyses, BER quantification and inhibitor validation and is adaptable for quantification of DNA Repair activity in tissue and tumor cell lysates or with purified proteins. The analysis of BER activity in tumor lysates or tissue aspirates using these molecular beacons may be applicable to functional biomarker measurements. Further, the analysis of BER activity with purified proteins using this quantitative assay provides a rapid, high-throughput method for the discovery and validation of BER inhibitors.  相似文献   

4.
We have developed a novel high-throughput screening assay of hepatitis C virus (HCV) nonstructural protein 3 (NS3) helicase inhibitors using the fluorescence-quenching phenomenon via photoinduced electron transfer between fluorescent dyes and guanine bases. We prepared double-stranded DNA (dsDNA) with a 5′-fluorescent-dye (BODIPY FL)-labeled strand hybridized with a complementary strand, the 3′-end of which has guanine bases. When dsDNA is unwound by helicase, the dye emits fluorescence owing to its release from the guanine bases. Our results demonstrate that this assay is suitable for quantitative assay of HCV NS3 helicase activity and useful for high-throughput screening for inhibitors. Furthermore, we applied this assay to the screening for NS3 helicase inhibitors from cell extracts of microorganisms, and found several cell extracts containing potential inhibitors.  相似文献   

5.
6.
Molecular beacons are stem–loop hairpin oligonucleotide probes labeled with a fluorescent dye at one end and a fluorescence quencher at the other end; they can differentiate between bound and unbound probes in homogeneous hybridization assays with a high signal-to-background ratio and enhanced specificity compared with linear oligonucleotide probes. However, in performing cellular imaging and quantification of gene expression, degradation of unmodified molecular beacons by endogenous nucleases can significantly limit the detection sensitivity, and results in fluorescence signals unrelated to probe/target hybridization. To substantially reduce nuclease degradation of molecular beacons, it is possible to protect the probe by substituting 2′-O-methyl RNA for DNA. Here we report the analysis of the thermodynamic and kinetic properties of 2′-O-methyl and 2′-deoxy molecular beacons in the presence of RNA and DNA targets. We found that in terms of molecular beacon/target duplex stability, 2′-O-methyl/RNA > 2′-deoxy/RNA > 2′-deoxy/DNA > 2′-O-methyl/DNA. The improved stability of the 2′-O-methyl/RNA duplex was accompanied by a slightly reduced specificity compared with the duplex of 2′-deoxy molecular beacons and RNA targets. However, the 2′-O-methyl molecular beacons hybridized to RNA more quickly than 2′-deoxy molecular beacons. For the pairs tested, the 2′-deoxy-beacon/DNA-target duplex showed the fastest hybridization kinetics. These findings have significant implications for the design and application of molecular beacons.  相似文献   

7.
Molecular beacons as probes of RNA unfolding under native conditions   总被引:4,自引:0,他引:4  
Hybridization of fluorescent molecular beacons provides real-time detection of RNA secondary structure with high specificity. We used molecular beacons to measure folding and unfolding rates of the Tetrahymena group I ribozyme under native conditions. A molecular beacon targeted against 15 nt in the 5′ strand of the P3 helix specifically hybridized with misfolded forms of the ribozyme, without invading the native tertiary structure. The beacon associated with the misfolded ribozyme 300 times more slowly than with an unstructured oligonucleotide containing the same target sequence, suggesting that the misfolded ribozyme core remains structured in the absence of Mg2+. The rate of beacon hybridization under native conditions revealed a linear relationship between the free energy of unfolding and Mg2+ concentration. A small fraction of the RNA population unfolded very rapidly, suggesting parallel unfolding in one step or through misfolded intermediates.  相似文献   

8.
Traditional methods to assay enzymatic cleavage of DNA are discontinuous and time consuming. In contrast, recently developed fluorescence methods are continuous and convenient. However, no fluorescence method has been developed for single-stranded DNA digestion. Here we introduce a novel method, based on molecular beacons, to assay single-stranded DNA cleavage by single strand-specific nucleases. A molecular beacon, a hairpin-shaped DNA probe labeled with a fluorophore and a quencher, is used as the substrate and enzymatic cleavage leads to fluorescence enhancement in the molecular beacon. This method permits real time detection of DNA cleavage and makes it easy to characterize the activity of DNA nucleases and to study the steady-state cleavage reaction kinetics. The excellent sensitivity, reproducibility and convenience will enable molecular beacons to be widely useful for the study of single-stranded DNA cleaving reactions.  相似文献   

