首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract: Enzyme Linked Immunoadsorbent Assays are described for Myelin Basic Protein and antibodies to this protein. Under optimal conditions 30 pg of Basic Protein and 100 pg of antibody can be detected. Both assays are simple to establish, require small volumes of sample, and are highly reproducible. All the necessary reagents are stable indefinitely.  相似文献   

2.
A sensitive sandwich enzyme immunoassay for human growth hormone (hGH) using monoclonal antibody is described. A monoclonal anti-hGH IgG-coated polystyrene ball was incubated with hGH and subsequently with affinity-purified rabbit anti-hGH Fab'-horseradish peroxidase conjugate. Peroxidase activity bound to the polystyrene ball was assayed by fluorimetry using 3-(4-hydroxyphenyl) propionic acid as a substrate. The detection limits of hGH in serum and urine were 1.5 ng/l using 20 microliters of serum and 0.2 ng/l using 0.15 ml of urine, respectively. The specificity and assay precision were satisfactory. hGH levels in serum and urine determined by the present sandwich enzyme immunoassay using monoclonal anti-hGH IgG-coated polystyrene balls were well correlated to those determined by the previous sandwich enzyme immunoassay using rabbit anti-hGH IgG-coated polystyrene balls. Levels of hGH in urine collected as first morning voids from healthy subjects aged 19-28 yr were 6.4 +/- 3.2 (SD) ng/g creatinine. However, the present assay gave lower hGH levels than the previous assay. This was at least partly explained by the fact that hGH in urine was less efficiently bound to monoclonal anti-hGH IgG-polystyrene balls than standard hGH, while the binding of hGH in urine and standard hGH to rabbit anti-hGH IgG-coated polystyrene balls was equally efficient. In addition, gel filtration showed that 22K hGH, a major component, in urine was less efficiently bound to monoclonal anti-hGH IgG-coated polystyrene balls than standard 22K hGH. The nature of hGH in serum and urine remains to be investigated.  相似文献   

3.
We have developed a new method for highly selective determination of the ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) concentration using a surface plasmon resonance imaging (SPRI) technique and two different biosensors. UCH-L1 was captured from a solution by immobilized specific rabbit monoclonal antibody or specific LDN-57444 inhibitor due to formation of receptor–UCH-L1 complex on the biosensor surface. The analytically useful dynamic response range of both biosensors is between 0.1 and 2.5 ng/ml. The detection limit is 0.06 ng/ml for the biosensor with antibody and 0.08 ng/ml for the biosensor with inhibitor. Biosensors based on both antibody and inhibitor were found to be suitable for quantitative determination of the UCH-L1 and exhibit good tolerance to the potential interferents. Both biosensors gave comparable results in the range of 0 to 0.20 ng/ml for plasma samples and 0.30 to 0.49 ng/ml for cerebrospinal fluid samples. To validate the new methods, comparative determination of UCH-L1 by the commercial enzyme-linked immunosorbent assay (ELISA) kit was performed. In general, in terms of UCH-L1 concentration, a good correlation between SPRI and ELISA was found. The developed biosensors can be used successfully for the determination of UCH-L1 in body fluids.  相似文献   

4.
A highly sensitive enzyme immunoassay of anti-insulin antibodies in guinea pig serum is described. Guinea pig anti-insulin serum was diluted to various extents with nonspecific guinea pig serum and incubated with insulin. After incubation, free insulin was separated from insulin-anti-insulin antibody complex by treatment with dextran-charcoal. Anti-insulin antibodies in the complex were dissociated from insulin by incubation with 0.23 M HCl and inactivated. The amount of dissociated insulin was measured by sandwich enzyme immunoassay using anti-insulin IgG-coated polystyrene balls and affinity-purified anti-insulin Fab'-horseradish peroxidase conjugate. The detection limit of anti-insulin antibodies in guinea pig serum was 6.7 pg/assay or 150 ng/liter of serum. The present enzyme immunoassay was 10,000-fold more sensitive than the previously described enzyme immunoassay, in which insulin-coated polystyrene balls were incubated with diluted guinea pig anti-insulin serum and subsequently with rabbit (anti-guinea pig IgG) Fab'-horseradish peroxidase conjugate.  相似文献   

