首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeThis study aimed to investigate the potential of magnetic particle imaging (MPI) to quantify artificial stenoses in vessel phantoms in near real-time.MethodsCustom-made stenosis phantoms with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%; length 40 mm, inner diameter 8 mm, Polyoxymethylene) were filled with diluted Ferucarbotran (superparamagnetic iron-oxide nanoparticle (SPION) tracer agent, 500 mmol (Fe)/l). A traveling wave MPI scanner (spatial resolution ~ 2 mm, gradient strength ~ 1.5 T/m, field of view: 65 mm length and 29 mm diameter, frequencies f1 = 1050 Hz and f2 = 12150 Hz) was used to acquire images of the phantoms (200 ms total acquisition time per image, 10 averages). Standardized grey scaling was used for comparability. All measured stenoses (n = 80) were graded manually using a dedicated software tool.ResultsMPI allowed for accurate visualization of stenoses at a frame rate of 5 frames per second. Less severe stenoses were detected more precisely than higher-grade stenoses and came with smaller standard deviations. In particular, the 0%, 25%, 50%, 75%, and 100% stenosis phantom were measured as 3.7 ± 2.7% (mean ± standard deviation), 18.6 ± 1.8%, 52.8 ± 3.7%, 77.8 ± 14.8% and 100 ± 0%. Geometrical distortions occurred around the center of the high-grade stenosis and led to higher standard deviations compared to lower grade stenoses. In the frame of this study the MPI signal depended linearly on the SPION concentration down to 0.05 mmol (Fe)/l.ConclusionNear real-time MPI accurately visualized and quantified different stenosis grades in vascular phantoms.  相似文献   

2.
PurposeFeasability of a no-reference image quality metric was assessed on patient-like images using a patient-specific phantom simulating a frame of a coronary angiogram.MethodsOne background and one contrast-filled frame of a coronary angiogram, acquired using a clinical imaging protocol, were selected from a Philips Integris Allura FD (Philips Healthcare, Best, The Netherlands). The background frame’s pixels were extruded to a thickness proportional to their grey value. One phantom was 3D printed using composite 80% bronze filament (max. thickness of 5.1 mm), the other was a custom PMMA cast (max thickness of 8.5 cm). A vessel mold was created from the contrast-filled frame and injected with a solution of 320 mg I/ml contrast fluid (75%), water and gelatin. Still X-ray frames of the vessel mold + background phantom + 16 cm PMMA were acquired at manually selected different exposure settings using a Philips Azurion (Philips Healthcare, Best, The Netherlands) in User Quality Control Mode and were exported as RAW images. The signal-difference-to-noise-ratio-squared (SDNR2) and a spatial-domain-equivalent of the noise equivalent quanta (NEQSDE) were calculated. The Spearman’s correlation of the latter parameters with a no-reference perceptual image quality metric (NIQE) was investigated.ResultsThe bronze phantom showed better resemblance to the original patient frame selected from a coronary angiogram of an actual patient, with better contrast and less blur than the PMMA phantom. Both phantoms were imaged using a comparable imaging protocol to the one used to acquire the original frame. The bronze phantom was hence used together with the vessel mold for image quality measurements on the 165 still phantom frames. A strong correlation was noted between NEQSDE and NIQE (SROCC = –0.99, p < 0.0005) and between SDNR2 and NIQE (SROCC = –0.97, p < 0.0005).ConclusionUsing a cost-effective and easy to realize patient-specific phantom we were able to generate patient-like X-ray frames. NIQE as a no-reference image quality model has the potential to predict physical image quality from patient images.  相似文献   

