 共查询到20条相似文献,搜索用时 15 毫秒
1.
    
PurposeTo determine the surface dose of a water phantom using a semiconductor detector for diagnostic kilovoltage x-ray beams.MethodsAn AGMS-DM+ semiconductor detector was calibrated in terms of air kerma measured with an ionization chamber. Air kerma was measured for 20 x-ray beams with tube voltages of 50–140 kVp and a half-value layer (HVL) of 2.2–9.7 mm Al for given quality index (QI) values of 0.4, 0.5, and 0.6, and converted to the surface dose. Finally, the air kerma and HVL measured by the AGMS-DM+ detector were expressed as a ratio of the surface dose for 10 × 10 and 20 × 20 cm2 fields. The ratio of both was represented as a function of HVL for the given QI values and verified by comparing it with that calculated using the Monte Carlo method.ResultsThe air kerma calibration factor, CF, for the AGMS-DM+ detector ranged from 0.986 to 1.016 (0.9% in k = 1). The CF values were almost independent of the x-ray fluence spectra for the given QI values. The ratio of the surface dose to the air kerma determined by the PTW 30,013 chamber and the AGMS-DM+ detector was less than 1.8% for the values calculated using the Monte Carlo method, and showed a good correlation with the HVL for the given QI values.ConclusionIt is possible to determine the surface dose of a water phantom from the air kerma and HVL measured by a semiconductor detector for given QI values.  相似文献   

2.
    
PurposeInstitutional (local) Diagnostic Reference Levels for Cerebral Angiography (CA), Percutaneous Transhepatic Cholangiography (PTC), Transarterial Chemoembolization (TACE) and Percutaneous Transhepatic Biliary Drainage (PTBD) are reported in this study.Materials and methodsData for air kerma-area product (PKA), air kerma at the patient entrance reference point (Ka,r), fluoroscopy time (FT) and number of images (NI) as well as estimates of Peak Skin Dose (PSD) were collected for 142 patients. Therapeutic procedure complexity was also evaluated, in an attempt to incorporate it into the DRL analysis.ResultsLocal PKA DRL values were 70, 34, 189 and 54 Gy.cm2 for CA, PTC, TACE and PTBD respectively. The corresponding DRL values for Ka,r were 494, 194, 1186 and 400 mGy, for FT they were 9.2, 14.2, 27.5 and 22.9 min, for the NI they were 844, 32, 602 and 13 and for PSD they were 254, 256, 1598 and 540 mGy respectively. PKA for medium complexity PTBD procedures was 2.5 times higher than for simple procedures. For TACE, the corresponding ratio was 1.6. PSD was estimated to be roughly 50% of recorded Ka,r for procedures in the head/neck region and 10% higher than recorded Ka,r for procedures in the body region. In only 5 cases the 2 Gy dose alarm threshold for skin deterministic effects was exceeded.ConclusionProcedure complexity can differentiate DRLs in Interventional Radiology procedures. PSD could be deduced with reasonable accuracy from values of Ka,r that are reported in every angiography system.  相似文献   

3.

Aim

To calibrate Ir-192 high dose rate (HDR) brachytherapy source using different calibration methods and to determine the accuracy and suitability of each method for routine calibrations.

Background

The source calibration is an essential part of the quality assurance programme for dosimetry of brachytherapy sources. The clinical use of brachytherapy source requires an independent measurement of the air kerma strength according to the recommendations of medical physics societies.

Materials and methods

The Ir-192 HDR brachytherapy source from Gammamed plus machine (Varian Medical Systems, Palo Alto, CA) was calibrated using three different procedures, one using the well-type ionization chamber, second by the in-air calibration method and third using solid water phantoms. The reference air kerma rate (RAKR) of the source was determined using Deutsche Gesellschaft fur Medizinische Physik (DGMP) recommendations.

Results

The RAKR determined using different calibration methods are in good agreement with the manufacturer stated value. The mean percentage variations of 0.21, −0.94, −0.62 and 0.58 in RAKR values with respect to the manufacturer quoted values were observed with the well-type chamber, in-air calibration, cylindrical phantom and slab phantom measurements, respectively.

Conclusion

Measurements with a well-type chamber are relatively simple to perform. For in-air measurements, the indigenously designed calibration jig provides an accurate positioning of the source and chamber with minimum scatter contribution. The slab phantom system has an advantage that no additional phantom and chamber are required other than those used for external beam therapy dosimetry. All the methods of calibration discussed in this study are effective to be used for routine calibration purposes.  相似文献   

4.
5.
    