9.
Small molecule targeting of self-splicing RNAs like group I and II introns has been limited in part by the lack of a universal high-throughput screening platform for studies of splicing inhibition and kinetics. Here, we present the development of a molecular beacon assay for monitoring the accumulation of spliced exons during RNA splicing reactions. In this case, we applied it to the autocatalyzed reaction of the H.c.LSU group II intron found in the mitochondria of the pathogenic dimorphic fungus Histoplasma capsulatum. We find that a molecular beacon with the loop length of 18 nucleotides selectively recognizes ligated exons formed during self-splicing and exhibits high fluorescent signal upon binding of its target. We demonstrate that the fluorescent assay using molecular beacons can be successfully applied to kinetic characterization of the splicing reaction and determination of inhibition constants for small molecules. The results presented herein offer support for a molecular beacon approach to identifying small molecule inhibitors of intron splicing.  相似文献   

10.
While molecular beacons are primarily known as biosensors for the detection of nucleic acids, it has proven possible to adapt other nucleic acid binding species (aptamers) to function in a manner similar to molecular beacons, yielding fluorescent signals only in the presence of a cognate ligand. Unfortunately, engineering aptamer beacons requires a detailed knowledge of aptamer sequence and structure. In order to develop a general method for the direct selection of aptamer beacons we have first developed a selection method for molecular beacons. A pool of random sequence DNA molecules were immobilized via a capture oligonucleotide on an affinity column, and those variants that could be released from the column by a target oligonucleotide were amplified. After nine rounds of selection and amplification the elution characteristics of the population were greatly improved. A fluorescent reporter in the selected beacons was located adjacent to a DABCYL moiety in the capture oligonucleotide; addition of the target oligonucleotide led to release of the capture oligonucleotide and up to a 17-fold increase in fluorescence. Signaling was specific for the target oligonucleotide, and occurred via a novel mechanism, relative to designed molecular beacons. When the target oligonucleotide is bound it can form a stacked helical junction with an intramolecular hairpin in the selected beacon; formation of the intramolecular hairpin in turn leads to release of the capture oligonucleotide. The ability to select molecular beacons may prove useful for identifying available sites on complex targets, such as mRNAs, while the method for selection can be easily generalized to other, non-nucleic acid target classes.  相似文献   

11.
6-Phenylpyrrolocytidine (PhpC), a structurally conservative and highly fluorescent cytidine analog, was incorporated into oligoribonucleotides. The PhpC-containing RNA formed native-like duplex structures with complementary DNA or RNA. The PhpC-modification was found to act as a sensitive reporter group being non-disruptive to structure and the enzymatic activity of RNase H. A RNA/DNA hybrid possessing a single PhpC insert was an excellent substrate for HIV-1 RT Ribonuclease H and rapidly reported cleavage of the RNA strand with a 14-fold increase in fluorescence intensity. The PhpC-based assay for RNase H was superior to the traditional molecular beacon approach in terms of responsiveness, rapidity and ease (single label versus dual). Furthermore, the PhpC-based assay is amenable to high-throughput microplate assay format and may form the basis for a new screen for inhibitors of HIV-RT RNase H.  相似文献   

12.
We have developed a continuous fluorescence assay based on fluorescence resonance energy transfer (FRET) for the monitoring of RNA helicase activity in vitro. The assay is tested using the hepatitis C virus (HCV) NS3 helicase as a model. We prepared a double-stranded RNA (dsRNA) substrate with a 5′ fluorophore-labeled strand hybridized to a 3′ quencher-labeled strand. When the dsRNA is unwound by helicase, the fluorescence of the fluorophore is emitted following the separation of the strands. Unlike in conventional gel-based assays, this new assay eliminates the complex and time-consuming steps, and can be used to simply measure the real-time kinetics in a single helicase reaction. Our results demonstrate that Alexa Fluor 488 and BHQ1 are an effective fluorophore-quencher pair, and this assay is suitable for the quantitative measurement of the RNA helicase activity of HCV NS3. Moreover, we found that several extracts of marine organisms exhibited different inhibitory effects on the RNA and DNA helicase activities of HCV NS3. We propose that this assay will be useful for monitoring the detailed kinetics of RNA unwinding mechanisms and screening RNA helicase inhibitors at high throughput.  相似文献   