3.
PurposeTo measure the combined errors due to geometric inaccuracy and image co-registration on secondary images (dynamic CT angiography (dCTA), 3D DynaCT angiography (DynaCTA), and magnetic resonance images (MRI)) that are routinely used to aid in target delineation and planning for stereotactic radiosurgery (SRS).MethodsThree phantoms (one commercial and two in-house built) and two different analysis approaches (commercial and MATLAB based) were used to quantify the magnitude of geometric image distortion and co-registration errors for different imaging modalities within CyberKnife’s MultiPlan treatment planning software. For each phantom, the combined errors were reported as a mean target registration error (TRE). The mean TRE’s for different intramodality imaging parameters (e.g., mAs, kVp, and phantom set-ups) and for dCTA, DynaCTA, and MRI systems were measured.ResultsOnly X-ray based imaging can be performed with the commercial phantom, and the mean TRE ± standard deviation values were large compared to the in-house analysis using MATLAB. With the 3D printed phantom, even drastic changes in treatment planning CT imaging protocols did not greatly influence the mean TRE (<0.5 mm for a 1 mm slice thickness CT). For all imaging modalities, the largest mean TRE was found on DynaCT, followed by T2-weighted MR images (albeit all <1 mm).ConclusionsThe user may overestimate the mean TRE if the commercial phantom and MultiPlan were used solely. The 3D printed phantom design is a sensitive and suitable quality assurance tool for measuring 3D geometric inaccuracy and co-registration errors across all imaging modalities.  相似文献   

4.
5.
PurposeTo investigate whether a newly-developed single-energy metal artifact reduction (SEMAR) algorithm applied to images acquired on a 320-MDCT volume scanner reduces image artifacts from dental metal.MethodsWe inserted the lower right teeth covered with a dental metal alloy and crown in a skull phantom and performed single-volume scanning on a second-generation 320-MDCT scanner. A 12-mm diameter spherical lesion was placed either close to or far from the dental metal. The tube voltage and current were 120 kVp and 80 or 155 mA, respectively. Images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR), with or without SEMAR. We calculated the signal-to-artifact ratios (SAR) to quantify the visibility of the lesion. Two radiologists inspected 96 images (48 with lesion and 48 without) for the presence or absence of the lesion using a 5-point ordinal scale (1 = definitely absent to 5 = definitely present).ResultsOn images reconstructed with FPB and IR with SEMAR, streak artifacts from the dental metal were reduced substantially compared to images without SEMAR. At 155 mA with the lesion near the dental metal, the SARs were better on FBP and IR images (FBP: 1.7 and 0.5 with and without SEMAR, respectively; IR: 1.6 and 0.9 with and without SEMAR, respectively). The observer visual scores improved with SEMAR (FBP: 4.2 and 3.2 with and without SEMAR, respectively; IR: 4.2 and 3.0).ConclusionThe SEMAR algorithm reduces dental metal artifacts and improves lesion detectability and image quality in patients with oral cavity lesions.  相似文献   

6.
PurposeMRI for radiotherapy planning requires spatial referencing using immobilization devices and markers. Clinical images of a difficult-to-interpret artifact are presented, resembling a metastasis, which occurs when combining CAIPIRINHA k-space-based parallel imaging (PI), 3D distortion correction, and external markers.MethodsA 3D variable flip angle Turbo Spin Echo sequence was used on a 1.5 T and 3 T MRI using flexible and head and neck coils. Two types of markers were tested: Liquimark LM1 and Spee-D-Mark. A silicone oil phantom was used that represents low signal intensity, such as gray matter. 3D Fourier transforms were also used to show the issue’s origin.ResultsThe markers can appear in an unexpected region of a patient, not in the same original or reconstructed slice nor in a rectilinear direction in a slice, especially when using CAIPIRINHA acceleration with 3D distortion correction. The probability of occurrence was respectively 13% and 80% for distances of <=2 mm and >2 mm between marker and patient, for example when using thermoplastic masks. Clinical cases are shown where this semi-randomly occurring artifact appears post contrast only, and thus can be interpreted as metastases. The artifact did not appear when using compressed sensing acceleration.ConclusionMarkers used for radiotherapy MRI application can introduce additional artifacts that can be interpreted as metastases. However, other high signal intensity structures on the surface of a patient, such as the ear, can lead to an equivalent error.  相似文献   