The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice.The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided.If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required.  相似文献   

6.
PurposeA new quality-control-based (QC-based) method is introduced to obtain correction factors to be applied to displayed patient dose indices (CTDIVol and DLP) on CT scanner consoles to verify improvement of dose surveys for diagnostic reference levels (DRLs) determination.MethodAn available data-base of QC documents and reports of 57 CT scanners in Tehran, Iran was used to estimate CTDIVol, DLP and relevant correction factors for three CT examination types including head, chest and abdomen/pelvis. The correction factor is the ratio of QC-based estimated dose to displayed dose. A dose survey was performed by applying on-site “data collection method” and correction factors obtained in order to select CT scanners in three modes for determination of CT DRLs by inclusion of: (a) all CT scanners before displayed dose indices were corrected (57), (b) only CT scanners calibrated by QC experts (41) and (c) all CT scanners after displayed dose indices were corrected (57).ResultsFor the 41 CT scanners, correction factors of three examination types obtained in this study are within the acceptance tolerance of IAEA HHS-19. The correction factors range from 0.45 to 1.7 (average of 3 examinations) which is due to the change in the calibrated value of CTDIVol over extended time. The DRL differences in three modes are within ±1.0% for CTDIVol and ±12.4% for DLP.ConclusionsThe “QC-based correction method” applied to mode (c) has improved the DRLs obtained by other two modes. This method is a strong alternative to “direct dose measurement” with simplicity and cost effectiveness.  相似文献   

7.
    
PurposeThe feasibility of setting-up generic, hospital-independent dose alert levels to initiate vigilance on possible skin injuries in interventional procedures was studied for three high-dose procedures (chemoembolization (TACE) of the liver, neuro-embolization (NE) and percutaneous coronary intervention (PCI)) in 9 European countries.MethodsGafchromic® films and thermoluminescent dosimeters (TLD) were used to determine the Maximum Skin Dose (MSD). Correlation of the online dose indicators (fluoroscopy time, kerma- or dose-area product (KAP or DAP) and cumulative air kerma at interventional reference point (Ka,r)) with MSD was evaluated and used to establish the alert levels corresponding to a MSD of 2 Gy and 5 Gy. The uncertainties of alert levels in terms of DAP and Ka,r, and uncertainty of MSD were calculated.ResultsAbout 20–30% of all MSD values exceeded 2 Gy while only 2–6% exceeded 5 Gy. The correlations suggest that both DAP and Ka,r can be used as a dose indicator for alert levels (Pearson correlation coefficient p mostly >0.8), while fluoroscopy time is not suitable (p mostly <0.6). Generic alert levels based on DAP (Gy cm2) were suggested for MSD of both 2 Gy and 5 Gy (for 5 Gy: TACE 750, PCI 250 and NE 400). The suggested levels are close to the lowest values published in several other studies. The uncertainty of the MSD was estimated to be around 10–15% and of hospital-specific skin dose alert levels about 20–30% (with coverage factor k = 1).ConclusionsThe generic alert levels are feasible for some cases but should be used with caution, only as the first approximation, while hospital-specific alert levels are preferred as the final approach.  相似文献   

8.
    
Conversion factors used to estimate effective (E) and organ doses (HT) from air Kerma area product (KAP) are required to estimate population doses in percutaneous transhepatic biliary drainage (PTBD) and trans arterial chemoembolization (TACE) interventional procedures.In this study, E and HT for ten critical organs/tissues, were derived in 64 PTBD and 48 TACE procedures and in 14,540 irradiation events from dosimetric, technical and geometrical information included in the radiation dose structured report using the PCXMC Monte Carlo model, and the ICRP 103 organ weighting factors. Conversion factors of: 0.13; 0.19; 0.26 and 0.32 mSv Gy−1 cm−2 were established for irradiation events characterized by a Cu filtration of 0.0; 0.1; 0.4 and 0.9 mm, respectively. While a single coefficient of conversion is not able to provide estimates of E with enough accuracy, a high agreement is obtained between E estimated through Monte Carlo methods and E estimated through E/KAP conversion factors accounting separately for the different modes of fluoroscopy and the fluorography component of the procedures.An algorithm for the estimation of effective and organ doses from KAP has been established in biliary procedures which considers the Cu filtration in the X-ray irradiation events. A similar algorithm could be easily extended to other interventional procedures and incorporated in radiation dose monitoring systems to provide dosimetric estimates automatically with enough accuracy to assess population doses.  相似文献   

9.
    