5.
6.
Molecular weight markers which are detectable using labeled antispecies antibodies or labeled Protein A have been prepared for use as standards on protein blots. The standards were prepared by the controlled reduction followed by subsequent alkylation of gamma globulin. Separate sets of standards were prepared using gamma globulins derived from human, mouse, rabbit, and sheep species. Standards were also prepared using monoclonal-derived gamma globulins from human myeloma fluid and mouse ascites fluid. Standards produced from monoclonal-derived gamma globulins produced very sharp bands on sodium dodecyl sulfate-polyacrylamide gels and proved to be excellent standards for this technique alone. However, the markers were uniquely suitable for use as standards in protein blotting procedures because their detection was achieved by the procedure used to detect the transferred antigen(s). The detection of immunoglobulin G (IgG)-derived standards on protein blots from all the species listed above was demonstrated using appropriate horseradish peroxidase (HRP)-conjugated antispecies antibodies. The use of other detection systems (biotin-labeled antibody and subsequent detection with HRP-steptavidin, HRP-Protein A) was also validated with human IgG-derived standards. Furthermore, the standards were shown to be suitable for use on both nitrocellulose and cationized nylon-based supports and could be used when adjacent samples were run under reducing conditions. Hence the gamma globulin-derived standards serve as both a control to check the adequacy of transfer and immunodetection systems and as markers which enable the molecular weights of detected antigens to be calculated.  相似文献   

7.
A chemiluminescence immunoassay for the detection of four heart marker proteins: myoglobin, creatine kinase mb [CKmb], troponin I [TnI], and fatty acid-binding protein [FABP], was designed. The immunoassay was based on enzyme-linked immunosorbent assay [ELISA] and antibodies immobilized in glass capillaries pre-treated with 3-aminopropyltriethoxysilane. The protein bound to the antibody was detected by using an anti-protein-horseradish peroxidase [HRP] conjugate. The reaction of the HRP with luminal and hydrogen peroxide-based substrate generated the chemiluminescence and a photodiode detector was used to measure the light intensity. The same assay protocol was used to detect all four proteins. Ultrasound waves were used to improve the silanization of glass and the antibody immobilization process. The optimization of the duration and intensity of the ultrasound was performed for the myoglobin assay. Ultrasound improved the silanization procedure and the capillaries gave an approximately 2.5 times greater ELISA response. Ultrasound also improved the sensitivity by approximately 100% when monoclonal antibody was immobilized on a glass capillary. Calibration curves corresponding to analyte concentrations ranging from 2.4 to 2400 ng/ml in plasma samples were recorded. The detection limits were in the region of 1.2 myoglobin, 0.6 CKmb, 5.6 TnI, and 4 ng/ml FABP in plasma with a coefficient of variation of 3-9.9%.  相似文献   

8.
In this study, a novel immunoassay using 2 types of sensors (QDs and an enzyme) were simultaneously used for detecting multiple structurally different molecules in milk. The method integrates the fluorescence-linked immunosorbent assay (FLISA) using QD605 and QD655 as probes and an enzyme-linked immunosorbent assay (ELISA) using horseradish peroxidase (HRP) labeled secondary antibody. The FLISA was produced by anti-sulfonamide and anti-quinolone broad-specificity monoclonal antibodies (MAbs) for simultaneously detecting 6 sulfonamides and 11 quinolones. Combined with the FLISA, an ELISA was utilized for detecting melamine from the same milk samples. The cross-reactivity of the MAbs was retained while binding the QDs by using avidin and a secondary antibody as bridges. Milk samples were detected using this hybrid immunoassay, with limits of detection (LOD) of the quinolones (0.18 ng mL(-1)), sulfonamides (0.17 ng mL(-1)) and melamine (7.5 ng mL(-1)), respectively. The results demonstrated that the detection limits of the integrated methods were better than required and simplified the sample pretreatment process. The developed immunoassay is suitable for high-throughput screening of low-molecular weight contaminants.  相似文献   