13.
van Schie RC  Marras SA  Conroy JM  Nowak NJ  Catanese JJ  de Jong PJ 《BioTechniques》2000,29(6):1296-300, 1302-4, 1306 passim
Conventional, high-throughput PCR analysis of common elements utilizing numerous primer sets and template DNA requires multiple rounds of PCR to ensure optimal conditions. Laborious gel electrophoresis and staining is then necessary to visualize amplification products. We propose novel multicolor molecular beacons, to establish a high-throughput, PCR-based sequence tagged site (STS) detection system that swiftly and accurately confirms marker content in template containing common repeat elements. A simple, one-tube, real-time PCR assay system was developed to specifically detect regions containing CA and GATA repeats. Ninety-six samples can be confirmed for marker content in a closed-tube format in 3 h, eliminating product confirmation on agarose gels and avoiding crossover contamination. Multiple STSs can be detected simultaneously in the same reaction tube by utilizing molecular beacons labeled with multicolor fluorophores. Template DNA from 260 RPCI-11 bacterial artificial chromosome (BAC) clones was examined for the presence of CA and/or GATA repeats using molecular beacon PCR and compared with conventional PCR results of the same clones. Of the 205 clones containing CA and GATA repeats, we were able to identify 129 clones (CA, n = 99; GATA, n = 30) by using molecular beacons and only 121 clones (CA, n = 92; GATA, n = 29) by conventional PCR amplification. As anticipated, 55 clones that contained sequences other than CA or GATA failed molecular beacon detection. Molecular beacon PCR, employing beacons specific for tandem repeat elements, provides a fast, accurate, and sensitive multiplex detection assay that will expedite verification of marker content in a multitude of template containing these repeats.  相似文献   

14.
The hepatitis C virus (HCV) NS3 protein is a helicase capable of unwinding duplex RNA or DNA. This study uses a newly developed molecular-beacon-based helicase assay (MBHA) to investigate how nucleoside triphosphates (NTPs) fuel HCV helicase-catalyzed DNA unwinding. The MBHA monitors the irreversible helicase-catalyzed displacement of an oligonucleotide-bound molecular beacon so that rates of helicase translocation can be directly measured in real time. The MBHA reveals that HCV helicase unwinds DNA at different rates depending on the nature and concentration of NTPs in solution, such that the fastest reactions are observed in the presence of CTP followed by ATP, UTP, and GTP. 3′-Deoxy-NTPs generally support faster DNA unwinding, with dTTP supporting faster rates than any other canonical (d)NTP. The presence of an intact NS3 protease domain makes HCV helicase somewhat less specific than truncated NS3 bearing only its helicase region (NS3h). Various NTPs bind NS3h with similar affinities, but each NTP supports a different unwinding rate and processivity. Studies with NTP analogs reveal that specificity is determined by the nature of the Watson-Crick base-pairing region of the NTP base and the nature of the functional groups attached to the 2′ and 3′ carbons of the NTP sugar. The divalent metal bridging the NTP to NS3h also influences observed unwinding rates, with Mn2+ supporting about 10 times faster unwinding than Mg2+. Unlike Mg2+, Mn2+ does not support HCV helicase-catalyzed ATP hydrolysis in the absence of stimulating nucleic acids. Results are discussed in relation to models for how ATP might fuel the unwinding reaction.  相似文献   

15.
Molecular beacons are hairpin-shaped, single-stranded oligonucleotides constituting sensitive fluorescent DNA probes widely used to report the presence of specific nucleic acids. In its closed form the stem of the hairpin holds the fluorophore covalently attached to one end, close to the quencher, which is covalently attached to the other end. Here we report that in the closed form the fluorophore and the quencher form a ground state intramolecular heterodimer whose spectral properties can be described by exciton theory. Formation of the heterodimers was found to be poorly sensitive to the stem sequence, the respective positions of the dyes and the nature of the nucleic acid (DNA or RNA). The heterodimer allows strong coupling between the transition dipoles of the two chromophores, leading to dramatic changes in the absorption spectrum that are not compatible with a Förster-type fluorescence resonance energy transfer (FRET) mechanism. The excitonic heterodimer and its associated absorption spectrum are extremely sensitive to the orientation of and distance between the dyes. Accordingly, the application of molecular beacons can be extended to monitoring short range modifications of the stem structure. Moreover, the excitonic interaction was also found to operate for doubly end-labeled duplexes.  相似文献   

16.
Molecular beacons represent a new family of fluorescent probes for nucleic acids, and have found broad applications in recent years due to their unique advantages over traditional probes. Detection of nucleic acids using molecular beacons has been based on hybridization between target molecules and molecular beacons in a 1:1 stoichiometric ratio. The stoichiometric hybridization, however, puts an intrinsic limitation on detection sensitivity, because one target molecule converts only one beacon molecule to its fluorescent form. To increase the detection sensitivity, a conventional strategy has been target amplification through polymerase chain reaction. Instead of target amplification, here we introduce a scheme of signal amplification, nicking enzyme signal amplification, to increase the detection sensitivity of molecular beacons. The mechanism of the signal amplification lies in target-dependent cleavage of molecular beacons by a DNA nicking enzyme, through which one target DNA can open many beacon molecules, giving rise to amplification of fluorescent signal. Our results indicate that one target DNA leads to cleavage of hundreds of beacon molecules, increasing detection sensitivity by nearly three orders of magnitude. We designed two versions of signal amplification. The basic version, though simple, requires that nicking enzyme recognition sequence be present in the target DNA. The extended version allows detection of target of any sequence by incorporating rolling circle amplification. Moreover, the extended version provides one additional level of signal amplification, bringing the detection limit down to tens of femtomolar, nearly five orders of magnitude lower than that of conventional hybridization assay.  相似文献   