7.
PurposeTo investigate the potential of dual energy CT (DECT) to suppress metal artifacts and accurately depict episcleral brachytherapy Ru-106 plaques after surgical placement.MethodsAn anthropomorphic phantom simulating the adult head after surgical placement of a Ru-106 plaque was employed. Nine DECT acquisition protocols for orbital imaging were applied. Monochromatic 140 keV images were generated using iterative reconstruction and an available metal artifact reduction algorithm. Generated image datasets were graded by four observers regarding the ability to accurate demarcate the Ru-106 plaque. Objective image quality and visual grading analysis (VGA) was performed to compare different acquisition protocols. The DECT imaging protocol which allowed accurate plaque demarcation at minimum exposure was identified. The eye-lens dose from orbital DECT, with and without the use of radioprotective bismuth eye-shields, was determined using Monte Carlo methods.ResultsAll DECT acquisition protocols were judged to allow clear demarcation of the plaque borders despite some moderate streaking/shading artifacts. The differences between mean observers’ VGA scores for the 9 DECT imaging protocols were not statistically significant (p > 0.05). The eye-lens dose from the proposed low-exposure DECT protocol was found to be 20.1 and 22.8 mGy for the treated and the healthy eye, respectively. Bismuth shielding was found to accomplish >40% reduction in eye-lens dose without inducing shielding-related artifacts that obscure plaque delineation.ConclusionsDECT imaging of orbits after Ru-106 plaque positioning for ocular brachytherapy was found to allow artifact-free delineation of plaque margins at relatively low patient exposure, providing the potential for post-surgery plaque position verification.  相似文献   

8.
PurposeTo determine the variation between Catphan image quality CT phantoms, specifically for use in a future multi-centre image quality audit.Method14 Catphan phantoms (models 503, 504 and 604) were scanned on a Canon Aquilion Prime CT scanner using a single scan protocol. Measurements were made of noise in the uniformity section, visibility of low contrast targets and contrast, x-ray attenuation and CT number for 5 materials in the sensitometry section. Scans were also acquired using one phantom and varying reconstruction field of view, image slice thickness, effective tube-current-time product and iterative reconstruction settings to determine how the degree of inter-phantom variability compared with the magnitude of changes from scan parameter alteration.ResultsAcross all phantoms the mean CT value in the uniformity section was 7.0 (SD 0.9) range: 4.9–8.1 HU. For the different materials the CT numbers were air: −1004 ± 5, Polymethylpentene: −190 ± 2, Polystyrene: −42 ± 2, Delrin: 321 ± 5 and Teflon: 898 ± 8 HU. Consistency of low contrast targets through visual scoring was good. Measured contrast was lower (p < 0.001) with more variability for 504 versus 604 models. All phantoms produced identical tube current settings with x-ray tube current modulation, indicating no x-ray attenuation differences. The degree of change in image quality metrics between phantoms was small compared with results when scan parameters were varied.ConclusionCatphan phantoms model 604 showed minimal differences and will be used for multi-centre inter-comparison work, with the consistency between phantoms appropriate for measuring possible variations in image quality.  相似文献   