9.
The re-emergence of tuberculosis (TB) as a global public health threat highlights the necessity of rapid, simple and inexpensive point-of-care detection of the disease. Early diagnosis of TB is vital not only for preventing the spread of the disease but also for timely initiation of treatment. The later in turn will reduce the possible emergence of multi-drug resistant strains of Mycobacterium tuberculosis. Lipoarabinomannan (LAM) is an important non-protein antigen of the bacterial cell wall, which is found to be present in different body fluids of infected patients including blood, urine and sputum. We have developed a bispecific monoclonal antibody with predetermined specificities towards the LAM antigen and a reporter molecule horseradish peroxidase (HRPO). The developed antibody was subsequently used to design a simple low cost immunoswab based assay to detect LAM antigen. The limit of detection for spiked synthetic LAM was found to be 5.0 ng/ml (bovine urine), 0.5 ng/ml (rabbit serum) and 0.005 ng/ml (saline) and that for bacterial LAM from M. tuberculosis H37Rv was found to be 0.5 ng/ml (rabbit serum). The assay was evaluated with 21 stored clinical serum samples (14 were positive and 7 were negative in terms of anti-LAM titer). In addition, all 14 positive samples were culture positive. The assay showed 100% specificity and 64% sensitivity (95% confidence interval). In addition to good specificity, the end point could be read visually within two hours of sample collection. The reported assay might be used as a rapid tool for detecting TB in resource constrained laboratory settings.  相似文献   

10.
An enzyme-linked immunosorbent assay (ELISA) for goldfish gonadotropin (GTH) was developed with the intent of devising a simple, reliable and nonradioisotopic assay for the measurement of GTH in goldfish biological samples. In this assay, soluble GTH of the standards or samples competes with carp GTH (cGTH) immobilized on a solid support (96-well microplate) for the fixation on antibodies to the beta-subunit of carp gonadotropin. The immobilized antigen-antibody complexes are then revealed by the peroxidase-antiperoxidase (PAP) technique. After revelation of the peroxidase activity, the absorbance value of each well is measured with a microplate reader. The cGTH concentration used for coating the wells is 2 ng/ml and the final dilution of the specific antibody is 1:80,000. The assay can be performed within 24 h and can be used over a range of 0.125-4 ng/ml. At about 50% binding, the intra- and interassay coefficients of variation are 5% and 9% respectively. The displacement curves generated by goldfish plasma or pituitary perifusion fractions were strictly parallel to the standard cGTH. In addition, the stimulation by salmon gonadotropin-releasing hormone of pituitary fractions perifused in vitro caused an immediate increase in the GTH measured in the collected fractions, strongly reinforcing the assumption that this assay indeed measures GTH.  相似文献   

11.
An improved ELISA method for the detection of Salmonella typhimurium   总被引:3,自引:2,他引:1  
The applicability of enzyme-linked immunosorbent assay (ELISA) for the detection of salmonellas in foodstuffs was investigated. Several factors affecting the sensitivity of the ELISA, such as the type of protein used for plate post-coating, the method of antibody labelling, and accelerators for antigen-antibody and enzyme-substrate reactions, were studied. Labelling of the antibody with horseradish peroxidase and the use of o -phenylenediamine as substrate in the detection system were demonstrated to be most suitable for the enzyme assay.
Based on these findings, an improved ELISA method was developed for the detection of Salmonella typhimurium. The improved technique was able to detect as few as 5×104-105 cell/ml of salmonellas, and about 24 h were required to enrich the bacteria in food samples and to perform the test. With some modifications, the ELISA assay could reach a very high level of sensitivity and provide excellent repro-ducibility.  相似文献   

12.
M Reinke  M Piller  K Brune 《Prostaglandins》1989,37(5):577-586
An inhibition enzyme-linked immunosorbent assay (ELISA) was developed using a monoclonal antibody against thromboxane B2 (TXB2). As a specific antigen, the bovine serum albumin conjugate of TXB2 was adsorbed onto polystyrene microtiter plates. The sensitivity of the monoclonal antibody was compared by means of three different enzyme conjugates, all commercially available. The detection limit with immunoglobulin conjugates of alkaline phosphatase and horseradish peroxidase was 0.04 ng of TXB2 per sample. The use of horseradish peroxidase coupled with an avidin-biotin complex allowed a tenfold increase in sensitivity to 0.0045 ng of TXB2 per sample. The suitability of the assay was checked with TXB2-containing human serum and urine samples, which yielded unchanged standard curves. Recovery experiments had an accuracy of r = 0.960 and r = 0.987. Validity was confirmed by a good correlation between radioimmunoassay and ELISA (r = 0.949). Results of an inhibition experiment with platelet-rich plasma in the presence and absence of ibuprofen demonstrated the practical applicability of this method.  相似文献   