Medical physics has been an indispensable and strategic stakeholder in the delivery of radiological services to the healthcare system of Ghana. The practice has immensely supported radiation oncology and medical imaging facilities over the years, while the locally established training programme continues to produce human resource to feed these facilities. The training programme has grown to receive students from other African countries in addition to local students. Ghana has been recognised by the International Atomic Energy Agency as Regional Designated Centre for Academic Training of Medical Physicists in Africa. The Ghana Society for Medical Physics collaborates with the School of Nuclear and Allied Sciences of the University of Ghana to ensure that training offered to medical physicists meet international standards, making them clinically qualified. The Society has also worked together with other bodies for the passage of the Health Profession’s Regulatory Bodies Act, giving legal backing to the practice of medical physics and other allied health professions in Ghana. The country has participated in a number of International Atomic Energy Agency’s projects on medical physics and has benefited from its training courses, fellowships and workshops, as well as those of other agencies such as International Organization for Medical Physics. This has placed Ghana’s medical physicists in good position to practice competently and improve healthcare.  相似文献   

10.
    
PurposeTo compare the organ-dose and effective-dose (E) delivered to the patient during percutaneous vertebroplasty (PVP) of one thoracic or lumbar vertebra performed under CT guidance or using a fixed C-arm.MethodsConsecutive adult patients undergoing PVP of one vertebra under CT-guidance, with optimized protocol and training of physicians, or using a fixed C-arm were retrospectively included from January 2016 to June 2017. Organ-doses were computed on 16 organs using CT Expo 2.4 software for the CT procedures and PCXMC 2.0 for the fixed C-arm procedures. E was also computed with both software. Dosimetric values per anatomic locations for all procedures were compared using the paired Mann-Whitney-Wilcoxon test.ResultsIn total, 73 patients were analysed (27 men and 46 women, mean age 78 ± 10 years) among whom 35 (48%) underwent PVP under CT guidance and 38 (52%) PVP using a fixed C-arm. The median E was 11.31 [6.54; 15.82] mSv for all PVPs performed under CT guidance and 5.58 [3.33; 8.71] mSv for fixed C-arm and the differences was significant (p<0.001). For lumbar PVP, the organ doses of stomach, liver and colon were significantly higher with CT-scan than with the fixed C-arm: 97% (p=0.02); 21% (p=0.099) and 375% (p=0.002), respectively. For thoracic PVP, the lung organ dose was significantly higher with CT-scan than with the fixed C-arm (127%; p<0.001) and the oesophagus organ doses were not significantly different (p = 0.626).ConclusionThis study showed that the E and the organ dose on directly exposed organs were both higher for PVP performed under CT-guidance than with the fixed C-arm.  相似文献   

11.
    
PurposeThis study aims to investigate the relationship between backscatter factors and Al-half-value-layers (Al-HVL) by making the quality index (QI) a parameter for diagnostic kilovoltage x-ray beams.MethodsBackscatter factors, Bw, for x-ray fluence spectra were calculated from the weighted average of Bw for monoenergetic photons of between 8 and 140 keV with field sizes of 10 cm × 10 cm to 40 cm × 40 cm. The value of Bw for monoenergetic photons was calculated from the ratio of the water kerma at the surface of a water phantom and that at the same point free-in-air using the EGSnrc/cavity code. The weighted averaged backscatter factors were validated by comparing them with those of direct Monte Carlo calculations for the x-ray fluence spectra. The Bw for the x-ray fluence spectra were classified by a QI of 0.35, 0.4, 0.5, 0.6, and 0.7 specified by the ratio of the effective energy and maximum energy. The relationship between Bw and Al-HVL was evaluated for the given QI values. The x-ray fluence spectra were generated for tube voltages of 40–140 kVp with Al-HVLs of 0.5–13.2 mm using the SpekCalc program.ResultsThe weighted averaged backscatter factors for x-ray fluence spectra agreed within 0.7% with those of the direct Monte Carlo calculations. The backscatter factors were represented by the fitting curves of R2 > 0.99 with Al-HVL for the given QI values.ConclusionsIt is possible to obtain Bw more accurately by using QI specified by the measured Al-HVL.  相似文献   

12.
13.
    
PurposeThe aim of this study was to assess patient exposure data and operator dose in coronary interventional procedures, when considering patient body-mass index and procedure complexity.MethodsTotal air kerma area product (PKA), Air-Kerma (AK), Fluoroscopy time (FT), operator dose and patient body-mass index (BMI) from 97 patients’ procedures (62 coronary angiography (CA) and 35 Percutaneous Coronary Intervention (PCI) were collected for one year. For PCI procedures, also the complexity index-CI was collected. Continuous variables for each of the 2 groups procedures (CA and PCI) were compared as medians with interquartile range and using Mann-Whitney U test. Multiple group data were compared using Kruskal-Wallis test (significance: p < 0.05).ResultsMedian PKA was 63 and 125 Gy cm2 for CA and PCI respectively (p < 0.001); FT was 3 and 14 min, respectively (p < 0.001). PKA and FT significantly increased (p < 0.05) with BMI class for CA procedures. PKA and FT also increased in function of CI class for PCI, thought significantly only for FT (p < 0.001), possibly because of the low number of PCI procedures included; cine mode contributed most to PKA. Significant dose variability was observed among cardiologists for CA procedures (p < 0.001).ConclusionsDose references levels for PKA and FT in interventional cardiology should be defined - on a sufficient number of procedures- in function of CI and BMI classes. These could provide an additional tool for refining a facility’s quality assurance and optimization processes. Dose variability associated with cardiologists underlines the importance of continuous training.  相似文献   