9.
PurposeTo quantitatively assess CT image quality and fracture visibility using virtual monochromatic imaging and iterative metal artifact reduction (iMAR) in a femoral bone fracture phantom with different fixation implants.MethodsA custom made phantom was scanned at 120-kVp and 140-kVp single-energy and 100/150-kVp dual-energy. Three stainless steel and two titanium implants with different thicknesses were placed on the phantom containing simulated one and two mm fractures. Single-energy CT images were reconstructed with and without iMAR, while DECT images were reconstructed at monochromatic energies between 70 and 190 keV. Non-metal scans were used as a reference. A Fourier power spectrum method and fracture model were used to analyze several anatomical areas.ResultsCT-value deviations of titanium implants were much lower compared to stainless steel implants. These deviations decreased for both DECT and iMAR. Fracture visibility, measured with the fracture model, improved the most when DECT was used while artifact reduction benefitted more from iMAR. The optimal monochromatic energy for metal artifact reduction, based on CT-value deviation, varied for each metal between 130 and 150 keV. The fracture model provided a signal-to-noise ratio for the near metal fracture visibility, providing the optimal keV.ConclusioniMAR and high keV monochromatic images extracted from DECT both reduce metal artifacts caused by different metal fixation implants. Quantitative femoral phantom results show that DECT is superior to iMAR regarding fracture visualization adjacent to metal fixation implants. The introduction of new artifacts when using iMAR impedes its value in near metal fixation implant imaging.  相似文献   

10.
PurposeTo develop and validate a variable angle stereo image based position correction methodology in an X-ray based in-house online position monitoring system.Materials and methodsA stereo imaging module that enables 3D position determination and couch correction of the patient based on images acquired at any arbitrary angle and arbitrary angular separation was developed and incorporated to the in-house SeedTracker real-time position monitoring system. The accuracy of the developed system was studied by imaging an anthropomorphic phantom implanted with radiopaque markers set to known offset positions from its reference position in an Elekta linear accelerator (LA) and associated XVI imaging system. The accuracy of the system was further validated using CBCT data set from 10 prostate SBRT patients. The time gains achieved with the stereo image based position correction was compared with the manual matching of seed positions in Digitally Reconstructed Radiographs (DRRs) and kV images in the Mosaiq record and verify system.ResultsBased on phantom and patient CBCT dataset study stereo imaging module implemented in the SeedTracker shown to have an accuracy of 0.1(σ = 0.5) mm in detecting the 3D position offset. The time comparison study showed that stereo image based methodology implemented in SeedTracker was a minimum of 80(4) s faster than the manual method implemented in Mosaiq R&V system with a maximum time saving of 146(6) s.ConclusionThe variable angle stereo image based position correction method was shown to be accurate and faster than the standard manual DRR–kV image based correction approach, leading to more efficient treatment.  相似文献   

11.
In many X-ray clinics, the traditional photographic film has been replaced by an imaging plate (IP). The IP is re-usable and the purpose of this study was to test if image deterioration occurred after successive uses of the IP. The emphasis is placed on the efficiency of image formation and on image uniformity.In a cross-sectional study, 21 clinically used IPs were exposed with a standardized phantom imaging protocol. These IPs were in clinical use between one month and two years and the IPs were exposed between 191 and 3787 times. After digitizing, the mean pixel value (MPV) in a predefined image area was determined. The relation between MPV and IP uses was assessed.In a second experiment, image uniformity of 30 other clinically used IPs was visually inspected for artifacts on a diagnostic monitor. These IPs were in clinical use between one week and two years and exposed between 76 and 5373 times.The first experiment showed that no significant deterioration of the MPV with increasing usage count of the IP was present (p = 0.15). The second experiment showed the appearance of clinically relevant artifacts on the IP before 3000 uses.It was concluded that the efficiency of the image formation process does not significantly deteriorate after successive use of IPs and is therefore not expected to limit their life span. Mechanical handling in the digitizer of the used system seems to set a limit to IP durability. Uniformity should therefore be checked regularly in clinical quality control.  相似文献   