13.
Electrochemical magneto immunosensing of antibiotic residues in milk   总被引:1,自引:0,他引:1  
A novel electrochemical immunosensing strategy for the detection of sulfonamide antibiotics in milk based on magnetic beads is presented. Among the different strategies for immobilizing the class-specific anti-sulfonamide antibody to the magnetic beads--such as those based on the use of Protein A or carboxylate modified magnetic beads - ,the best strategy was found to be the covalent bonding on tosyl-activated magnetic beads. The immunological reaction for the detection of sulfonamide antibiotics performed on the magnetic bead is based on a direct competitive assay using a tracer with HRP peroxidase for the enzymatic labelling. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC), which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate for the enzyme HRP and an electrochemical mediator. The electrochemical approach is also compared with a novel magneto-ELISA with optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked milk samples, and the detection limit was found to be 1.44 microg L(-1) (5.92 nmol L(-1)) for raw full cream milk. This strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological, food and environmental samples.  相似文献   

14.
This is the first report of a quantitative radioimmunoassay for PO. The assay uses antigen-coated plastic microwells, with antibody binding detected by 125I-labeled protein A. Either peripheral myelin proteins or purified PO may be used as the antigen. Optimal extraction of tissue samples for PO immunoassay requires careful attention to the sodium dodecyl sulfate-to-protein ratio. Sodium dodecyl sulfate interference with antibody binding can be minimized by adding an excess of nonionic detergent and carrier protein to the incubation buffer. This method allows the detection of 0.8 ng of PO (20 ng/ml). Results from this assay showed little or no immunoreactivity in extracts of brain, centra myelin, liver, purified myelin basic proteins, cultured, purified secondary Schwann cells, or membrane preparations from these cells. PO was clearly detectable in Schwann cell cultures from 3- to 4-day-old rats at 12-18 h after dissociation (4% of the level in adult sciatic nerve) and in extracts of one-day-old rat sciatic nerve (2% of the level in adult nerve). Myelin basic protein radioimmunoassays showed that the ratio of PO to myelin basic protein is essentially constant in extracts of sciatic nerve from ne-day-old, four-day-old, and young adult rats. Another result was that PO levels are reduced in the trembler mouse sciatic nerve.  相似文献   

15.
A competitive, sensitive, and rapid enzyme-linked immunoadsorbent assay (ELISA) was developed for the determination of estriol in saliva and in plasma. Horseradish peroxidase (HRP) was used as the label enzyme; separation between free and bound steroid was carried out by insolubilized antibody prepared by adsorbing purified IgG of rabbit anti-6-oxoestriol-6-(0-carboxymethyl)oxime-BSA on polystyrene balls. The enzyme activity was measured by a colorimetric reaction using o-phenylenediamine dihydrochloride and hydrogen peroxide as substrate. The sensitivity of the assay was 12 pg/tube.In order to compare ELISA to RIA estriol estimations in different biological fluids, we selected six women during normal pregnancy, from the 30th to the 40th week of gestation. Salivary estriol was assayed by direct and extraction methods, while the corresponding plasma samples of the same subjects were analyzed only for unconjugated estriol by an extraction method.A good agreement was found between the results obtained by RIA and ELISA: r=0.897, p <0.001 between direct RIA and direct ELISA in saliva; r=0.909, p < 0.001 between extraction RIA and direct ELISA in saliva; and r=0.916, p < 0.001 between extraction RIA and extraction ELISA in plasma. A good correlation (r=0.793, p<0.001) was present between plasma samples by RIA and saliva samples by ELISA (direct method).These results indicate that: 1. ELISA is a reliable method for the determination of estriol in plasma and saliva. 2. Saliva samples can be used for the assay of estriol and therefore for the assessment of fetal conditions during pregnancy.  相似文献   

16.
The applicability of enzyme-linked immunosorbent assay (ELISA) for the detection of salmonellas in foodstuffs was investigated. Several factors affecting the sensitivity of the ELISA, such as the type of protein used for plate post-coating, the method of antibody labelling, and accelerators for antigen-antibody and enzyme-substrate reactions, were studied. Labelling of the antibody with horseradish peroxidase and the use of o-phenylenediamine as substrate in the detection system were demonstrated to be most suitable for the enzyme assay. Based on these findings, an improved ELISA method was developed for the detection of Salmonella typhimurium. The improved technique was able to detect as few as 5 x 10(4)-10(5) cell/ml of salmonellas, and about 24 h were required to enrich the bacteria in food samples and to perform the test. With some modifications, the ELISA assay could reach a very high level of sensitivity and provide excellent reproducibility.  相似文献   