14.
    
PurposeTo establish local diagnostic reference levels (DRLs) for non-cardiac interventional procedures in paediatrics.MethodsThe type of procedure, the patient’s weight and age and dose-related data from 279 interventions was recorded in a database completed by interventional radiologists, radiographers and technicians of the Medical Physics department. These procedures were classified into 14 categories and 6 weight ranges. Local DRLs were proposed for those ranges in which a sample of at least 15 patients could be gathered and were calculated as the third quartile (Q3) of the air kerma-area product (PKA) values. The Q3 of the fluoroscopy time (FT) and number of digital subtraction angiography (DSA) images were also obtained. Finally, the correlation between PKA and weight was analysed.ResultsLocal DRLs are proposed for three types of procedures: hepatic/biliary interventions (5–15 kg, 1304 cGy·cm2; 15–30 kg, 2121 cGy·cm2), sclerotherapy procedures (15–30 kg, 704 cGy·cm2; 30–50 kg, 4049 cGy·cm2; 50–80 kg, 3734 cGy·cm2) and central venous catheter (CVC) procedures (5–15 kg, 84 cGy·cm2). Hepatic/biliary interventions showed a moderate correlation (r = 0.61), while sclerotherapy procedures presented a poor correlation (r = 0.34) between PKA and weight, possibly due to the PKA dependence on the complexity level. Regarding CVC procedures, a clearly higher correlation was found when the fluoroscopy PKA value was normalised to the FT (r = 0.85 vs r = 0.35).ConclusionsThe results support the feasibility of establishing DRLs for the most common procedures (sclerotherapy, hepatic/biliary and CVC interventions) despite the small number of paediatric interventions.  相似文献   

15.
    
Benford's law is an empirical observation which predicts the expected frequency of digits in naturally occurring datasets spanning multiple orders of magnitude, with the law having been most successfully applied as an audit tool in accountancy. This study investigated the sensitivity of the technique in identifying system output changes using simulated changes in interventional radiology Dose-Area-Product (DAP) data, with any deviations from Benford's distribution identified using z-statistics.The radiation output for interventional radiology X-ray equipment is monitored annually during quality control testing; however, for a considerable portion of the year an increased output of the system, potentially caused by engineering adjustments or spontaneous system faults may go unnoticed, leading to a potential increase in the radiation dose to patients. In normal operation recorded examination radiation outputs vary over multiple orders of magnitude rendering the application of normal statistics ineffective for detecting systematic changes in the output. In this work, the annual DAP datasets complied with Benford's first order law for first, second and combinations of the first and second digits. Further, a continuous ‘rolling’ second order technique was devised for trending simulated changes over shorter timescales. This distribution analysis, the first employment of the method for radiation output trending, detected significant changes simulated on the original data, proving the technique useful in this case. The potential is demonstrated for implementation of this novel analysis for monitoring and identifying change in suitable datasets for the purpose of system process control.  相似文献   

16.
    
PurposeThe aim of the present study was to determine the efficiency of six methods for calculate the effective dose (E) that is received by health professionals during vascular interventional procedures.MethodsWe evaluated the efficiency of six methods that are currently used to estimate professionals’ E, based on national and international recommendations for interventional radiology. Equivalent doses on the head, neck, chest, abdomen, feet, and hands of seven professionals were monitored during 50 vascular interventional radiology procedures. Professionals’ E was calculated for each procedure according to six methods that are commonly employed internationally. To determine the best method, a more efficient E calculation method was used to determine the reference value (reference E) for comparison.ResultsThe highest equivalent dose were found for the hands (0.34 ± 0.93 mSv). The two methods that are described by Brazilian regulations overestimated E by approximately 100% and 200%. The more efficient method was the one that is recommended by the United States National Council on Radiological Protection and Measurements (NCRP). The mean and median differences of this method relative to reference E were close to 0%, and its standard deviation was the lowest among the six methods.ConclusionsThe present study showed that the most precise method was the one that is recommended by the NCRP, which uses two dosimeters (one over and one under protective aprons). The use of methods that employ at least two dosimeters are more efficient and provide better information regarding estimates of E and doses for shielded and unshielded regions.  相似文献   