12.
PurposeTo evaluate the respiratory motion influence on the tridimensional (3D) dose delivery to breast-shaped phantoms using conformal radiotherapy (3D-RT), Field-in Field (FiF), and IMRT planning techniques.MethodsThis study used breast-shaped phantoms filled with MAGIC-f gel dosimeter to simulate the breast, and an oscillation platform to simulate the respiratory motion. The platform allowed motion in the anterior-posterior direction with oscillation amplitudes of 0.34 cm, 0.88 cm, and 1.22 cm. CT images of the static phantom were used for the 3D-RT, FiF, and IMRT treatment planning. Five phantoms were prepared and irradiated for each planning technique evaluated. Phantom 1 was irradiated static, phantoms 2–4 were irradiated moving with the three different motion amplitudes, and phantom 5 was used as a reference. The 3D dose distributions were obtained by relaxometry of magnetic resonance imaging, and the respiratory motion influence in the doses distribution was accessed by gamma evaluations (3%/3mm/15% threshold) comparing the measurements of the phantoms irradiated under movement with the static ones.ResultsThe mean gamma approvals for three oscillatory amplitudes were 96.44%, 93.23%, and 91.65%; 98.42%, 95.66%, and 94.31%; and 94.49%, 93.51%, and 86.62% respectively for 3D-RT, FiF and IMRT treatments. A gamma results profile per slice along the phantom showed that for FiF and IMRT irradiations, most of the failures occurred in the central region of the phantom.ConclusionsBy increasing the respiratory motion movement, the dose distribution variations for the three planning techniques were more pronounced, being the FiF technique variations the smallest one.  相似文献   

13.
PurposeKilovoltage flat-panel imaging systems are used for cone-beam Computed Tomography (CBCT) and digital Tomosynthesis (DTS). Hereby, the presence of scatter and relatively large dose from imaging are challenging factors. In this study a phenomenological beam model was developed to characterize imager response to imaging beams with a bow-tie filter (Varian OBI system).Materials and methodThe kilovoltage beam model was based on dose ratio formalism and thus was using standard concepts of megavoltage dose calculation such as scatter factors, tissue maximum ratio and off-axis ratio. Primary and scatter (head and phantom scatter) were modeled with three Gaussian kernels. Parameters were based on measured transmission images for slabs of solid water of different total thickness and various jaw settings.ResultsThe beam model was used to evaluate contributions from primary, secondary and tertiary contributions for different geometrical objects such as cylinders and step-like phantoms. Theoretical predictions of radiographs using the model for known objects are consistent with the measurements.ConclusionSecondary and tertiary contributions were interpreted as scatter and can be subtracted from CBCT projections based on the analytical model. Therefore our model can provide a basis for improvement of image quality (less artifacts due to scatter, better contrast and resolution) in CBCT reconstruction.  相似文献   

14.
PurposeThis study aimed to determine a low-dose protocol for digital chest tomosynthesis (DTS).MethodsFive simulated nodules with a CT number of approximately 100 HU with size diameter of 3, 5, 8, 10, and 12 mm were inserted into an anthropomorphic chest phantom (N1 Lungman model), and then scanned by DTS system (Definium 8000) with varying tube voltage, copper filter thickness, and dose ratio. Three radiophotoluminescent (RPL) glass dosimeters, type GD-352 M with a dimension of 1.5 × 12 mm, were used to measure the entrance surface air kerma (ESAK) in each protocol. The effective dose (ED) was calculated using the recorded total dose-area-product (DAP). The signal-to-noise ratio (SNR) was determined for qualitative image quality evaluation. The image criteria and nodule detection capability were scored by two experienced radiologists. The selected low-dose protocol was further applied in a clinical study with 30 pulmonary nodule follow-up patients.ResultsThe average ESAK obtained from the standard default protocol was 1.68 ± 0.15 mGy, while an ESAK of 0.47 ± 0.02 mGy was found for a low-dose protocol. The EDs for the default and low-dose protocols were 313.98 ± 0.72 µSv and 100.55 ± 0.28 µSv, respectively. There were small non-significant differences in the image criteria and nodule detection scoring between the low-dose and default protocols interpreted by two radiologists. The effective dose of 98.87 ± 0.08 µSv was obtained in clinical study after applying the low-dose protocol.ConclusionsThe low-dose protocol obtained in this study can substantially reduce radiation dose while preserving an acceptable image quality compared to the standard protocol.  相似文献   