17.
A solid phase immunoassay for aldosterone using enhanced chemiluminescent detection has been developed. Monoclonal antibodies against aldosterone were used for the immune reaction and compared with polyclonal antibodies. Uniform Protein A coated polystyrene tubes were used as solid phase for the monoclonal antibody and second (anti-rabbit) antibody coated tubes for the polyclonal antibody. Horseradish peroxidase was covalently linked to aldosterone as enzyme label. Optimum conditions were established for the generation and measurement of the luminescent reactions using luminol, p-iodophenol as enhancer and hydrogen peroxide. The advantages of this assay are the high sensitivity with a detection limit of 100fg/tube, the prolonged luminescence signal with a simplification of the measurement (simpler detectors, external start pipetting) and the short measure time with the possibility of repeated measurement. The coefficients of variation were 4.2%–7.3% in the concentration range 140–1180 pmol/l. The assay showed a significant correlation (r = 0.91) with the ELISA. The aldosterone concentrations in plasma and saliva of patients with Conn's syndrome were significantly increased, and in patients with Addison's disease were found near the detection limit.  相似文献   

18.
An assay using scintillation proximity bead technology has been developed suitable for the quantitation of endothelin (ET) receptor antagonists in preclinical and clinical samples of plasma. The assay measures the competitive inhibition of radiolabelled ET-1 binding to ET(A) receptor membranes bound to wheat germ agglutinin (WGA)-coated scintillation proximity assay (SPA) beads in the presence of plasma containing A-127722, a potent orally active, ET(A) selective ET antagonist. The assay requires as little as 50 microl plasma and no extraction procedure is needed. The SPA methodology eliminates the need for the separation of bound from free ligand. Using this method, A-127722 could be directly quantified in rat plasma with a detection limit of 1 ng/ml.  相似文献   

19.
Adducts of benzo[a]pyrene-diolepoxide (BPDE) with blood nucleophiles have been used as biomarkers of exposure to polycyclic aromatic hydrocarbons (PAHs). The most popular such assay is a competitive enzyme-linked immunosorbent assay (ELISA) that employs monoclonal antibody 8E11 to detect benzo[a]pyrene tetrols following hydrolysis of BPDE adducts from lymphocyte DNA or human serum albumin (HSA). Here we used 8E11 as the capture antibody in a sandwich ELISA to detect BPDE-HSA adducts directly in 1-mg samples of HSA or 20 μl of serum/plasma. The assay employs an anti-HSA antibody for detection, and this is amplified by an avidin/biotinylated horseradish peroxidase complex. The sandwich ELISA has advantages of specificity and simplicity and is approximately 10 times more sensitive than the competitive ELISA. To validate the assay, HSA samples were assayed from three populations with known high PAH exposures (coke oven workers), medium PAH exposures (steel factory control workers), and low PAH exposures (volunteer subjects) (n = 30). The respective geometric mean levels of BPDE-HSA adducts—67.8, 14.7, and 1.93 ng/mg HSA (1010, 220, and 28.9 fmol BPDE equiv/mg HSA)—were significantly different (P < 0.05). The sandwich ELISA will be useful for screening PAH exposures in large epidemiologic studies and can be extended to other adducts for which capture antibodies are available.  相似文献   

20.
A selective and sensitive method for the determination of lipoic acid in human plasma samples has been developed. After enzymatic hydrolysis of the sample, the liberated lipoic acid was extracted by a solid-phase cartridge and measured by HPLC using electrochemical detection. The detection limit was 1 ng/ml lipoic acid in plasma. The calibration curve was non-linear in the range 0.01–50 μg/ml but could be described by a power function. The average extraction recoveries were 82.5 and 85.1% at the 25 and 2500 ng/ml levels, respectively. Coefficients of variation for both within-day and day-to-day analysis were between 2.1 and 9.4%. The assay method is sensitive, reproducible and suitable for disposition studies of lipoic acid in humans.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号