17.
Aptamer beacons for the direct detection of proteins.   总被引:9,自引:0,他引:9  
We have designed a new class of molecules, which we term aptamer beacons, for detecting a wide range of ligands. Similar to molecular beacons, aptamer beacons can adopt two or more conformations, one of which allows ligand binding. A fluorescence-quenching pair is used to report changes in conformation induced by ligand binding. An anti-thrombin aptamer was engineered into an aptamer beacon by adding nucleotides to the 5'-end which are complementary to nucleotides at the 3'-end of the aptamer. In the absence of thrombin, the added nucleotides will form a duplex with the 3'-end, forcing the aptamer beacon into a stem-loop structure. In the presence of thrombin, the aptamer beacon forms the ligand-binding structure. This conformational change causes a change in the distance between a fluorophore attached to the 5'-end and a quencher attached to the 3'-end. Aptamer beacon can be a sensitive tool for detecting proteins and other chemical compounds.  相似文献   

18.
The non-structural protein 3 (NS3) of hepatitis C virus (HCV) is a highly promising target for anti-HCV therapy because of its multiple enzymatic activities, such as RNA-stimulated nucleoside triphosphatase, RNA helicase and serine protease. The helicase domain of NS3 as well as domain 2 of the helicase were expressed in a baculovirus system to obtain in high yield active proteins for prospective studies of complexes of the helicase with its inhibitors. A novel direct fluorometric test of helicase activity with a quenched DNA substrate, 3' labeled with a Cy3 dye and 5' labeled with a Black Hole Quencher, was developed and optimal reaction conditions established. This test based on fluorescence resonance energy transfer is simple and fast. It allows for direct measurements of enzyme activity, circumventing laborious and complicated radioactive techniques that are poorly reproducible. The results obtained encourage us to propose this new fluorescent assay as a method enabling high throughput screening of anti-helicase compounds.  相似文献   

19.
Aptamers have been utilized as biosensors because they can be readily adapted to sensor platforms and signal transduction schemes through both rational design and selection. One highly generalizable scheme for the generation of the so‐called aptamer beacons involves denaturing the aptamer with antisense oligonucleotides. For example, rational design methods have been utilized to adapt anti‐thrombin aptamers to function as biosensors by hybridizing an antisense oligonucleotide containing a quencher to the aptamer containing a fluorescent label. In the presence of thrombin, the binding equilibrium is shifted, the antisense oligonucleotide dissociates, and the beacon lights up. By changing the affinity of the antisense oligonucleotide for the aptamer beacon, it has proven possible to change the extent of activation of the beacon. More importantly, modulating interactions between the antisense oligonucleotide and the aptamer strongly influences the kinetics of activation. Comparisons across multiple, designed aptamer beacons indicate that there is a strong inverse correlation between the thermodynamics of hybridization and the speed of activation, a finding that should prove to be generally useful in the design of future biosensors. By pre‐organizing the thrombin‐binding quadruplex within the aptamer the speed of response can be greatly increased. By integrating these various interactions, we were ultimately able to design aptamer beacons that were activated by threefold within 1 min of the addition of thrombin. Biotechnol. Bioeng. 2009;103: 1049–1059. © 2009 Wiley Periodicals, Inc.  相似文献   

20.
Molecular beacons are oligonucleotide probes capable of forming a stem-loop hairpin structure with a reporter dye at one end and a quencher at the other end. Conventional molecular beacons are designed with a target-binding domain flanked by two complementary short arm sequences that are independent of the target sequence. Here we report the design of shared-stem molecular beacons with one arm participating in both stem formation when the beacon is closed and target hybridization when it is open. We performed a systematic study to compare the behavior of conventional and shared-stem molecular beacons by conducting thermodynamic and kinetic analyses. Shared-stem molecular beacons form more stable duplexes with target molecules than conventional molecular beacons; however, conventional molecular beacons may discriminate between targets with a higher specificity. For both conventional and shared-stem molecular beacons, increasing stem length enhanced the ability to differentiate between wild-type and mutant targets over a wider range of temperatures. Interestingly, probe-target hybridization kinetics were similar for both classes of molecular beacons and were influenced primarily by the length and sequence of the stem. These findings should enable better design of molecular beacons for various applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号