15.
Beam hardening filters have long been employed in X-ray Computed Tomography (CT) to preferentially absorb soft and low-energy X-rays having no or little contribution to image formation, thus allowing the reduction of patient dose and beam hardening artefacts. In this work, we studied the influence of additional copper (Cu) and aluminium (Al) flat filters on patient dose and image quality and seek an optimum filter thickness for the GE LightSpeed VCT 64-slice CT scanner using experimental phantom measurements. Different thicknesses of Cu and Al filters (0.5–1.6 mm Cu, 0.5–4 mm Al) were installed on the scanner’s collimator. A planar phantom consisting of 13 slabs of Cu having different thicknesses was designed and scanned to assess the impact of beam filtration on contrast in the intensity domain (CT detector’s output). To assess image contrast and image noise, a cylindrical phantom consisting of a polyethylene cylinder having 16 holes filled with different concentrations of K2HPO4 solution mimicking different tissue types was used. The GE performance and the standard head CT dose index (CTDI) phantoms were also used to assess image resolution characterized by the modulation transfer function (MTF) and patient dose defined by the weighted CTDI. A 100 mm pencil ionization chamber was used for CTDI measurement. Finally, an optimum filter thickness was determined from an objective figure of merit (FOM) metric. The results show that the contrast is somewhat compromised with filter thickness in both the planar and cylindrical phantoms. The contrast of the K2HPO4 solutions in the cylindrical phantom was degraded by up to 10% for a 0.68 mm Cu filter and 6% for a 4.14 mm Al filter. It was shown that additional filters increase image noise which impaired the detectability of low density K2HPO4 solutions. It was found that with a 0.48 mm Cu filter the 50% MTF value is shifted by about 0.77 lp/cm compared to the case where the filter is not used. An added Cu filter with approximately 0.5 mm thickness accounts for 50% reduction in radiation-absorbed dose as measured by the weighted CTDI. The FOM results indicate that with an additional filter of 0.5 mm Cu or minimum 4 mm Al, a good compromise between image quality and patient dose is achieved for CT images acquired at tube voltages of 120 and 140 kVp. The results seem to indicate that an optimum filter for high kVp acquisitions, routinely used in cardiovascular imaging, should be 0.5 mm copper or 4 mm aluminium minimum.  相似文献   

16.
PurposeTo determine the suitable kVp pair for optimal image quality of the virtual monochromatic images (VMIs) and iodine quantification accuracy at low concentration, using a third generation dual-source CT (DSCT).Materials and methodsMulti-energy CT phantoms with and without body rings were scanned with a DSCT using four kVp pairs (tube “A”/“B” voltage): 100/Sn150, 90/Sn150, 80/Sn150 and 70/Sn150 kVp. The reference mAs was adjusted to obtain a CTDIvol close to 11 mGy. HU values accuracy (RMSDHU), noise (SD) and contrast-to-noise ratio (CNR) of iodine inserts of 0.5, 1, 2 and 5 mg/mL concentrations were assessed on VMIs at 40/50/60/70 keV. Iodine quantification accuracy was assessed using the RMSDiodine and iodine bias (IBiodine).ResultsThe RMSDHU decreased when the tube “A” voltage increased. The mean noise value increased significantly with tube “A” voltage (p < 0.001) but decreased between 80/Sn150 and 90/Sn150 kVp for the small phantom (1.1 ± 0.1%; p = 0.047). The CNR significantly decreased with tube “A” voltage (p < 0.001), except between 80/Sn150 and 90/Sn150 kVp for all inserts and between 90/Sn150 kVp and 100/Sn150 kVp for the 1.0 and 0.5 mg/mL inserts in the large phantom. In the small phantom, no significant difference was found between 80/Sn150 kVp and 90/Sn150 kVp for all inserts and between 80/Sn150, 90/Sn150 and 100/Sn150 kVp for the 1 and 0.5 mg/mL inserts. The RMSDiodine and IBiodine decreased as the tube “A” voltage of the kVp pair increased.ConclusionThe kVp pair of 70/Sn150 led to better image quality in VMIs and sufficient iodine accuracy.  相似文献   

17.
PurposeTo evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR).MethodsThree anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom.ResultsThe use of AEC produced a significant dose reduction (p < 0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p < 0.01) and reduced SNR and CNR (p < 0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency.ConclusionsIn chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices.  相似文献   

18.