17.
PurposeTo derive Regional Diagnostic Reference Levels (RDRL) for paediatric conventional and CT examinations using weight-based DRL curves and compare the outcome with DRL derived using the weight groups.MethodsData from 1722 examinations performed at 29 hospitals in four countries were included. DRL was derived for four conventional x-ray (chest, abdomen, pelvis, hips/joints) and two types of CT examinations (thorax, abdomen). DRL curves were derived using an exponential fit to the data using weight as an independent variable and the respective radiation dose indices (PKA, CTDIvol, DLP) as dependent variables. DRL was also derived for weight groups for comparison. The result was compared with national diagnostic reference level (NDRL) curves.ResultsThe derived curves show similarities with the NDRL curves available and corresponded sufficiently well with DRL for weight groups using the same data set, if sufficient number of data was available.ConclusionsWe conclude that weight-based DRL curves are a feasible approach and could be used together with DRL for weight groups. The main advantage of DRL curves is its application in the clinic. When the examination frequency is low, time to collect enough data to establish typical values for one or several weight groups may be unreasonably long. The curve provides the means to compare dose level faster and with fewer data points.  相似文献   

18.
    
ObjectiveThis paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used.MethodsMonte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature.ResultsSimulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°–60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data.ConclusionsSimple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation.  相似文献   

19.
目的:探讨16层螺旋CT不同剂量扫描对肺结节诊断价值及辐射度的影响。方法:选取2017年9月至2018年10月期间在青岛市中心医院就诊的肺结节患者200例,所有患者均接受16层螺旋CT常规剂量扫描和低剂量扫描。比较常规剂量扫描和低剂量扫描的图像质量、CT征象检出情况(分叶征、毛刺征、胸膜凹陷征、血管集束征、支气管征)、肺结节定性诊断结果(肺癌、肺转移瘤、炎性结节、定性困难)、肺结节大小分布(≤5 mm、6-10 mm、10 mm)、辐射度。结果:常规剂量和低剂量的扫描图像质量整体比较差异无统计学意义(P0.05),常规剂量和低剂量的CT征象检出情况(分叶征、毛刺征、胸膜凹陷征、血管集束征、支气管征)比较差异无统计学意义(P0.05),常规剂量和低剂量的肺结节定性诊断结果(肺癌、肺转移瘤、炎性结节、定性困难)比较差异无统计学意义(P0.05),常规剂量和低剂量的肺结节大小分布(≤5 mm、6-10 mm、10 mm)比较差异无统计学意义(P0.05),低剂量的总管球剂量、有效管球剂量、CT容积剂量指数及剂量长度乘积均明显低于常规剂量,差异有统计学意义(P0.05)。结论:16层螺旋CT低剂量扫描对肺结节的诊断价值与常规剂量扫描相当,并可有效减少辐射度,值得临床推广应用。  相似文献   

20.
    
PurposeThis study aimed to investigate the energy response of a radiophotoluminescent glass dosimeter (RGD) for diagnostic kilovoltage x-ray beams by Monte Carlo (MC) calculations and measurements.MethodsThe uniformity and reproducibility of GD-352M (with Sn filter) and GD-302M (no filter) were tested with 45 RGDs in free air. Subsequently, the RGD response was obtained as a function of an Al-HVL using the parameter, quality index (QI), which is defined as the ratio of the effective energy (keV) to the maximum energy (keV) of the photons. The x-ray fluence spectra with QI of 0.4, 0.5, and 0.6 were set for tube voltages of 50 ~ 137.6 kVp. The RGD response was calculated in free air using the MC method and verified by the air kerma, Kair, measured using an ionization chamber.ResultsThe uniformity and reproducibility of the 45 RGDs were ± 2.3% and ± 2.7% for GD-352M and ± 0.7% and ± 1.6% for GD-302M at the one standard deviation level, respectively. The calculated RGD response was 0.965 to 1.062 at Al-HVL 2.73 mm or more for GD-352M and varied from 3.9 to 2.8 for GD-302M. Both RGD responses exhibited a good correlation with the Al-HVL for the given QI. Kair measured by RGDs for each beam quality with a QI of 0.5 was in the range of −5%~0.8% for GD-352M and −1.8%~3% for GD-302M, relative to the chamber measurements.ConclusionsThe RGD response was indicated as a function of the Al-HVL for the given QI, and it presented a good correlation with the Al-HVL.  相似文献   