Introduction

Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen.

Materials and Methods

In vitro, we scanned Enterprise stent phantom and a stent–cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20.

Results

In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P < .05) and showed the highest mean grading score (2.94 ± 0.94; P < .05) and contrast/noise ratio of in-stent lumen (160.03 ±37.79; P < .05) among all the modes.

Conclusion

Iodine (water) images can help reduce stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.  相似文献   

19.
ObjectiveTo evaluate the effect of cone-beam computed tomography (CBCT) image acquisition protocols on image quality, lesion detection, delineation, and patient dose.Methods100-patients and a CTDI phantom combined with an electron density phantom were examined using four different CBCT-image acquisition protocols during image-guided transarterial chemoembolization (TACE). Protocol-1 (time: 6 s, tube rotation: 360°), protocol-2 (5 s, 300°), protocol-3 (4 s, 240°) and protocol-4 (3 s, 180°) were used. The protocols were first investigated using a phantom. The protocols that were found to be clinically appropriate in terms of image quality and radiation dose were then assessed on patients. A higher radiation dose and/or a poor image quality were inappropriate for the patient imaging. Patient dose (patient-entrance dose and dose-area product), image quality (Hounsfield Unit, noise, signal-to-noise ratio and contrast-to-noise ratio), and lesion delineation (tumor-liver contrast) were assessed and compared using appropriate statistical tests. Lesion detectability, sensitivity, and predictive values were estimated for CBCT-image data using pre-treatment patient magnetic resonance imaging.ResultsThe estimated patient dose showed no statistical significance (p > 0.05) between protocols-2 and -3; the assessed image quality between these protocols manifested insignificant difference (p > 0.05). Two other phantom protocols were not considered for patient imaging due to significantly higher dose (protocols-1) and poor image quality (protocol-4). Lesion delineation and detection were insignificant (p > 0.05) between protocols-2 and -3. Lesion sensitivities generated were 81–89% (protocol-2) and 81–85% (protocol-3) for different lesion types.ConclusionData acquisition using protocols-2 and -3 provided good image quality, lesion detection and delineation with acceptable patient dose during CBCT-imaging mainly due to similar frame numbers acquired.  相似文献   

20.
PurposeTo develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the Small Animal Radiation Research Platform (SARRP).Methods and materialsA QA phantom was developed for carrying out daily, monthly and annual QA tasks including: imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of 15 (60 × 60 × 5 mm3) kV-energy tissue equivalent solid water slabs. The phantom can incorporate optically stimulated luminescence dosimeters (OSLD), Mosfet or film. One slab, with inserts and another slab with hole patterns are particularly designed for image QA.ResultsOutput constancy measurement results showed daily variations within 3%. Using the Mosfet in phantom as target, results showed that the difference between TPS calculations and measurements was within 5%. Annual QA results for the Percentage depth dose (PDD) curves, lateral beam profiles, beam flatness and beam profile symmetry were found consistent with results obtained at commissioning. PDD curves obtained using film and OSLDs showed good agreement. Image QA was performed monthly, with image-quality parameters assessed in terms of CBCT image geometric accuracy, CT number accuracy, image spatial resolution, noise and image uniformity.ConclusionsThe results show that the developed QA phantom can be employed as a tool for comprehensive performance evaluation of the SARRP. The study provides a useful reference for development of a comprehensive quality assurance program for the SARRP and other similar small animal irradiators, with proposed tolerances and frequency of required tests.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号